• Title/Summary/Keyword: 임플란트 식립

Search Result 490, Processing Time 0.031 seconds

디지털 가이드 시스템과 사전 제작된 임플란트 상부보철물을 이용한 전치부의 임플란트 수복 : 증례보고

  • Choi, Yongkwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.30 no.1
    • /
    • pp.24-32
    • /
    • 2021
  • Dental implant have been in use for a long time to restore at missing tooth. But, To place dental implant at good position very is difficult. Improperly positioned dental implants make some problems to have a good function of dental implant. so, To place dental implant at accurate position is the most important step throughout the whole process. Digital guided system of dental implant is very useful to have a accurate position of dental implant and it makes upper restoration more esthetic and funcional.

Cortical bone strain during the placement of orthodontic microimplant studied by 3D finite element analysis (3차원 유한요소법을 이용한 교정용 마이크로임플란트 식립 시의 피질골 스트레인 해석)

  • Nam, Ok-Hyun;Yu, Won-Jae;Kyung, Hee-Moon
    • The korean journal of orthodontics
    • /
    • v.38 no.4
    • /
    • pp.228-239
    • /
    • 2008
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion. Methods: A 3D finite element method was used to model the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) Into 1 mm thick cortical bone with a pre-drilled hole of 0.9 mm in diameter. A total of 1,800 analysis steps was used to simulate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, was observed in the bone along the whole length of the microimplant. At the bone in the vicinity of the screw tip, strains of higher than 100% was recorded. The insertion torque was calculated at approximately 1.2 Ncm which was slightly lower than those measured from the animal experiment using rabbit tibias. Conclusions: The insertion process of a microimplant was successfully simulated using the 3D finite element method which showed that bone strains from a microimplant insertion might have a negative impact on physiological remodeling of bone.

Retrospective study on marginal bone loss around maxillary anterior implants with or without bone graft (상악 전치부에서 골 이식 유무에 따른 임플란트 변연골 소실에 관한 후향적 연구)

  • Hwang, Hee-Sun;Jung, Ji-Hye;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: This study is to evaluate the clinical significance of implantation with simultaneous bone graft by comparing the marginal bone loss around maxillary anterior implants with or without bone graft. Materials and methods: Patients treated with implant-retained restorations on maxillary anterior region at Implant Center, Dental Hospital, Wonkwang University between June 2011 and May 2014 were included in this study. Date of implant placement, implant diameter, implant length, implant-abutment connection type and whether the bone graft was done were investigated. The patient's periapical radiographs taken immediately after implantation and at the most recent visit were compared. Marginal bone loss was measured using Emago advanced v5.6 program (Oral diagnostic systems, Amsterdam, Netherlands). Statistical analysis was done in independent t-test by using SPSS 22.0 program. Results: As a result of observing on 83 implants (without bone graft: 44, with bone graft: 39) of 52 patients for 6 - 45 months (average: 18.4 months), implants without bone graft showed $1.42{\pm}0.42mm$, implants with bone graft showed $1.28{\pm}0.45mm$ of marginal bone loss. Conclusion: In limitations of this study, implants with simultaneous bone graft had significantly less marginal bone loss than implants without bone graft.

구순 구개열 성장기 환자에서 임플란트 치료

  • 정필훈;강나라;홍종락;서병무;명훈;황순정;최진영;이종호;김명진
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.5 no.2
    • /
    • pp.117-122
    • /
    • 2002
  • 성장기 환자에서의 각 부위별 임플란트 식려 시기를 요약해보면 다음과 같다. 1) 상악전방부 : 외상이나 선천적 결손을 해결하는 방법으로 임플란트를 사용하는 술식이 권장하지만 성장이 완료되지 않았기 때문에 야기되는 문제를 해결하기 위해 성장이 완료될 때까지 연기하는 것이 좋다. 2)상악 후방부: 수직적인 성장량이 최고 1cm까지 일어날 수 있으면 상악동의 흡수로 조기에 임플란트 침강과 치근부의 노출을 야기할 수 있다. 그리고 동시에 보철에 의한 구개열의 횡적인 성장방해를 피해야한다. 3) 하악 전방부 : 무치증 아이에서 임플란트의 조기식립이 적응증이 되는 유일한 곳으로 치아가 없을 때는 치조골의 성장이 최소이며 초기에 횡적, 후방 성장이 대부분 완료된다. 그러나 단일 임플란트 식립은 권장되지 않는다. 4)하악후방부: 늦게까지 성장변화가 지속되기 때문에 전후방, 횡적, 수직적 성장의 많은 양이 일어난다. 하악의 회전성장의 영향을 많이 받아 하악 무치악에서 조기 임플란트 사용한 보고도 적고. 자연치아에 인접하여 임플란트를 식립한 기록은 있으나 골격성장이 완료될 때 까지는 식립하지 않는 것이 좋다.

