• Title/Summary/Keyword: 임플란트 환자

Search Result 497, Processing Time 0.019 seconds

Influence of crown-to-implant ratio of short vs long implants on implant stability and marginal bone loss in the mandibular single molar implant (하악 구치 단일임플란트 수복에서 임플란트 길이에 따른 치관-임플란트 비율이 임플란트안정성 및 변연골소실에 주는 영향)

  • Baek, Yeon-Wha;Kim, Bongju;Kim, Myung-Joo;Kwon, Ho-Beom;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.280-289
    • /
    • 2018
  • Purpose: The purpose of this randomized clinical trial is to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and peri-implant marginal bone loss (MBL). Materials and Methods: 46 patients with single tooth missing in the posterior molar region of the mandible were included in this study. 19 implants (CMI IS-III $active^{(R)}$ long implant) of 5.0 mm diameter and 10 mm length were installed for the control group, while 27 implants (CMI IS-III $active^{(R)}$ short implant) of 5.5 mm diameter and 6.6, 7.3 or 8.5 mm length were placed for the experimental group. Each implant was inserted and immediately loaded using the digitally pre-fabricated surgical template and provisional restoration. The CAD-CAM monolithic zirconia crown was fabricated at 3 months after the surgery as a definitive restoration. The ISQ value and the MBL was measured at 48 weeks after the surgery. The correlation between the C/I ratio, MBL, and secondary implant stability was analyzed. Results: Successful results in terms of ISQ and MBL were achieved with both groups. There was no significant difference between the groups in terms of ISQ values and MBL at 48 weeks after the surgery (P > 0.05). No significant correlation was found between the C/I ratio and secondary stability as well as the C/I ratio and the MBL (P > 0.05). Conclusion: The influence of C/I ratio in both groups was not shown on the stability nor the marginal bone loss in implants supporting single crown of the mandible. Short implant could be a preferable alternative option in the reduced bone height mandible under the limited condition despite its higher C/I ratio.

Accuracy assessment of implant placement using a stereolithographic surgical guide made with digital scan (디지털 스캔을 이용하여 제작된 임플란트 수술가이드의 정확도)

  • Jeong, Seung-Mi;Fang, Jeong-Whan;Hwang, Chan-Hyeon;Kang, Se-Ha;Choi, Byung-Ho;Fang, Yiqin;Jeon, Hyongtae;An, Sunghun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.111-119
    • /
    • 2015
  • Purpose: The objective of this study was to evaluate the accuracy of a stereolithographic surgical guide that was made with information from intraoral digital impressions and cone beam CT (CBCT). Materials and methods: Six sets of resin maxilla and mandible models with missing teeth were used in this study. Intraoral digital impressions were made. The virtual models provided by these intraoral digital impressions and by the CBCT scan images of the resin models were used to create a surgical guide. Implant surgery was performed on the resin models using the surgical guide. After implant placement, the models were subjected to another CBCT scan to compare the planned and actual implant positions. Deviations in position, depth and axis between the planned and actual positions were measured for each implant. Results: The mean deviation of the insertion point and angulation were 0.28 mm and $0.26^{\circ}$, apex point were 0.11 mm and 0.14 mm respectively. The implants were situated at a mean of 0.44 mm coronal to the planned vertical position. Conclusion: This study demonstrates that stereolithographic surgical guides created without the use of impressions and stone models show promising accuracy in implant placement.

