• 제목/요약/키워드: 입자집진

검색결과 145건 처리시간 0.025초

전기 집진기에서의 Submicron 입자의 집진 특성에 관한 연구-II. 집진 효율 특성 (A Study on the Collection Characteristics of Submicron Particles in an Electrostatic Precipitator - II. Collection Efficiency Characteristics)

  • 김용진;여석준;유주식
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.579-587
    • /
    • 2001
  • This study investigates particle collection characteristics of a cylindrical electrostatic precipitator. Experimental work has been made for the submicron particles. The effects of polarity of discharge electrode wire, particle diameter, gas velocity, gas temperature, and specific corona power on the particle collection efficiency are investigated. The efficiency of negative corona is higher than that of positive corona. as the particle diameter increases, the efficiency is decreased when the diameter is in the range of 0.02-0.6 micron, but is increased for the nanometer particles with diameter smaller than 0.02 micron. The efficiency is increased with increase of specific corona power. As the gas temperature increases, overall collection efficiency is increased for a negative corona, but is deceased for a positive corona.

  • PDF

세라믹캔들필터 집진장치에서의 입구유입방식에 따른 유동장 및 입자거동현상 비교 수치해석 (Computational Simulation for Comparison of Flow Field and Particle Behavior in a Ceramic Candle Filter Housing with Different Inlet Type)

  • 박석주;이동근;임정환;박영옥
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 추계학술대회 논문집
    • /
    • pp.481-482
    • /
    • 2003
  • 세라믹캔들필터 집진장치의 형상 설계 시 장치내의 유동장의 균일도와 필터 표면으로의 입자 부하 현상이 중요한 설계 요소로 다루어지고 있다. 장치 내부의 유동 조건을 조절하여 필터 표면상에 도달하는 입자의 농도를 낮추거나 균일하게 유지시킬 경우, 부착된 입자층 두께의 성장으로 인한 압력손실의 증가율을 줄일 수 있고 이로 인하여 탈진 주기 또한 감소시킬 수 있다. 탈진 조작의 저감으로 인하여 필터의 수명 증대로 필터의 교체 시기를 연장시킬 수 있으므로 세라믹캔들필터 집진장치의 운전 및 유지보수비의 저감을 이룰 수 있다. (중략)

  • PDF

타공판 전기집진기와 유전필터를 조합한 공기청정용 필터의 집진성능 실험 (Experiment of Filtration of an Air-Cleaning Filter Combing an Dielectric Filter to an Electrostatic Precipitator with a Perforated Plate)

  • 박석주;임정환;김상도;최호경;박현설;박영옥
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.413-414
    • /
    • 2001
  • 실내공간에 존재하는 먼지입자를 제거하는데 적용되는 대표적인 방법들로는 섬유상 필터를 이용한 먼지입자 여과 기술과 전기집진기를 이용한 여과 기술이 있다. 섬유상 필터를 이용한 여과 기술은 입자의 관성충돌(inertial impaction), 차단(interception) 및 확산(diffusion) 메카니즘을 이용한 기술로써, 입자포집 효율이 아주 우수한 반면 압력손실이 큰 단점이 있다. 이러한 단점을 개선하기 위하여 개발된 필터로써 정전부착(electrostatic deposition) 메카니즘을 이용한 정전여과필터(electret filter)라고 것이 있는데, 이것은 섬유 자체에 정전 하전을 주입시킨 특수한 필터이다. (중략)

  • PDF

코로나 방전기가 없는 전기집진기의 미세입자 집진에 관한 수치해석 (Numerical Investigation on Capture of Sub-Micron particles in Electrostatic Precipitator without Corona Discharger)

  • 이진운;장재성;이성혁
    • 한국분무공학회지
    • /
    • 제16권2호
    • /
    • pp.69-75
    • /
    • 2011
  • This article presents computational fluid dynamics (CFD) simulations of sub-micron particle movements and flow characteristics in laboratory-scale electrostatic precipitator (ESP) without corona discharge, and for simulation, it uses the commercial CFD program (CFD-ACE) including electrostatic theory and Lagrangian-based equation for sub-micron particle movement. For validation of CFD results, a simple cylindrical type of ESP is simulated and numerical prediction shows fairly good agreement with the analytical solution. In particular, the present study investigates the effect of particle diameter, inlet flow rate, and applied electric potential on particle collection efficiency and compares the numerical prediction with the experimental data, showing good agreement. It is found that the particle collection efficiency decreases with increasing inlet flow rate because the particle detention time becomes shorter, whereas it decreases with the increase in sub-micron particle diameter and with the decrease of applied electric voltage resulting from smaller terminal electrostatic velocity.

