• Title/Summary/Keyword: 입구영역

Search Result 166, Processing Time 0.025 seconds

Turbulent Statistics of the Turbulent Boundary Layer over a Cube-Roughened Wall (3 차원 입방형 표면조도가 난류경계층에 미치는 영향)

  • Lee, Jae-Hwa;Sung, Hyung-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.10
    • /
    • pp.917-923
    • /
    • 2010
  • Direct numerical simulation (DNS) of a spatially developing turbulent boundary layer (TBL) with regularly arrayed cubical roughness elements was performed to investigate the effects of three-dimensional (3D) surface elements. The staggered cubes downstream were periodically arranged in the streamwise and spanwise directions with pitches of $p_x$/k=8 and $p_z$/k=2, where $p_x$ and $p_z$ are the streamwise and spanwise spacings of the cubes; the roughness height (k) was k=$1.5{\theta}_{in}$, where ${\theta}_{in}$ is the momentum thickness at the inlet. Spatially developing characteristics over the 3D cubical roughness were compared with the data obtained from the DNS over the two-dimensional (2D) rod roughened wall and smooth wall. Introduction of the cubical roughness on the TBL affected the turbulent Reynolds stresses not only in the roughness sublayer but also in the outer layer; and these effects are consistent with those observed over the 2D rough wall.

Air Sampling For Volatile Organics Using an Adsorbent (흡착제를 이용한 휘발성 유기물 채취)

  • ;L.R.Berrafato
    • Journal of Environmental Science International
    • /
    • v.1 no.1
    • /
    • pp.41-46
    • /
    • 1992
  • To perform a long-term ambient sampling study at a residential site, an air sampler was constructed to collect 24-hour integrated air samples suitable for the volatile organic compounds (VOCs) analysis. It includes an esthetically acceptance due to proximity to homes, as fell as providing the required sampling specifications. The VOCs sampler accomodates four 5/8 "stainless steel(SS) traps packed with adsorbent(Tenax) and is capable of four flow rates in the range of 5 to 50 cc/min. Sintered metal filters(10 micrometer) were directly connected to the inlet of the trap adapters. Additional specifications include: 1) constructed of organically inert materials, 2) weatherproof, 3) battery operated, 4) collecting of VOCs at a breathing zone level, and 5) quiet operation with micro diaphragm pumps wrapped by the sponge. The pump/battery system was separated from the sampling shelter. Sound levels measured for this system were below permissible sound levels (NJDEP) at a residential site. The sampler has been successfully operated at both ground level in a residential area and on the roof of a one story elementary school.hool.

  • PDF

Three-dimensional Flow and Aerodynamic Loss Downstream of First-Stage Turbine Vane Cascade (터빈 제1단 정익 익렬 하류에서의 3차원 유동 및 압력손실)

  • Jeong, Jae Sung;Bong, Seon Woo;Lee, Sang Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.41 no.8
    • /
    • pp.521-529
    • /
    • 2017
  • Three-dimensional flow characteristics within a high-acceleration first-stage turbine vane passage has been investigated in a newly-built vane cascade for propulsion. The result shows that there is a strong favorable pressure gradient on the vane pressure surface. On its suction surface, however, there exists not only a much stronger favorable pressure gradient than that on the pressure surface upstream of the mid-chord but also a subsequent adverse pressure gradient downstream of it. By employing two different oil-film methods with upstream coating and full-coverage coating, a four-vortex model horseshoe vortex system can be identified ahead of each leading edge in the cascade, and the separation line of inlet boundary layer flow as well as the separation line of re-attached flow is provided as well. In addition, basic flow data such as secondary flow, aerodynamic loss, and flow turning angle downstream of the cascade are obtained.

Heat Transfer Characteristics of Supercritical $CO_2$ in Helical Coil Gas Coolers on the Change of Coil Diameters (코일직경변화에 따른 헬리컬 코일형 가스냉각기내 초임계 이산화탄소의 냉각열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.44-48
    • /
    • 2007
  • The cooling heat transfer characteristics of supercritical $CO_2$ in a helical coil gas cooler on the change of coil diameters are experimentally investigated. The main components of the refrigerant loop are a receiver, a variable speed pump, a mass flow-meter, a pre-heater and a helical coil gas cooler (test section). The test sections are made of a copper tube which the inner diameter is 4.55 mm and the helical coil diameters are done of 26.75 mm and 41.35 mm. The mass fluxes of refrigerant are varied from 200 to 800 [$kg/m^2s$] and the inlet pressures of gas cooler are 7.5 to 10.0 (MPa). A gas cooler with helical coil diameter of 26.75 mm has larger heat transfer coefficient than that of 41.35 mm. Also, when compared with experimental data and published correlations avaliable, most of correlations are under-predicted, but Pitla published correlations avaliable, most of correlations are under-predicted, but Pitla et al.'s correlation shows a relatively good coincidence with the experimental data except the region of pseudo critical temperature.

