• Title/Summary/Keyword: 자기 이완

Search Result 129, Processing Time 0.025 seconds

Investigation of Temperature Dependence for CNT Semiconductor in External Magnetic Field (외부 자기장내의 반도체 CNT의 온도의존 조사)

  • Park, Jung-Il;Lee, Haeng-Ki
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.3
    • /
    • pp.73-78
    • /
    • 2012
  • We calculated the electron spin resonance (ESR) line-profile function. The line-width of single-walled carbon nanotube (SWNT) was studied as a function of the temperature at a frequency of 9.5 GHz in the presence of external electromagnetic radiation. The temperature dependence of the line-widths is obtained with the projection operator method (POM) proposed by Argyres and Sigel. The scattering is little affected in the low-temperature region (T < 200 K). We conclude that the calculation process presented in this method is useful for optical transitions in SWNT.

T1-, T2-weighted, and FLAIR Imaging: Clinical Application (T1, T2강조영상, FLAIR영상의 임상 적용)

  • Kim, Jae-Hyoung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • T1-, and T2-weighted imagings and FLAIR (fluid attenuated inversion recovery) imaging are fundamental imaging methods in the brain. T1-weighted imaging is a spin-echo sequence with short TR and short TE and produces the tissue contrast by different T1 relaxation times. In other words, short TR maximizes the difference of the longituidinal magnetization recovery between the tissues. T2-weighted imaging is a spin-echo sequence with long TR and long TE and produces the tissue contrast by different T2 relaxation times. Long TE maximizes the difference of the transverse magnetization decay between the tissues. FLAIR is an inversion recovery sequence using 180 degree inversion pulse. 2500 msec of inversion time is applied to suppress the CSF signal.

  • PDF

Comparison of Proton T1 and T2 Relaxation Times of Cerebral Metabolites between 1.5T and 3.0T MRI using a Phantom (모형을 이용한 1.5T와 3.0T 자기공명에서의 뇌 대사물질들의 수소 T1과 T2 이완시간의 비교)

  • Kim, Ji-Hoon;Chang, Kee-Hyun;Song, In-Chan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.1
    • /
    • pp.20-26
    • /
    • 2008
  • Purpose : To present the T1 and T2 relaxation times of the major cerebral metabolites at 1.5T and 3.0T and compare those between 1.5T and 3.0T. Materials and Methods : Using the phantom containing N-acetyl aspartate (NAA), Choline (Cho), and Creatine (Cr) at both 1.5T and 3.0T MRI, the T1 relaxation times were calculated from the spectral data obtained with 5000 ms repetition time (TR), 20 ms echo time (TE), and 11 different mixing time (TM)s using STEAM (STimulated Echo-Acquisition Mode) method. The T2 relaxation times were obtained from the spectral data obtained with 3000 ms TR and 5 different TEs using PRESS (Point-RESolved Spectroscopy) method. The T1 and T2 relaxation times obtained at 1.5T were compared with those of 3.0T. Results : The T1 relaxation times of NAA were $2293\;{\pm}\;48\;ms$ at 1.5T and $2559\;{\pm}\;124\;ms$ at 3.0T (11.6% increase at 3.0T). The T1 relaxation times of Cho were $2540\;{\pm}\;57\;ms$ at 1.5T and $2644\;{\pm}\;76\;ms$ at 3.0T (4.1% increase at 3.0T). The T1 relaxation times of Cr were $2543\;{\pm}\;75\;ms$ at 1.5T and $2665\;{\pm}\;94\;ms$ at 3.0T (4.8% increase). The T2 relaxation times of NAA were $526\;{\pm}\;81\;ms$ at 1.5T and $468\;{\pm}\;74\;ms$ at 3.0T (11.0% decrease at 3.0T). The T2 relaxation times of Cho were $220\;{\pm}\;44ms$ at 1.5T and $182\;{\pm}\;35\;ms$ at 3.0T (17.3% decrease at 3.0T). The T2 relaxation times of Cr were $289\;{\pm}\;47\;ms$ at 1.5T and $275\;{\pm}\;57\;ms$ at 3.0T (4.8% decrease at 3.0T). Conclusion : The T1 relaxation times of the major cerebral metabolites (NAA, Cr, Cho), which were measured at the phantom, were 4.1%-11.6% longer at 3.0T than at 1.5T. The T2 relaxation times of them were 4.8%-17.3% shorter at 3.0T than at 1.5T. To optimize MR spectroscopy at 3.0T, TR should be lengthened and TE should be shortened.

  • PDF

Evaluation of Internal Structure of Beef Using Magnetic Resonance Imaging (자기공명영상을 이용한 소고기의 내부 구조 평가)

  • Kim, S. M.
    • Journal of Biosystems Engineering
    • /
    • v.24 no.6
    • /
    • pp.531-538
    • /
    • 1999
  • 비파괴 품질 평가 기술인 핵 자기공명 분광법과 자기공명영상을 이용하여 소고기의 내부 구조를 분석하였다. 이완 상수 T$_1$과 T$_2$가 육류의 내부 구조와 관계가 있음을 보였다. 근육부분의 면적 비율이 증가할수록 T$_1$이 증가했다. 지방 부분의 T$_2$는 배 내부 부분의 T$_2$와 비슷한 값을 보였다. 자기공명 영상을 이용하여 육류의 원하는 부위의 T$_2$를 측정할 수 있는 방법을 구하였다. 근육 부분의 T$_2$가 길었으며 지방 부분의T$_2$가 짧았다. 부위별로 최적의 신호를 얻을 수 있는 자기공명영상 인자 TR과 TE를 구하였다. 자기공명영상을 이용하여 근육, 지방 그리고 뼈 성분에 따른 육류의 품질을 비파괴적으로 평가할 수 있는 가능성을 보여주었다.

  • PDF

Development and Practical Application of Relaxation Training Contents for Middle and High School Archery Players (중.고교 양궁선수용 이완훈련 콘텐츠 개발 및 현장 적용)

  • Hong, Kil-Dong
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.4
    • /
    • pp.237-246
    • /
    • 2008
  • The purpose of this study was to develop relaxation training contents for middle and high school archery players with considering the ecological validity of social, cultural, and sports environment in Korean but also examine the effect of developing relaxation training contents through case study approach and interviews. The relaxation training contents was based on previous researches about relaxation program. In addition, in order to develop the program 3 archery experts and 2 sport psychologists had meetings. The relaxation training contents categorized as orientation, breathing regulation, progressive relaxation training, cognitive restructuring, meditation, heart rate biofeedback training, autogenic training, behavior therapy, self regulation. The experimental group were 6 male Korean national archery substitute players, who were selected in 2007. The effects was examined on competitive state anxiety inventory-2, heart rates, archery score and interviews. As the result of applying the developed program of this study on the field, competitive state anxiety, somatic state anxiety and heart rate were decreased. In the interviews athletes told that they were relaxed psychologically and physically. This result demonstrated the relaxation training program were effective.

The Synthesis and MR Properties of New Macromolecular MR Contrast Agent (새로운 거대분자 MR 조영제의 합성 및 MR 특성에 관한 연구)

  • 장용민;장영환;황문정;박현정;전경녀;이종민;배경수;강봉석
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.35-40
    • /
    • 2002
  • Purpose : To evaluate the NMR relaxation properties and imaging characteristics of tissue-specificity for a newly developed macromolecular MR agent. Materials and methods : Phthalocyanine (PC) was chelated with paramagnetic ion, Mn.2.01g (5.2 mmol) of Phthalocyanine was mixed with 0.37g (1.4 mmol) of Mn chloride at $310^{\circ}C$ for 36 hours and then purified by chromatography (CHC13/CH3OH 98/2 v/v, Rf, 0.76) to obtain 1.04g (46%) of MnPC (molecular weight= 2000d). The $T1}T2$ relaxivity of MnPC was measured in 1.5T(64 MHz) MR using 0.1 mM MnPC. The MR image characteristics of MnPC was evaluated using spin-echo (TR/TE=500/14 msec) and gradient-echo (FLASH) (TR/TE=80/4 msec, flip angle=60) techniques in 1.57 MR scanner. The images of rabbit liver were obtained every 10 minutes up to 4 hours. To study the effect of concentration on image, 20 mM, 50 mM, 100 mM of MnPC were tested. Results : The relaxivities of MnPC at 1.5T(64MHz) were Rl=7.28 $mM^{-1}S^{-1},{\;}R2=55.56mM^{-1}S^{-1}$. Compared to the values of Gd-DTPA (Rl[=4.8 $mM^{-1}S^{-1})$], R2[=5.2 $mM^{-1}S^{-1}])$]), both T1/T2 relaxivities of MnPC were higher than those of Gd-DTPA. For both of SE and FLASH techniques, the contrast enhancement reached maximum at 10 minutes after bolus injection and the enhancement continued for more than 2 hours. When compared with small molecular weight liver agents such as Gd-EOB-DTPA, Gd-BOPTA and MnDPDP, MnPC was characterized by more prolonged enhancement time. The time course of MR images also revealed biliary excretion of MnPC. Conclusion : We developed a new macromolecular MR agent, MnPC. The relaxivities of MnPC were higher than those of small molecular weight Gd-chelate. Hepatic uptake and biliary excretion of MnPC suggests that this agent is a new liver-specific MR agent.

