• Title/Summary/Keyword: 자기장치

Search Result 944, Processing Time 0.026 seconds

Wearable Magnetic Sensor Device Using Wireless Sensor Network (무선센서 네트워크를 이용한 웨어러블 자기장 센서 장치)

  • Yeo, Hee-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.294-298
    • /
    • 2021
  • Recently, many electronic devices have been integrated with various kinds of wireless sensor network technologies that have been enabled with wireless network connections. These wireless sensor network devices have adopted various kinds of wireless network technologies. On the other hand, because each wireless network technology has its advantages and disadvantages, the target and purposes should be considered carefully at the beginning of the development. In particular, the approach to the magnetic sensor should be considered carefully because it has its own characteristic compared to general sensors. The magnetic field generates nonlinear data. This paper introduces the design aspects to reflect low cost and wearable devices to use in a wireless sensor network. In addition, this paper addresses how to select proper sensor network technology. As a result, wireless sensor network devices were integrated using Zigbee and showed the performance of the throughput.

Construction of an Earth's Field Compensation System for the Mcasurement of. Proton Gyromagnetic Ratio (양성자 자기회전비율 측정을 위한 지자장 상쇄장치 제작)

  • 우병칠;박포규;김철기;유권상;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.2 no.2
    • /
    • pp.156-162
    • /
    • 1992
  • In the measurement of proton gyromagnetic ratio by a low field cechnique, the compensation of earth's field is required to keep a zero-field space. The constant earth's fild is compensated by a cur-rent flowing through a Helmholtz coil, whereas small time-varying component is compensated automatically by a closed loop of feedback system. A feedback amplifier, and two three-dimensional Helmholtz coils having the same coil constant have been constructed in order to compensate the earth's field. field. Preliminary test performed at the ordinary laboratory showed that the time-vary-ing field of ${\pm}100nT$ and the constant field have been reduced to the level of ${\pm}10nT$ using the compensating system.

  • PDF

Transcranial Magnetic Stimulation with repetive charge-discharge ability flyback (플라이백방식의 충·방전 제어기법을 적용한 경두개 자기자극장치)

  • Kim, Whi Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.325-328
    • /
    • 2009
  • In this study, A Magnetic stimulation Pulse Train control technique is introduced and applied to Flyback converter operating in discontinuous conduction mode. In contrast to the conventional pulse width modulation control scheme, the principal idea of a Magnetic stimulation Pulse Train is to achieve output voltage regulation using high and low power pulses. The proposed technique is applicable to any converter operating in discontinuous conduction. However, this work mainly focuses on Flyback topology. In this paper, the main mathematical concept of the new control algorithm is introduced and simulations as well as experimental results are presented.

  • PDF

회전자계 역수신 코일을 이용한 관벽의 자기공명영상

  • 문치웅;조종운;백문영;조지연;박청수;신운재;이현용;은충기
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.176-176
    • /
    • 2001
  • 목적: 기존의 역수신코일(inside-out receiver coil)로 관벽의 MR 영상을 얻을 때 영상영역이 좁고 수신감도가 불균일한 단점을 보완하면서 신호대 잡음비(S/N ratio)도 높일 수 있는 회전자계역수 신코일(quadratic inside-out receiver coil)의 개발을 목적으로 한다. 대상 및 방법: 8극형코일, 선형자계수신코일, 회전자계수신코일에 대하여 컴퓨터 모의실험으로 영상영역 및 감도의 균일성을 비교하였다. 회전자계수신코일은 안장 모양을 한 두 개의 선형자계코일이 서로 간섭이 일어나지 않도록 수직 방향으로 배열된 구조를 갖도록 하였다. 지름 3 cm 크기로 각 코일을 제작하였으며 지름 20 cm의 원통 중앙에 내경 4 cm의 관이 있는 팬텀을 만들어 MnC1$_2$를 섞은 물을 채운 다음 1.5T 초전도 MRI 장치와 0.3T 영구자석 MRI 장치에서 팬텀의 관벽 영상을 얻었다. 본 실험을 시행한 1.5T 장치의 구조 때문에 회전자계코일의 두 안장코일을 결합하는 회로를 제작하여 사용하였고 0.3T에서는 장치에 내장된 결합회로를 사용하였다. 또한 포르말린 용액에 보관된 소의 대장 조직 단면 영상을 FOV 10-12 cm로 얻어 회전자 계안장코일의 성능을 평가하였다.

  • PDF

Transmission characteristics of nonlinear torsional vibration of a rotating system with magnet coupling (평판 자기결합 회전장치의 비선형 비틀림 진동 전달 특성)

  • 서상준;전오성;은희준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.593-600
    • /
    • 1986
  • In direct contact power transmission from primary driver to a secondary follower system, one of the important problems is the vibration transmission. In some applications the reduction of vibration level at the follower as low as possible is utmost important. The magnetically coupled power transmission system is often used for this purpose. In this paper, we report the results of a study on the nonlinear torsional vibration transmission characteristics of the rotating system with face-type magnet coupling. The equation of motion is solved analytically up to 3rd harmonics. The frictional force of the sliding bearing which is used to support the follower shaft is considered as the damping term. Numerical calculations are carried out by the Newton-Raphson method, and the calculated results are compared with the experiment for face-type magnet coupling. The experimental result shows that the reasonant frequency of the magnet coupling is very low and is in good agreement with the theoretical result when the average damping constant per unit area of the sliding bearing is 0.5kg*f*sec/cm$^{3}$.

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

MR Haptic Device for Integrated Control of Vehicle Comfort Systems (차량 편의장치 통합 조작을 위한 MR 햅틱 장치)

  • Han, Young-Min;Jang, Kuk-Cho
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.12
    • /
    • pp.291-298
    • /
    • 2017
  • In recent years, the increase of secondary controls within vehicles requires a mechanism to integrate various controls into a single device. This paper presents control performance of an integrated magnetorheological (MR) haptic device which can adjust various in-vehicle comfort instruments. As a first step, the MR fluid-based haptic device capable of both rotary and push motions within a single device is devised as an integrated multi-functional instrument control device. Under consideration of the torque and force model of the proposed device, a magnetic circuit is designed. The proposed MR haptic device is then manufactured and its field-dependent torque and force are experimentally evaluated. Furthermore, an inverse model compensator is synthesized under basis of the Bingham model of the MR fluid and torque/force model of the device. Subsequently, haptic force-feedback maps considering in-vehicle comfort functions are constructed and interacts with the compensator to achieve a desired force-feedback. Control performances such as reflection force are experimentally evaluated for two specific comfort functions.