• Title/Summary/Keyword: 자기공명주파수분석법

Search Result 9, Processing Time 0.028 seconds

A study of $Smartpeg^{TM}'s$ lifetime according to sterilization for implant stability (임플랜트 안정성을 위한 자기공명막대의 소독방법에 따른 수명에 관한 연구)

  • Won, Ho-Yeon;Cho, In-Ho;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.42-52
    • /
    • 2008
  • Purpose: Resonance Frequency Analysis(RFA) technique can be used as an effective method in measuring the implant stability and documenting the clinical results. This technique also determines how stable the implant is before performing a prosthetic practice. Having become one the guidelines of the implant therapy whose final objective is the immediate loading, the $Osstell^{TM}$ mentor is giving a lot of information to the clinicians recently. In this communication, experiments were performed to investigate how reliable the measured ISQ values by $Osstell^{TM}$ mentor are, and to see if those are also stable even after sterilization. As five objectives: 1) How stable measured ISQ values after fixation $Smartpeg^{TM}s$ for 400 times. 2) How stable measured ISQ values after 'attach-detach'$Smartpeg^{TM}'s$ for 400 times. 3) How stable measured ISQ values after clinical sterilization methods. 4) How stable measured ISQ values after repeatedly sterilization in autoclave for 10 times. 5) What is the critical temperature which is lost the magnetism of $Smartpeg^{TM}$. Materials and Methods: Clinical sterilization methods(Autoclave sterilization, Dentistar sterilization, Ultra violet sterilization, Vacuum dry unit sterilization, Boiling water sterilization, combined $H_{2}O_{2}$ and Alcohol sterilization).$Smartpeg^{TM}s$. D3 Block bone($3{\times}9{\times}2cm$). Osstem implant(${\emptyset}4.1$-10mm).$Osstell^{TM}$ mentor. Individual experiment was used 8 number of $Smartpeg^{TM}s$ and they had measured to ISQ values of before experiment and after experiment. Results: 1. The measured ISQ values did not change after fixation $Smartpeg^{TM}s$ for 400 times. 2. There was no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ for 400 times. 3. The measured ISQ values did not change after the usual clinical sterilization methods. 4. The measured ISQ values did not change after sterilization in autoclave for 10 times. 5. It was impossible to exactly measure the critical temperature which is lost the magnetism of $Smartpeg^{TM}s$. But, the results was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10 minute. Conclusion: The measured ISQ values showed insignificant differences in case of no changes in the magnetism of the $Smartpeg^{TM}s$. It seems that the $Smartpeg^{TM}s$ can be used repeatedly in every measurement if the original magnetisms of the $Smartpeg^{TM}s$ can be recognized. There seems to be no significant changes in the measured ISQ values of 'attach-detach $Smartpeg^{TM}s'$ only if the screw pitches were unimpaired. The clinical sterilization methods seems acceptable because the result was resulted to lost its magnetism in higher temperature than $150^{\circ}C$/10minute.

A Comparison of MRS Data for SVS and 3D CSI in Human Brain Study (두경부 MRS검사의 SVS와 3D CSI 데이터의 비교 분석및 임상응용을 위한 연구)

  • Yoon, Seong-Ik;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2005.04a
    • /
    • pp.93-95
    • /
    • 2005
  • MRS is to measure very small metabolite signals, whose resonant frequencies spread over the chemical shift range characteristic of the measured nucleus. The MR signal originates from the excited volume, which is a column of tissue divided into slices by gradient or rf encoding. The parameters that acquired data affected by TE, TR, and other variables. The higher spatial resolution of 3D CSI compared to SVS and its ability to examine regional metabolite variations for brain study.

  • PDF

Analysis of Eddy Current Effect in Magnetic Resonance Imaging Using the Finite Element Method (유한요소법에 의한 자기공명영상시스템에서의 와전류 영향 분석)

  • Lee, Jeong-Han;Gang, Hyeon-Su;Jo, Min-Hyeong;Mun, Chi-Ung;Lee, Gang-Seok;Lee, Su-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1999
  • Eddy current in MRI systems degrades gradient field linearity and distorts gradient waveform. When the waveform distortion is spatially variant, it is very difficult to perform special imaging techniques such as the echo planar imaging technique or the fast spin echo imaging technique. In this study, we have developed a new technique to estimate the distorted gradient waveforms at any points inside the imaging region using the finite element method. After obtaining the eddy-current-effect transfer function, which represents magnitude and phase characteristics of the gradient field at a particular point, we have used the transfer function to estimate the actual gradient waveforms at the point. To verify the proposed technique, we have compared the estimated gradient waveforms with the measured ones.

