• Title/Summary/Keyword: 임플란트 환자

Search Result 497, Processing Time 0.022 seconds

Analysis of temperature changes and sterilization effect of diode laser for the treatment of peri-implantitis by wavelength and irradiation time (임플란트 주위염 치료용 diode laser의 파장 및 조사시간에 따른 온도 변화와 살균효과 분석)

  • Seol, Jeong-Hwan;Lee, Jun Jae;Kum, Kee-Yeon;Lee, Jong-Ho;Lim, Young-Joon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.3
    • /
    • pp.178-188
    • /
    • 2017
  • Purpose: We compared the effects of newly developed diode laser (Bison 808 nm Diode laser) on the treatment of peri-implantitis with conventional products (Picasso 810 nm Diode laser) by comparing the surface temperature of titanium disc and bacterial sterilization according to laser power. Materials and Methods: The titanium disc was irradiated for 60 seconds and 1 - 2.5 W using diode laser 808 nm and 810 nm. The surface temperature of the titanium disc was measured using a temperature measurement module and a temperature measurement program. In addition, in order to investigate the sterilizing effect according to the laser power, 808 nm laser was irradiated after application of bacteria to sandblasted large-grit acid-etched (SLA) and resorbable blast media (RBM) coated titanium discs. The irradiated disks were examined with scanning electron microscopy. Results: Both 808 nm and 810 nm lasers increased disk surface temperature as the power increased. When the 810 nm was irradiated under all conditions, the initial temperature rise rate, the descending rate, and the temperature change before and after was higher than that of 808 nm. Disk surface changes were not observed on both lasers at all conditions. Bacteria were irradiated with 808 nm, and the bactericidal effect was increased as the power increased. Conclusion: When applying these diode lasers to the treatment of peri-implantitis, 808 nm which have a bactericidal effect with less temperature fluctuation in the same power conditions would be considered safer. However, in order to apply a laser treatment in the dental clinical field, various safety and reliability should be secured.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption (임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료)

  • Choi, Yu-Sung
    • The Journal of the Korean dental association
    • /
    • v.50 no.3
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

Implant supported prosthesis with high performance polymers using a double scanning method (Double Scanning에 의한 고성능 중합체를 이용한 임플란트 지지 고정성 보철물 수복 증례)

  • Kang, Kyeong-Hwan;Park, Jin-Hong;Lee, Jeong-Yol;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.3
    • /
    • pp.305-310
    • /
    • 2017
  • Nowadays, the development of dental scanner and CAD/CAM technology can facilitate the fabrication of hybrid prosthesis. Double scanning technique, scanning a trial prosthesis and master model, made it possible to realize virtual design and simplify the laboratory work. Instead of using the metal or zirconia framework with composite, ceramic or denture tooth, the new high performance polymer Polyetherketoneketone (Pekkton, Cendres+$M{\acute{e}}taux$, Biel, Switzerland) as a framework with Polymethyl methacrylate (PMMA) veneering teeth (Visio-lign, Bredent, Senden, Germany) was used in this case. This case report showed an acceptable treatment outcome and satisfaction of patient using Pekkton and Visio-lign. However, long term clinical evaluation is needed.

A retrospective study of the dental implants placed in the controlled diabetes mellitus patients (조절되는 당뇨환자에게 식립된 치과 임플란트의 생존율에 대한 후향적 연구)

  • Kim, Young-Hee;Um, Yoo-Jung;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyu-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.39 no.3
    • /
    • pp.311-320
    • /
    • 2009
  • Purpose: The aim of the present study was to analyze 7-year cumulative survival rate (CSR, %) of dental implants in the controlled diabetic patients and to evaluate the influence of the position, diameter and length of fixture, bone quality, age, gender and the method of maxillary sinus elevation on the survival rate. Methods: The data of 342 placed implants in the 104 diabetic patients collected between 1995 and 2007 at the Department of Periodontology in Yonsei University Hospital were analyzed. Results: Seven-year CSR of the 342 dental implants in the 104 controlled diabetic patients was 96.5%. The survival rates of the placed implants according the position have no statistically significant difference. The survival rates according to the length or diameter of the fixtures have no statistically significant difference. The survival rates according to the bone quality were 100% (Type I), 97.1% (Type II), 97.7% (Type III) and 85.7%(Type IV). The difference between the survival rate of Type I, II and III and that of Type IV was statistically significant. The survival rates according to patient gender were 96.8% (male), 95.5% (female). The survival rates according to patient age were 100% (${\leq}59$), 93.8% (${\geq}60$). The survival rates according to the method of sinus elevation in the maxillary posterior area were 96.8% (without sinus elevation), 92.9% (lateral approach) and 89.8% (crestal approach). Conclusions: Dental implants can be used successfully in the controlled diabetic patients. In case of upper posterior region which has poor bone density and older patients, the implant treatment should be more properly planed, executed, and followed-up.

