• Title/Summary/Keyword: 자동차 터널

Search Result 61, Processing Time 0.03 seconds

Recommendations of Safety Design in Road Tunnels - Based on up-to dated experiences - (도로터널의 방재설계 -사례중심으로-)

  • Park, Jung-Joo
    • Tunnel and Underground Space
    • /
    • v.17 no.5
    • /
    • pp.337-349
    • /
    • 2007
  • Yearly, it seems the fact that the numbers of tunnels with wide sections are on the rise as the length of tunnel and number of lanes continues increasing. According to these trends, well-schemed plans of design, construction and management related with tunnel safety has become to be crucial. It is a high possibility to be observed by the fact that the direct effects of casualties and property damages are caused by the situations of car collisions, bump to solid structures by careless driving and the outbreak on vehicles by mechanical fault. Therefore, in order to prevent these types of accidents, we would make issues md adopt appropriate mechanical and management plans of emergency exits and disaster prevention equipments inside of tunnel, based on up-to dated experiences and study of foreign cases, to structural design technology. The objectives of this study are to recognize related actual problems and suggest improvement plans.

Early Detective Warning System of Fire in the Tunnel Road (도로터널 내 차량사고 화재조기감지 예고 시스템)

  • Yoon, Sungwook;Kim, Hyenki
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2012.05a
    • /
    • pp.291-292
    • /
    • 2012
  • 본 연구는 여러 가지 센서를 이용하여 자동차 전용 도로터널의 차량 사고시의 음향을 인식하여 사고인식률을 높이는 화재 예고 시스템에 관한 연구이다. 현행의 CCTV나 자동화재탐재설비에서 감지하는 열센서나 영상전송자료를 파악하기에 앞서, 이차적 재해 가능성을 유의미한 수준에서 미리 예고하고 대응할 수 있는 사전예고시스템을 구성하였다. 유선설치기반의 센서로 대부분 구성된 도로터널 내에서 비교적 설비가 저렴한 무선센서를 사용함으로서 기존 터널에서의 적용성을 증대시켰다.

  • PDF

Development of the mobile measuring system for tunnel lighting luminance and illuminance (차량을 이용한 터널조도 및 휘도 측정시스템 개발)

  • Kim, Dong-Jo;Jo, Duk-Soo;Jeong, Yeon-Seong;Suk, Dae-Il;Jung, Seung-Kyun;Lee, Chang-Mo;Nam, Dong-Hun;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.51-55
    • /
    • 2005
  • 터널은 밝기가 급변하는 장소로서 자동차 운전자가 터널 진입 시 도로의 상황이나 교통상황을 정확히 파악하여 안전하고 불안감 없이 도로를 통행 할 수 있게 하여야 한다. 터널내의 충분한 노면휘도 유지를 위하여 터널내부의 조도를 정기적으로 측정하여야 하는데 기존의 수동식 측정법으로는 신속하고 신뢰적인 조도측정에 한계가 있다. 따라서 본 논문에서는 차량을 이용한 터널조도 및 휘도 측정시스템 개발과 함께 운용타당성에 대한 결과를 외국 사례와 함께 터널 실험을 통하여 결론을 도출하였다.

  • PDF

Analysis of the measured illuminance and luminance values from tunnel lighting mobile measuring system (차량 계측 시스템을 이용한 터널의 조도 및 휘도 실측값 분석)

  • Kim, Dong-Jo;Nam, Dong-Hoon;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.195-199
    • /
    • 2005
  • 우리나라는 국토의 65% 이상이 산악지대로서 일반도로, 고속도로, 산업도로에서 터널이 차지하는 비중이 점차 증대되어지고 있다. 터널은 밝기가 급변하는 장소로서 자동차 운전자가 터널 진입 시 도로의 상황이나 교통상황을 정확히 파악하여 안전하고 불안감 없이 도로를 통행 할 수 있게 하여야 한다. 터널내의 충분한 노면휘도 유지를 위하여 터널내부의 조도를 정기적으로 측정하여야 하는데 기존의 수동식 측정법으로는 신속하고 신뢰적인 조도측정에 한계가 있다. 따라서 본 논문에서는 차량을 이용한 측정시스템을 이용하여 터널조도 및 휘도를 측정하고 그 실측값을 분석하였다.

  • PDF

A study on the effects of exhaust emission standards on the required ventilation rate in vehicle tunnels (차량 배출가스 규제기준이 소요환기량에 미치는 연구)

  • Kim, Hyo-Gyu;Ryu, Ji-Oh;Song, Seog-Hun;Jung, Chang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.409-420
    • /
    • 2017
  • The amount of ventilation required in making the tunnel ventilation plan is an important factor for determining the capacity of the ventilation system. The amount of pollutant emission for each type of vehicle (basic emission amount for the design of ventilation volume) for estimating the required ventilation amount is based on the 'Standard for Allowing the Emission for the car manufacturing', proposed by Ministry of Environment. However, in 2013, the Ministry of Environment announced the 'Regulations on the calculation method of total emissions from vehicles' as a regulation for calculating the pollutants emitted from vehicles. In this regulation, there are the 'Emission factors for each type of vehicle'. Therefore, it is necessary to review the application of the Regulation to the estimation of the required ventilation volume for the road tunnel. In this study, the influence of the strengthened emission regulation in 2015 caused by the case of manipulation of emission volume for the diesel vehicle on the calculation of the required ventilation volume in the road tunnel has been checked. In addition, in this study, the required ventilation volume calculated according to the Standard for Allowing the Emission for the car manufacturing revised by Ministry of Environment and "Emission factors for each type of vehicle" and that calculated according to the EURO emission standard were compared for analysis. This study has implications that it provides the basic design data for calculating the reasonable ventilation capacity of the ventilation system based on the ground for calculating the required ventilation volume.