  • PDF

Nonlinearity in the Somatosensory Cortex Response to Vibrotactile Stimulator in fMRI (기능성 자기공명영상에서 진동자극에 대한 감각피질의 비선형성)

  • Lee, Hyun-Sook
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.159-166
    • /
    • 2006
  • The nonlinearity of hemodynamic response in the somatosensory cortex was investigated with vibrotactile stimulation. The stimuli consisted of a train of 25 Hz, each tasting five different duration periods, 2 s, 4 s, 8 s 12 s, or 16 s with 20 sec periods of no vibration in a pseudo-random order. In order to understand the linearity on the change of stimulus duration for somatosensory cortex, two different tests- checking the linearity of system and finding the impulse response function from gamma-variate function were applied to analyze the hemodynamic response functions. They have produced nearly same results. The BOLD response in the somatosensory cortex Is nonlinear for stimuli of less than 8 seconds, but nearly linear for stimuli greater than 8 seconds. The amplitude, area, TTP, and FWHM as functions of the stimulus duration were calculated and showed a significant downward trend with Increasing stimulus duration for the amplitude and the area. It supports the ranges of nonlinearity are less than 8 seconds.

  • PDF

A Study on the Photo-Degradation Properties of the Spiropyran Using THz-TDS (테라헤르츠 시간 영역 분광법을 이용한 스피로파이란의 광 퇴화 특성 연구)

  • Bang, Jin-Hyuk;Park, Myoung-Hwan;Ryu, Han-Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.60 no.1
    • /
    • pp.28-33
    • /
    • 2016
  • The spiropyran is a typical material having photodegradation properties in the process of photochromism. The spiropyran has been utilized in various applications such as optical switch, optical memories, and biosensor because of its remarkable stability, fast responsive time, stronger color change, and photo-induced controllability. However, the spriropyran is photodegraded by the repetitive optical irradiation. The photodegradation of spiropyran have been investigated by using UV-Visible spectroscopy, nuclear magnetic resonance (NMR), and Raman spectroscopy. Herein, the properties of spiropyran were characterized by using terahertz time-domain spectroscopy (THz-TDS) in the terahertz frequency region. In terahertz region, the measured absorbance of spiropyran was increased due to the photodegradation induced by the repetitive UV irradiation. The absorbance tendency of spiropyran in the terahertz frequency region was compared with that in the visible region, and they were completely opposite to each other.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

MR Study of Wate Exchange and Cell Membrane Permeability in Rat Liver Cells Using a Tissue-Specific MR Contrast Agent (조직 특성 MR 조영제를 이용한 쥐의 간세포막의 물분자 교환 및 투과율의 MR 측정기법)

  • Yongmin Chang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.73-82
    • /
    • 1998
  • Purpose : A precise NMR technique for measuring the rate of water exchange and cell membrane permeability across the hepatocyte membrane using liver-specific MR contrast agent is described. Materials and Methods : The rat hepatocytes isolated by perfusion of the livers were used for the NMR measurements. All experiments were performed on an IBM field cycling relaxometer operating from 0.02MHz to 60 MHz proton Larmor frequency. spin-echo pulse sequence was empolyed to measure spin-lattice relaxation time, T1. The continuous distribution analysis of water proton T1 data from rat hepatocytes containing low concentrations of the liver specific contrast agent, Gd-EOB-DTPA, modeled by a general two compartment exchange model. Results : The mean residence time of water molecule inside the hepatocyte was approximately 250 msec. The lower limit for the permeability of the hepatocyte membrane was $(1.3{\pm}0.1){\;}{\times}{\;}10^{-3}cm/sec$. The CONTIN analysis, which seeks the natural distribution of relaxation times, reveals direct evidence of the effect of diffusive exchange. the diffusive water exchange is not small in the intracellular space in the case of hepatocytes. Conclusions : Gd-EOB-DTPA, when combined with continuous distribution analysis, provides a robust method to study water exchange and membrane permeability in hepatocytes. Water exchange in hepatocyte is much slower thatn that in red blood cells. Therefore, tissue-specific contrast agent may be used as a functional agent to give physiological information such as cell membrane permeability.

  • PDF

A 3 year prospective study of survival rate of narrow diameter implants (좁은 직경 임플란트 3년간의 생존율에 관한 후향적 연구)

  • Lee, Sung-Jo;Jung, Sae-Young;Shin, Hyun-Seung;Park, Jung-Chul;Song, Young-Gyun;Cho, In-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.32-38
    • /
    • 2018
  • Purpose: The purpose of present study was to retrospectively analyze the survival rate of narrow diameter implant less than 3.6 mm by initial stability and radiographic measurements. Materials and Methods: In total, 24 patients who received 38 narrow diameter implants (${\leq}3.6mm$ in diameter, ${\geq}7mm$ in length) were enrolled in this retrospective study. The cumulative survival rate was calculated and various factors were investigated according to the implant platform diameter, body diameter, length, position, concomitant use of guided bone regeneration in implant placement and final prosthesis type. Initial stability was investigated with implant stability quotient (ISQ) value. The mesial and distal marginal bone level (MBL) change was calculated with radiography. Results: The overall survival rate was 92.11%. Mean ISQ value and MBL change of survival implants was 66.26 and $0.14{\pm}0.31mm$, respectively. None of the implants with platform diameters larger than the body diameter failed. Conclusion: In conclusion, the findings of present study suggest that narrow diameter implant could be predictable treatment in narrow alveolar ridge.

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF