• Title/Summary/Keyword: 입자분리

Search Result 906, Processing Time 0.027 seconds

Studies on Viruses Isolated from Lilium spp. In Korea I. Broad Bean Wilt Virus and Cucumber Mosaic Virus (한국산 나리류에서 분리한 바이러스에 관한 연구 I. Broad Bean Wilt Virus 및 Cucumber Mosaic Virus)

  • Chang Moo Ung;Chung Jae Dong
    • Korean Journal Plant Pathology
    • /
    • v.3 no.3
    • /
    • pp.223-235
    • /
    • 1987
  • Samples showing yellow mosaic symptom of Lilium spp. with necrotic fleck, stunting, malformation, and colour breaking were collected from lily-growing areas in the southern part of Korea. Two viruses were distinguished under a electron microscope and their host range, serological reaction, stability in sap, type of aphid transmission, and relations with cells and tissues were examined. Broad bean wilt virus (BBWV) was transmitted by sap-inoculation to 23 plant species in 8 families and by the aphid, Myzus persicae. This virus was inactivated after 10 min at 70C, at dilution of $10^{-3}$, and after 6 days at about 20C. Electron microscopic examination of purified preparation showed that the virus is spherical particle of 28nm in diameter. The virus reacted positively with BBWV-antiserum in agar gel diffusion test. In ultrathin sections of BBWV infected tissues, large aggregates or crystalline array of virus particles and vesicular body were found in the cytoplasm, vacuole, and nucleus of mesophyll cells. Cucumber mosaic virus (CMV) was transmitted by sap-inoculation. Electron microscopic examination of its purified preparation showed spherical particles of 30nm in diameter. The virus reacted positively with CMV-Y strain-antiserum in agar gel diffusion test. In ultrathin sections of CMV infected tissues, crystalline array of virus particles were found in the vacuole and a large number 0f virus particles were found in the cytoplasm and the plasmodesmata of mesophyll cells. When each of these viruses was retransmitted to Lilium tigrinum. L. concolor, and L. auratum, BBWV induced slight symtoms and colour breaking, but CMV induced yellowing mosaic or necrotic fleck.

  • PDF

Performance Evaluation of Hydrocyclone Filter for Treatment of Micro Particles in Storm Runoff (Hydrocyclone Filter 장치를 이용한 강우유출수내 미세입자 제거특성 분석)

  • Lee, Jun-Ho;Bang, Ki-Woong;Hong, Sung-Chul
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.11
    • /
    • pp.1007-1018
    • /
    • 2009
  • Hydrocyclone is widely used in industry, because of its simplicity in design, high capacity, low maintenance and operational cost. The separation action of a hydrocyclone treating particulate slurry is a consequence of the swirling flow that produces a centrifugal force on the fluid and suspended particles. In spite of hydrocyclone have many advantage, the application for treatment of urban stormwater case study were rare. We conducted a laboratory scale study on treatable potential of micro particles using hydrocyclone filter (HCF) that was a combined modified hydrocyclone with perlite filter cartridge. Since it was not easy to use actual storm water in the scaled-down hydraulic model investigations, it was necessary to reproduce ranges of particles sizes with synthetic materials. The synthesized storm runoff was made with water and addition of particles; ion exchange resin, road sediment, commercial area manhole sediment, and silica gel particles. Experimental studies have been carried out about the particle separation performance of HCF-open system and HCF-closed system. The principal structural differences of these HCFs are underflow zone structure and vortex finder. HCF was made of acryl resin with 120 mm of diameter hydrocyclone and 250 mm of diameter filter chamber and overall height of 800 mm. To determine the removal efficiency for various influent concentrations of suspended solids (SS) and chemical oxygen demand (COD), tests were performed with different operational conditions. The operated maximum of surface loading rate was about 700 $m^3/m^2$/day for HCF-open system, and 1,200 $m^3/m^2$/day for HCF-closed system. It was found that particle removal efficiency for the HCF-closed system is better than the HCF-open system under same surface loading rate. Results showed that SS removal efficiency with the HCF-closed system improved by about 8~20% compared with HCF-open system. The average removal efficiency difference for HCF-closed system between measurement and CFD particle tracking simulation was about 4%.

