• 제목/요약/키워드: 임플란트 제거

검색결과 76건 처리시간 0.03초

치위생 용어 표준화를 위한 방안 연구 (A study for the standardization of dental hygiene terms)

  • 황지영;조민정;박영남;임순연;황수정;오상환
    • 한국치위생학회지
    • /
    • 제10권4호
    • /
    • pp.627-633
    • /
    • 2010
  • Objectives : The purpose of this study was to compare and analyse periodontal terminology of 16 dental hygiene textbooks including periodontology, dental prophylaxis for the standardization. Methods : 16 kinds of major publications were classified into the following criteria. - the standardization of translation, orthography, classification Results : 1. There are twelve cases, all told, of words with same origin used as different explanation and interpretation. Mucogingival Junction is most translated as '치은점막 경계' with high percentage of 53.8%, while Probe is translated as '치주낭 측정기' with 41.7% and Acquired Pellicle is translated as '획득피막' with 57.1%. In addition, Stippling is interpreted as '점몰' with high percentage of 70%, and Supine Position is interpreted as '수평자세' or '앙와위' with 33.3%. Yet, Pen Grasp is explained differently in all five books, whereas Modified Pen Grasp is explained as '변형 연필 잡기법' with 57.1%. The rest, Palm Thumb Grasp and Adaptation, have different interpretation in books, requiring unified interpretation of terms. 2. There are two cases of loanwords expressed according to orthography. Implant is expressed as '임플란트'(87.5%) and '임프란트'(12.5%). Scaling is expressed as '스켈링'(40.0%) and '스케일링'(60.0%). 3. There are four cases of same terms classified in a different way. Classification of 'Probing시 압력' and '치주인대섬유군' concurs only 50.0% in six books. '치석제거 시술자의 위치' is classified differently in all six books, while '정상치은 열구 깊이' concurred 45.5% in books. Conclusions : In conclusion, related academic majors and writers should provide cohesive explanation and interpretation of terms for unification of terminology in the field of periodontics as well as higher level of understanding and learning opportunities for students. Furthermore, description of all terms should be reviewed and analyzed comprehensively based on existing classification criteria in order to provide best standard explanation.

RBM 처리된 임플란트 표면의 인공치태 제거 효과 연구 (COMPARATIVE STUDY OF REMOVAL EFFECT ON ARTIFICIAL PLAQUE FROM RBM TREATED IMPLANT)

  • 박재완;국민석;박홍주;;최충호;홍석진;오희균
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제29권4호
    • /
    • pp.309-320
    • /
    • 2007
  • Purpose: This study was to evaluate the removal effect on artificial plaque from RBM treated implant surfaces that are exposed due to peri-implantitis. Materials and methods: Artificial plaque with Streptococcus mutans and acquired pellicle adhered to RBM treated implant discs. Study materials divided into one control and six test groups. In test groups, physical and chemical methods used to remove plaques. Prophyflex, Professional Mechanical Tooth Cleaning (PMTC) and interdental brush as mechanical treatments and 0.1% Chlorhexidine, Citric acid, HCl tetracycline as a chemical treatment were used. To analyses the study, disc weight was measured for remaining plaque quantities and SEM(Scanning Electronic Microscope) findings was taken for evaluation of surfaces. Results: 1. In weight changes, there was significant difference between each treatment group and the control group (p<0.05). Therefore all treatment methods using this study have good ability for remove plaques. 2. In weight changes, there was no significant difference between mechanical and chemical group, and there were no significant differences between each groups (p>0.05). 3. SEM findings after mechanical treatment disclosed as follows; Prophyflex group looked like sound implant surface, and there were some paste on implant surface at PMTC group, and there were some artificial plaque at interdental brush group. 4. SEM findings after chemical treatment disclosed as follows; there were some dark lesions which were supposed as the product from Streptococcus mutans at Chlorhexidine, Citric acid and HCl tetracycline groups. Conclusion: All six methods using in this study have good ability to remove artificial plaque on RBM treated implant. According to SEM findings, prophyflex is a superior method for removing of dental plaque among test groups.

