• Title/Summary/Keyword: 자기공명의료영상

Search Result 92, Processing Time 0.023 seconds

Effective Object Recognition based on Physical Theory in Medical Image Processing (의료 영상처리에서의 물리적 이론을 활용한 객체 유효 인식 방법)

  • Eun, Sung-Jong;WhangBo, Taeg-Keun
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.12
    • /
    • pp.63-70
    • /
    • 2012
  • In medical image processing field, object recognition is usually processed based on region segmentation algorithm. Region segmentation in the computing field is carried out by computerized processing of various input information such as brightness, shape, and pattern analysis. If the information mentioned does not make sense, however, many limitations could occur with region segmentation during computer processing. Therefore, this paper suggests effective region segmentation method based on R2-map information within the magnetic resonance (MR) theory. In this study, the experiment had been conducted using images including the liver region and by setting up feature points of R2-map as seed points for 2D region growing and final boundary correction to enable region segmentation even when the border line was not clear. As a result, an average area difference of 7.5%, which was higher than the accuracy of conventional exist region segmentation algorithm, was obtained.

3D Visualization of Medical Image Registration using VTK (VTK를 이용한 의료영상정합의 3차원 시각화)

  • Lee, Myung-Eun;Kim, Soo-Hyung;Lim, Jun-Sik
    • The KIPS Transactions:PartB
    • /
    • v.15B no.6
    • /
    • pp.553-560
    • /
    • 2008
  • The amount of image data used in medical institution is increasing rapidly with great development of medical technology. Therefore, an automation method that use image processing description, rather than manual macrography of doctors, is required for the analysis large medical data. Specially, medical image registration, which is the process of finding the spatial transform that maps points from one image to the corresponding points in another image, and 3D analysis and visualization skills for a series of 2D images are essential technologies. However, a high establishment cost raise a budget problem, and hence small scaled hospitals hesitate importing these medical visualizing system. In this paper, we propose a visualization system which allows user to manage datasets and manipulates medical images registration using an open source graphics tool - VTK(Visualization Tool Kit). The propose of our research is to get more accurate 3D diagnosis system in less expensive price, compared to existing systems.

Imaging Features and Pathological Correlation in Mixed Microcystic and Angiomatous Meningioma: A Case Report (미세낭종성 혈관종성 혼합 수막종의 영상 및 병리 소견: 증례 보고)

  • Keonwoo Choi;Dae Yoon Kim;Hyun Jin Kim;Gyojun Hwang;Mi Kyung Kim;Hyun Gon Kim;Soya Paik
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.4
    • /
    • pp.951-957
    • /
    • 2022
  • Meningiomas are the most common intracranial tumors. However, microcystic and angiomatous meningiomas are very rare subtypes that present unusual imaging findings. Hence, radiological diagnosis of these tumors can be challenging. We herein describe a case of mixed angiomatous and microcystic meningioma in an 81-year-old male. MRI revealed an extra-axial mass with high T2 signal intensity, measuring 1.5 cm in diameter, with multiple tiny intralesional cysts and entrapped peritumoral cyst formation. After tumor resection, a histopathological diagnosis of mixed angiomatous and microcystic meningioma was made.

Understanding of Perfusion MR Imaging (관류자기공명영상의 이해)

  • Goo, Eun-Hoe
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.27-31
    • /
    • 2013
  • Perfusion MR imaging is how to use exogenous and endogenous contrast agent. Exogenous perfusion MRI methods which are dynamic susceptibility contrast using $T2^*$ effect and dynamic contrast-enhanced using T1 weighted image after injection contrast media. An endogenous perfusion MRI method which is arterial spin labeling using arterial blood flow in body. In order to exam perfusion MRI in human, technical access are very important according to disease conditions. For instance, dynamic susceptibility contrast is used in patients with acute stroke because of short exam time, while dynamic susceptibility contrast or dynamic contrast enhancement provides the various perfusion information for patients with tumor, vascular stenosis. Arterial spin labeling is useful for children, women who are expected to be pregnant. In this regard, perfusion MR imaging is required to understanding, and the author would like to share information with clinical users

  • PDF

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

Bone Segmentation Method based on Multi-Resolution using Iterative Segmentation and Registration (영역화와 정합 기법을 반복적으로 이용한 다중 해상도 기반의 뼈 영역화 기법)