The Real Scale Fire Test in Tunnel for Fire Detector Performance Evaluation (터널에서의 화재 감지기 성능 평가를 위한 실물화재실험)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.96-101
    • /
    • 2010
  • 본 연구에서는 터널 내부에서의 화재 사고 시 화재를 자동으로 조기 발견 경보하여 화재 초기에 대응력을 확보시킬 수 있게 하는 화재 감지기의 성능 평가를 위해 터널 내부에서의 실물 화재 실험을 실시하였다. 실물화재실험은 일반적으로 도로 터널에 적용 중인 공기관식, 반도체식 감지기를 대상으로 "도로터널 방재시설 설치지침(2004, 건설교통부)"의 터널 내부의 화재 감지기 성능 실험 기준에 따라 메탄올을 이용한 풀버너와 소형 승용차를 이용하였다. 실험결과 메탄을 풀화재(단면적 $4m^2$)의 경우 약 36초 안에 모두 화재를 감지하였으며, 실물자동차화재실험의 경우는 1분 이내에 모두 화재를 감지하는 결과를 나타내었다.

  • PDF

The Risk Assessment of Tunnel Fire Through Real Scale Fire Test (실물터널 화재실험을 통한 터널화재 위험도 평가)

  • 최준석;최병일;김명배;한용식;장용재;이유환;황낙순;김필영
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2002
  • The real scale tunnel fire tests are carried out for the first time in domestic range to assess the extent of risk in the tunnel fire. The tunnel dimension is 465 m in length, 9.2 m in width and 6.5 m in height. Gasoline pools with 0.25 MW∼2.5 MW size and a 1500CC passenger car are used as fire sources. Six jet fans are used to change the flow velocity inside the tunnel. Temperatures at total 86 points in the tunnel are measured to find the temperature distribution and smoke behavior in the real tunnel fire. In the experiment, it is examined that the important parameters to assess the extent of risk in tunnel fire such as back layering of smoke front, descending of smoke layer and the fire size of a real passenger car.

Experimental Study on the Effect of the Area Ratio between Shaft and Tunnel and Heat Release Rate on the Plug-holing Phenomena in Shallow Underground Tunnels (저심도 도로터널에서 터널과 수직환기구의 단면적 비와 열방출률이 Plug-holing 현상에 미치는 영향에 관한 실험연구)

  • Hong, Kibea;Na, Junyoung;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.619-625
    • /
    • 2019
  • It is difficult to design because of the plug-holing phenomenon in which the amount of smoke discharged from the vertical vent is smaller than the designed amount of smoke. In this study, the effect of cross-sectional area ratio of tunnel and natural ventilation and heat release rate of fire source on plug-holing phenomenon occurring in natural ventilation system was experimentally analyzed. In the experiment model reduced to 1/20 size, the aspect ratio of the tunnel and the vertical vent was fixed, and the influence on the plug-holing phenomenon was confirmed by varying the sectional area ratio of the tunnel and the vertical vent. Experimental results show that the plug-holing phenomenon is caused by the comparison of the smoke boundary layer temperature with the temperature in the vertical vents, and the flow and temperature distribution characteristics under the vertical vents are changed as the cross-sectional area ratio of the tunnel and vertical vents increases. The plug-holing phenomenon is affected by the cross-sectional area ratio between the tunnel and the vertical ventilation. The greater the cross-sectional area ratio, the greater the probability of plug-holing.

Characteristics of Thermo-Fluid Flow in Dilution Chamber of Micro-Dilution Tunnel for Diesel Particulate Measurement (디젤매연측정용 마이크로 희석터널의 희석챔버에서의 열유동 특성)

  • 김태권;김성훈;임문혁
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.6
    • /
    • pp.90-99
    • /
    • 2002
  • The main purpose of this study lies on the development of micro dilution tunnel based on the Sierra Dilution chamber model. As a primary examination, characteristics of flow and temperature distributions during the steady dilution process in dilution chamber are observed with numerical analysis. The penetration of dilution air through porous tube as well as wall temperature and temperature gradient inside porous tube are examined. The thermophoretic velocity in terms of temperature behavior inside porous tube are defined and examined. Based on the ratio of penetration and thermophoretic velocities, all part of porous tube are shown to be safe from the particulate depositions. However, The inlet portion of porous tube in addition to the portion of impinging of dilution air are marginally safe from the particulate depositions. Generally the safer design against particulate deposition is required in provision f3r steady dilution process and for transient process as well.