• Title/Summary/Keyword: 자성핀

Search Result 11, Processing Time 0.028 seconds

The Internal Finishing Characteristics of Non-ferromagnetic Pipe Polished by Magnetic Abrasive Machining(III) (자기연마법에 의한 비자성 파이브 내면의 연마특성(III))

  • Park, W. K.;Rho, T. W.;Seo, Y. I.;Choi, H.;lee, J. C.;Cheong, S. H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.915-918
    • /
    • 1997
  • An internal finishing process by the application of magnetic abrasive machining has been developed as a new technology to obtain a fine inner surface of pipe. In this paper, an abrasive circulation system was designed and manufactured. As a result, it was found that a fine inner surface abrasive of pipe was available by the use of this machining methods. The basic machining characteristics of pin-type magnetic tools were analyzed experimentally. In addition, the experimental results show that we can realize that pin-type magnetic tools have more machining efficiency than iron particles as magnetic tools.

  • PDF

Dispersion Characteristics of Magnetic Particle/Graphene Hybrid Based on Dispersant and Electromagnetic Interference Shielding Characteristics of Composites (분산제에 따른 자성금속 무전해도금 기반 그래핀 분산 특성 및 복합재의 전자파 차폐 특성 연구)

  • Lee, Kyunbae;Lee, Junsik;Jung, Byung Mun;Lee, Sang Bok;Kim, Taehoon
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.111-116
    • /
    • 2018
  • In this paper, magnetic FeCoNi particles have been grown through electroless plating on the surface of graphene, and then this hybrid material has been dispersed by various surfactants to prepare films. The pyridine surfactant shows the highest dispersability and low surface resistance value (351 Ohm/sq) and the electromagnetic shielding ability at the frequency of 10 GHz. Specially, the evaporation of the pyridine during the drying process could be able to form the internal conductive network and high dispersion of FeCoNi on the surface of graphene.

Magnetism and Electronic Structure of Tc Half-monolayer on Pd(oo1) Surface (Pd(001) 위에 올려진 Tc 0.5 웃층의 자성과 전자구조)

  • 김동철;이재일
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.5
    • /
    • pp.223-226
    • /
    • 1999
  • We have investigated the magnetic properties and the electronic structures of Tc half-monolayer (0.5-ML) on Pd(001) using the full-potential linearized augmented plane wave(FLAPW) energy band method. We calculated the total energies for ferromagnetic and paramagnetic states to determine the stable magnetic state. The calculated results show that the total energy of the ferromagnetic state is lower than that of the paramagnetic one. The overlayer Tc 0.5-ML has considerably large magnetic moment $(2.09\;{\mu}_B)$, while the substrate Pd layers have been negatively polarized. The calculated density of states and total electrons inside the muffin-tin (MT) sphere are presented and discussed in relation with the magnetic properties.

  • PDF

Preparation of PVA/Graphene Oxide/Fe3O4 Magnetic Microgels as an Effective Adsorbent for Dye Removal (폴리바이닐알코올/그래핀 옥사이드/산화철 자성 마이크로겔을 이용한 염료 제거)

  • Go, Seongmoon;Kim, Keunseong;Wi, Eunsol;Park, Rae-Su;Jung, Hong-Ryun;Yun, Changhun;Chang, Mincheol
    • Composites Research
    • /
    • v.35 no.2
    • /
    • pp.98-105
    • /
    • 2022
  • In this study, polyvinyl alcohol (PVA)/graphene oxide (GO)/iron oxide (Fe3O4) magnetic microgels were prepared using a microfluidic approach and the dye adsorption capacity of the microgels was confirmed. The adsorption capacity (qe) of the gels was evaluated by varying the dye concentration, pH, and contact time with the microgels. The dyes used in this work were methylene blue (MB), crystal violet (CV), and malachite green (MG), and microgels showed the highest adsorption capacity (191.1 mg/g) in methylene blue. The microgels exhibited the highest adsorption capacity in the dye aqueous solution at pH 10 due to the presence of atomic nitrogen ions (N+) on the dye molecules. The adsorption isotherm studies revealed that the Langmuir isotherm is the best fit isotherm model for the dye adsorption on the microgels, indicative of monolayer adsorption. The kinetic analysis exhibited that the pseudo-second order model fits better than the pseudo-first order model, confirming that the adsorption process is chemisorption. In addition, the magnetic microgels showed good reusability and recovery efficiency. It was confirmed that the adsorption capacity of the gels maintains more than 70% of the initial capacity after 5 times of cycle experiments.

