• Title/Summary/Keyword: 입구

Search Result 1,779, Processing Time 0.028 seconds

Hydrodynamic Entrance Lengths and Entrance Correction Factors for a POWER-LAW Fluid in a Circular Duct (원관에서 POWER-LAW 유체의 수력학적 입구길이와 입구보정계수에 관한연구)

  • 오광석
    • The Korean Journal of Rheology
    • /
    • v.7 no.3
    • /
    • pp.261-266
    • /
    • 1995
  • 원관에서 power-law 유체에 대하여 수력학적 입구길이와 입구보정계수를 측정할수 있는 새로운 방법이 개발되었다. 유변학적 성질을 측정할수 있는 긴관과 입구보정계수를 측 정할수 있는 짧은 관을 가진 새로운 모세관 점도계를 이용하여 증류수를 실험한 결과 유변 학적 성질과 입구 보정계수가 표준값과 비교하여 1%안의 오차를 얻었다. Power-law 유체 에 대한 해석 및 실험결과(Carbopol 960 용액)도 이미 보고된 값과 $\pm$6% 이내로 잘 일치하 였다.

  • PDF

Flow and Heat Transfer Characteristics of Heat Exchanger Tube Bank with the Sinusoidal Inlet Velocity (정현파 입구 속도 변동에 따른 열교환기 관군의 유동 및 열전달 특성)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.1
    • /
    • pp.14-19
    • /
    • 2021
  • The change of the vorticity and the temperature distribution in heat exchanger tube bank were analyzed for the flows with the constant inlet velocity and the sinusoidal inlet velocity. The flow frequency characteristics were examined by analyzing power spectral density of lift and drag at a typical circular tube in the tube bank. Karman vortex street could be seen at the upstream region of tube bank for the case of constant inlet velocity. It could be seen that the Karman vortex street was affected by the change of inlet velocity near the circular tubes for the case with the sinusoidal inlet velocity. It was observed that the unsteady temperature distributions for both inlet velocity conditions had almost the same motion as the flow vorticity behavior. The flow frequency for the case with the constant inlet velocity is 37.25Hz, and that with the sinusoidal inlet velocity, the flow frequency is 18.63Hz, which is equal to the sinusoidal inlet velocity. The mean surface Nusselt number(Nu) for overall heat exchanger tube bank was 1051 for the case with the constant inlet velocity and 1117 for the case with the sinusoidal inlet velocity. From the result of heat transfer analysis, it could be seen that Nu with the sinusoidal inlet velocity showed 6.3% increase than that with the constant inlet velocity.

Optimal inlet shape design of air handling unit using CFD (유동해석을 사용한 공조기 입구형상의 최적설계)

  • 최영석;이용갑;주종일
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.108-112
    • /
    • 2001
  • 본 논문에서는 전산유체해석 기법을 이용하여 저소음ㆍ고효율 공조기의 입구형상에 대한 유동해석을 하였다. 공조기 입구형상을 결정하는 여러 설계변수가 입구와 출구의 유동조건과 유로의 압력손실에 미치는 영향을 평가하였다. 이를 바탕으로 입구와 출구유동의 균일성과 압력손실의 최소화를 만족하는 최적의 설계 변수를 결정하여 공조기의 최적설계를 달성하였다.

Turbomachinery Inlet Flow Measurement without the Effect of Instrumentation (입구 Instrumentation의 영향을 최소화하는 터보기계 성능측정방법)

  • Kang, Jeong-Seek;Ahn, Iee-Ki
    • Aerospace Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.8-12
    • /
    • 2009
  • It is absolutely necessary to measure the inlet pressure and temperature of a turbine or a compressor to evaluate the performance of it. And to measure the representative-averaged pressure and temperature of turbine inlet flow, rake is normally used. Rake has several elements for temperature and pressure and several rakes are installed at the inlet to average the radial and circumferential distribution of inlet flow. However the rakes cause unexpected losses and flow distortion at the turbine inlet which make the measured rake data different from true inlet value. So the evaluation of a turbine or a compressor performance becomes not accurate. This study suggest a correlation method which measure the loss by inlet rake and incorporates it in evaluating the performance of turbomachinery.

  • PDF

Inlet Distortion Test of Gas Turbine Engine (가스터빈 엔진의 입구 유동 왜곡 시험)

  • Lee, Jin-Kun;Lee, Kyung-Jae
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.04a
    • /
    • pp.339-345
    • /
    • 2007
  • Inlet distortion test was performed at Korea Aerospace Research Institute in order to evaluate the degradation of engine performance under the distorted inlet condition. In this paper, only the inlet pressure distortion was taken into consideration. During the development process of the inlet distortion test technique, variable distortion screen was designed and evaluated under various test conditions to establish the experimental database of distortion for engine test. The result of inlet distortion test for engine shows that the operating point was changed toward the worse direction and the degradation of engine performance by inlet distortion was verified.