  • PDF

The effects of local factors on the survival of dental implants: A 19 year retrospective study (임플란트의 생존율에 영향을 미치는 국소적 인자에 대한 19년간의 후향적 연구)

  • Kim, Sung-Hoi;Kim, Sun-Jai;Lee, Keun-Woo;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.1
    • /
    • pp.28-40
    • /
    • 2010
  • Purpose: The aim of this retrospective study was to provide long-term data about the correlation between multifactorial local factors and the survival of implants. Material and methods: During 19 years (1991 to 2009), 2796 implants were placed in 879 patients. From dental charts and radiographs, the following data were collected: patient's age at implant placement, gender, implant system, surface, length, diameter, location of implant placement, bone quality, primary stability, type of prosthesis. The correlations between these data and implant survival were analyzed. Statistical analysis was performed using Kaplan-Meier survival analysis, Chi-square test, odds ratio. Results: 1. Among the 2796 implants, 150 implants failed that resulted in a cumulative survival rate of 94.64%. The cumulative survival rate of smooth surface implants (91.76%) was lower than rough surface implants (96.02%). 2. Anatomic location, implant surface, diameter of smooth surface implant, primary stability, type of prosthesis, patient's age and gender were significantly associated with implant survival (P < .05). 3. No significant difference in implant survival was found in relation to the following factors: implant length, bone quality, diameter of rough surface implants and type of rough surface according to implant manufacturer (P < .05). Conclusions: Local factors such as anatomic location, implant surface, diameter of smooth surface implant, primary stability and type of prosthesis have a significant effect on implant survival.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

THE BONE GRAFT DECLINED. IS THERE STILL A ROLE FOR IMPLANT SURGERY? (골 이식술이 환자에 의해 거부되는 경우 : 임프란트 술식이 여전히 치료방법으로서 의미를 가질 수 있는가에 관한 고찰)

  • Yang, Yun-Seok;Worthington, Philip
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.4
    • /
    • pp.362-366
    • /
    • 1997
  • 골의 퇴축 혹은 수술시의 절제로 인해 임플란트를 식립하기엔 불충분한 악골을 가진 환자에 있어서 골 이식술의 필요성은 오랫동안 논의 되어왔다. 골이식술은 악골의 전체 두께(full thickness)결손시 연결성(continuity)의 수복, 혹은 표면(surface)에서의 골상실시 보강(augmentation)목적으로 쓰일 수 있다. 따라서 술자들은 임플란트를 식립하기에 불충분한 악골을 가진 환자에 있어 골 이식술에 권유하게된다. 그러나, 골 이식술은 donor site 의 morbidity혹은 수술에 대한 두려운, 추가되는 비용에 대한 염려등으로 인해 환자에 의해 거부될 때가 종종 있다. 악골 결손으로 인해 골이식없이는 임플란트를 식립하기 어려운 경우에 있어서도 임플란트 술식이 여전히 해결책이 될 수 있을까? 다음의 두가지 증례를 통해 저자등은 골이식술 없이는 임플란트르 식립하기 어려운 경우에 있어서도 임플란트 술식이 여전히 치료방법으로서 의미가 있었음을 보고하는 바이다.

  • PDF

Implant Placement in Growing Adolescents : a Literature Review (성장기 소아 청소년 환자에서의 치과 임플란트 식립)

  • Shin, Hyun-Seung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.270-274
    • /
    • 2015
  • Although there are a number of studies on the treatment planning and the prognosis of dental implants, limited studies provide the information on the implant placement on growing adolescents. The aim of this review is to discuss the use of dental implants in growing patients and the impact of skeletal and dentoalveolar growth on the long-term stability of implants. The general information regarding skeletal growth of maxilla and mandible would be briefly reviewed and the general treatment options would be discussed.

Effects of implant thread profile on insertion stress generation in cortical bone studied by dynamic finite element simulation (유한요소 모사해석을 통한 임플란트 나사산 형상이 치밀골의 식립응력에 미치는 영향 분석)

  • Yu, Won-Jae;Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.279-286
    • /
    • 2014
  • Purpose: The aim of this study was to investigate the effect of implant thread profile on the marginal bone stresses which develop during implant insertion. Materials and methods: Four experimental implants were created by placing four different thread systems on the body ($4.1mm{\times}10mm$) of the ITI standard implant. The thread types studied in this study included the buttress, v-shape, reverse buttress, and square shape threads. In order to examine the insertion stress generation, 3D dynamic finite element analysis was performed which simulated the insertion process of implants into a 1.2 mm thick cortical bone plate (containing 3.5 mm pilot hole) using a PC-based DEFORM 3D (ver 6.1, SFTC, Columbus, OH, USA) program. Results: Insertion stresses higher than human cortical bone developed around the implants. The level of insertion stresses was much different depending on the thread. Stress level was lowest near the v-shape thread, and highest near the square shaped thread. Difference in the interfacial bone stress level was more noticeable near the valley than the tip of the threads. Conclusion: Among the four threads, the v-shape thread was turned out to minimize the insertion stress level and thereby create better conditions for implant osseointegration.

Initial Changes of Implant Stability from Installation during Early Bone Healing (임플란트 식립 후 초기 안정성의 변화)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.3
    • /
    • pp.272-279
    • /
    • 2013
  • The concept of implant stability was basically originated from the relative condition of bone-implant interface and has some meanings for evaluation of that interface. In addtion, it has been used for the investigation of initial bone healing process after fixture installation because a degree of micromotion around interface can affect unfavorable clinical results. The purpose of this study is to investigate the mode of initial bone healing from fixture installation through prospective trial. Thirty fixtures were consecutively installed in mandibles of 26 patients with single tooth loss area and then healing abutment were secured for one-stage surgery meothod. Resonance frequency analysis was performed with one week interval during 12 weeks and periapical radiographs were taken at each month. Although marginal bone level change was not shown through observation period (P>0.05), statistical difference of implant stability was shown through 4 and 6 week (P<0.05) and was not shown after 6 week (P>0.05) according to the bone quality. Initial bone healing process is a successive process of bone resorption and favorable bone healing result might be postulated at 4 week interval after installation through RFA.