• Title/Summary/Keyword: 자동화 기술

Search Result 2,997, Processing Time 0.029 seconds

Evaluation of Coated Tube CA19-9 IRMA kit (Coated tube를 사용한 CA19-9 측정용 IRMA 시약의 평가)

  • Lee, Hyun-Ju;Jang, Hyun-Young;Shin, Sun-Young;Kim, Hee-Sun;Kim, Tae-Hoon;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.208-211
    • /
    • 2010
  • Purpose: $TFB^{(R)}$ CA19-9 IRMA kit uses beads coated with CA19-9 antibody. However, this mathod can not use automated equipment, and requires a long time test. Recently, CA19-9 IRMA kit developed by $TFB^{(R)}$ is coated with CA19-9 antibody to the polystyrene test tube and reaction at room temperature, and also reduced test time. This study evaluated the performance of a newly developed $TFB^{(R)}$ CA19-9 IRMA kit. Materials and Methods: This study were measured by using 56 patients sample of Boramae Medical Center and Seoul National University Hospital. We evaluated intra-and inter-assay precision, recovery rate, linearity, sensitivity and high dose hook effect of coated tube CA19-9 IRMA kit developed by $TFB^{(R)}$. The values of CA19-9 measured by $TFB^{(R)}$ bead kit were compared with those measured by $TFB^{(R)}$ coated tube kit. Results: ntra-assay coefficients of variation on three different levels were 4.1%, 4.0% and 4.2%. Inter-assay coefficients of variation were 7.6%, 4.3% and 7.8%. Recovery tests on all three different levels showed within $100{\pm}10%$. Linearity was good and sensitivity was 0.3 U/mL. High dose hook effect is not observed. There was strong correlation between bead kit and coated tube kit by $TFB^{(R)}$ CA19-9 IRMA kit. (y=0.9185x-0.953, $R^2$=0.9779) Conclusion: Coated tube CA19-9 IRMA kit developed by $TFB^{(R)}$ showed satisfactory precision, recovery rate, linearity, sensitivity and high dose hook effect.

  • PDF

The Correlation Analysis of Stress/Rest Ejection Fraction of $^{201}Tl$ Gated Myocardial Perfusion SPECT ($^{201}Tl$ 게이트 심근관류 스펙트에서의 휴식기와 부하기 좌심실 구혈률 상관관계 분석)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Shim, Dong-Oh
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.3-9
    • /
    • 2009
  • Purpose: It is well-known that stress-induced stunning and reversible perfusion defect have impact on ejection fraction (EF) when performing myocardial perfusion SPECT. Due to these reasons, gated SPECT is recommended at stress and rest studies. And there was many experiments to analyze between Stress and Rest EF by using $^{99m}Tc$-MIBI. The aim of this study is to analyze between stress EF and rest EF at myocardial perfusion SPECT by using $^{201}Tl$ and define possible predictors of EF variability. Materials and Methods: From 2008 June to 2009 February, we analyzed 144 patients undergoing $^{201}Tl$ gated myocardial perfusion SPECT in ASAN medical center. To analyze the data, we use QGS (Quantitative gated SPECT) software, and derived End-systolic volume (ESV), End-diastolic volume (EDV), EF from the result. In this study, we comparatively analyzed stress/rest EF correlation based on stress/rest EF, EDV, ESV and reversibility of myocardial perfusion defect by using paired t-test, Bland-Altman analysis. Results: Mached pairs of stress EF and rest EF demonstrated excellent correlation (r=0.92) with no statistically significant difference (p=0.11). Bland-Altman analysis demonstrated a mean ${\Delta}EF$ was 0.52% (95% confidential interval[CI], -1.17~0.12%). No statistically significant difference between a mean ${\Delta}EF$ and hypothetic mean of 0 (${\Delta}EF$=0) (p=0.10). In the correlation of ${\Delta}EF$ according to stress/rest EDV and ESV, except rest ESV of <28mL (p<0.05), there was no statistically significant difference. In the correlation of ${\Delta}EF$ according to reversibility of perfusion defect, patients with reversible perfusion defect has statistically significant difference of ${\Delta}EF$ (p<0.05). ${\Delta}EF$ of stress/rest EF showed no statistically significant difference except 55% of rest EF (p<0.05). Conclusion: Like studies with $^{99m}Tc$-MIBI, there was generally no statistically significant difference between stress and rest EF in this study results. However a stress EF of <55%, a rest ESV of <28mL and patients with reversible perfusion defect showed statistically significant difference in ${\Delta}EF$. If performing $^{201}T$ myocardial perfusion SPECT to patients with abnormal cardiac function or reversible perfusion defect, consider this study results and apply it. We expect this study results could be useful predictors of ${\Delta}EF$ variability.

