• Title/Summary/Keyword: 자기장 측정

Search Result 531, Processing Time 0.039 seconds

Study on the Linear Magnetic Field Sensor Using ΔE in Amorphous Ribbon (비정질 리본의 ΔE 특성을 이용한 선형 자기센서에 관한 연구)

  • Park, S.Y.;Kim, C.G.;Ryu, K.S.;Kim, D.Y.
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.205-208
    • /
    • 2013
  • The width dependence of Delta E has been studied by impedance resonance method in Fe-rich amorphous ribbon of as received state. It can be explained by single domain model include effective magnetic field $H_{eff}$ and demagnetization factor $N_d$. Wider width ribbon's effective is smaller than narrow it. Young's modulus also smaller than narrow width. These result well agreement in calculation. It has been also studied that linear magnetic field sensor using width dependence of Delta E under the field range 0 Oe~80 Oe. The sensitivity of the sensor was found to be 95 Hz/Oe.

Research of Pumping Force according to Shape of Magnetic Fluid in Magnetic Fluid Linear Pump (자성유체의 형상에 따른 선형 펌프의 펌핑력에 관한 연구)

  • Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.981-983
    • /
    • 2005
  • 자성유체를 이용하여 동작하는 선형 펌프를 개발하였다. 자성유체의 자기적 성질을 이용하여 구동하는 선형펌프로 일반 펌프에 비해 조가 간단하고, 진동/소음이 작다는 장점이 있다. 또한 외부에서 인가하는 자기장의 조절만으로 펌프를 조절할 수 있다. 개발한 펌프는 자성유체의 관내에서의 형상에 따라 펌핑력이 매우 달라진다. 따라서 외부에서 인가하는 자기장에 의해 형성되는 자성유체의 형상을 해석하고, 이로 인해 형성되는 자성유체에 의해 발생하는 펌핑력을 측정하고 비교하였다.

  • PDF

Digital Infrared Thermographic Imaging(DITI) analysis by micro-magnetic stimulation for muscle fatigue recovery and muscle pain control (근피로 회복 및 근통증 완화를 위한 미약 자기장 자극에 대한 체열변화 분석)

  • Kim, Soo-Byung;Lee, Na-Ra;Lee, Seung-Wook;Lee, Kyong-Joung;Lee, Yong-Heum
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.7
    • /
    • pp.1653-1660
    • /
    • 2010
  • In this study, change of body surface temperature was measured using Digital Infrared Thermographic Imaging(DITI) to check muscle fatigue recovery & muscle pain control by magnetic stimulations. For clinical trials, subjects were divided into 3 groups : non stimulation group(NSG), electrical stimulation group(ESG) and micro magnetic stimulation group(MSG). In result, temperature differences between left and right arm surfaces were measured as much as $0.86{\pm}0.43^{\circ}C$(n=96) after the exercise, $0.78{\pm}0.12^{\circ}C$ after the electrical stimulation and $0.1{\pm}0.39^{\circ}C$ after the micro magnetic stimulation. Also after 3days, temperature differences between left and right arm surfaces were measured as much as $0.3{\pm}0.14^{\circ}C$ in the NSG, $0.05{\pm}0.21^{\circ}C$ in the ESG and $0.03{\pm}0.21^{\circ}C$ in the MSG. These data showed that the lowest temperature difference between left/right body surface was measured in MSG.

A Review on nuclear magnetic resonance logging: fundamental theory and measurements (자기공명검층: 기본 이론 및 자료 측정)

  • Jang, Jae Hwa;Nam, Myung Jin
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.235-244
    • /
    • 2012
  • Nuclear magnetic resonance (NMR) logging has been considered one of the most complicated nevertheless, one of the most powerful logging methods for the characterization on of both rocks and natural fluids in formation. NMR measures magnetized signals (polarization and relaxation) between the properties of hydrogen nucleus called magnetic moment and applied magnetic fields. The measured data set contains two important petrophysical properties such as density of hydrogen in the fluids inside the pore space and the distinct decay rate for fluid type. Therefore, after the proper data processing, key petrophysical information, not only the quantities and properties of fluids but also supplies of rock characterization in a porous medium, could be archived. Thus, based on this information, several ongoing researches are being developed in estimating aspects of reservoir productivity information, permeability and wettability since it is the key to having correct interpretation. This study goes through the basic theory of NMR at first, and then reviews NMR logging tools as well as their technical characteristics. This paper also briefly discusses the basic knowledge of NMR simulation algorithm by using Random walk.