Nondestructive Examination of Ferromagnetic Tube Using Magnetic Saturation Eddy Current Technique (자기포화 와전류기법에 의한 자성 튜브 비파괴검사)

  • Lee, Hee-Jong;Cho, Chan-Hee;Song, Seok-Yoon;Jee, Dong-Hyun;Jung, Jee-Hong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.407-415
    • /
    • 2008
  • The tubes in heat exchanger are typically made from copper alloy, stainless steel, carbon steel, titanium alloy material. type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can typically be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs). LP feedwater heaters generally utilize thin wall type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the OD(outside diameter) surface of type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

Smart Decontamination Device for Small-size Radioactive Scrap Metal Waste : Using Abrasion pin in Rotating Magnetic Field and Ultrasonic Wave Cleaner (소형 금속방사성폐기물 제염장치 개발 : 자기장 연삭핀과 초음파 세정기의 응용)

  • Hong, Yong-Ho;Park, Su-Ri;Han, Sang-Wook;Kim, Byung-Jick
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.12 no.1
    • /
    • pp.79-88
    • /
    • 2014
  • We have developed a smart decontamination device for small-size radioactive scrap metal (SSRSM) necessarily generated from nuclear facilities. This is a multi-modal device such as rotation of magnetic field focusing on the region containing the abrasion pins placed around target and ultrasonic cleaner. Additionally, in order to increase the decontamination efficiency we have modified some configuration of the device so that it could work on them evenly and totally. With the Optimal operating for operation of the new device, we tried to decontaminate some various metal selected as a sample during 15 minutes sequentially using each method, magnetic and ultrasonic device. As a result, the range of decontamination factor has been highly increased to 18~56. After decontamination, all samples were found its activity less than background level.

Comparative Photoluminescence Study of Single-Layer MoS2 Annealed in Hydrogen and Vacuum

  • Ryu, Ye-Jin;Park, Min-Gyu;Ryu, Sun-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.195.1-195.1
    • /
    • 2014
  • 최근 반자성 물질인 $MoS_2$를 수소 기체 속에서 열처리하게 되면 약한 강자성이 유발된다는 연구가 보고되었다. 본 연구에서는 강자성 발현을 수반하는 물리적 및 화학적 변화를 이해하기 위해서 단일층 $MoS_2$에 대한 라만분광 및 광발광 연구를 수행하였다. 기계적 박리법을 이용하여 $MoS_2$ 결정으로부터 단일층 및 이중층 $MoS_2$를 분리하여 $SiO_2/Si$ 기판에 전사한 후, $200^{\circ}C{\sim}500^{\circ}C$ 영역의 특정 온도에서 1시간 동안 열처리하였다. 배경 기체가 열처리 도중 $MoS_2$에 미치는 영향을 이해하기 위하여 수소 속 반응을 진공 상태와 비교하였다. 라만 스펙트럼에서는 큰 변화가 없었으나, 광발광의 세기는 수소 속 반응 후에 감소하고 진공 속 반응 후에는 증가하는 대조적인 결과를 보였다. AFM 측정으로부터는 열처리 후에 $MoS_2$ 표면에 뚜렷한 변화가 일어나지 않는다는 사실을 확인하였다. 본 발표에서는 수소와 진공 조건에서 관찰된 상이한 광발광 특성과 그래핀/$SiO_2/Si$에서 관찰된 p-형 도핑과의 상관관계를 설명하고자 한다.

  • PDF