Stress Analysis and Life Evaluation of Rotor and Retaining Ring of Generator for fossil power plant (화력용 발전기 회전자 및 리테인 링의 응력해석 및 수명평가)

  • Lee, Ji-Moon
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.148-153
    • /
    • 2004
  • This paper represents that parts of a large generator operating in 1000 MW are affected by centrifugal forces due to high-speed rotation in 3600 rpm and 3D FEM Analyses are required to obtained the structural reliability of the generator. From these results, one would know the weakest locations and the stress distributions. The fatigue life is calculated in order to grasp the remaining life of generator. 2D and 3D analyses are performed to calculate stresses of the generator rotor and the retaining ring. From 2D results, we find the SCF at the slot and sub-slot of the rotor. 3D analysis is applied at the end part of generator rotor, which represents complex geometry, and rotor and retaining ring shrink thermally. With these results, designers of rotor and retaining ring can compare with the results of design code and verify the stress distributions of generator rotor and retaining ring, and then calculate the remaining life from the low-cycle fatigue data.

  • PDF

Pre-processor programing for the vibrational characteristic of generator's stator (발전기 고정자의 진동특성을 위한 전처리기 프로그래밍)

  • Ahn, Chang-Gi;Bae, Yong-Chae;Ham, ji-woong;Lee, Dong-Woen
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.476-481
    • /
    • 2012
  • A plant's generator system under operating condition has been suffered the vibration from the excitation force with 120Hz. The vibration is generated in the stator end windings. For analyze dynamic characteristics of the generator's stator, its finite element model were obtained using ANSYS software package for modal and harmonic analysis. we compare the analysis result with experimental data. The results show that the resonance frequency, which is related with second ecliptical mode on the stator end windings 129Hz. The experimental results are good agreement with the FEA model.

  • PDF

A analysis of cooling system for generator according to ventilation path (유로 형상에 따른 선박용 발전기의 냉각 통풍 해석)

  • Lee, D.J.;Lim, Nam-Hyuk;Seol, S.S.;Kim, J.O.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1250-1254
    • /
    • 2004
  • To develop more compact and light generators which have high capacity, the most important thing that should be considered is the inner cooling system. Under all circumstances, the temperature of rotor and stator windings must be kept below the maximum temperature of insulation to maintain reliability and prolong durability of the machine. Therefore, the development of more effective cooling system and the exact prediction of windings are essential to produce our unique generator model which is reliable and competitive in international market. In this study, the flow of cooling air and the temperature distribution of winding is analyzed by using computational fluid dynamics. This analysis can lead to optimize the structure of cooling system and predict a local temperature rise.

  • PDF

An Experimental Study of Water Absorption Characteristics for Generator Stator Winding Insulation (발전기 고정자 권선 절연재 흡습 특성에 관한 실험적 연구)

  • Bae, Y.C.;Lee, D.S.;Kim, H.S.;Kim, Y.H.;Lee, H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.426-431
    • /
    • 2004
  • Leaking water coolant into stator electrical insulation is a growing concern for the aging water-cooled generator since leaks in the generator water-cooled stator winding can affect machine availability and insulation life. But a domestic techniques of such field are insufficient and depend wholly on GE or TOSHIBA technique. Therefore this paper introduces measuring principle and developed measuring system, which has been used to detecting wet absorption. We accomplished the experiment with a stator promotion of virtue which is used in actual power plant. Also, Experimental method of generator stator winding, which is investigated into wet absorption test.

  • PDF

A Study on the Systematic Mechanical Integrity Evaluation Methods of Water-Cooled Generator Stator Windings (수냉각 발전기 고정자의 기계적 건전성 평가방법)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Wook-Ryun;Lee, Doo-Young;Choi, Hong-Il;Yeon, Se-Heum
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3059-3066
    • /
    • 2008
  • It is reported that the life of generator stator windings is expected about 30 years and a leak and water absorption phenomena can be progressed by fatigue, vibration, and corrosion. The water-cooled generator stator windings which were operated over 15 years are over 20 units and the mechanical problems such as leak and water absorption were found in the generator stator windings. In this paper, the systematic mechanical integrity evaluation methods which are applied to the water-cooled generator stator windings within the country are introduced.

  • PDF

A Thermal Analysis of 1 kW Hydrogen Linear Generator (1kW급 수소리니어 발전기 열해석)

  • Yang, Si-Won;Lee, Jae-Sung;Kweon, Ki-Yeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.29-32
    • /
    • 2006
  • Recently, many researches of the alternative and renewable energy have introduced due to the increasing oil price, the limited natural resources and the environmental pollution. In case of hydrogen energy, it has some merits, which can be substituted the existing the fossil fuel because of no contaminants from the combustion and the chemical reaction. We have been developing 1kW Hydrogen Linear Generator. In this paper, the thermal characteristic of this prototype linear generator has been investigated and obtained reliable analysis results comparing with experimental measurements. Especially, it is predicted that in case of 1kW, 60Hz test sample, the results satisfy with the temperature standards of H type insulation, which is shown average $69.0^{\circ}C$ temperature distribution at the coil.

