• 제목/요약/키워드: 임펠러(impeller)

검색결과 389건 처리시간 0.022초

효율향상을 위한 폐수처리용 2 Vane 펌프 설계 최적화 (Design Optimization on 2 Vane Pump of Wastewater Treatment for Efficiency Improvement)

  • 김성;마상범;김진혁
    • 한국수소및신에너지학회논문집
    • /
    • 제32권4호
    • /
    • pp.277-284
    • /
    • 2021
  • This paper deals with multi-objective optimization using response surface method to improve the hydraulic performances of a 2 vane pump for wastewater treatment. For analyzing the internal flow field in the pump, steady Reynolds-averaged Navier-Stokes equations were solved with the shear stress transport turbulence model as a turbulence closure model. The impeller and volute variables were defined in the shape of the 2 vane pump. The objective functions were set to satisfy the total head at the design flow rate as well as to improve the efficiency. The hydraulic performance of the optimally designed shape was verified by numerical analysis results.

동물 세포 반응기에서의 초미세 통기법이 산소 전달 속도와 세포 생존율에 미치는 영향 (Effect of Microsparged Aeration on Oxygen Transfer Rate and Cell Viability in Mammalian Cell Culture Bioreactor)

  • 김정모;장건희;최춘순;김정회
    • 한국미생물·생명공학회지
    • /
    • 제29권4호
    • /
    • pp.240-247
    • /
    • 2001
  • 본 연구에서는 동물세포 배양장치를 개발키 위한 기초연구로서 초미세 통기법이 산소 전달 속도와 세포의 생존율에 미치는 영향에 대해 알아보았다. 통기 장치로 통기 구멍 크기가 다른 microsparger 를 사용하였을 때, 모형 반응기 내에서 측정한 산소 전달계수(k$_{L}$a)는 microsprager의 통기 구멍 크기가 작아질수록 현저히 증가하였다. 이는 공기 방울들과 매질 사이의 접촉 면적이 증가했기 때문인 것으로 판단된다. 두 가지 다른 형태의 임펠러 (square-pitch marine impeller 와 $45^{\circ}$) pitched flat blade impller) 를 사용하여 교반하였을 때, $k_{L}$ a 값은 marine impeller 를 사용하였을 때 다소 높았다. $100\mu\textrm{m}$ 이하의 통기 구멍을 가진 microsparger 를 사용하여 직접 통기가 세포에 미치는 손상에 대해 알아본 결과, 세포들의 손상 정도는 통기 속도가 증가할수록, 공기방울 크기가 작아질수록 더 커졌다. 2.5 L 용량의 소형 세포 반응기에 $0.5\mu\textrm{m}$ 의 통기 구멍 크기를 가진 micro-sparger를 장치하여 세포를 배양한 결과 , 지속적인 통기시에는 세포의 생존율이 80% 이하로 떨어지고, 정상적인 성장을 하지 못하였다. 그러나 용존 산소 농도가 20% 이하로 떨어졌을 때에만 통기하였을 때 세포는 정상적으로 자랐으며 세포 생존율도 대수기 전반에 걸쳐 90% 이상을 유지하였다.

  • PDF

하수처리 공법별 네오하이드로포일 교반기의 적용 특성 및 효과 (Characteristic Features and Effect of Neo-Hydrofoil Impeller Applied in Sewage Treatment Plants)

  • 주윤식;손건태;배영준;이승환
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.187-196
    • /
    • 2016
  • In this study, a newly developed agitator with hydrofoil impeller applied to actual biological process in advanced wastewater treatment plant was evaluated. Several series of experiments were conducted in two different wastewater treatment plants where actual problems have been occurred such as the production of scums and sludge settling. For more effective evaluation, computational fluid dynamics (CFD) and measurements of MLSS (Mixed Liquor Suspended Solids) and DO (Dissolved Oxygen) were used with other measuring equipments. After the installation of one unit of vertical hydrofoil agitator in plant A, scum and sludge settling problems were solved and more than seventy percent of operational energy was saved. In case of plant B, there were three cells of each anoxic and anaerobic tanks, and each cell had one unit of submersible horizontal agitator. After the integration of three cells to one cell in each tank, and installation of one vertical hydrofoil agitator per tank, all the problems caused by improper mixing were solved and more than eighty percent of operational energy was found to be saved. Simple change of agitator applied to biological process in wastewater treatment plant was proved to be essential to eliminate scum and sludge settling problems and to save input energy.

토네이도 블록형 선회류 침사제거기의 침사제거효율 평가 (Evaluations of Grit Removal Efficiency of Tornado Block-Type Vortex Grit Separator)

