• Title/Summary/Keyword: 자기 플럭스

Search Result 52, Processing Time 0.033 seconds

A study and experiment on the stabilization characteristic and the stiffness in Active Magnetic Bearing (자기베어링시스템 강성의 실험적 고찰을 통한 안정화 특성에 관한 연구)

  • 강성구;강종규;홍준희
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.388-392
    • /
    • 2004
  • Due to the lack of stiffness and difficulties of control, it is hard to achieve well balanced magnetic levitation. In this paper, we analysis the current and position stiffness change according to bias current through experiment. Then, compensation equations were presented. After obtaining PD gain for each bias current and PD gain region through levitation experiment, we consider the characteristics.

  • PDF

Geomagnetic Disturbances by Steel Skeletons (철골에 의한 지자기 교란)

  • 송승한;이문호;배성호;신현진
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.1
    • /
    • pp.32-37
    • /
    • 2001
  • Effects of steel-skeletons on the geomagnetic distribution in building have been studied through the simulation and measurement of geomagnetic distribution at floor surface. Geomagnetic distribution was simulated by the finite element method, and the vertical component Z of geomagnetic field on the floor surface was measured with the fluxgate-type magnetometer. Horizontal steel-skeletons have a little effect on the Z distribution, but vertical skeletons disturb severely the Z distribution and result in the localized geomagnetic disturbance. This disturbance becomes weakened by the bypassing soft-magnetic plate and/or floor.

  • PDF

Development of KAMG engineering model in KPLO mission

  • Jin, Ho;Kim, Khan-Hyuk;Son, Derac;Lee, Seongwhan
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.48.4-48.4
    • /
    • 2018
  • 대한민국 달탐사 시험용 궤도선은 2020년 말에 발사를 예정으로 위성개발이 진행되고 있다. KPLO(Korea Pathfinder Lunar Orbiter) 라고 명명된 달 궤도선에는 6개의 탑재체가 있으며, 경희대학교 우주탐사학과에서는 달 주위 공간 및 달 표면의 이상 자기장 영역을 관측하는 탑재체 (KMAG: Kplo MAGnetometer)를 개발하고 있다. 자기장센서는 3축 플럭스게이트 센서를 사용하며 약 0.2nT 이하의 분해능을 가지고 있다. 측정주기는 10Hz이며 총 무게는 3.5kg 이다. 1.2m 길이의 붐(Boom) 구조물 내부에 3개의 자기장 센서들을 설치하였으며 가능한 위성체로부터 거리를 두고 자기장을 측정하는 구조로 구성하였다. 시험모델 개발을 완료하고, 개발된 탑제체의 환경시험결과와 성능시험결과 요구조건에 부합되는 결과를 얻었다. KAMG는 국내최초의 심우주 탐사용 자기장 측정기로서 향 후, 행성 및 소행성 탐사 등에 활용하기 위한 기반 기술로 활용할 수 있을 것으로 기대한다.

  • PDF

Plasma Sources for Production of High Flux Particle Beams in Hyperthermal Energy Range (하이퍼써멀 에너지 영역에서 높은 플럭스 입자빔 생성을 위한 플라즈마 발생원)

  • Yoo, S.J.;Kim, S.B.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.186-196
    • /
    • 2009
  • Since it is difficult to extract a high flux ion beam directly at an energy of hyperthermal range ($1{\sim}100\;eV$), especially, lower than 50 eV, the ions should be neutralized into neutral particles and extracted as a neutral beam. A plasma source required to generate and efficiently transport high flux hyperthermal neutral beams should be easily scaled up and produce a high ion density (${\ge}10^{11}\;cm^{-3}$) even at a low working pressure (${\le}$ 0.3 mTorr). It is suggested that the required plasma source can be realized by Electron Cyclotron Resonance (ECR) plasmas with diverse magnetic field configurations of permanent magnets such as a planar ECR plasma source with magnetron field configuration and cylindrical one with axial magnetic fields produced by permanent magnet arrays around chamber wall. In both case of the ECR sources, the electron confinement is based on the simple mirror field structure and efficiently enhanced by electron drifts for producing the high density plasma even at the low pressure.

A Micro Fluxgate Magnetic Sensor with Closed Magnetic Path (폐자로를 형성한 마이크로 플럭스게이트 자기 센서)

  • 최원열;황준식;강명삼;최상언
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.3
    • /
    • pp.19-23
    • /
    • 2002
  • This paper presents a micro fluxgate magnetic sensor in printed circuit board (PCB). In order to observe the effect of the closed magnetic path, the magnetic cores of rectangular-ring and two bars were each fabricated. Each fluxgate sensor consists of five PCB stack layers including one layer magnetic core and four layers of excitation and pick-up coils. The center layer as a magnetic core is made of a Co-based amorphous magnetic ribbon with extremely high DC permeability of ~100,000. Four outer layers as an excitation and pick-up coils have a planar solenoid and are made of copper foil. In case of the fluxgate sensor having the rectangular-ring shaped core, excellent linear response over the range of -100 $\mu$T to + 100 $\mu$T is obtained with 540 V/Tsensitivity at excitation square wave of 3 $V_{p-p}$ and 360 KHz. The chip size of the fabricated sensing element is $7.3 \times 5.7\textrm{mm}^2$. The very low power consumption of ~8 mW was measured. This magnetic sensor is very useful for various applications such as: portable navigation systems, telematics, VR game and so on.n.