Initial Changes of Implant Stability from Installation during Early Bone Healing (임플란트 식립 후 초기 안정성의 변화)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.272-279
    • /
    • 2013
  • The concept of implant stability was basically originated from the relative condition of bone-implant interface and has some meanings for evaluation of that interface. In addtion, it has been used for the investigation of initial bone healing process after fixture installation because a degree of micromotion around interface can affect unfavorable clinical results. The purpose of this study is to investigate the mode of initial bone healing from fixture installation through prospective trial. Thirty fixtures were consecutively installed in mandibles of 26 patients with single tooth loss area and then healing abutment were secured for one-stage surgery meothod. Resonance frequency analysis was performed with one week interval during 12 weeks and periapical radiographs were taken at each month. Although marginal bone level change was not shown through observation period (P>0.05), statistical difference of implant stability was shown through 4 and 6 week (P<0.05) and was not shown after 6 week (P>0.05) according to the bone quality. Initial bone healing process is a successive process of bone resorption and favorable bone healing result might be postulated at 4 week interval after installation through RFA.

A Clinical Study on the Relationship between Dental Implant and Systemic Disease (치과 임플란트와 전신질환과의 연관성에 관한 임상적 고찰)

  • Yang-Keum Han;Mi-Sook Yoon;Han-Hong Kim
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.25-35
    • /
    • 2023
  • Background: In order to emphasize the importance of clinical dental hygienists-led dental hygiene management processes for those with systemic diseases, we tried to identify systemic diseases affecting dental implants based on clinical data. Methods: In order to identify systemic diseases affecting dental implants, literature review was conducted from March 1 to May 31, 2023, and the search period was for research papers published in domestic and foreign academic journals from January 2000 to December 2020. Domestic databases used for search use RISS, Nuri Media(DBpia), and Korea Academic Information (http://www.papersearch.net ; KISS), while overseas databases searched Pubmed for dental implant failures, implants, systemic diseases, and Dental implant and system disease. Results: The cumulative survival rate of implants averaged 94.3 percent and the failure rate was 5.7 percent. Clinical analysis of systemic diseases related to implants accounted for the highest frequency with 13 (100.0%), followed by 8 (61.5%) studies on high blood pressure and smoking, 7 (53.8%) cardiovascular diseases, and 5 (38.5%). In addition, liver disease, thyroid abnormalities, blood abnormalities, organ transplants and infectious diseases were confirmed. Conclusion: Since unregulated systemic diseases are a risk factor for implant failure, clinical dental hygienists should continue to maintain healthy oral conditions by sharing information with patients during periodic preventive dental hygiene management processes such as dental hygiene assessment.

Implant hybrid prosthetic treatment in Down syndrome patient: a case report (다운증후군 환자에서 임플란트 하이브리드 보철 치료 증례)

  • Kim, Mi-Gyeong;Kim, Jae-Hoon;Lee, Ha-Rim;Jang, Eun-Sun;Kim, Hee-Jung;Lee, Gyeong-Je
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.225-231
    • /
    • 2018
  • Down syndrome patients generally have poor oral hygiene due to lack of awareness and ability to perform oral care, and there is a high risk of tooth loss. Also, they are characterized by small and irregular teeth and oligodontia, which makes it difficult to do prosthetic treatment. This article reports a case of implant hybrid prosthesis treatment of maxillary edentulous area in Down syndrome patient. The external shape of the final prosthesis was determined by using the mandibular artificial teeth to reflect the oligodontia of the mandible and the pontic areas were adjusted to facilitate oral hygiene care. As a result, aesthetically and functionally satisfactory results were obtained.

Overdentures of the patient with Parkinson's disease: A case report (파킨슨 병을 가진 환자의 상악 마그네틱 피개의치 및 하악 임플란트 피개의치 수복 증례)

  • Min, Byung-Kwee;Shin, Eun-Jung;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Yun, Kwi-Dug;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.4
    • /
    • pp.352-358
    • /
    • 2015
  • The retention of complete dentures in patients with Parkinson's disease is often poor due to their constant dislodgement by involuntary movements of the tongue and lips. Furthermore, insertion of the overdenture is expected to be difficult due to their limited voluntary movements. This case is about the bimaxillary overdenture restoration where its retention and stability are improved, using magnetic attachment of remained roots of maxilla and two implant $Locator^{(R)}$ attachments of mandible in patients with Parkinson's disease. This report describes the fabrication of this functionally improved prosthesis.