  • Park, Sang Hyun;Lee, Soochahn;Yun, Il Dong;Lee, Sang Uk
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2011.07a
    • /
    • pp.439-440
    • /
    • 2011
  • 최근 의료 장비들이 발전하고 진단 및 연구에 다양하게 이용되면서 이로부터 얻은 3차원 의료 영상들을 자동으로 처리해주는 기술의 수요가 늘고 있다. 자동 뼈 영역화 기법은 이러한 기술들 중 하나로써 골다공증이나 뼈 골절, 골격질환 등의 진단의 효율성을 크게 높여줄 것으로 기대되고 있다. 그러나 현재까지 이를 위한 다양한 연구들이 진행되었음에도 2차원 영상과는 달리 높은 데이터양과 주변 조직과의 모호한 경계들이 많다는 어려움 때문에 실제 진단에는 사용되지 못하고 있다. 이에 따라 본 논문에서는 다중 해상도를 기반으로 하여 영역화와 정합기법을 반복적으로 수행함으로써 3차원 의료 영상 내에서 자동으로 뼈를 영역화 해내는 기법을 제안한다. 낮은 해상도 단계에서 학습된 집합의 뼈 정보들을 이용하여 대략적인 뼈 위치를 검출하고, 이후 해상도를 높여가면서 정합 과정과 영역화 과정을 반복적으로 수행한다. 성능을 확인하기 위해 무릎 자기공명영상(magnetic resonance image)내에서 대퇴골(femur)과 경골(tibia)을 영역화 하는 실험을 진행하였으며 60개의 학습 데이터들을 바탕으로 40개 영상에서의 뼈들을 영역화 하였다.

  • PDF

Multimodality Image Registration by Optimization of Mutual Information (상호정보 최적화를 통한 다중 모달리티 영상정합)

  • 홍헬렌;김명희
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2000.11a
    • /
    • pp.180-185
    • /
    • 2000
  • 방사선 치료계획이나 사전수술계획 등에 컴퓨터 사용이 늘어남에 따라 의료영상별 특성에 따른 복합적 처리를 필요로 한다. 본 논문에서는 다중 모달리티 영상으로부터 의미 있는 정보를 제공하기 위하여 상호정보 최적화를 통한 영상정합 방법을 제안한다. 본 방법은 두 영상에서 대응되는 위치의 명암도간 통계적 의존관계와 정보중복성을 계산하는 상호정보(mutual information)를 통해 영상간 변형관계를 추정함으로써 영상을 정합한다. 실험결과로는 뇌 자기공명영상(MRI)과 컴퓨터단층촬영영상(CT)의 상호정보를 최적화하여 정합 결과를 제시한다. 본 방법은 기존 정합방법에서 사용하는 영상분할이나 특징점 추출 등의 전처리 과정 없이 영상 자체 정보를 기반으로 계산함으로써 정합의 정확도를 높일 수 있다.

  • PDF

특수의료장비의 설치 및 운영에 관한 규칙에 의한 정도관리 시행

  • 정해조;김희중;김기황
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.51-51
    • /
    • 2003
  • 국민건강보험재정건전화특별법 (제정 2002.1.19 법률 제 6620호)은 건강보험의 재정적자를 조기에 해소하고 재정수지의 균형을 이루도록 함으로써 건강보험제도의 발전과 국민건강 증진 도모를 그 목적으로 하며, 제14조(특수의료장비의 설치ㆍ운영)에서 의료기관은 보건복지부장관이 고시한 특수의료장비를 설치ㆍ운영하고자 하는 때에는 보건복지부령이 정하는 바에 따라 이를 등록하여야 하며 설치 인정 기준에 적합하게 설치ㆍ운영하여야 하고 정기적인 품질관리를 받아야한다고 명시하였다. 특수 의료장비의 설치 및 운영에 관한 규칙 (제정 2003.1.14 보건복지부령 제235호)은 국민건강보험재정건전화특별법이 제정됨에 따라 특수의료장비의 적정 한 설치와 활용을 위하여 의료기관에서 설치ㆍ운영하는 특수의료장비의 등록절차 설치인정기준 및 품질관리 절차 등을 정하고 특수의료장비에 대한 관리체계를 확립하려는 것이다. 특수의료장비의 설치 및 운영에 관한 규칙의 주요 골자는 가. 의료기관에서 특수장비를 설치ㆍ운영하고자 하는 경우 보건복지부장관 또는 시ㆍ도 지사에게 등록하도록 하였는바, 이 등록에 대한 절차와 특수의료장비의 설치인정기준을 정함, 나. 특수의료 장비에 대한 정기적인 품질관리검사를 서류검사와 정밀감사로 구분하여 서류검사는 1 년마다, 정밀검사는 3 년마다 받도록 함, 다. 품질관리검사기관의 장은 특수의료장비품질관리검사성적서를 신청인에게 교부하고, 보건복지부 또는 시ㆍ도지사 및 건강보험심사평가위원장에게 검사결과를 통보하도록 함, 라. 특수의료정비를 설치ㆍ운영하는 의료기관의 개설자 또는 관리자 및 품질관리검사기관의 장이 작성ㆍ비치ㆍ보존하여야할 서류를 정함이다. 보건복지부장관에게 등록하여야할 특수의료장비는 자기공명영상촬영장치와 전산화단층촬영 장치이며, 시ㆍ도지사에게 등록하여야할 특수의료장비는 유방촬영용장치이다. 본 발표에서는 특수의료장비의 설치 및 운영에 관한 규칙에 대한 개요와 연세의료원 세브란스병원에서 시행하고 있는 특수의료장비의 정도관리 검사, 팬텀영상검사, 그리고 임상영상검사를 소개하고자한다.