가토의 대퇴골에 식립한 3종류의 수산화인회석 코팅 임플란트에 대한 제거회전력 비교 연구 (Comparative study of removal torque of 3 different hydroxyapatite coated implants in the femur of rabbits)

  • 김상수;이주형;유석현;이형주;문지원;박인숙;손동석
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제37권1호
    • /
    • pp.49-53
    • /
    • 2011
  • Introduction: This study compared the strength of osseointegration as determined by the resistance to reverse torque rotation of three different hydroxyapatite coated implants in the rabbit femur model. Materials and Methods: Three hydroxyapatite coated implants (HAPTITE), Tapered Screw-Vent (TSV) and BioTite-H - were used. A total of 40 implants were placed in the femur of 20 adult male rabbits. The animals were divided into two groups. In group A (n=10); one HAPTITE was placed into each right femur and one TSV was placed into each left femur. In group B (n=10); one HAPTITE was placed into each right femur and one BioTite-H was placed into each left femur. Five rabbits of each group were sacrificed at 4 and 8 weeks. The implants were removed by reverse torque rotation using a digital torque-measuring device. A total of 40 implants in 20 rabbits were used for the removal torque measurements. Results: In the Group A, 4 weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $70.7{\pm}31.6$ N cm and $28.9{\pm}15.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and TSV was $87.9{\pm}26.2$ N cm and $54.9{\pm}22.4$ N cm, respectively. In the Group B, 4 weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $58.0{\pm}29.6$ N cm and $37.7{\pm}14.1$ N cm, respectively. Eight weeks after implant placement, the mean removal torque for the HAPTITE and BioTite-H was $91.4{\pm}47.1$ N cm and $30.8{\pm}9.8$ N cm. HAPTITE showed a higher removal torque than the other implants. Conclusion: These results suggest that HAPTITE increases the strength of osseointegration significantly as determined by the resistance to reverse torque rotation.

TiCl4로 제조된 저비용 이산화티타늄 광촉매의 특성 및 경제성 평가 (Characteristic and Economic evaluation of low cost TiO2 photocatalyst made by TiCl4)

  • 김종규
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.197-197
    • /
    • 2019
  • 총인처리시설에서는 응집제를 주입하여 인이나 오염물질을 침전시켜 처리하고 있으며 PAC(poly aluminum chloride)나 $FeCl_3$, $Al_2(SO_4)_3$, 등 다양한 종류의 응집제가 사용되어지고 있다. 하지만 기존에 사용되어 지고 있는 알루미늄계열의 응집제는 처리수에 잔류이온이 존재하게 되어 인체에 축적돼 알츠하이머 병 등 신체질환을 유발할 수 있는 단점이 있다. 따라서 이러한 단점을 사전에 예방하기 위해 $TiCl_4$와 같은 티타늄계열 응집제에 대한 연구가 진행되고 있다. $TiCl_4$ 응집제는 인 제거에 효과적으로 적용할 수 있으며 수중에 잔류이온을 유발하지 않으며 Ti이온은 치과임플란트나 의료장비로 사용될 만큼 인체에 무해하다고 알려져 있다. 응집제 사용에 따라 생성된 응집슬러지의 처리방안에 있어서 기존 응집제의 경우 생성된 슬러지의 대부분은 하수슬러지 위탁처리업체를 통해 소각 및 매립, 재활용 되고 있으나, $TiCl_4$를 응집제로 사용할 경우 생성된 슬러지를 인발하여 건조 및 소성을 통해 이산화티타늄으로 재활용할 수 있어 슬러지를 친환경적으로 처리가 가능해 기존 슬러지 처리방안의 경제적, 환경적 부담을 줄일 수 있는 장점이 있다. 따라서 본 연구에서는 $TiCl_4$를 하수처리장 방류수에 주입하여 수중의 총인(T-P)을 처리한 후 생성된 슬러지를 인발하여 건조와 소성과정을 거쳐 이산화티타늄을 제조하였다. 방류수를 취수해 2.5mg/L의 초기 총인 농도를 가진 원수를 제조하였으며 제조된 원수에 $TiCl_4$를 0.6mL 주입하였을 때 99.93%의 총인제거효율을 얻을 수 있었다. 응집 실험 후 생성된 슬러지를 인발하여 건조 후 $300{\sim}1000^{\circ}C$의 각각 다른 온도조건에서 소성하여 이산화티타늄을 제조하였으며, SEM과 XRD를 통해 제조된 이산화티타늄의 표면특성과 결정성 분석을 실시하였다. 제조된 이산화티타늄은 $500{\sim}800^{\circ}C$에서는 아나타제, $900{\sim}1000^{\circ}C$에서는 루타일 결정구조가 나타났다. 또한, $TiCl_4$ 주입량에 따른 이산화티타늄의 최종 생산량과 제조 시 사용되는 건조로 및 소성로의 경제적 비용 등을 고려하여 이산화티타늄 1Ton을 제조하기 위해 필요한 단가를 산출하였다. 본 연구에서 제조된 이산화티타늄 1kg의 생산단가는 약 5,400원으로 나타났으며, 가장 많이 사용되는 P-25 광촉매 보다 저렴한 가격으로 제조 및 판매를 기대할 수 있다. 따라서 하수처리장에 적용 시 기존 응집제 보다 비싼 $TiCl_4$ 비용을 보완하고 친환경적인 슬러지 처리로 제조된 이산화티타늄의 유통 및 현장적용을 통해 경제적, 환경적으로 우수하다고 판단된다.