Effect of Crystal Particle Deposition on Morphology of Zeolite Membrane and its Separation Performance (결정입자 도포가 제올라이트 막 구조 및 분리성능에 미치는 영향)

  • Lee, Yong-Taek;Jeong, Heon-Kyu;Jeong, Dong-Jae;Yun, Mi-Hye;Ahn, Hyo-Seong
    • Membrane Journal
    • /
    • v.18 no.3
    • /
    • pp.198-205
    • /
    • 2008
  • A novel technology for homogeneous deposition of zeolite particles on a porous support was developed so that those particles played a seeding role for the growth of zeolite crystals. After the particles were dispersed in water, the aqueous solution was 134 through the bore of a porous tubular support. By keeping the other side of the support in a vacuum, the aqueous solution passed through the pores of the support, leading the particles to be homogeneously deposited on the support. The amount of the deposited particles was investigated by changing the following operating parameters: a particle concentration in the solution, a time for deposition, and the feeding rate of the solution. The amount of the deposited particles increased from 0.0019 g to 0.0208 g as the concentration of the particles was changed from 0.01 wt% to 0.3 wt%, while the feeding rate and the deposition time were kept to 100 mL/min and 4 min, respectively. As the deposition time was varied from 1 min to 4 min, the deposition amount increased from 0.0004g to 0.0019g at the typical condition of the rest parameters. Also, it was observed that the deposited weight increased from 0.0029 g to 0.01 g as the feeding rate increased from 100 mL/min to 300 mL/min. However, the total permeance of water and ethanol decreased through the zeolite membrane as the deposited weight increased.

A Study on the Removal of Phenol by Hybrid Process coupling adsorption with microfiltration (흡착과 정밀여과의 혼성공정에 의한 페놀 제거에 관한 연구)

  • ;;Fane, A. G.
    • Membrane Journal
    • /
    • v.6 no.2
    • /
    • pp.109-116
    • /
    • 1996
  • This work is a fundamental study for applying hybrid process coupling adsorption with microfiltration to waste-water treatment. Phenol was separated by adsorption on powdered activated carbon, adsorbed phenol with activated carbon was separated by microfiltration. As the particle size in suspension increased, filtration resistance decreased, and effect of particle concentration on resistance was less pronounced. The rate of uptake was greatly dependent on the degree of phenol loading. For a smaller amounts of activated carbon, the change of permeate concentration before break point and phenol loading with time were steeper than in the case of large amounts. Permeate concentration before break point decreased with decreasing particle size, this could be due to the increase of outer surface of particle and film mass transfer coefficient.

  • PDF

Development of a PTV Algorithm for Measuring Sediment-Laden Flows (유사 흐름 측정을 위한 입자추적유속계 알고리듬의 개발)

  • Yu, Kwon-Kyu;Muste, Marian;Ettema, Robert;Yoon, Byung-Man
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.10 s.159
    • /
    • pp.841-849
    • /
    • 2005
  • Two-phase flows, e.g. sediment-laden flow and bubbly flow, have two different flow profiles; flow velocity and sediment velocity. To measure velocity distributions of two-phase flows, it is necessary to use sophisticated instruments which can separate velocity profiles of two-phases. For bubbly flows, PIV (Particle Image Velocimetry) or PTV (Particle Tracking Velocimetry) has given fairly good velocity profiles of two-phases. However, for sediment-laden flows, the applications of PIV or PTV has not been so successful, because the sediment particles introduced to the flow kept the images from being analyzed. A new algorithm, which consists of several image analysis methods, is proposed to analyze sediment-laden flows. For detection algorithm, threshold method, edge detection method, and thinning method are adapted, and for finding matching pair PIV and PTV routines are combined. The proposed method can (1) detect sediment particles with irregular boundaries, (2) remove reflected images and scattered images, and (3) discriminate tracer particles from reflected images of sediment particles.

폐전선 피복플라스틱 재활용을 위한 PVC, Rubber의 하전특성 연구

  • Jeon, Ho-Seok;Park, Cheol-Hyeon;Kim, Byeong-Gon;Park, Jae-Gu
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2005.05a
    • /
    • pp.375-376
    • /
    • 2005
  • 본 연구에서는 폐전선 피복플라스틱의 재활용을 위해 마찰하전형 정전선별법을 이용하여 PVC와 rubber의 재질분리 실험을 수행하였다. 하전물질의 종류에 따른 실험결과 PVC와 Rubber의 중간 일함수 값을 갖고 있는 PP 재질이 가장 효과적이었으며, 단일 시료보다PVC와 Rubber의 혼합조건에서 더 높은 하전 값을 나타내었다. 하전특성 실험결과 공기량은 10.28wt/s 이상 그리고 상대습도는 40% 이하의 조건에서 입자의 높은 하전량을 얻을 수 있음을 확인하였다. 분리특성 실험결과 전압세기가 25kv 이상 그리고 분리대의 위치는 전기장의 중앙(0)으로부터 Negative 전극으로 -lcm 이동한 지점으로, 이때 PVC의 품위와 회수율을 각각 99.5%와 95%인 결과를 얻었다.