  • PDF

Simulation of time-domain bottom reverberation signal using energy-flux model (에너지 플럭스 모델을 활용한 해저 잔향음 신호 모의)

  • Jung, Young-Cheol;Lee, Keun-Hwa;Seong, Woojae;Kim, Seongil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.1
    • /
    • pp.96-105
    • /
    • 2019
  • Ocean reverberation is the most limiting factor in designing realistic and real-time system for sonar simulator. The simulation for an ocean reverberation requires a lot of computational loads, so it is hard to embed program and generate real-time signal in the sonar simulator. In this study, we simulate a time-domain bottom reverberation signal based on Harrison's energy-flux bottom reverberation model by applying Doppler effects as ship maneuvering and autoregressive model. Finally, the bottom reverberation signal with realistic characteristics could be generated for the simulation of ONR reverberation modeling workshop-I problem XI and East Sea ocean environments.

Geosynchronous Relativistic Electron Events Associated with High-Speed Solar Wind Streams in 2006 (2006년 발생한 고속 태양풍과 관련된 정지궤도에서의 상대론적 전자 증가 이벤트)

  • Lee, Sung-Eun;Hwang, Jung-A;Lee, Jae-Jin;Cho, Kyung-Suk;Kim, Khan-Hyuk;Yi, Yu
    • Journal of Astronomy and Space Sciences
    • /
    • v.26 no.4
    • /
    • pp.439-450
    • /
    • 2009
  • Recurrent enhancements of relativistic electron events at geosynchronous orbit (GREEs) were observed in 2006. These GREE enhancements were associated with high-speed solar wind streams coming from the same coronal hole. For the first six months of 2006, the occurrence of GREEs has 27 day periodicity and the GREEs were enhanced with various flux levels. Several factors have been studied to be related to GREEs: (1) High speed stream, (2) Pc5 ULF wave activity, (3) Southward IMF Bz, (4) substorm occurrence, (5) Whistler mode chorus wave, and (6) Dynamic pressure. In this paper, we have examined the effectiveness about those parameters in selected periods.

Micro fluxgate magnetic sensor using multi layer PCB process (PCB 다층 적층기술을 이용한 마이크로 플럭스게이트 자기 센서)

  • Choi, Won-Youl;Hwang, Jun-Sik;Choi, Sang-On
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.72-78
    • /
    • 2003
  • To observe the effect of excitation coil pitch on the micro fluxgate magnetic sensor, two sensors are fabricated using multi layer board process and the pitch distance of excitation coil are $260\;{\mu}m$ and $520\;{\mu}m$, respectively. The fluxgate sensor consists of five PCB stack layers including one layer of magnetic core and four layers of excitation and pick-up coils. The center layer as magnetic core is made of a Co-based amorphous magnetic ribbon with extremely high DC permeability of ${\sim}100,000$ and has a rectangular-ring shape to minimize the magnetic flux leakage. Four outer layers as excitation and pick-up coils have a planar solenoid structure and are made of copper foil. In case of the fluxgate sensor having the excitation coil pitch of $260\;{\mu}m$, excellent linear response over the range of $-100\;{\mu}T$ to $+100\;{\mu}T$ is obtained with sensitivity of 780 V/T at excitation sine wave of $3V_{p_p}$ and 360 kHz. The chip size of the fabricated sensing element is $7.3\;{\times}\;5.7\;mm^2$. The very low power consumption of ${\sim}8\;mW$ is measured. This magnetic sensor is very useful for various applications such as: portable navigation systems, telematics, VR game and so on.

A Study on the Fabrication and Electromagnetic Characteristics of High Tc Superconductor Using Pyrosis method for Electrical Equipment (열분해법에 의한 전력기기용 고온 초전도체의 합성 기술 및 전기 자기적 특성)

  • Lee, Sang-Heon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.453-456
    • /
    • 2005
  • We have fabricated superconducting ceramics by chemical process. A high Tc superconducting with a nominal composition of YBaCuO was prepared by the pyrolysis method. The electromagnetic properties in YBaCuO superconductor was studied. In the measurement of current-voltage characteristics, a voltage across the superconducting sample was observed on applying an external magnetic field. The voltage increases with increase in applied magnetic flux, but it becomes constant at about 10$^{-2}$T. The voltage continues to appear the removal of the magnetic field. The appearance of the voltage is ascribed to the trapping of magnetic flux. Depending on the direction of applied magnetic flux less than 2.5$\times$10$^{-5}$ T, the voltage in the magnetized sample increases or decreases.

Inspection of Non-metallic Inclusions in Thin Steel Sheets Using Magnetic Flux Leakage Method (누설자속법을 이용한 박강판의 결함탐상)

  • 임종수;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.6
    • /
    • pp.302-309
    • /
    • 2000
  • An MFL (Magnetic Flux Leakage) testing system has been developed in order to inspect the non-metallic inclusions in the thin steel sheets. We have made a differential type flux-gate magnetometer using the measurement of apparent coercive field strength of soft magnetic core. The specifications of the electromagnet was determined using FEM software, and MFL testing system with 3 axis degree of freedom was constructed. The feasibility testing for non-metallic inclusion was shown using the system. By digitizing MFL signal and using 2-D graphic display, we could identify various surface defects other than the inclusions.

  • PDF