  • PDF

A Study on the Development of a Home Mess-Cleanup Robot Using an RFID Tag-Floor (RFID 환경을 이용한 홈 메스클린업 로봇 개발에 관한 연구)

  • Kim, Seung-Woo;Kim, Sang-Dae;Kim, Byung-Ho;Kim, Hong-Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.2
    • /
    • pp.508-516
    • /
    • 2010
  • An autonomous and automatic home mess-cleanup robot is newly developed in this paper. Thus far, vacuum-cleaners have lightened the burden of household chores but the operational labor that vacuum-cleaners entail has been very severe. Recently, a cleaning robot was commercialized to solve but it also was not successful because it still had the problem of mess-cleanup, which pertained to the clean-up of large trash and the arrangement of newspapers, clothes, etc. Hence, we develop a new home mess-cleanup robot (McBot) to completely overcome this problem. The robot needs the capability for agile navigation and a novel manipulation system for mess-cleanup. The autonomous navigational system has to be controlled for the full scanning of the living room and for the precise tracking of the desired path. It must be also be able to recognize the absolute position and orientation of itself and to distinguish the messed object that is to be cleaned up from obstacles that should merely be avoided. The manipulator, which is not needed in a vacuum-cleaning robot, has the functions of distinguishing the large trash that is to be cleaned from the messed objects that are to be arranged. It needs to use its discretion with regard to the form of the messed objects and to properly carry these objects to the destination. In particular, in this paper, we describe our approach for achieving accurate localization using RFID for home mess-cleanup robots. Finally, the effectiveness of the developed McBot is confirmed through live tests of the mess-cleanup task.

The Evaluation of Radioimmunoassay kits for Insulin (Insulin 측정용 방사면역측정법 시약의 평가)

  • Shin, Yong Hwan;Kim, Yun Hyun;Lee, Il Kyu;Kim, Ji Young;Seok, Jae Dong;Shin, Suk Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.149-155
    • /
    • 2012
  • Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic ${\beta}$ cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 ${\mu}IU/ml$ high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured, but Biosource and Immunotech kits were measured 47.4 ${\mu}IU/ml$, 72.3 ${\mu}IU/ml$, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

  • PDF

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Effect of Antibody Immobilization Method to Magnetic Micro Beads on its Immunobinding Characteristics (자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향)

  • Choi, Hyo Jin;Hwang, Sang Youn;Jang, Dae Ho;Cho, Hyung Min;Kang, Jung Hye;Seong, Gi Hun;Choo, Jae Bum;Lee, Eun Kyu
    • Korean Chemical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.65-72
    • /
    • 2006
  • Recent technical advances in the biorecognition engineering and the microparticle fabrication may enable us to develop the single step purification using magnetic particle, because of its simplicity, efficacy, ease of automation, and process economics. In this study, we used commercial magnetic particles from Seradyn, Inc. (Indianapolis, USA). It was ca. 2.8 micron in diameter, consisted of polystyrene core and magnetite coating, and its surface had carboxyl groups. The model, capture protein was IgG and anti-IgG was used as the ligand molecule. We studied the different surfaces ('nude', ester-activated, and anti-IgG coated) for their biorecognition of IgG. At a high pH condition, we could reduce non-specific binding. Also anti-IgG immobilized magnetic particle could capture IgG more selectively. We attempted 'oriented immobilization' of anti-IgG, in which the polysaccharides moiety near the C-terminus was selectively oxidized and linked to the hydrazine-coated MP, to improve the efficacy of biorecognitive binding. Using this method, the IgG capturing ability was improved by ca. 2 fold. From the binary mixture of the IgG-insulin, IgG could be more selectively captured. In summary, the oriented immobilization of oxidized anti-IgG proved to be as effective as the streptavidin-biotin system and yet simpler and cost-effective. This immobilization method can find its applications in protein biochips and biotargeting.

The Assessment of Ultrasensitive HBsAg kit's Sensitivity level and Performance in Detection of Mutant Forms (Ultra-sensitive HBsAg IRMA 키트의 민감도 및 변이형 검출능 평가)

  • Ha, Dong-Hyuk;Min, Kyung-Sun;Noh, Gyeong-Woon;Kim, Hyun-Ju
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.121-125
    • /
    • 2011
  • Purpose: The DNA-type virus HBV, discovered by D. Dane and others in 1976, is approximately 42nm big and known as the main cause of liver-related diseases around the world. HBsAg has 4 kinds of subtypes including adw, adr, ayw and ayr and besides common antigen factor a, there are d, y, r, w. From the methods of serologically testing HBV, IRMA, EIA and CLIa were developed for testing HBsAg and are being used in examining the surface antigen of HBV. In this study, among the methods for testing HBV, the recently developed RIAKEY Ultrasensitive HBsAg IRMA kit's sensitivity level and performance in detection of mutant forms were measured and compared with CLIA. Materials and methods: Two certified reference materials, which are WHO 1st International Standard 1985(80/549) and WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA), were used in the examination and the sensitivity level was measured by diluting these materials from 0.08 IU/ml to 0.005 IU/ml. The materials for examining the detection of mutant forms included 9 kinds of subtype 'ad' and one kind of subtype 'ay' purchased from DSI company. Also, with the use of positive and negative samples, they was compared with CLIA. Result: Ultrasensitive HBsAg kit based on IRMA method showed the detection of up to 0.01 IU/ml not only for WHO 1st International Standard 1985(80/549) but also for WHO 2nd International Standard 2003(00/588. subtype adw2, genotypeA) and the sensitivity level was measured as 0.01 IU/ml by WHO standard. In testing the performance for detection of mutant forms, the 9 kinds of subtype 'ad' and one kind of subtype 'ay' mutant materials were detected, demonstrating the capacity of detecting various types of mutant forms. Conclusions: With the clinical importance of sensitivity level and performance in detection of mutant forms increasing in the field of HBsAg diagnosis, the examination of IRMA's effectiveness using RIA method in the aspects of the sensitivity level and performance in detection of mutant forms was carried out and its result is as follows. The sensitivity level was measured as 0.01 IU/ml by WHO standard and it was possible to measure various types of mutant forms with high sensitivity. Thus it is suggested that more speedy and accurate reports could be produced from a nuclear medicine laboratory for clinical practitioners requiring results of various situations.