  • PDF

Heat Transfer Characteristics of Carbon Dioxide in a Inclined Helical Coil Type Heat Exchanger with Inner Diameter Tube of 4.55 mm (내경 4.55 mm의 경사진 헬리컬 코일형 열교환기내 이산화탄소의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.3
    • /
    • pp.1-6
    • /
    • 2007
  • The heat transfer coefficient and pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver, a variable-speed pump, a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube, which is specified as the inner diameter of 4.55 mm. The refrigerant mass fluxes were varied from 200 to $600kg/m^2s$ and the inlet pressures of gas cooler were done 7.5 to 10.0 (MPa). The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increase with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows relatively good coincidence with those predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ is well coincident with the correlation by Pitla et al. However, at the region near pseudo-critical temperature, the experiments indicate higher values than the Pitla et al. correlation.

  • PDF

Dynamic Characteristics of Pintle Nozzle about Changes of Chamber Boundary Condition (연소실 경계조건 변화에 따른 핀틀 노즐의 동특성 연구)

  • Jeong, Kiyeon;Kang, Dong-Gi;Lee, Daeyeon;Choi, Jaesung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.5
    • /
    • pp.22-31
    • /
    • 2018
  • In this study, numerical simulations were performed to determine the dynamic characteristics of a pintle nozzle, with changes to the chamber boundary conditions. To apply movement, to the pintle, the nozzle and pintle were created separately by an auto-grid generation program using an overset grid method. The chamber boundary conditions were selected between a constant mass-flow rate condition and a propellant burn-back condition. The pressure and thrust characteristics of the constant mass-flow rate condition were determined by changing the ratio of the mass-flow rate in the inlet. The propellant burn-back condition was considered by formulation of the combustion rate. The burn-back conditions represented nonlinear phenomena, unlike the constant mass flow rate, and a small flow rate resulted in a large change in the chamber pressure.

Tidal current and river plume distribution characteristics before and after the development of the Kwangyang Bay (광양만 개발 전·후 조류 및 하천유출류 변동 특성)

  • Kim, Cha Kyum
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.102-102
    • /
    • 2021
  • 광양만의 해수교환은 주로 여수해만을 통해 이루어지고, 만의 동측에는 노량수로를 통해 진주만으로의 해수교환이 일어나고 있으며, 만의 북측에는 섬진강을 끼고 있다. 광양항 건설 전 만내의 수심은 약 10 m 이내로 얕았으며, 만의 입구인 여수해만과 노량수로에서의 수심은 약 20 m 이상이었다. 광양만은 1982년 광양제철소의 건설을 시점으로 하여 광양항의 확장 개발, 폐기물처리장 건설 등으로 인한 매립이 진행되었다. 특히, 섬진강 하구는 광양만 개발 전에는 넓은 조간대 퇴적층의 발달로 다양한 생태계환경을 유지하고 있었으나, 광양항 건설 및 하구에서 모래 준설 등으로 인해 근래에 와서는 해수의 역류가 심각한 상태이다. 1982년 광양제철소 건설이후 계속적으로 광양만을 개발함으로써 해양환경에 큰 변화가 발생하였다. 따라서, 본 연구에서는 광양만 개발 전·후의 조석 및 해수유동의 변화특성을 해석하기 위해 조석 및 조류에 대한 현장관측과 3차원 해수유동 수치모형실험을 수행한 후 남해도를 둘러싸고 있는 광양만, 진주만 등의 조석 및 조류의 변동특성을 해석하였다. 광양만 개발 전·후의 해수유동의 변동특성을 해석하기 위해 김 등(1999)에 의해 개발된 3차원 layer·level 혼성 해수유동 모델을 광양만, 진주만을 포함하는 남해도 주변해역에 적용하여 30일간의 수치계산결과를 이용하여 해수유동의 변동특성을 해석하였다. 모델에서 격자간격은 동서-남북방향 동일하게 200 m, 시간간격은 20 sec, 계산영역은 동서방향으로 52 km, 남북방향으로 65 km인 260×325 격자체계로 구성 운영하였다. 외해 개방경계에서 조위는 수로국에서 관측한 조위와 본 연구에서 관측한 조위를 보간하여 사용하였다. 광양만 개발전·후의 조류의 변동특성을 수치해석한 결과 여수해만에서는 광만만 개발전이 개발 후보다 유속이 강하게 나타났으나, 노량수로에서는 개발 후가 개발전보다 유속이 훨씬 강하게 나타났다. 이와 같은 현상은 광양만 개발로 광양만으로 유입되는 조량이 감소함으로 인해 여수해만에서는 유속이 감소한 것으로 생각된다. 노량수로에서 개발 후가 개발전보다 유속이 증가한 것은 여수해만을 통해 유입한 해수가 개발 후에는 광양만의 해수면적 감소로 광양만의 서측으로 유입하는 조량이 감소한 반면에 광양만의 북측(섬진강 하구) 또는 동측(노량수로)으로 유입하는 조량이 많기 때문인 것으로 사료된다.