  • PDF

성견에서 교정적 고정원으로서의 티타늄 미니스크류에 대한 연구 (A Study on Titanium Miniscrew as Orthodontic Anchorage : An experimental investigation in dogs)

  • 윤병수;최병호;이원유;김경남;심형보;박진형
    • 대한치과교정학회지
    • /
    • 제31권5호
    • /
    • pp.517-523
    • /
    • 2001
  • 교정치료에서 원하는 치아이동을 위해서는 안정된 고정원이 필요한데 티타늄 미니스크류가 매식과 제거가 쉽고, 구강 내 여러 부위에서 적용이 가능하고, 환자가 느끼는 불편감이나 비용적인 부담이 적고, 제거 후에 치유가 빠르게 진행될 수 있는 등의 장점이 있어 최근에 교정적 고정원으로 사용되기 시작하였다. 티타늄 미니스크류를 교정적 고정원으로 사용한 임상 예들이 여러 편 발표되었는데 미니스크류의 이완이 가장 큰 실패의 원인으로 보고되고 있다. 그러나 지금까지 보고된 논문들에서 교정적 고정원으로 안정성을 줄 수 있는 스크류의 식립 길이에 관한 연구가 없는 상태이다. 교정적 고정원으로 미니스크류를 효과적으로 사용하기 위해서는 식립 부위에 따른 골구조와 골밀도 차이를 고려한 식립 길이에 관한 기준이 필요하다. 이에 본 연구에서는 성견의 상악골과 하악골에서 직경 2mm 티타늄 미니스크류를 다양한 길이로 식립하고 교정력을 적용한 후 그 안정성을 평가하여 교정적 고정원으로 사용될 수 있는 미니스크류의 식립 길이를 결정하고자 하였다. 미니스크류가 상악에서는 6mm 이상, 하악에서는 4mm 이상이 골 내에 식립될 때 8주 동안 200g의 교정력에 동요도나 위치변화를 보이지 않았다. 식립 부위로는 부착치은 부위 치근 사이에 식립될 때 구강청결이 유지되고 미니스크류 주변 치은조직에 자극을 주지 않아 정상적인 조직으로 유지 될 수 있었다. 또한 교정력 적용 8주 후 치근단 방사선 사진검사에서 스크류 주변 치근 흡수나 치조골 흡수, 치주 인대 손상이 관찰되지 않았다. 따라서 상$\cdot$하악 골밀도와 골구조의 차이를 고려하여 미니스크류의 골내 식립 길이를 적절히 조절함으로써 교정적 고정원으로 티타늄 미니스크류가 효과적으로 사용될 수 있다고 생각된다. 통계적으로 유의한 차이를 보였으나 Sn-Pg line와 Sn perp. 에서부터의 거리에는 차이가 없었다(p$44.32\%$ 떨어진 거리에 위치하였고, 피질골 절단술 시행시에 저항중심의 수직적 위치는 치경부에서 치근단 쪽으로 치근 길이의 $46.38\%$ 떨어진 거리에 위치하여 피질골 절단술 시행하지 않은 경우보다 치근단 쪽으로 이동되었으며, 후방견인력의 크기 변화에 따라 저항 중심의 수직적 위치는 변하지 않았다.Stainless Steel의 순이었다. 5. 비틀림실험은 0.016x0.022의 경우 Unitek Resilient가 가장 비틀림에 대한 저항이 큰데, 64.8회의 회전후 파절한다. 그 다음으로 Jinsung Stainless Steel, Unitek Hi-T, Ormco Stainless Steel, Unitek Standard(50.6회) 순이었다. 0.019x0.025의 경우 Jinsung Stainless Steel이 가장 커서 83.2회의 회전에 저항하고, Unitek Resilient, Unitek Standard의 순이고 Ormco와 Unitek Hi-T가 가장 저항력이 작았다. 6. 주사전자현미경으로 본 표면은 모든 제품에서 생산과정 중에 보이는 압흔과 pitting이 관찰되는데, 진성기업의 Stainless Steel은 가늘고 긴 압흔이 있으며 비교적