  • PDF

Fine Crushing Characteristics of Concrete Wastes (콘크리트 폐기물의 분쇄 특성 연구)

  • 오중환;이효숙;정헌생
    • Resources Recycling
    • /
    • v.5 no.2
    • /
    • pp.52-56
    • /
    • 1996
  • Fix crushing characteristics of construction concrete wastes wcrc rnvcstigatcd in order to scparate the natural aggregatcs. A roll crushcr and a hammcr crusher wcrc used to granulate pre-crushed concrete\ulcorner below 30 rnm The crushers pruducc finer sizes far ccmcnt concrete than for asphalt concrele, and the hammer crushing resulls in separating the aggregales from thc olhers better than thc roll crushing. The narural aggregatcs of orcr 70-90% by volume were obtained from the concretes by using a riffled shaking table.

  • PDF

CFD Validation of Solid-Liquid Two-Phase flow for Analysis of Drilling Fluid Flow Characteristics (이수의 유동 특성 분석을 위한 고체-액체 2상 유동의 전산유체역학적 유효성 검토)

  • Choi, Yong-Seok;Park, Jae-Hyoun;Bae, Jae-Hwan;Lee, Bong-Hee;Kim, Jeong-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.611-618
    • /
    • 2018
  • In this study, numerical analysis of solid-liquid two-phase flow was conducted as a preliminary step to analyze the flow characteristics of drilling fluid using the commercial CFD code, ANSYS CFX 14.5. The homogeneous model and separated flow model were used to simulate solid-liquid two-phase flow phenomena. In the separated flow model, Gidaspow's drag force model was applied with the kinetic theory model was applied for solid particles. The validity of the numerical model used in this study was verified based on the published experimental results. Numerical analysis was carried out for volume fractions of 0.1 to 0.5 and velocities of 1 to 5 m/s in a horizontal tube with a diameter of 54.9 mm and a length of 3 m. The Pressure drop and volume fraction distribution of solid particles were confirmed. The pressure drop was predicted using the homogeneous model and separated flow model within the MAE of 17.04 % and 8.98 %, respectively. A high volume fraction was observed in the lower part of the tube, and the volume fraction decreased toward the upper part. As velocity increased, variations in volume fraction distribution at varying heights were decreased, and the numerical results predicted these flow characteristics well.

Isolation Method of Mushroom Infesting Pests from Mushroom-Growing Compost (버섯배지에서 버섯해충류 분리방법)

  • Lee, Heung-Su;Kim, Kyu-Jin;Song, Geun-Woo;Kim, Jin-Ho
    • The Korean Journal of Mycology
    • /
    • v.27 no.4 s.91
    • /
    • pp.289-292
    • /
    • 1999
  • We investigated the isolation method of mushroom infesting pests, Lycoriella mali, Coboldia fuscipes, Histiostoma sp. from mushroom-growing compost. Sugar solution of different densities (0, 10, 20, 30, 40, 50%) was tested to provide a means of seperating mushroom pests from the compost media. Thus, 40% sugar solution was suitable for isolation. The sieve size to entrap the pests was $30{\sim}140$ mesh; Lycoriella mali was trappped mainly $30{\sim}65$ mesh sieve, Coboldia fuscipes was caught mainly $30{\sim}100$ mesh sieve, Histiostoma sp. was trapped mainly $65{\sim}140$ mesh sieve. An isolation procedure was as follows; The infested compost was disintegrated in water and poured onto a set of 16, 30, 80, 140-mesh sieve. The material caught in the sieve is added in 40% sugar solution and then most compost particle were massed at the bottom while the supernatant contains mushroom pests. The upperlayer material was poured into a Seperatory funnel and the sediment at the bottom is drained off. The remaining material are washed off examination dish for study.

  • PDF

Highly-permeable Mixed Matrix Membranes Based on SBS-g-POEM Copolymer, ZIF-8 and Ionic Liquid (SBS-g-POEM 공중합체, ZIF-8, 이온성 액체에 기반한 고투과성 혼합 매질 분리막)

  • Kang, Dong A;Kim, Kihoon;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.29 no.1
    • /
    • pp.44-50
    • /
    • 2019
  • In this paper, we developed mixed matrix membranes (MMMs) consisting of SBS-g-POEM block-graft copolymer, ionic liquid (EMIMTFSI) and ZIF-8 nanoparticles to separate a $CO_2/N_2$ gas pair. The SBS-g-POEM is a rubbery block-graft copolymer synthesized through low-cost free-radical polymerization. The EMIMTFSI was dissolved into the SBS-g-POEM matrix and solution synthesized ZIF-8 nanoparticles were also dispersed into the copolymer matrix. The physico-chemical properties of manufactured membranes were characterized by Fourier transform infrared spectroscopy (FT-IR), differential scanning calorimetry (DSC), scanning electron microscopy (SEM), X-ray diffraction (XRD), which showed that the components were compatible with each other. The gas separation performance was confirmed by time-lag measurements showing $CO_2$ permeability of 537.0 barrer and $CO_2/N_2$ selectivity of 15.2. The result represents the EMIMTFSI and ZIF-8 nanoparticles improves the gas permeability more than two-times, without significantly sacrificing the $CO_2/N_2$ selectivity.