  • PDF

The Feasibility for Whole-Night Sleep Brain Network Research Using Synchronous EEG-fMRI (수면 뇌파-기능자기공명영상 동기화 측정과 신호처리 기법을 통한 수면 단계별 뇌연결망 연구)

  • Kim, Joong Il;Park, Bumhee;Youn, Tak;Park, Hae-Jeong
    • Sleep Medicine and Psychophysiology
    • /
    • v.25 no.2
    • /
    • pp.82-91
    • /
    • 2018
  • Objectives: Synchronous electroencephalogram (EEG) and functional magnetic resonance imaging (fMRI) has been used to explore sleep stage dependent functional brain networks. Despite a growing number of sleep studies using EEG-fMRI, few studies have conducted network analysis on whole night sleep due to difficulty in data acquisition, artifacts, and sleep management within the MRI scanner. Methods: In order to perform network analysis for whole night sleep, we proposed experimental procedures and data processing techniques for EEG-fMRI. We acquired 6-7 hours of EEG-fMRI data per participant and conducted signal processing to reduce artifacts in both EEG and fMRI. We then generated a functional brain atlas with 68 brain regions using independent component analysis of sleep fMRI data. Using this functional atlas, we constructed sleep level dependent functional brain networks. Results: When we evaluated functional connectivity distribution, sleep showed significantly reduced functional connectivity for the whole brain compared to that during wakefulness. REM sleep showed statistically different connectivity patterns compared to non-REM sleep in sleep-related subcortical brain circuits. Conclusion: This study suggests the feasibility of exploring functional brain networks using sleep EEG-fMRI for whole night sleep via appropriate experimental procedures and signal processing techniques for fMRI and EEG.

A Study on the Parallel Processing Architecture for the Real Time Image Reconstruction of X-ray CT (X-ray CT의 실시간 영상재구성을 위한 병렬처리 구조에 관한 연구)

  • Jin, Seung-Oh;Heo, Chang-Won;Huh, Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3153-3155
    • /
    • 1999
  • 최근 수년간 의료영상분야는 국내외적으로 급격한 발전을 거듭하고 있다. 특히 자기공명영상장치 (Magnetic Resonance Imaging), X-ray CT(Computed Tomography)와 단층촬영장치는 인체내부를 비침습적(non-invasive)으로 영상화함으로써 해부학적인 질병진단에 많은 장점을 가지고 있다. 이와같은 단층영상 재구성에는 역매트릭스법(matrix inversion). 반복재구성법(interative method), 역투영 법(back-projection), 2차원 Fourier 변환법(2D FFT), 중첩재구성법(Filtered back-projection) 등의 다양한 알고리즘을 사용하고 있다. 본 연구에서는 X-ray CT에서의 단층영상재구성 기법 중 널리 사용되고 있는 Filtered Back Projection 기법의 연산순서도와 연산량을 분석하고 이를 시뮬레이션을 통하여 확인하고 실시간 영상재구성을 위하여 범용 Digital Signal Processor의 병렬처리시스템 구성에 기반된 최적 Architecture를 선정하고자 한다.

  • PDF