• Title/Summary/Keyword: 자기장 해석

Search Result 286, Processing Time 0.028 seconds

Estimation of Radial Spectrum for Orographic Storm (산지성호우의 환상스팩트럼 추정)

  • Lee, Jae Hyoung;Sonu, Jung Ho;Kim, Min Hwan;Shim, Myung Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.53-66
    • /
    • 1990
  • Rainfall is a phenomenon that shows a high variability both in space and time, Hy drologists are usually interested in the description of spatial distribution of rainfall over watershed. The theory of Kriging, generalized covariance technique using nonstationary mean in the regions under orographic effect, was chosen to construct random surface of total storm depth. For the constructed random surface, the double Fourier analysis of the total storm depths was performed, and the principal harmonics of storm were determined. The local component, or storm residuals was obtained by subtracting the periodic component of the storm from total storm depths. It is assumed that the residuals are a sample function of a homogeneous random field. This random field can be characterized by an isotropic one dimensional autocorrelation function or its corresponding spectral density function. Under this assumption, this study proposed a theorectical model for spectral density function adapted to two watersheds.

  • PDF

Analysis and Design of Micro Solenoid (마이크로 솔레노이드의 해석 및 설계)

  • Jeon, Y.S.;Bae, S.K.;Kim, D.S.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.4
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

Fiber-Optic Current Transformer for the Over Current Protection Relay (과전류 보호계전기용 광섬유 전류센서)

  • Song, Min-Ho;Yang, Chang-Soon;Ahn, Seong-Joon;Park, Byoung-Seok;Lee, Byoung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.542-548
    • /
    • 2001
  • A robust, accurate, broad-band, alternating current sensor using fiber-optics is being developed as a part of optical over current protection relay system. The sensor uses the Faraday effect in optical fiber and polarimetric measurements tc sense electrical current. The current sensing coil consists of a length of twisted optical fiber and Faraday rotator mirror to suppress the linear birefringence effect. Due to its single-ended closed path structure, it can not only be easily installed to the target with great isolation from other fields in the vicinity, but the sensitivity can be increased by using multiple turns. This paper reports on the theoretical backgrounds of the sensor design and the preliminary experimental results.

  • PDF

MT surveys near Century Zinc Mine, NW Queensland, Australia (호주 Century 아연 광산에서의 MT 탐사)

  • Lee, Tae-Jong;Lee, Seong-Kon;Song, Yoon-Ho;Cull, James
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.345-352
    • /
    • 2007
  • Two-dimensional (2D) MT surveys near the Century mine in Australia have been performed with very far remote reference in Esashi, Japan (RR_ESS) as well as Gregory Downs (RR_GREG), which are roughly 6,400 km and 80 km apart from the survey area, respectively. Good quality of MT data could be obtained by remote reference processing with RR_GREG, while the coherency of magnetic fields between field sites and RR_ESS was not sufficient to be used as remote data. Both 2D and 3D inversion of 2D profile data represented the general geological structure beneath the survey area. The main target of the survey, Termite Range Fault, appeared as a boundary between a conductive block to the north and a resistive block to the south in the reconstructed resistivity section, and is inclined slightly to the north-east direction.

Analysis of Pole Ratio Effect of Magnetic Reducer (마그네틱 감속기의 극수비 영향 분석)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.277-283
    • /
    • 2020
  • In a concentric magnetic gear, which replaces the teeth of a mechanical gear with a permanent magnet, the polar ratio of the magnet that determines the reduction ratio affects the behavior of the magnetic gear dramatically. This study analyzed the density of transmission torque, the efficiency of torque considering the solid loss, and the torque quality, including the cogging characteristics using finite element analysis. When the pole number on the driving side was changed from two to five, it was confirmed that there was an optimal pole ratio, in which the transmission torque was maximized. Because eddy current generation density is proportional to the magnetic field, the transmission efficiency also shows a similar tendency to the transmission torque density, and the efficiency is more than 95% at a low gear ratio. The cogging characteristics due to the interaction of the permanent magnets with the limited number of poles are inversely proportional to the least common multiple between the number of magnets on the drive side and the number of modulator teeth. A test model was built for the transmission torque evaluation.

FEA and Model test of Backfill Materials for Underground Facility with Recycling Materials (재활용 재료를 이용한 지하 매설물용 뒤채움재의 모형시험 및 유한요소해석)

  • Lee, Kwan Ho;Kim, Sung Kyum
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.177-177
    • /
    • 2011
  • 현재 대부분 사용되는 지하매설물용 뒤채움재는 다짐공법을 많이 사용하고 있으며, 실제로 이러한 방법은 부적절한 다짐으로 인해 침하 및 내구성 저하로 인해 파손을 초래하는 경우가 많다. 이러한 문제를 해결 할 수 있는 하나의 대안으로 유동성 뒤채움재를 이용할 수 있다. 유동성 뒤채움재는 초기 유동성, 시간에 따른 자기 강도 발현 무다짐공법 적용 등 많은 장점을 가지고 있다. 본 연구에서는 현장발생토사, 정수장슬러지 및 폐타이어분말 등 재활용 재료를 이용한 유동성 뒤채움재의 기본물성을 평가하였다. 각각의 재활용재료에 대한 입도 및 비중을 평가하였고, 최적배합설계를 결정하였으며, 모형 시험과 유한요소 해석을 위한 기본 물성값을 위해 일축압축시험, 삼축압축시험, 공진주시험 등을 수행하였다. 최적배합설계를 산정하는 과정에서 수행한 실험중 대표적인 시험으로 자가수평능력 및 자기다짐등에 필요한 유동성을 판단하는 Flow시험(ASTM D 6133) 결과 기준으로 정한 20cm이상의 값을 얻을 수 있었으며 일축압축강도의 경우 시공 후 유지 보수가 용이한 강도인 $3.0kg/cm^2{\sim}5.6kg/cm^2$이하로 설계하였으며 28일재령 일축압축강도 결과 $3.15{\sim}3.74kg/cm^2$라는 유지보수에 적당한 결과값을 나타내었다. 이 배합이 현장에서 사용이 가능하다는 것으로 판단하고 현장모형시험과 유한요소해석를 통하여 현장에서 사용하였을 때 관의 변형과 관에 작용하는 하중변화를 확인하고 현장모형시험과 유한요소해석 간의 상관관계를 규명하였다. 현장 모형 시험은 현장과 비슷하게 제작된 모형을 이용하였으며 최대한 현장과 비슷한 조건에서 뒤채움재를 타설과정 중과 타설이 완료된 상태에서 7일 양생 후 하중재하와 같이 두가지 경우에서 수직 수평토압, 관의 수직 수평변위, 관의 종단변형을 측정하였다. 유한요소해석 프로그램은 Midas GTS를 이용하여 실시하였으며 관의 변형률, 유효응력을 측정하여 규명하였다.

  • PDF

Response Variability of Laminated Composite Plates with Random Elastic Modulus (탄성계수의 불확실성에 의한 복합적층판 구조의 응답변화도)

  • Noh, Hyuk-Chun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.4
    • /
    • pp.335-345
    • /
    • 2008
  • In this study, we suggest a stochastic finite element scheme for the probabilistic analysis of the composite laminated plates, which have been applied to variety of mechanical structures due to their high strength to weight ratios. The applied concept in the formulation is the weighted integral method, which has been shown to give the most accurate results among others. We take into account the elastic modulus and in-plane shear modulus as random. For individual random parameters, independent stochastic field functions are assumed, and the effect of these random parameters on the response are estimated based on the exponentially varying auto- and cross-correlation functions. Based on example analyses, we suggest that composite plates show a less coefficient of variation than plates of isotropic and orthotropic materials. For the validation of the proposed scheme, Monte Carlo analysis is also performed, and the results are compared with each other.

A study of the defect detecting method in the NDT gauge using the permanent Magnetics (영구자석을 이용한 비파괴 검사기의 결함검출 기법에 관한 연구)

  • Park, Il-Hwan;Cho, Ji-Eung;Jo, Bong-Kyun;Lee, Geun-Bo;Kim, Deok-Geon;Hong, Young-Hwan;Park, Chi-Young;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.597-598
    • /
    • 2006
  • 자기누설탐상법은 비파괴검사 방법의 하나로 대상물체를 외부에서 착자시켜 결함이 발생할 경우에 결함부위에서 자기누설이 발생하도록 하여, 누설된 자기장을 측정하여 결함의 유무와 크기 등을 판정하는 시스템이다. 본 논문에서는 MFL 방식의 범용 NDT 검사기의 개발을 위해 영구자석을 이용하여 소형 비파괴 검사기를 설계하고, 3차원 유한요소법을 이용하여 해석하고 실제 데이터를 측정하여 그 결과를 비교 분석하였다.

  • PDF

A study of the defect detecting method in the NDT gauge using the permanent Magnetics (영구자석을 이용한 비파괴 검사기의 결함검출 기법에 관한 연구)

  • Park, Il-Hwan;Cho, Ji-Eung;Jo, Bong-Kyun;Lee, Geun-Bo;Kim, Deok-Geon;Hong, Young-Hwan;Park, Chi-Young;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2229-2230
    • /
    • 2006
  • 자기누설탐상법은 비파괴검사 방법의 하나로 대상물체를 외부에서 착자시켜 결함이 발생할 경우에 결함부위에서 자기누설이 발생하도록 하여, 누설된 자기장을 측정하여 결함의 유무와 크기 등을 판정하는 시스템이다. 본 논문에서는 MFL 방식의 범용 NDT 검사기의 개발을 위해 영구자석을 이용하여 소형 비파괴 검사기를 설계하고, 3차원 유한요소법을 이용하여 해석하고 실제 데이터를 측정하여 그 결과를 비교 분석하였다.

  • PDF

A study of the defect detecting method in the NDT gauge using the permanent Magnetics (영구자석을 이용한 비파괴 검사기의 결함검출 기법에 관한 연구)

  • Park, Il-Hwan;Cho, Ji-Eung;Jo, Bong-Kyun;Lee, Geun-Bo;Kim, Deok-Geon;Hong, Young-Hwan;Park, Chi-Young;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1263-1264
    • /
    • 2006
  • 자기누설탐상법은 비파괴검사 방법의 하나로 대상물체를 외부에서 착자시켜 결함이 발생할 경우에 결함부위에서 자기누설이 발생하도록 하여, 누설된 자기장을 측정하여 결함의 유무와 크기 등을 판정하는 시스템이다. 본 논문에서는 MFL 방식의 범용 NDT 검사기의 개발을 위해 영구자석을 이용하여 소형 비파괴 검사기를 설계하고, 3차원 유한요소법을 이용하여 해석하고 실제 데이터를 측정하여 그 결과를 비교 분석하였다.

  • PDF