Digital duplication of provisional prosthesis to fabricate definitive prosthesis for full mouth rehabilitation using double scan technique (잠정수복물의 최종수복물로의 디지털 복제를 통한 완전구강 회복 증례: Double scan technique)

  • Hong, Young-Tack;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Using computer-aided design and manufacturing technique improve quality of treatment in many aspect. This case reports the complete mouth rehabilitation of a patient with amelogenesis imperfecta utilizing digital technology. Clinical examination revealed loss of mastication due to insufficient occlusal stop, missing teeth, interdental spacing due to microdontia, insufficient overbite, and etc. Full veneer crowns for teeth were selected, followed by a fixed partial denture and implant placement was done using CAD-CAM guide template with bone graft for partially edentulous space. Definitive restorations were duplicated by double scanning provisional restorations and successfully delivered to the patient. These full mouth rehabilitation procedures resulted in satisfactory outcomes for the patient functionally and aesthetically.

전치부 임플란트의 심미적 수복

  • Lee, Seo-Yeong;Ryu, Jae-Jun
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • 오늘날 단일치 임플란트의 식립은 현재 시행되고 있는 가장 일반적인 임플란트 술식 중 하나이며, 상악 전치부는 이중 가장 흔하게 시행되는 식립 부위 중하나이다. 그럼에도 불구하고 상악 전치부 단일 상실치에 대한 치료 계획은 구강 내 다른 어떤 부위보다 복잡하며 고도로 심미성을 요구하는 부위로서 아무리 경험이 많고 기술이 뛰어난 치과의사라 할지라도 시술할 때마다 큰 도전으로 여겨지는 경우가 대부분일 것이다. 상악 전치부에서 임플란트 보철의 심미적 성공을 이루기 위해서는 모든 구성 요소 하나하나에서 심미적 결과를 이룩하여야 하고 이 결과들이 완벽하게 조화를 이루게 하여야 하며 이는 결코 쉬운 일이 아닐 것이다. 시술 시 교과서의 그림처럼, 모형에 식립해 본 것처럼 쉽게 되지 않는 것은 물론 구강 내 환경이 모형과 다를 리 만무한 것이 당연한 첫 번째 이유이며 뿐만 아니라 환자 대부분의 경우 모형처럼 완벽한 경 연조직이 갖추어진 상태에서 치아만 상실된 경우는 거의 찾아볼 수 없기 때문인 이유도 크다. 즉, 원하는 위치에 식립을 하고 장기간의 심미적 유지를 위해서는 경 연조직에 대한 처치가 필수적인 경우가 대부분이라는 이야기이다. 이를 간과하고 식립한 경우 추후 심각한 bone의 resorption, 그에 따르는 gingiva의 끔찍한 recession, 용납할 수 없는 비심미적 보철물의 제작은 불을 보듯 뻔한 결과가 될 것이다. 따라서 상악 전치부 식립 치료계획 시 치과의사는 성공적 결과에 영향을 미칠 수 있는 모든 요소에 촉각을 곤두세우고 이들의 완벽한 처치에 최선을 다 해야할 것이다.

  • PDF

Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture (상악의 소수 잔존치와 실패한 하악의 임플란트 오버덴처의 재수복 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.246-252
    • /
    • 2016
  • Double crown prostheses can be used in patients who have a few remaining teeth and poor periodontal condition because of secondary splinting of abutments, vertical loading, decrease of the length of lever arm due to fulcrum line located on margin of inner and outer crown. Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth and implant overdenture using a small number of implants have been reported. In this case, there were a few remaining teeth with a very poor periodontal condition in maxilla, and there were a failed implant with severe alveolar bone resorption and shrinkage in the mandible. The main objective of this report is to introduce our case because a double crown partial denture showed satisfactory results in functional and esthetical aspects during more than one-year follow-up period.