RADIOGRAPHIC EVALUATION OF BONE CHANCE AROUND OSSEOINTEGRATED IMPLANTS IN PARTIALLY EDENTULOUS JAWS WITH FIXED TISSUE-INTEGRATED PROSTHESES (부분무치악 환자에서 기능하중노출이 골유착성 임플란트 주위의 치조골 소실에 미치는 영향에 관한 방사선학적 연구)

  • Yang, Soon-Bong;Han, Dong-Hoo;Yang, Ja-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.1
    • /
    • pp.70-84
    • /
    • 1996
  • This paper reports marginal bone loss around osseointegrated implants after loading in partially edentulous patients in dental hospital, Yonsei University. Two types of implants($Br{\aa}nemark^{TM},\;IMZ^{TM}$) were used. Through the digital measurement on periapical radiograph around 37 implants in human subjects, marginal bone loss was observed for 24 months after delivery of prostheses. The results were as follows; 1. According to experimental periods marginal bone loss in total implants was 1.775 mm at 12 months, 1.921 mm at 24 months after delivery of prostheses(p<0.05). 2. Marginal bone loss in the $Br{\aa}nemark$ implants was 1.831 mm at 12 months, 1.833 mm at 24 months after delivery of prostheses(p<0.05). 3. Marginal bone loss in the IMZ implants was 1.578 mm at 12 months, 2.907 mm at 23 months after delivery of prostheses(p<0.05). 4. During the first year after loading, the IMZ implants showed less marginal bone loss than the $Br{\aa}nemark$ implants but, during the next the $Br{\aa}nemark$ implants showed less than the IMZ implants(p>0.05). These results indicate that marginal bone loss around osseointegrated implants occurs within the first 12 months after delivery of prostheses and stabilizes thereafter, so it is necessary to be careful of using dental implants for the first year after delivery of prostheses.

  • PDF

INTRAVENOUS SEDATION OF CEREBRAL PALSY PATIENT FOR DENTAL IMPLANT CT TAKING -A CASE REPORT (정신지체가 동반된 뇌성마비 환자의 임플란트 치료를 위한 CT 촬영 시 진정법 시행 -증례보고-)

  • Seo, Kwang-Suk;Lee, Ju-Hwan;Shin, Teo-Jeon;Yi, Young-Eun;Kim, Hyun-Jeong;Yum, Kwang-Won;Kim, Myung-Jin
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.4 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • A 33-years-old female pateint with cerebral palsy showing spastic quardriplegia and severe mental retardation was scheduled for dental implant restorations. Before implant surgery we had to take implant CT. But, because of her involuntary motion and communication difficulty, sedation was needed in order to take CT. After 8 hour NPO, propofol infusion sedation with TCI (target controlled infusion) system was administered. The propofol blood concentration of the patient was maintained 2-3 ${\mu}$/ml to keep deep sedation to prevent uncontolled movement. During sedation, we monitored ECG, pulse oximetry, blood pressure, capnometry for patient safety. Oxygen was administered via nasal prong for preventing hypoxemia and to keep airway during sedation some bands were applied to lift mandible. Total duration was 20 minutes for taking CT, and she was discharged from hospital after 30 minute rest without complication.

  • PDF

EVALUATION OF MAXILLARY SINUS USING CONE-BEAM CT IN PATIENTS SCHEDULED FOR DENTAL IMPLANT IN MAXILLARY POSTERIOR AREA (상악 구치부 임플란트 치료를 위해 내원한 환자들에서 Cone-beam CT를 이용한 상악동의 평가)