Magnetic Anisotropy in High $T_c\;Y_1Ba_2Cu_3O_{7-y}$ Superconductor (고온초전도체 $Y_1Ba_2Cu_3O_{7-y}$의 자기이방성)

  • Kim, Mun-Seok;Yu, Seong-Cho;Im, U-Yeong;Baek, Jong-Seong
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.3
    • /
    • pp.228-232
    • /
    • 1992
  • Magnetic properties of grain aligned high $T_c\;Y_1Ba_2Cu_3O_{7-y}$ superconductor are inverstigated. Grain-aligned superconductors have magnetic anisotropy in the Cu-O layer like single crystals. The lower critical field $H_{c1},$ measured at the temperature range of 2 K up to 77 K, is found to be decreasing linearly as temperature goes up. Moreover, it decreaes more rapidly when the Cu-O layer is perpendicular to the external magnetic field. The temperature dependence of the magnetic susceptibility shows that the value of magnetic susceptibility, $4{\pi}\;X,$ is close to -1 at low temperature. The intra grain critical current density $J_c,$ obtained from the Bean's critical state model, is found to be comparable to that of single crystal superconductors.

  • PDF

Design of Miniaturized Magnetic Field Probe for Measurement of IC Surface Current Distribution (IC 표면 전류 분포 측정을 위한 초소형 자기장 프로브 설계)

  • Lee, Seung-Bae;Jeon, Young-Hyun;Kim, Byung-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.5
    • /
    • pp.154-161
    • /
    • 2009
  • Recently, as many functional blocks are integrated on a small area the high speed integrated circuits emerge as a critical electromagnetic interferer which causes mal-function of adjacent circuitries and lowers the sensitivity of the wireless receivers. Therefore, it is necessary to devise an precise analyzing tool to pinpoint the major electromagnetic noise contributor among the internal circuit blocks of high speed IC's. This paper presents the design, fabrication, and measurement results of the high resolution magnetic field probe which can measure the current density on the IC surface. In order to achieve the high resolution, the magnetic field probe is fabricated using 3-metal semiconductor process so that its thickness is reduced by 10% than that of conventional works. Through the magnetostatic analysis and EM simulation, spatial resolution and sensitivity to the nonmagnetic field components are analyzed. Experimentally, it is found that the fabricated probe can measure the current density on the IC surface with $210{\mu}m$-spatial-resolution.

Magnetic-plethysmograph system development for real-time blood pressure estimate (실시간 혈압 추정을 위한 자계용적맥파 시스템 개발)

  • Kang, Seung-Jin;Lee, Kang-Hwi;Lee, Young-Jae;Kim, Kyeung-Nam;Lee, Jeong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1401-1402
    • /
    • 2015
  • 급작스레 발병하는 혈관 질환으로 인해 실시간 혈압 추정 연구가 많이 진행되어지고 있다. 본 논문에서는 자기장을 이용하여 혈압을 추정할 수 있는 자계용적맥파 시스템을 개발하였다. 자기장을 이용한 방법은 온도에 강하며 혈류와 상관성이 있기에 사용하였다. 혈압 추정의 과정은 총 3부분 나눌 수 있다. MPG측정, ECG측정 그리고 신호처리 부분이며 신호처리는 PC에서 디지털 필터링 및 PTT 계산을 실시하게 된다. 비교 기준 혈압으로 Omron 혈압계를 사용하여 동시 측정하였으며 결과로 각 PTT간 기준 수축기 및 이완기 혈압을 비교 할 수 있었다.

  • PDF

Effects of Demagnetization Field in Patterned Micro-magnetic Film Elements (패턴 된 미크론 자기박막 소자에서의 자기소거장 효과분석)

  • Kim, Ki-Chul;Suh, Jeong-Dae;;Lee, C.S.;Song, Y.J.
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.3
    • /
    • pp.103-108
    • /
    • 2003
  • A micromagnetic model and a Stoner-Wohlfarth model are used to analyze the effect of demagnetization field in patterned permalloy films. Permalloy films of 20 $\mu\textrm{m}$${\times}$(40 $\mu\textrm{m}$∼200 $\mu\textrm{m}$) are fabricated by DC magnetron sputtering and photo lithography. Measured magnetoresistance data of patterned permalloy films are compared with simulation results. The micromagnetic model gives a better agreement with the measured MR data than the Stoner-Wohlfarth model. Based on the simulation results, we propose a revised approximation formula for dernagnetization field in Stoner- Wohlfarth model for a few fm patterned magnetic films.

