• Title/Summary/Keyword: 입자화상속도계

Search Result 14, Processing Time 0.027 seconds

Experimental study of vertical fence wake with flow separator (Flow separator가 부착된 수직벽 후류유동의 실험적 연구)

  • Choi, Young-Ho;Kim, Hyoung-Bum
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.68-72
    • /
    • 2006
  • Vertical fence has the coherent flow structure in front of the fence. In the present study, the wake change due to the flow separator in front of the vertical fence was experimentally investigated. Quantitative method was applied to study the separated shear flow field. The results show the flow separator changes the downstream shear flow and alters the curvature of separated shear layer As the freestream velocity increased, the reattachment length also increased.

  • PDF

Development of Wall Flow Sensor Using Micro Imaging Device (미세 영상 장치를 이용한 벽면 유동 센서 개발)

  • Lee, Seung Hwan;Kim, Byung Soo;Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1217-1222
    • /
    • 2012
  • A wall flow sensor has been used for feedback flow control and wall shear stress measurement. In this study, we developed a new wall flow sensor by combining the PIV algorithm and the micro image sensor used in an optical mouse. The feasibility of the wall flow sensor was investigated by using simulated fluid flow experiments. Compared with the quadrature signal from imaging devices, the accuracy of the wall flow velocity measurement was improved and the dynamic range increased. In addition, the depth information of particles was also measured by using the defocusing imaging technique.

Experimental study of axial slit wall effect on Taylor-Couette flow (슬릿이 있는 Taylor-Couette 유동의 실험적 연구)

  • Lee, Sang-Hyuk;Kim, Hyoung-Bum
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3183-3186
    • /
    • 2007
  • Taylor-Couette flow may appear when the angular velocity is different between two concentric rotating cylinders. This kind of Taylor-vortex flow can be easily seen in lots of engineering problems. In general the geometries of rotating cylinders are generally complex in these cases. In this study, we investigated Taylor-Couette flow when the outer cylinder has the slit along the annulus. The radius ratio and aspect ratio of the experimental model used was 0.825 and 48, respectively. The depth of slits is 5mm and total 18 slits are azimuthally located along the inner wall of outer cylinder. We used PIV method to measure the flow and applied index matching method to resolve the complex geometry effect. The results show the model with slit has no stable wavy vortex region above Re=143.

  • PDF

In vitro study of downstream flow passing through heart valve prostheses (인공 심장판막 하류 유동의 in vitro 연구)

  • Kim Hyoung-Bum;Lanning Craig
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.1
    • /
    • pp.47-55
    • /
    • 2006
  • The left ventricular filling flow is now considered as an indicator which can be used for early diagnosing of cardiovascular diseases. Because the understanding of left ventricular flow physics is critical for this purpose, the downstream flow characteristics of the artificial heart valve are investigated using particle image velocimetry (PIV) method. In this study, we investigated the wake characteristics of flows passing through three different artificial valves (St.Jude medical bileaflet mechanical valve. Bjork-Shiley monostrut mechanical valve and St.Jude medical Biocor bio valve). The downstream flow field has remarkably altered according to the different valves. SJM MHV has the flow field similar to the pulsating circular jet and BS MHV has oblique pulsating jet. SJM BHV shows the similar flow field of clinical data of normal heart.

  • PDF

Flow Visualization Study around the Distributor of Plate-fin Heat Exchangers (판형-핀 열교환기 분배면의 유동 가시화 연구)

  • Jeong, Tae-Sik;Park, Seung-Ha;Kim, Chang-Su;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.10 no.3
    • /
    • pp.37-41
    • /
    • 2012
  • Plate-fin heat exchanger is a kind of compact heat exchangers with a good performance in heat transfer. It is widely used in various engineering fields such as aerospace, chemical and biomedical industries. Quantitative and qualitative flow visualization study were performed using the water model of commercial plate-fin heat exchanger with header angles of $30^{\circ}$. The Reynolds number was 100. Conventional digital particle image velocimetry was used to measure the instantaneous velocity fields of the header region and the flow visualization using dye injection and hydrogen bubble method were applied to capture the qualitative flow characteristics. The results showed the existence of separation flow region at the junction area and the bottom wall of the exit region.