  • PDF

Study on Air-Gap Magnetic Flux Characteristics of Small-Scale 2-Pole Synchronous Generator (소용량 2극 동기발전기의 공극자속 특성 연구)

  • Bae, Duck-Kweon;im, Dong-HunK;Song, Myung-Gon;Lee, Dong-Young;Park, Jung-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.667-668
    • /
    • 2008
  • 현대 산업사회의 특징은 대용량화와 고속화에 있다. 전력부분에 있어서도 예외는 아니어서 초고층빌딩, 대단지 아파트, 공장, 위락시설, 병원 등 대용량 전력부하가 급격한 속도로 증가하고 있다. 특히 전력부분에 있어서는 대용량화와 동시에 경량 및 부피감소의 요구가 증대되면서도 신뢰성 높은 전력 품질 또한 요구되고 있다. 전기안전의 측면에 있어서 발전소의 안전불량은 전력수용가의 수급 차질로 인한 데이터 전산망, 생산설비의 막대한 재산 피해 뿐 아니라 병원 등에서의 인명피해도 발생시킬 수 있으므로 이에 대한 대책이 꼭 강구되어야 한다. 본 논문은 소용량 2극 동기발전기의 공극자속 파형 특성연구를 통하여 발전기 회전자 권선의 단락고장진단을 위한 예측진단기술을 개발하는 과정의 일환으로 진행되었으며 우선 정상상태의 공극자속을 컴퓨터 시뮬레이션 방법으로 계산하고 이를 시험치와 비교하여 해석 결과의 신뢰성을 평가하였다. 본 연구의 결과를 바탕으로 발전기의 모의 고장으로 발생하는 공극 자속의 특성을 연구하여 발전설비의 안전 확대에 기여할 것이다.

  • PDF

Vibration Powered Generator System for Stand-Alone Health Monitoring Sensor Unit (건전도 감시용 자립형 계측유닛을 위한 진동발전시스템)

  • 최남섭;김재민
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.85-92
    • /
    • 2003
  • This paper presents an electric power generating system for stand-alone health monitoring sensor unit of bridge structure based on ambient vibration of bridge. In this paper, a novel electric power generator which has minimum effect of armature reaction is proposed. The related mechanical and electrical design equations are obtained, and a pilot generator has been implemented. In addition, the charging system for extremely low generator current is discussed, and some improvements are identified for the system. This investigation reveals that diode characteristics of rectifier is dominant factor in the charging process. Finally, both the simulation, which uses real measurement data of the Namhae bridge as input of the pilot generator, and indoor test are carried out. The results showed the applicability and effectiveness of the stand-alone vibration powered generator.

PSCAD/EMTDC Simulation Model of Variable Speed Wind Power Generation System Using Permanent Magnet Synchronous Machine (영구자석형 동기기에 의한 가변속 풍력발전 시스템의 PSCAD/EMTDC 시뮬레이션 모델 개발)

  • Kim Jeong-Jae;Song Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.610-617
    • /
    • 2005
  • A variable speed wind turbine simulation model for grid connection is developed based on PSCAD/EMTDC. The model consists of wind model, rotor dynamics, synchronous generator, power converter, transformer, distribution line and infinite bus. Implementation of blade characteristics and power converter control strategies are included. Several transient case studies are performed including wind speed change, local load change and grid-side voltage unbalance using developed simulation model. The results of this work can be utilized for study of actual interaction between wind turbine and grid for reliable operation and protection of power system.

A Design of a Drone for Cleaning Polluted Areas on the Surface of Solar Panels using a 3-D SLAM Technique (SLAM 기술을 활용한 태양광 발전기 패널 표면의 오염영역 청소 드론 설계)

  • Jang, Woo-Hee;Kim, Ye-Eun;Kim, Hee-Jeong;Lee, Eun-Jin;Geun, Yoon Taek;Lee, Hong-Chang;Lee, Kwangjae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.1056-1059
    • /
    • 2019
  • 본 논문은 SLAM 기술로 3D 매핑하고 태양광 발전기 패널 표면의 오염영역을 파악하여 청소하는 자율비행 드론에 대한 연구이다. 본 프로젝트에서 구현된 드론은 SLAM 기술을 활용하여 3D 매핑과 ROS Topic 통신으로 자율비행을 하면서 카메라로 촬영한 영상에서 태양광 발전기 패널을 파악하고 패널에 있는 얇은 먼지막을 프로펠러에 의하여 발생하는 바람으로 제거한다. 그리고 열화상 카메라로 확인된 고오염 또는 고장으로 인한 발열 부분에 페인트 볼을 떨어트려 시각적으로 표시하고 관리자에게 능동적으로 알린다. 이로 인해 제안된 방법에 따라 넓은 영역에 분포된 다수의 태양광 발전기 패널의 오염정도를 쉽게 파악하고 저오염 영역의 즉각적인 청소 및 고오염 영역의 빠른 보고로 인하여 전반적인 태양광 발전 효율을 제고할 수 있으며, 수동으로 이루어지는 인력 관리에 비하여 오염지역 파악 및 제거 시간이 보다 빠르고 정확하게 이루어질 수 있다.