  • Cheong, Chang-Shin;Cho, Bong-Hae;Hwang, Dae-Seok;Jung, Yeon-Hwa;Naa, Kyeong-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.1
    • /
    • pp.21-25
    • /
    • 2009
  • Objective: The purpose of this study is to determine the prevalence of sinus disease and abnormalities in patients scheduled for dental implant in maxillary posterior area using cone beam CT. Patients and Method: One hundred five maxillary sinuses in eighty-seven patients who underwent cone beam CT for dental implant in maxillary posterior area were included. Any patients who had previous history of sinus operations were not included. The sinus abnormalities were classified as follows ; normal (membrane thickness <2 mm), mucosal thickening (membrane thickness ${\geq}$ 2 mm and < 6 mm), partial opacification (membrane thickness > 6 mm but not full), full opacification and mucous retention cyst. The relationship between the remaining bone height, sinus symptoms and maxillary sinus abnormality was statistically surveyed. Results: Of 105 maxillary sinuses in 87 patients, 80 (76%) maxillary sinuses showed abnormalities ; 4 of 4 symptomatic patients and 76 of 101 asymptomatic patients. Mucosal thickening was the most common sinus abnormality. Only 3 (4%) of 80 maxillary sinus abnormalities were caused by the odontogenic origin. The prevalence of maxillary sinus abnormalities was higher in the symptomatic group than asymptomatic one (p<0.05). Conclusion: Maxillary sinus abnormalities were very common in the patients who were planning implantation in maxillary posterior areas. This result supports that thorough evaluation for maxillary sinus is recommended when implant treatment is planned for those areas.

Comparative Study of Sterilization by Gamma-ray and Electron-Beam (감마선, 전자선에 의한 멸균 비교분석)

  • Jeong, Kyeonghwan;Park, Changhee
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.537-543
    • /
    • 2020
  • The elderly population in the modern society is growing rapidly due to advance medical technology and minimally invasive surgery. Therefore, as the tendency to use medical device is increasing, pathogenic infection is a concern. Therefore, the first aim of modern medicine is infection prevention in medical place. Recently, patient implants are increasing using 3D printing. Hydroxyapatite is used as a representative material. And, there haven't had currently absorbed dose standard for sterilization of hydroxyapatite discs. Escherichia coli and Streptococcus mutans contaminated on the surface of hydroxyapatite discs were irradiated at each absorbed dose of 0, 0.5, 1.0, 3.0, 5.0 kGy using Gamma-ray of cobalt and Electron-beam of linear accelerator. Then, the number of bacteria was measured in the sample by the decimal dilution method. After sterilization, a non-parametric testing method was performed to compare the survival of Escherichia coli and Streptococcus mutans. As a result, Escherichia coli was sterilized at 1 kGy or more and Streptococcus mutans at 3 kGy or more on absorbed dose. It is considered possible to perform sterilization at a lower value than the recommended absorbed dose of radiation sterilization.

Rehabilitation of a patient with crossed occlusion using mandibular implant-supported fixed and maxillary Kennedy class IV removable dental prostheses: A case report (엇갈린 교합 환자의 임플란트 지지 고정성 보철물과 Kennedy class IV 가철성 국소의치를 이용한 수복 증례)

  • Kang, Seok-Hyung;Han, Jung-Suk;Kim, Sung-Hun;Yoon, Hyung-In;Yeo, In-Sung
    • The Journal of the Korean dental association
    • /
    • v.55 no.12
    • /
    • pp.842-849
    • /
    • 2017
  • The term, 'crossed occlusion' implies clinical situation in which the residual teeth in one arch have no contact with those in the antagonistic arch, resulting in the collapse of occlusal vertical dimension. The treatment goal of this pathologic condition is restoration of the collapsed vertical dimension and stabilization of abnormal mandibular position. Previously, konus removable prostheses or tooth supported overdentures were suggested to solve crossed occlusion. Nowadays, dental implants have been used for definitive support to solve this problem. In this case report, a 65 years old female patient had a crossed occlusion, in which the maxillary posterior residual teeth and mandibular anterior residual teeth cross. Interim removable and fixed dental prostheses were used to confirm the proper vertical and horizontal jaw relation. After that, the mandibular posterior edentulous region was restored with implant-supported fixed dental prostheses. Computer tomography guided implant surgery was performed according to the concept of the restoration-driven implant placement. The maxillary anterior edentulous region was restored with Kennedy class IV removable prosthesis, considering the patient's economic status. The patient's jaw position and prostheses have been well maintained at the follow-up after 6 months of definitive restoration. The antero-posterior crossed occlusion problems appeared to be effectively solved with the combination of removable in one arch and implant-supported fixed prostheses in the other.

  • PDF