Compression Cake내에서의 입자 퇴적 양상에 대한 수치 해석적 연구 (A Numerical Study on the Particle Deposition Morphology in the Compression Cake)

  • 전기준;정용원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2000년도 춘계학술대회 논문집
    • /
    • pp.211-212
    • /
    • 2000
  • 여과집진기(fabric filter)는 높은 집진 효율로 인해 대형소각로를 포함한 환경시설의 집진 설비로 많이 적용되고 있으며, 그 중에서 pulse-jet형 여과집진기가 가장 많이 사용되는 추세이다 한편, 여과포 표면에 형성되는 dust cake의 퇴적성상(deposition morphology)은 여과집진기의 압력손실에 매우 큰 영향을 미치는데, 일정 여과속도에서 dust cake의 압력손실이 상대적으로 큰 경우에는 탈진주기가 필연적으로 짧아지는 결과를 초래한다. (중략)

  • PDF

배리어 유전체 방전을 이용한 전기 집진부에서의 나노 입자 집진 효율 (Collection Efficiency of Nano Particles by Electrostatic Precipitator using Dielectric Barrier Discharge)

  • 강석훈;지준호;변정훈;황정호
    • 대한기계학회논문집B
    • /
    • 제27권11호
    • /
    • pp.1542-1547
    • /
    • 2003
  • Although dielectric barrier discharge (DBD) in air has been applied to a wider range of aftertreatment processes for HAPs (Hazardous Air Pollutants), due to its high electron density and energy, its potential use as precharging dust particles is not well known. In this work, we measured size distributions of bimodal aerosol particles and estimated collection efficiency of the particles by an electrostatic precipitator (ESP) using DBD as particle charger. To examine the particle collection with DBD charger, nano size particles of NaCl(20∼100nm) and DOS (50∼500nm) were generated by a tube furnace and an atomizer, respectively. For experimental conditions of 60㎐, 11㎸ and 60 lpm, the particle collection efficiency for the hybrid system was over 85%, based on the number of particles captured.

배리어 유전체 방전을 이용한 전기 집진부에서의 나노 입자 집진 효율 (Collection Efficiency of Nano Particles by Electrostatic Precipitator using Dielectric Barrier Discharge)

  • 강석훈;변정훈;지준호;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1435-1440
    • /
    • 2003
  • Although Dielectric Barrier Discharge (DBD) in air has been applied to a wider range of aftertreatment processes for HAPs(Hazardous Air Pollutants), due to its high electron density and energy, its potential use as precharging dust particles is not well known. In this work, we measured size distributions of bimodal aerosol particles and estimated collection efficiency of the particles by electrostatic precipitator(ESP) using DBD as particle charger. To examine the particle collection with DBD charger, nano size particles of NaCl($20{\sim}100$ nm) and DOS($50{\sim}800$ nm) were generated by tube furnace and atomizer, respectively. For experimental conditions of 60 Hz, 11 kV, and 60 lpm, the particle collection efficiency for the hybrid system comprising DBD charger and ESP was over 85 %, based on the number of particles captured.

  • PDF

충진층식 세정집진기의 집진특성 실험 (An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber)

  • 유경훈;노희환;최은수;김종균
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

유전체 베리어 방전형 2단 전기집진기의 인가전압 파형별 나노 및 서브마이크론 입자 집진 특성 (Nano and Submicron Sized Particle Collection with Various Voltage Waveforms for Dielectric Barrier Discharge Type 2-Stage ESP)

  • 박재홍;변정훈;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1261-1266
    • /
    • 2004
  • Dielectric Barrier Discharge (DBD) in air, which has been established for the production of large quantities of ozone, is more recently being applied to a wider range of aftertreatment processes for HAPs (Hazardous Air Pollutants). Although DBD has high electron density and energy, its potential use as precharging nano and submicron particles are not well known. In this work, we measured I-V characteristics of DBD and estimated collection efficiency of the particles by DBD type 2-stage ESP. To examine the particle collection with various applied voltage waveforms of DBD for nano and submicron sized, bimodal particles were generated by a electrical tube furnace and an atomizer.

  • PDF

사이클론 전처리부를 지닌 터널집진차량의 집진효율 최적화 (Dust collection optimization of tunnel cleaning vehicle with cyclone-based prefilter)

  • 정우태
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.679-686
    • /
    • 2018
  • 지하철 터널 내에 축적된 미세먼지와 초미세먼지를 제거하기 위해서는 새로운 형식의 분진흡입차량이 필요하다. 따라서 최근 개발된 분진흡입차는 초미세먼지 제거를 위한 흡입시스템과 사이클론형식의 전처리부 및 전기집진기를 장착하고 있다. 본 논문에서는 집진차량의 하부에 설치된 먼지 흡입시스템이 다양한 크기의 먼지입자를 효과적으로 흡입하고 처리하기 위해 사이클론형식의 전처리부가 포함된 집진시스템을 설계하고 집진효율을 ANSYS FLUENT의 전산유체해석을 통해 확인하였다. 흡입구와 사이클론형 프리필터가 연결된 격자모델을 기반으로 공기유동과 상차분모델(Discrete Phase Model)을 이용하여 다양한 입자의 크기와 종류 및 흡입팬의 용량에 따른 입자의 거동을 해석하였다. 다양한 입자의 크기와 종류, 흡입팬의 용량에 대해서 해석결과 집진차량의 운영속도 5km/h에서 미세먼지처리를 위해서는 흡입팬의 용량 $1500m^3/min$에서 흡입구가 궤도면으로부터 약 100mm이내일 때 $100{\mu}m$ 이하 크기의 먼지를 모두 처리할 수 있음을 확인하였다. 이러한 흡입구와 사이클론형식의 프리필터를 탑재한 터널집진차량은 후단에 설치된 전기집진기의 부하를 줄이고, 지하 터널내의 미세먼지와 초미세먼지의 제거에 효과적으로 활용될 수 있을 것으로 기대된다.