Analysis of Underwater Earth Field Anomaly Generated by a Ship (함정에 의해 발생되는 수중 지자계 외란신호 해석)

  • Lee, Kang-Jin;Yang, Chang-Seop;Jung, Hyun-Ju;Kim, Dong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.882-883
    • /
    • 2007
  • 본 논문에서는 지자계에 노출된 함정의 유도자화에 의한 자기장 성분을 분석하는 방법을 제시하였다. 우선 모델함정을 제작하여 지자계에 노출시킨 상태에서 왕복실험을 수행하고 이때 측정되는 데이터를 수집하여 함정의 수평방향으로 유도되는 자기장성분을 분리하였다. 또한 정밀 수치해석기법을 통해 측정치와 비교함으로서 정밀 수치해석 기법에 의한 예측값의 신뢰성을 확인하였다. 따라서 본 연구결과는 함정 재질 상에 분포하는 유도자화 및 영구자화에 의한 자기장의 거동을 예측함으로서 함정의 자기정숙화(magnetic silent)연구에 중요한 기초 자료로 활용될 것으로 사료된다.

  • PDF

백색 LED증착용 MOCVD 유도가열 장치에서 가스 inlet위치에 따른 기판의 온도 균일도 측정

  • Hong, Gwang-Gi;Yang, Won-Gyun;Ju, Jeong-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.115-115
    • /
    • 2010
  • 고휘도 고효율 백색 LED (lighting emitting diode)가 차세대 조명광원으로 급부상하고 있다. 백색 LED를 생산하기 위한 공정에서 MOCVD (유기금속화학증착)장비를 이용한 에피웨이퍼공정은 에피층과 기판의 격자상수 차이와 열팽창계수차이로 인하여 생성되는 에피결함의 문제로 기판과 GaN 박막층 사이에 완충작용을 해줄 수 있는 버퍼층 (Buffer layer)을 만든다. 그 위에 InGaN/GaN MQW (Multi Quantum Well)공정을 하여 고휘도 고효율 백색 LED를 구현 할 수 있다. 이 공정에서 기판의 온도가 불균일해지면 wafer 파장 균일도가 나빠지므로 백색 LED의 yield가 떨어진다. 균일한 기판 온도를 갖기 위한 조건으로 기판과 induction heater의 간격, 가스의 흐름, 기판의 회전, 유도가열코일의 디자인 등이 장비의 설계 요소이다. 본 연구에서는 유도가열방식의 유도가열히터를 이용하여 기판과 히터의 간격에 차이에 따른 기판 균일도 측정했고, 회전에 의한 기판의 온도분포와 자기장분포의 실험적 결과를 상용화 유체역학 코드인 CFD-ACE+의 모델링 결과와 비교 했다. 또한 가스의 inlet위치에 따른 기판의 온도 균일도를 측정하였다. 본 연구에서 사용된 가열원은 유도가열히터 (Viewtong, VT-180C2)를 사용했고, 가열된 흑연판 표면의 온도를 2차원적으로 평가하기 위하여 적외선 열화상 카메라 (Fluke, Ti-10)를 이용하여 온도를 측정했다. 와전류에 의한 흑연판의 가열 현상을 누출 전계의 분포로 확인하기 위하여 Tektronix사의 A6302 probe와 TM502A amplifier를 사용했다. 흑연판 위에 1 cm2 간격으로 211곳에서 유도 전류를 측정했다. 유도전류는 벡터양이므로 $E{\theta}$를 측정했으며, 이때의 측정 방향은 흑연판의 원주방향이다. 또한 자기장에 의한 유도전류의 분포를 확인하기 위하여 KANETEC사의 TM-501을 이용하여 흑연판 중심으로부터 10 mm 간격으로 자기장을 측정 했다. 저항 가열 히터를 통하여 대류에 의한 온도 균일도를 평가한 결과 gap이 3 mm일때, 평균 온도 $166.5^{\circ}C$에서 불균일도 6.5%를 얻었으며, 회전에 의한 온도 균일도 측정 결과는 2.5 RPM일 때 평균온도 $163^{\circ}C$에서 5.5%의 불균일도를 확인했다. 또한 CFD-ACE+를 이용한 모델링 결과 자기장의 분포는 중심이 높은 분포를 나타냄을 확인했고, 기판의 온도분포는 중심으로부터 55 mm되는 곳에서 300 W/m3로 가장 높은 분포를 나타냈다. 가스 inlet 위치를 흑연판 중심으로 수직, 수평 방향으로 흘려주었을 때의 불균일도는 각각 10.5%, 8.0%로 수평 방향으로 가스를 흘려주었을 때 2.5% 온도 균일도 향상을 확인했다.

  • PDF