• Title/Summary/Keyword: 임플란트 피개의치

Search Result 87, Processing Time 0.019 seconds

Full mouth rehabilitation of fully edentulous patient with implant-supported fixed prosthesis preceding bone graft: A case report (전악 무치악 환자에서 골이식술을 선행한 임플란트 고정성 보철 수복 증례)

  • An, Ju-Nam;Lee, Jung-Jin;Seo, Jae-Min;Kim, Kyoung-A
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.77-87
    • /
    • 2018
  • Prosthetic treatment using implants in fully edentulous patients includes implant-supported fixed prosthesis, implant hybrid prosthesis, implant retained- or supported-over-denture and implant supported fixed prosthesis has advantages such as psychological stability, pronunciation. If an implant supported fixed prosthesis is planned, the implants should be placed in consideration of pronunciation, esthetics, and oral hygiene. For this, clinical and radiological diagnosis is indispensable. When placing the prosthetic driven implant at the site determined from the diagnosis, a sufficient amount of alveolar bone and soft tissue support are required. If these requirements found to be insufficient, a wide range of bone grafting should be performed in advance. In this case, a fully edentulous patient with severe alveolar bone resorption due to periodontal disease was treated with a full mouth rehabilitation using implant-supported fixed prosthesis preceding maxillary sinus graft and alveolar bone augmentation. We report this patient were satisfied with esthetic and function.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.3
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

Early loading using tempo denture with solitary attachment system, implant supported overdenture with prefabricated bar attachment system on Mandibular edentulous patient: A case report (하악 완전 무치악 환자에서 solitary attachment를 연결한 임시 보철물로 조기 부하를 가한 후, 조립식 바를 이용한 최종 임플란트 지지 피개의치 제작증례)

  • Park, Do-Hyeon;Lee, So-Hyoun;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of the Korean dental association
    • /
    • v.54 no.1
    • /
    • pp.39-48
    • /
    • 2016
  • SFI-bar is prefabricated bar system and can be assembled at chairside without soldering or welding, thus reducing bone loss, costs and time. A 53-year-old male patient, who had severely absorbed mandible, hoped to wear a stable mandiblular denture. Four implants were placed in the extraction site of canine and 1st molar. Early loaded temporary denture with solitary type attachment was delivered 3 weeks after surgery. 3 month later, SFI-bar was connected and adjusted at chairside. Then, implant overdenture using SFI-bar was delivered. This case report showed that a satisfactory clinical result was achieved by 4-implant-supported overdenture using the SFI-Bar system in a mandibular edentulous patient.

  • PDF

Using implants for worn dentition with the altered vertical dimension of occlusion based on shortened dental arch concept: a case report (과도한 마모를 보이는 환자에서, 임플란트를 활용해 수직 고경을 증가시키며 shortened dental arch 개념을 적용한 보철 수복 증례)

  • Lee, Jae Hyun;Kim, Tae Su;Lee, Chul Won;Lee, Won Sup;Lee, Su Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.49-56
    • /
    • 2016
  • Excessive occlusal wear can result in unacceptable damage to the residual teeth structure, anterior guidance and masticatory function. An 86-year-old man presented with worn dentition and anterior deep bite due to loss of the posterior support. Two implants covered by Korean national health insurance, fixed partial denture and direct composite resin were used to restore the dentition, instead of removable prosthesis. The occlusal vertical dimension was increased by 2 mm in the premolar area and shortened dental arch concept was applied. This treatment was a less expensive alternative to full-mouth rehabilitation with positive esthetic and functional outcomes after 7 months of follow-up.