  • PDF

지르코니아 표면에 부착된 바이오필름에 대한 LED 치솔의 항균효과 (Antimicrobial effect of toothbrush with light emitting diode on dental biofilm attached to zirconia surface: an in vitro study)

  • 박종휴;김용건;엄흥식;이시영;이재관;장범석
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.160-169
    • /
    • 2019
  • 목적: 이번 연구의 목적은 정적인 방법과 동적인 방법으로 형성된 지르코니아 표면에 부착된 바이오필름에 대한 LED 칫솔의 항균 효과를 평가하고자 하였다. 연구 재료 및 방법: 구강 바이오필름을 형성하기 위해 직경 12 mm, 두께 2.5 mm의 지르코니아 디스크를 24-well plate(정적 방법)와 Center for Disease Control and Prevention (CDC) biofilm reactor (동적 방법)에 디스크를 넣어 바이오필름을 형성하였다. 디스크는 아무 처치도 하지 않은 대조군, 상용화된 광역학(PDT) 키트, 치솔질(brushing) 단독, LED 치솔군, LED 치솔과 에리스로신을 같이 적용한 군, 이렇게 5개 그룹으로 구성하였다. 각 군별 처치 후, 개별 디스크를 시험관에 넣고 60 초 동안 vortexing하여 세균을 분리한 후, 분리된 세균 용액을 선택 배지를 이용하여 살아있는 세균 수를 확인한 후 실험 방법에 따른 항균 효과를 계측하였고, 주사전자현미경(SEM)을 통하여 세균의 형태 변화를 관찰하였다. 결과: 바이오필름의 형성과 구성비는 동적인 방법과 정적인 방법에 따른 차이는 관찰되지 않았다. 대조군과 실험군간에 세균의 생존률에 유의한 차이가 있었다(P < 0.05). LED 치솔과 에리스로신을 같이 적용한 군에서 가장 높은 항균 효과가 관찰되었다(P < 0.05). 주사전자현미경 사진상에서 광역학치료군과, LED 치솔군, LED 치솔과 에리스로신을 같이 적용한 군은 세균의 형태 변화가 관찰되었으나, 대조군과 치솔질 단독 사용군에서는 세균의 형태 변화가 관찰되지 않았다. 결론: 이번 연구 결과 지르코니아 표면에 부착된 바이오필름을 효과적으로 제거하는 방법으로 LED 치솔과 에리스로신을 같이 적용하는 것이 추천된다.