• Title/Summary/Keyword: 자기부식

Search Result 105, Processing Time 0.024 seconds

Performance Change of Application Devices Caused by Magnetorheological Particle Corrosion (자기유변 입자 부식에 따른 응용장치의 성능 변화)

  • Han, Young-Min;Choi, Seong-Cheol
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.193-199
    • /
    • 2016
  • MR(magnetorheological) devices for vehicle applications requires the consistent control performance and the reliable operation. However, the corrosion of iron particles consisting the MR fluid can significantly affect on MR properties. This paper presents an effect of the MR particle corrosion on the performance of MR fluids such as shear stress magnitude which is directly concerned with control performance. As a first step, MR particles are corroded by water-calcium chloride solution. The resulting MR particles are examined by scanning electron microscope (SEM) and their molar ratios are analyzed by the energy dispersive X-ray analysis (EDAX). By dispersing the corroded MR particles into silicone oil, the corroded MR fluid is synthesized for evaluation of MR effect change. A rotational viscometer is adopted to measure shear stress magnitude. Finally, it is demonstrated how much the corrosion affect on performances by comparing the normal MR fluid to the corroded MR fluid, from which performance investigation of the MR devices containing the corroded MR particles will be studied in the second phase of this study.

Research of corrosion decision on a region weld in MFL system (자기 누설 탐상 시스템에서 용접부위에서의 부식 판정에 관한 연구)

  • Jeong, Hyun-Won;Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.978-980
    • /
    • 2005
  • 자기 누설 탐상(Magnetic Flux Leakage : MFL) 시스템은 비파괴 검사의 한 방법으로 검사 대상 물체를 적절히 포화시켜 부식이나 결함 부위에서의 누설 자속을 측정하여 결함의 유 무와 크기를 판단하는 방법이다. 대부분 가스관과 가스관을 연결하는 방법으로 용접을 가장 많이 사용하고 있으며 용접부위에서 부식이 가장 많이 발생하고 있다. 용접으로 인해 발생하는 자기 누설신호는 부식신호에 많은 영향을 미친다. 따라서 본 연구는 용접신호가 부식 신호에 미치는 영향을 분석하기 위해 가스관의 용접과 부식과의 거리에 따른 자기누설을 해석하고, 분석하였다. 또한 용접에 의해 왜곡된 부식신호를 보정하고, 판정을 위한 방법을 제시하였다.

  • PDF

Effects of the Multi-Defects on Detecting Signals in Magnetic Flux Leakage System (자기누설탐상시스템에서 밀집된 다수의 결함이 탐상 신호에 미치는 영향)

  • Seo, Kang;Jeong, Hyun-Won;Park, Gwan-Soo;Lee, Min-Ho;Choi, Doo-Hyun;Lee, Seung-Hyun;Um, Chang-Gun;Shin, Pan-Seok;Kim, Chul;Rho, Yong-Woo;Yoo, Hui-Ryong;Cho, Sung-Ho;Kim, Dong-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.70-73
    • /
    • 2005
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 가스관에는 한 개의 독립적인 부식도 있지만, 다수의 부식이 밀집되어 나타나기도 한다. 다수의 부식이 밀집되었을 경우 부식간의 거리에 따라 하나의 부식으로 판정되기도 하며, 그에 따라 부식의 깊이를 판정하는데 있어 정확성이 저감된다. 따라서 본 논문에서는 다수의 부식이 밀집되어 발생할 경우 자기적 영향을 분석하고, 깊이 판정에 있어 정확성을 높이기 위한 연구를 수행하였다. 이를 위해서 실제 결함을 제작하여 실험하고, 해석하여 비교하였으며 밀집된 다수의 부식에 의한 자기적 영향에 대하여 고찰하였다.