  • 김종제;이범수;염철민;임희재;정석모
    • 상하수도학회지
    • /
    • 제19권3호
    • /
    • pp.288-294
    • /
    • 2005
  • This study was conducted to evaluate the grit removal efficiency of tornado block-type vortex grit separator. Vortex grit separator was manufactured for this study, and it was characterized by the impeller and tornado block installed in separator. Impeller was installed to increase water velocity in the separator and tornado block was installed to increase the grit lifting efficiency. Pilot study was also conducted in A sewage treatment plant (STP) in Gyeonggi province from November 2003 to May 2004 (64 days). Major findings are as follows. 1. Impeller was proven to increase water velocity in the grit separator, especially in low flow rate. This influence will increase separation ratio of organics from grits, preventing those organics from sedimentation. 2. Sand (with 0.2~0.3mm size) removal efficiency was over 98 % and 96 %, at the flow rate of $500m^3/day$ and $750m^3/day$ under the condition that impeller rotation velocity kept at 15 rpm. Originally that grit separator was designed to have the capacity of $500m^3/day$. $750m^3/day$ was tried to investigate the performance of this type of grit separator under overload condition. Stable grit removal was still available to the extent of 150% of designed capacity. 3. It took less than 3 minutes for the grit separator to completely lift out 3 kgs of 0.2-0.3 mm sized, settled sand at the bottom to 2,060 mm high above water surface. But it showed the tendency to spend a little more time on lifting the grit as the grit size and the vertical height of the lift increased. 4. During experimental duration in A STP, it was found that the average amount of inlet grit was about 981 g/day (160~1,685 g/day) under $500m^3/day$ of operation condition, but it varied so severely during the experimental duration. After classification of discharged grit according to its size, grit with 0.3-0.42 mm size was found as largest part of output.

HFC-134a용 1300RT급 원심압축기의 설계 및 성능시험 (Design and Performance Test of 1300RT Centrifugal Compressor for a HFC-134a Turbo-Chiller)

  • 고경태;최영민;신정관;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.672-677
    • /
    • 2001
  • This study has been conducted to design the high efficiency centrifugal compressor for a HFC-134a. The 2-stage centrifugal compressor consists of inlet guide vanes, two impellers with splitters, a deswirler, a vaneless diffuser and a volute casing. We have designed the high efficiency centrifugal compressor by applying the repeated design procedure including a meanline design, a 3D geometry generation of 1st and 2nd impellers etc. Also, a fluid dynamic calculation of impellers and deswirler have been conducting using a commercial code STAR-CD.

  • PDF

PIV를 이용한 디퓨저펌프 정익에서의 성능과 유동특성에 관한 연구 (A Study on Flow Characteristics and Efficiency in Guide Vane of Diffuser Pump Using PIV Measurement)

  • 김정환;김범석;김진구;함승덕;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권5호
    • /
    • pp.633-640
    • /
    • 2003
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational velocity were selected as experimental condition. Optimized cross correlation Identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. Variable flow pattern are represented quantitatively at the stator region.

PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측 (Measurement of the Velocity field of Rotor-Stator in a Centrifugal Turbine Pump by Using PIV)

  • 임유청;서민식;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.11-18
    • /
    • 1998
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stator region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented by direct calculation of correlation coefficients. Fine optical setup deeply concerned with PIV performance is arranged for accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

연료전지 버스용 공기공급시스템 개발 (Development of Air Supply System for Fuel Cell Electric Bus)

  • 김우준;박창호;조경석;오창훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.561-564
    • /
    • 2007
  • FCEV uses electric energy which generated from the reaction between Hydrogen and Oxygen in fuel cell stack as driving force. As fossil fuels are exhausted, fuel cell is regarded as a potent substitute for next generation energy source, and thus, most of car-makers make every efforts to develop fuel cell electric vehicle (FCEV). In addition, fuel cell is also beneficial in aspect of environment, because only clean water is produced during chemical reaction process instead of harmful exhausted gas. Generally, Hydrogen is supplied from high-pressured fuel tank, and air blower (or compressor) supply Oxygen by pressurizing ambient air. Air blower which is driven by high speed motor consumes about $7{\sim}8$ % of energy generated from fuel cell stack. Therefore, the efficiency of an air blower is directly linked with the performance of FCEV. This study will present the development process of an air blower and its consisting parts respectively.

  • PDF

연료전지 버스용 공기공급시스템 개발 (Development of Air Supply System for FCEV Bus)

  • 박창호;조경석;김우준;오창훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.417-420
    • /
    • 2006
  • FCEV uses electric energy generated from the reaction between Hydrogen and Oxygen in fuel cell stack as driving force. As fossil fuels are exhausted, fuel cell is regarded as a potent substitute for next generation energy source, and thus, most of car-makers make every efforts to develop fuel cell electric vehicle (FCEV). In addition, fuel cell is also beneficial in aspect of environment, because only clean water is produced during chemical reaction process instead of harmful exhausted gas. Generally, Hydrogen is supplied from high-pressured fuel tank, and air blower (or compressor) supplies Oxygen by pressurizing ambient air. Air blower which is driven by high speed motor consumes about $7{\sim}8%$ of energy generated from fuel cell stack. Therefore, the efficiency of an air blower is directly linked with the overall performance of FCEV. This study will present developing process of an air blower and its consisting parts respectively.

  • PDF

기액 이상류시의 스크류식 원심펌프의 압력분포 (Pressure Distributions of a Screw-type Centrifugal Pump Operating in Air-Water Two-Phase Flow)

  • 김유택;최민선;이영호
    • 한국유체기계학회 논문집
    • /
    • 제4권3호
    • /
    • pp.39-45
    • /
    • 2001
  • It is reported recently that the pump head deterioration near the best efficiency point, from single-phase flow to the choke due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. Moreover, at a narrow tip clearance, the pump head became partially higher in two-phase flow than that in single-phase flow. However, the internal pressure fluctuations on this pump due to air entrainment have not been studied yet. For that reason, we have examined the influences of void fraction, flow coefficient and impeller tip clearance on pressure fluctuations in the casing. The void fraction became larger, the influence of tip clearance on pressure distribution became less.

  • PDF