Full mouth rehabilitation in a patient with loss of vertical dimension caused by severe tooth loss: a case report (광범위한 치질 상실로 인해 수직 고경 감소 환자의 전악 수복 증례)

  • Yun, Ah-Young;Shim, Hye-Won;An, Jin-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.42-47
    • /
    • 2014
  • Decrease of occlusal vertical dimension (OVD) due to loss of teeth structure and destruction of the occlusal plane by severely worn dentition may cause cross bite or temporomandibular joint disorder by following change of facial feature or the loss of anterior guidance. Full mouth rehabilitation via an increase of the OVD can be considered to avoid this problem and proper evaluation of patient's OVD is essential. An 80 year old male visited for overall prosthodontic treatment, cross bite due to continuous wear and following decrease of the OVD were observed. We analyzed the existing occlusal relationship using the diagnostic cast, the radiographic evaluation and clinical test, and then proper increase of OVD was selected. The new OVD on diagnostic wax up was placed by the temporary restoration. After 3 months of observation period, final restoration with fixed partial dentures and implant overdenture were made. Throughout the follow-up period of 8 months, the aesthetic and functional improvement can be obtained.

A Study on the Retentive Force of Stud Attachments for Implant Overdenture (임플란트 피개의치를 위한 개별유지형 어태치먼트의 유지력에 관한 연구)

  • Song, Eun-Ju;Bae, Eun-Bin;Choi, Jae-Won;Bae, Ji-Hyeon;Kim, Ji-Young;Lee, So-Hyoun
    • Journal of dental hygiene science
    • /
    • v.16 no.1
    • /
    • pp.93-100
    • /
    • 2016
  • The purpose of this study was to compare the changes of retentive force in different stud attachment systems for implant retained overdenture. Two commercially available attachments with different retentive forces were investigated: Kerator (pink, blue, red) and O-ring (orange, red). Two implant fixtures were vertically embedded in base mountings. Five pairs of each attachment were evaluated. A universal testing machine was used to evaluate the retentive force of two attachments during wear simulation. Surface characteristics of each attachment system were evaluated with scanning electron microscopy. Five pairs of each attachment were evaluated. Kerator pink showed the highest initial retention. After 2,500 cycles of wear-simulation, Kerator pink noted the largest decrease in retention. According to results of surface analysis, Worn surfaces were obtained in matrices and patrices. Heavy wears were observed in matrices. After 2 year-wear simulation, most attachments exhibited retention loss. Attachments using different kind of material exhibited dissimilar surface alterations.

Comparison of the retentive characteristics of two additional attachment used with an implant bar attachment (임플란트 bar 어태치먼트에 사용하는 두 가지 부가적인 유지장 치의 유지력 특성 비교)

  • Choi, Jae-Won;Chae, Sung-Ki;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.173-180
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the retentive characteristics of the additional attachments used with implant bar attachment under repeated insertion/removal cycles. Materials and methods: The newly developed attachment and the commercially available attachment were investigated: ADD-Lock (AL), Locator blue (LB). Two fixtures were placed parallel to each other on the custom lower mounting, and patrix of each attachment was fixed to the fixture. Also, the matrix of each attachment was placed on the opposing upper mounting. A universal testing machine was used to measure the retentive force during initial, 100, 250, 500, 1000, 2000, and 2500 repeated insertion/removal cycles. Wear and deformation of the attachment s were observed by scanning electron microscopy (SEM). Mann-Whitney U test (α=.05) and wilcoxon signed-rank test (α=.05) were performed to compare retentive force between each group and before and after 2500 repeated insertion/removal cycles. Results: In terms of initial retentive force and retentive force after 2500 repeated insertion/removal cycles, the AL group (15.24 ± 1.46 N and 9.74 ± 1.16 N) showed significantly smaller values than the LB group (43.53 ± 12.39 N and 22.99 ± 4.77 N) (P<.05). Also, in the loss of retentive force, the AL group (5.50 ± 1.08 N, 36.08%) showed a smaller value than the LB group (20.54 ± 11.89 N, 47.19%) (P<.05). Based on SEM analysis, The AL group showed noticeable wear and deformation in the patrix and the LB group in the matrix. Conclusion: Locator showed a higher initial retentive force than newly developed attachment, while the loss of retentive force was also higher. Both additional attachments are considered to have sufficient retentive force after repeated insertion/removal cycles.