  • PDF

A Study on Corrosion CoCrMo Magnetic Thin Films (CoCrMo 자성박막의 부식에 관한 연구)

  • 남인탁;홍양기
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.3
    • /
    • pp.221-228
    • /
    • 1993
  • The general requirements of recording media include recording performance, environmental stability, runnability on the drive or deck, and manufacturability. CoCrMo thin films were prepared using RF sputtering system for a study on chemical stability. Surface degradation of the CoCrMo thin film was studied by SEM, XPS and AES. Surface degradation was found to be dependent of sputtering condition and Mo content. Addition of Mo to CoCr thin film improved dramatically its surface degradation resistance in dilute sulfuric acid, as indicated by active-passive transition appeared in electrochemical polarization curve. Futhermore, the passive current density was decreased with increasing Mo content. The reduction in a number density of corrosion sites by Mo addition vms observed, after accelerated corrosion test. AES survey indicated that corrosion occured on the site with Cr depletion and highly concentrated chloride ions.

  • PDF

Effect on detecting signal according to transition of pipeline thickness in Magnetic Flux Leakage system (자기누설탐상시스템에서 배관의 두께 변화가 탐상신호에 미치는 영향)

  • Seo, Kang;Park, Gwan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.643-644
    • /
    • 2006
  • 자기누설탐상시스템은 지하에 매설된 가스관에서 발생되는 부식이나 크랙 또는 기계적 변형을 탐지하기 위한 방법으로 비파괴검사 방법의 하나이다. 가스관은 Nd자석에 의해 착자가 되고, 가스관에 부식이 발생했을 경우 가스관의 단면적이 작아지게 되어 자기누설이 발생하며, 발생된 자기누설을 홀센서로 검출하여 부식의 유무, 크기, 모양 등을 판별하게 된다. 지하매설 배관은 배관의 직경은 같으나 배관의 두께는 다양하게 존재한다. 특히 30inch의 배관에는 배관의 두께가 11.1, 14.3, 17.5 mm 등이 있다. 자기누설탐상시스템은 배관의 단면적 변화를 감지하는 것이기 때문에 배관의 두께에 따라 그 특성이 변화하게 된다. 또한 두께에 따른 결함의 종류에 따라서 검출신호도 변화하게 된다. 따라서 본 논문에서는 배관의 두께 변화에 따른 검출신호를 분석하였으며, 두께 변화의 영향을 적용하여 검출신호를 보정하기 위한 방법을 제시하였다.

  • PDF

A Study on the Method for the Removal of Radioactive Corrosion Produce Using Permanent and Electric Magnets

  • Kong Tae-Young;Song Min-Chul;Lee Kun-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.2
    • /
    • pp.113-123
    • /
    • 2005
  • The removal of radioactive corrosion products from the reactor coolant through a magnetic filter system is one of the many approaches being investigated as a means to reduce radiation sources and exposures to the operational and maintenance personnel in a nuclear power plant. Many research activities in water chemistry, therefore, have been performed to provide a filtration system with high reliability and feasibility and are still in process. In this study, it was devised the magnetic filter system with permanent and electric magnets to remove the corrosion products in the coolant stream taking an advantage of the magnetic properties of corrosion particles. Permanent magnets were used for separation of corrosion products and electric magnets were utilized for flocculation of colloidal particles to increase in their size. Experiments using only permanent magnets, in the previous study, displayed the satisfactory outcome of filtering corrosion products and indicated that the removal efficiency was more than 90 $\%$ for above 5 $\mu$m particles. Experiments using electric magnets also showed the good performance of flocculation without chemical agents and exhibited that most corrosion particles were flocculated into larger aggregates about 5 $\mu$m and over in diameter. It is, thus, expected that the magnetic filter system with the arrangement of permanent and electric magnets will be an effective way for the removal of radioactive corrosion products with considerably high removal efficiency.

  • PDF

The Effect of Annealing on Corrosion Behavior of CoCrTa/CrNi Magnetic Recording Media (CoCrTa/CrNi 자기기록매체의 열처리에 따른 부식거동 변화)

  • 우준형;남인탁
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.4
    • /
    • pp.210-216
    • /
    • 1999
  • The objective of this paper is to investigate corrosion behaviors of CoCrTa/CrNi thin film and post heat-treatment effect. An electron beam evaporator was used for films deposition. After evaporation, post heat-treatment was carried out under $5.0{\times}10^3$ Torr vacuum condition. Annealing temperature and time were 400 $^{\circ}C$ and 30 min, respectively. To understand the effect of annealing on corrosion behavior of CoCrTa/CrNi, potentiodynamic polarization technique and accelerated corrosion chamber test were undertaken. Corrosion potential is higher for the annealed samples (CoCrTa 400$\AA$/CrNi 1000$\AA$) than for as-deposited one. This is attributed to an enrichment of Cr in the surface layer of the thinfilm resulting in a more corrosion resistant material.