  • PDF

Detection of rpoB Gene Mutation in Rifampin-Resistant M. Tuberculosis by Oligonucleotide Chip (Oligonucleotide chip을 이용한 Rifampin 내성 결핵균의 rpoB 유전자 돌연변이 검출)

  • Park, Soon-Kew;Lee, Min-Ki;Chung, Byung-Seon;Kim, Cheol-Min;Chang, Chul-Hun L.;Park, Hee-Kyung;Jang, Hyun-Jung;Park, Seung-Kyu;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.5
    • /
    • pp.546-557
    • /
    • 2000
  • Background : Oligonucleotide chip technology has proven to be a very useful tool in the rapid diagnosis of infectious disease. Rifampin resistance is considered as a useful marker of multidrug-resistance in tuberculosis. Mutations in the rpoB gene coding $\beta$ subunit of RNA polymerase represent the main mechanism of rifampin resistance. The purpose of this study was to develop a diagnosis kit using oligonucleotide chip for the rapid and accurate detection of rifampin-resistance in Mycobacterium tuberculosis. Method : The sequence specific probes for mutations in the rpoB gene were designed and spotted onto the glass slide, oligonucleotide chip. 38 clinical isolates of Mycobacterium were tested. A part of rpoB was amplified, labelled, and hybridized on the oligonucleotide chip with probes. Results were analyzed with a laser scanner. Direct sequencing was done to verify the results. Result : The low-density oligonucleotide chip design어 to determine the specific mutations in the rpoB gene of M. tuberculosis accurately detected rifampin resistance associated with mutations in 28 clinical isolates. Mutations at codons 531, 526, and 513 were confirmed by direct sequencing analysis. Conclusion : Mutant detection using oligonucleotide chip technology is a reliable and useful diagnostic tool for the detection of multidrug-resistance in M. tuberculosis.

  • PDF

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF

Channel Innovation through Online Transaction processing System in Floral Wholesale Distribution: FLOMARKET Case (화훼도매 온라인 거래처리 시스템을 통한 유통경로 개선방안 연구: (주)플로마켓 사례)

  • Lee, Seungchang;Ahn, Sunghyuck
    • Journal of Distribution Science
    • /
    • v.8 no.1
    • /
    • pp.21-33
    • /
    • 2010
  • The ICT(information & communication technology) led to a dramatic change of floral distribution service, a phase of competition between wholesales and retail stores, and distribution channels in floral industry. It was expected that a role of the intermediaries in this industry would have reduced due to the improvement of transaction process by ICT. However, the ICT made to overcome a regional limit of the floral retail distribution service leading to an increase in sales and enlargement of the stores. And even it made possible to bring out another type of intermediaries such as private associations. This case study focuses on what kinds of efforts the floral wholesale distributors have made to enable a distribution process more smoothly between the wholesale distributors and retail stores through the information system, and what the failure factors in adopting the information system have been. This paper is also to examine how the wholesale distributors have changed themselves to gain dominant positions in distribution channels. As a result of the study, it was found that the intermediaries mostly failed in successfully achieving the distribution channel innovation through the information system because of several main reasons. FLOMARKET Inc. tried to innovate a distribution channel to obtain high quality goods through consolidating a wholesale distribution market in that segregated both floral joint market from free markets. after implementing the information system with consideration of the failure factors, FLOMARKET Inc. was able to minimize goods in stock and make a major purchase of various goods. In addition, it made a possible pre-ordering process and an exact calculation of purchasing goods so they could provide their products with market price in real time, which helped for the company to gain credits from their customers. Also, FLOMARKET Inc. established the information system which well suited to its business stage in order to deal with a rapidly changing distribution environment. It's so obvious that the transaction processing system of FLOMARKET Inc. definitely helped to share information among traders more seamlessly and smoothly in realtime, standardize goods, and make a transaction process clearer. Besides, the transaction information helped the wholesale distributors and retail stores to make more strategic decisions in their business because through the system they enabled to gather the marketing intelligence information more easily and convenient. If we understand that the floral distribution market is characterized by the low IT- based industry, it's worth to examine a case study proving that the information system actually increases the productivity of the transaction process in the floral industry.

  • PDF