  • PDF

Prediction of Isothermal and Reacting Flows in Widely-Spaced Coaxial Jet, Diffusion-Flame Combustor (큰 지름비를 가지는 동축제트 확산화염 연소기내의 등온 및 연소 유동장의 예측)

  • O, Gun-Seop;An, Guk-Yeong;Kim, Yong-Mo;Lee, Chang-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.7
    • /
    • pp.2386-2396
    • /
    • 1996
  • A numerical simulation has been performed for isothermal and reacting flows in an exisymmetric, bluff-body research combustor. The present formulation is based on the density-weighted averaged Navier-Stokes equations together with a k-epsilon. turbulence model and a modified eddy-breakup combustion model. The PISO algorithm is employed for solution of thel Navier-Stokes system. Comparison between measurements and predictions are made for a centerline axial velocities, location of stagnation points, strength of recirculation zone, and temperature profile. Even though the numerical simulation gives acceptable agreement with experimental data in many respects, the present model is defictient in predicting the recoveryt rate of a central near-wake region, the non-isotropic turbulence effects, and variation of turbulent Schmidt number. Several possible explanations for these discrepancies have been discussed.

THE NITROUS OXIDE CONCENTRATION IN BREATHING ZONE ACCORDING TO SCAVENGING METHODS DURING DEEP SEDATION OF PEDIATRIC DENTAL PATIENTS (소아치과 환자의 깊은 진정시 호기가스 제거 방법에 따른 호흡대역에서 Nitrous Oxide 농도 변화)

  • Lee, Chung-Won;Yoon, Hyung-Bae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.1
    • /
    • pp.124-131
    • /
    • 2003
  • The concentration of nitrous oxide in dental environment has increased especially in pediatric department. In pediatric department frequently met the behavior disordered patients who need the deep sedation. As the deeply sedated patients could not respond well to verbal command, the amount of mouth breathing would be increased especially with mouth prop which backward transposition of mandible. Inhalation of low concentration of nitrous oxide for a long duration has caused various side effects such as spontaneous abortion and inhibition of methionine synthetase activity which is harmful to DNA synthesis. For evaluation of factors of mouth breathing during deep sedation. The author measured the concentration of nitrous oxide in breathing zone by the change of the scavenging methods. One is drain the gas through the tail part of reservoir bag of Jackson Ree's system naturally. Another is scavenge from tail portion of reservoir bag with negative pressure. Last one is scavenge from nasal mask with negative pressure. The nitrous oxide concentration in breathing zone was the lowest in nasal part drainage but high above the recommended concentration of NIOSH. The order of nitrous concentration in breathing zone was: natural drainage, tail part with negative pressure, nasal part with negative pressure. This would reflect the order of resistance of nasal airway and showed the amount of mouth breathing. From the above experiment, the resistance of nasal airway by the increment of gas flow in corrugating tube and reservoir bag would be one of the causative factors of mouth breathing in deeply sedated patients.

  • PDF

Studies on the Investigation into Original Form of Natural Monument No.404 Orijangnim in Jacheon-ri, Yeongcheon (천연기념물 제404호 영천 자천리 오리장림의 원형 규명)

  • Lim, Won-Hyeon
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.31 no.3
    • /
    • pp.83-94
    • /
    • 2013
  • The purpose of this study is to offer basic data about prototype conservation of the Orijangnim, natural monument No. 404. For this study, March to August 2010, was a literature surveys and field research, and based on this, the Delphi survey of local residents and experts meeting were diagnosed with forest back ground, spatial extent, in the form of forests, flora and vegetation of the surrounding area, so examined closely the original form. Range of the Orijangnim was presumed from Jacheon middle school entrance($N36^{\circ}05^{\prime}59.9^{{\prime}{\prime}}/E128^{\circ}54^{\prime}32.9^{{\prime}{\prime}}$) to Odong of Hwabukmyeon village entrance($N36^{\circ}05^{\prime}31.0^{{\prime}{\prime}}/E128^{\circ}54^{\prime}32.5^{{\prime}{\prime}}$). The Orijangnim in the original form of the existing forest surrounding the village along gohyeon river going back a long S-shaped about 2km is considered. The investigated vascular plants consist of total 198 taxa : 2 forms, 20 varieties, 179 species, 152 Genera, 72 Families. Most of the 60 kinds of large land plants lots of whole plants accounted for 33.3%. A main vegetation of the Orijangnim have been distributed 473 objects of 21 species, and evergreen conifers is 19% to 92 objects, on the other hand, deciduous broadleaf tree is 79% to 373 objects, so the Orijangnim can be maxed forest that deciduous broadleaf tree is dominant. When consider the composition purpose of forest, environment of location, tree size, surrounding flora and vegetation, because an original vegetation of Orijangnim is suggested Zelkova serrata, Salix glandulosa, Celtis sinensis Pers., Quercus variabilis, Quercus acutissima , Sophora japonica L., Cornus walteri Wanger. we must restore around such species of tree. Cedrus deodara (Roxb.) Loudon, Chaenomeles sinensis, Prunus yedoensis Matsum., Ginkgo biloba , Pinus thunbergii Parl., Populus tomentiglandulosa T. Lee is considered to have been planted in the last.