  • PDF

Anticorrosive Coating Material with Dual Self-healing Capability for Steel Coating (이중 자기치유 메커니즘을 통한 강판의 내부식성 코팅)

  • Lee, Hyang Moo;Yun, Sumin;Kim, Jin Chul;Cho, Soo Hyoun;Cheong, In Woo
    • Journal of Adhesion and Interface
    • /
    • v.22 no.2
    • /
    • pp.47-56
    • /
    • 2021
  • Steel plates coated by self-healable polymer still can be rusted since it takes time to be healed. In this study, dual self-healing coating material is developed using corrosion inhibitor (DTBEDA) which can form hindered urea (HUB) as reversible cross-linking bond at the same time. Developed dual self-healing polymer is coated on steel plate, and scratch healing property was investigated by surgical blades and nano/micro indentation tester. The anticorrosion effect of DTBEDA was investigated by electrochemical impedance spectroscopy (EIS).

강자성 배관의 racetrack 형 결함깊이와 응력이 누설자속에 미치는 영향

  • ;;;D.L. Atherton;L. Clapham
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2002.12a
    • /
    • pp.118-119
    • /
    • 2002
  • 실시간으로 매설된 송유관이나 가스관의 내부에 누설자속 (Magnetic Flux Leakage: MFL) 탐지용 피그를 통과시킴으로서 부식을 모니터한다[1]. NdFeB 자석과 같은 강한 영구자석으로 배관을 자화시키면 부식에 의한 결함 근처에서 자속이 누설되고, 그 MFL은 Hall 프로브나 유도코일에 의해 탐지된다. 자기이방성을 이용하여 응력에 의만 누설자속신호 변화를 계산할 수 있다. MFL 신호를 정밀하게 분석하기 위해서는 측정프로브의 측정속도와 내부압력응력과 같은 운용조건을 고려하여야 한다[2]. (중략)

  • PDF

A Method For Autonomous Determination Of Corrosion State Of Gas-pipeline Using RPM-based SOM (관계적시점지도로 구성된 SOM을 이용한 가스배관 부식상태의 자율적 판단 방법)

  • Sohn, Choong-Yeon;Yeo, Ji-Hye;Ko, Il-Ju
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.01a
    • /
    • pp.137-140
    • /
    • 2011
  • 시설의 안전성 평가에 대한 연구는 안전성에 영향을 주는 데이터를 정량화하여 획일적인 자동 수행하는 안전관리가 주를 이루고 있다. 이와 달리 자율수행은 수집 된 상황 정보나 상태 데이터를 이용하여 안전성을 예측하고 사고 위험성을 경보하여 사고를 예방 할 수 있다. 본 연구에서는 다양한 시설물 중에서 가스배관의 부식에 대한 판단을 위해서 신경망의 대표적 비지도학습인 자기조직화지도를 적용한다. SOM의 적용에서는 주변효과를 보완하기 위해서 관계적관점지도로 맵을 구성한다. 학습 할 데이터는 가스배관의 방식전위이다. 배관의 부식상태를 확인하기 위하여 수집 된 데이터인 방식전위에는 부식에 대한 위험요인이 내재되어 있다. 학습 후 새로운 데이터가 입력되면 각 상태 군집의 중심뉴런과 맵핑된 뉴런의 유사도를 측정하여 배관의 부식상태를 결정한다. 제안 된 방법으로 판단 된 결과를 기존에 사람이 판단한 결과와 비교하여 검증한다. 이를 통해 배관의 부식상태를 자율적이고 신속하게 판단하여 지능화 된 가스배관 관리로 활용한다.

  • PDF