  • PDF

Flow and Heat Transfer Characteristics of a Circular Cylinder with the Periodic Inlet Velocity (주기적인 입구 속도 변동에 따른 원관 주위 유동 및 열전달 특성)

  • Ha, Ji Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.3
    • /
    • pp.27-32
    • /
    • 2019
  • In this study, the vorticity distribution and the temperature distribution change around a circular cylinder were compared and analyzed with time for constant inlet velocity and periodic inlet velocity. Also, the frequency characteristics of the flow were analyzed by analyzing the time variation of lift and drag and their PSD(power spectral density). In the case of constant inlet velocity, the well known Karman vorticity distribution was shown, and vortices were alternately generated at the upper and lower sides of the circular cylinder. In case of periodic inlet velocity, it was observed that vortex occurred simultaneously in the upper and lower sides of the circular cylinder. In both cases, it was confirmed that the time dependent temperature distribution changes almost the same behavior as the vorticity distribution. For the constant inlet velocity, the vortex flow frequency is 31.15 Hz, and for the periodic inlet velocity, the vortex flow frequency is equal to the preriodic inlet velocity at 15.57 Hz. The mean surface Nusselt number was 99.6 for the constant inlet velocity and 110.7 for the periodic inlet velocity, which showed 11.1% increase in surface heat transfer.

Performance Analysis for Turbo Blower According to Inlet-Vane Angles (입구베인 각도에 따른 터보블로어 성능특성 연구)

  • Jang, Choon-Man;Lim, Soo-Jung;Yang, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.3
    • /
    • pp.301-307
    • /
    • 2011
  • Turbo blowers are mainly used in refuse collection systems. We discuss blower performance in relation to the angle of the inlet vane installed at the upstream of the blower. The flow characteristics of the components are analyzed by three-dimensional Navier-Stokes analysis and compared to experimental results. A two-stage serially connected turbo blower is introduced to analyze the performance experimentally. Throughout the experimental measurements and the numerical simulation, the distorted inlet velocity generated in the small vane angle reduces the performance of the blower, because of the local leading-edge separation and the resulting non-uniform blade loading. We also perform a detailed flow analysis using the results obtained in the numerical simulation.

Development of a Polytropic Index-Based Reheat Gas Turbine Inlet Temperature Calculation Algorithm (폴리트로픽 지수 기반의 재열 가스터빈 입구온도 산출 알고리즘 개발)

  • Young-Bok Han;Sung-Ho Kim;Byon-Gon Kim
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.483-494
    • /
    • 2023
  • Recently, gas turbine generators are widely used for frequency control of power systems. Although the inlet temperature of a gas turbine is a key factor related to the performance and lifespan of the device, the inlet temperature is not measured directly for reasons such as the turbine structure and operating environment. In particular, the inlet temperature of the reheating gas turbine is very important for stable operation management, but field workers are experiencing a lot of difficulties because the manufacturer does not provide information on the calculation formula. Therefore, in this study, we propose a method for estimating the inlet temperature of a gas turbine using a machine learning-based linear regression analysis method based on a polytropic process equation. In addition, by proposing an inlet temperature calculation algorithm through the usefulness analysis and verification of the inlet temperature calculation model obtained through linear regression analysis, it is intended to help to improve the level of reheat gas turbine combustion tuning technology.

A Study on The Characteristics of The Inlet Boundary Condition of a Supersonic Turbine Cascade (초음속 터빈 캐스케이드 입구 경계조건의 특성에 관한 연구)

  • 신봉근;성영식;정수인;김귀순;이은석
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.99-103
    • /
    • 2003
  • An analysis of the flow within supersonic turbine cascades is necessary to design and manufacture turbo-pump system. Because of the differences between the specified inlet boundary value and the computed inlet value caused by the far field inlet boundary condition, the computations at desired inlet conditions can not be achieved. So, this paper studied the problem occurred when far field inlet conditions were specified as inlet boundary conditions. And the numerical analyses using Fine Turbo, CFD Program, has been performed and compared with those of experiments when a converging-diverging nozzle or a linear nozzle was located in front of cascades instead of the far field inlet condition.

  • PDF

Study on Performance of Vertical-axis Tidal Turbines Applied to the Discharged Channel of Power Plant (조류발전용 수직축 터빈의 방수로 설치에 따른 성능에 관한 연구)

  • Lee, Jeong-Ki;Hyun, Beom-Soo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.18 no.4
    • /
    • pp.274-281
    • /
    • 2015
  • Thermal and nuclear power plants on shore commonly use the sea water for cooling facility. Discharged cooling water has the high kinematic energy potential due to amount of water flux. Numerical analysis was made to find the suitable combinations between the arrangement of tidal turbines and the overall dimensions of the discharged channel. Several parameters such as the turbine diameter to inlet size, and the axial distance to turbine size were investigated. Power coefficients for various test conditions were also compared to see the effect of inlet configurations such as single inlet and dual inlet. For the single inlet, the mean power coefficient appeared to be gradually decreased with increasing distance, and the maximum power was obtained when the turbine diameter was same as the inlet diameter. For the dual inlet, the tendency was similar so that the better result when the turbine diameter was same as the inlet diameter. It is expected that the present methodology can be extensively utilized to harness the high kinetic energy flow of the discharge channel of power plant.