  • PDF

The Effects of Self-Efficacy Promoting Pulmonary Rehabilitation Program in Out-Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환 외래환자에서 자기효능감증진 호흡재활프로그램의 효과)

  • Jung, Jang Hee;Kim, Jung Youp
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.6
    • /
    • pp.533-546
    • /
    • 2006
  • Background: The aim of this study was to determine the effectiveness of self-efficacy promoting pulmonary rehabilitation in patients with chronic obstructive pulmonary disease (COPD). Methods: thirty six patients, with clinically stable COPD were randomly assigned: 18 to a rehabilitation group and another 18 as a control group, The subjects participated in a the self-efficacy promoting pulmonary rehabilitation program for 8 weeks. This program consisted of education, breathing retraining, exercise training, relaxation and counseling. The control group received education only. The outcome variables were self-efficacy, dyspnea, exercise endurance, pulmonary function, and quality of life. Dyspnea was measured using the modified Borg scale. Exercise endurance was measured by the six minute walking distance. The quality of life was measured by the quality of life index for pulmonary disease patients. Results: In the rehabilitation group after performing the self-efficacy promoting pulmonary rehabilitation program, the self-efficacy score, exercise endurance, and quality of life score were higher than the control group (p=0.007, p=0.038, and p=0.039, respectively). and the exertional dyspnea score was significantly lower than controls(p=0.045). However, the dyspnea score and FEV1 were similar after performing the self-efficacy promoting pulmonary rehabilitation program. Conclusion: The self-efficacy promoting pulmonary rehabilitation program is effective to in improve self-efficacy, exertional dyspnea, exercise endurance and quality of life in patients with COPD.

Efficient Self-supervised Learning Techniques for Lightweight Depth Completion (경량 깊이완성기술을 위한 효율적인 자기지도학습 기법 연구)

  • Park, Jae-Hyuck;Min, Kyoung-Wook;Choi, Jeong Dan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.6
    • /
    • pp.313-330
    • /
    • 2021
  • In an autonomous driving system equipped with a camera and lidar, depth completion techniques enable dense depth estimation. In particular, using self-supervised learning it is possible to train the depth completion network even without ground truth. In actual autonomous driving, such depth completion should have very short latency as it is the input of other algorithms. So, rather than complicate the network structure to increase the accuracy like previous studies, this paper focuses on network latency. We design a U-Net type network with RegNet encoders optimized for GPU computation. Instead, this paper presents several techniques that can increase accuracy during the process of self-supervised learning. The proposed techniques increase the robustness to unreliable lidar inputs. Also, they improve the depth quality for edge and sky regions based on the semantic information extracted in advance. Our experiments confirm that our model is very lightweight (2.42 ms at 1280x480) but resistant to noise and has qualities close to the latest studies.

Automatic Left Ventricle Segmentation on Cardiac Magnetic Resonance Image (심장 자기공명영상에서의 좌심실 자동 분할 알고리즘)

  • Jo, Hyun Wu;Lee, Hae-Yeoun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.11a
    • /
    • pp.561-564
    • /
    • 2010
  • 의학과 기술 발달로 인해 질병과 사고에 의한 사망률은 줄어들었으나, 심장 관련 질환에 의한 사망률은 증가하였다. 심장 질환을 예방하는 데는 정기적인 검진을 통해 심장기능을 분석하고 관찰하는 것이 중요하다. 심장 기능의 분석은 이완기와 수축기 사이의 혈류량 및 심박구출률 계산을 통한 심장 운동능력 평가에 의해 이루어진다. 본 연구에서는 심장 단축 자기공명영상에서 좌심실 영역을 자동 분할하여 혈류량 및 심박 구출률을 계산하는 알고리즘을 제안한다. K평균 군집화 기법을 적용하여 좌심실을 분할하고, 그래프 탐색 기법에 기반하여 분할 오류를 수정하였다. 15명의 지원자에 대해 제안하는 알고리즘을 사용하여 혈류량과 심박구출률을 계산하였고, 수동윤곽검출 및 General Electronics 사의 MASS 소프트웨어와 비교하였다. 제안한 알고리즘의 수동윤곽검출과 차이는 혈류량의 경우 평균적으로 이완기에 $4.6mL{\pm}3.9$, 수축기에 $2.1mL{\pm}2.4$로 나타났고, 심박구출률은 $1.8%{\pm}1.7$이었다. 전반적으로 MASS소프트웨어에 비해 좋은 성능을 나타내었다.