Experimental Study of Axial Slit Wall Effect on Taylor-Couette Flow (축방향 홈이 있는 Taylor-Couette 유동의 실험적 연구)

  • Lee, Sang-Hyuk;Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.10
    • /
    • pp.889-894
    • /
    • 2007
  • The effect of the axial slit of outer cylinder on Taylor-Couette flow was experimentally investigated. The radius ratio and aspect ratio of the model was 0.825 and 48, respectively. The depth of slits was 5mm and total 18 slits were azimuthally located along the inner wall of outer cylinder. We used PIV method to measure the flow field and applied refractive index matching method to resolve the image distortion due to the complex model geometry. The results showed the axial slit did not affect the transition from laminar Couette flow to Taylor vortex. The effect of slit wall appeared when the Reynolds number is larger than Re=143 and the slit model shows the transition to turbulent Taylor vortex flow above Re=143.

Experimental Investigation of Two-dimensionality of Flow around the Vertical Fence Submerged in a Turbulent Boundary Layer (난류 경계층에 잠긴 수직벽 주위 유동의 2차원성 연구)

  • Cha, Jae-Eun;Kim, Hyoung-Woo;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.8 no.1
    • /
    • pp.13-18
    • /
    • 2010
  • An experimental investigation of the flow around a vertical fence was carried out using a PIV velocity field measurement technique. The vertical fence was embedded in a turbulent boundary layer. The instantaneous velocity fields measured at cross-sectional planes reveal complex longitudinal vortices that vary in size and strength, developing from the upstream location. In the instantaneous vorticity and velocity field data, the shear flow separated from the fence top is highly turbulent and shows unsteady flow characteristics. The topography of the ensemble averaged velocity fields, especially the separation bubble formed behind the fence, shows that the spatial distributions of streamwise velocity (U) and vertical (V) are symmetric, the spanwise velocity (W) is skew-symmetric with respect to the central xy-plane(z=0).

Quantitative Visualization of Inlet Flow of the Centrifugal Blower (원심 블로어 입구 유동의 정량적 가시화 연구)

  • Jeong, Tae-Sik;Tu, Xin Cheng;Kim, Sung-Jun;Jang, Hwan-Young;Kim, Jin-Kwang;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.2
    • /
    • pp.27-33
    • /
    • 2013
  • The inlet flow of centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower system is one of the key parts of EV battery cooling system, the quantitative information of flow field of centrifugal blower is important to design and optimize the cooling system. Two types of inlet parts were used in this study. One is the straight inlet and the other is a bended one. The results showed the flow asymmetry exists in the straight model due to the pressure difference in the blower. In case of the bended one, the separation bubble and the increase of head loss appeared compared with the straight model.

Study of Wake Control by Blowing and Suction in Front of the Vertical Fence (수직벽 전방에서의 흡입/토출을 이용한 후류제어 연구)

  • Choi, Young-Ho;Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.1
    • /
    • pp.47-53
    • /
    • 2008
  • The effect of periodic blowing and suction of upstream flow on the separated shear flow behind the vertical fence was experimentally investigated. The fence was submerged in the turbulent shear flow and DPIV method was used to measure the instantaneous velocity fields around the fence. Periodic blowing and suction flow was precisely generated by the syringe pump. Spanwise nozzle made 2D planar periodic jet flow in front of the fence and the effect of frequency and maximum jet velocity was studied. From the results, the reattachment length can be reduced by 60% of uncontrolled fence case under the control.

Development of the Scanning PIV Method with Single Optical Axis (단일 광경로 스캐닝 PIV기법 개발)

  • Kim, Hyoung-Bum
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.181-187
    • /
    • 2007
  • Conventional PIV method uses two optical axis configuration during the image grabbing process. That is, the illumination plane and the recording plane must be parallel. This configuration is very natural to grab the whole field without the image distortion. In the real problem, it is often to meet the situation when this configuration is hard to be fulfilled. In the present study, the new PIV method which uses only single optical axis to grab the particle images is developed. This new PIV method becomes possible by utilizing the scanning method similar to the echo PIV technique. One particle image of the scanning PIV consists of scanned several line images and by repeating this scanning process, two particle images were grabbed and processed to produce the velocity vectors. An optimization study was performed to find parameters which minimize the measurement errors. The effects of particle diameter, beam overlap ratio and particle number density were investigated.