• Title/Summary/Keyword: 임상적용

Search Result 3,287, Processing Time 0.029 seconds

Reverse Superficial Sural Artery Flap for the Reconstruction of Soft Tissue Defect Accompanied by Fracture of the Lower Extremity (하지 골절과 동반된 연부조직 결손 재건을 위한 역행성 비복동맥 피판술)

  • Han, Soo-Hong;Hong, In-Tae;Choi, SeongJu;Kim, Minwook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.3
    • /
    • pp.253-260
    • /
    • 2020
  • Purpose: Soft tissue defects of the distal lower extremity are commonly accompanied by a fracture of the lower extremities. Theses defects are caused by the injury itself or by complications associated with surgical treatment of the fracture, which poses challenging problem. The reverse superficial sural artery flap (RSSAF) is a popular option for these difficult wounds. This paper reviews these cases and reports the clinical results. Materials and Methods: Between August 2003 and April 2018, patients who were treated with RSSAF for soft tissue defects of the lower third of the leg and ankle related to a fracture were reviewed. A total of 16 patients were involved and the mean follow-up period was 18 months. Eight cases (50.0%) of the defects were due to an open fracture, whereas the other eight cases (50.0%) were postoperative complication after closed fracture. The largest flap measured 10×15 cm2 and the mean size of the donor sites was 51.9 cm2. The flap survival and postoperative complications were evaluated. Results: All flaps survived without complete necrosis or failure. One case with partial necrosis of the flap was encountered, but the wound healed after debridement and repair. One case had a hematoma with a pseudoaneurysmal rupture of the distal tibial artery. On the other hand, the flap was intact and the wound healed after arterial ligation and flap advancement. A debulking operation was performed on three cases for cosmetic reasons and implant removal through the flap was performed in three cases. No flap necrosis was encountered after these additional operations. Conclusion: RSSAF is a relatively simple and safe procedure for reconstructing soft tissue defects following a fracture of the lower extremity that does not require microsurgical anastomosis. This can be a useful treatment option for soft tissue defects on the distal leg, ankle, and foot.

Influence of finish line design on the marginal fit of nonprecious metal alloy coping fabricated by 3D printing, milling and casting using CAD-CAM (CAD-CAM을 이용한 3D printing, milling, casting 방법의 비귀금속 코핑의 지대치 변연 적합도 연구)

  • Seo-Rahng Kim;Myung-Joo Kim;Ji-Man Park;Seong-Kyun Kim;Seong-Joo Heo;Jai-Young Koak
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.1
    • /
    • pp.1-17
    • /
    • 2023
  • Purpose. The purpose of this study was to examine the correlation between the finish line designs and the marginal adaptation of nonprecious metal alloy coping produced by different digital manufacturing methods. Materials and methods. Nonprecious metal alloy copings were made respectively from each master model with three different methods; SLS, milling and casting by computer aided design and computer aided manufacturing (CAD-CAM). Twelve copings were made by each method resulting in 72 copings in total. The measurement was conducted at 40 determined reference points along the circumferential margin with the confocal laser scanning microscope at magnification ×150. Results. Mean values of marginal gap of laser sintered copings were 11.8 ± 7.4 ㎛ for deep chamfer margin and 6.3 ± 3.5 ㎛ for rounded shoulder margin and the difference between them was statistically significant (P < .0001). Mean values of marginal gap of casted copings were 18.8 ± 20.2 ㎛ for deep chamfer margin and 33 ± 20.5 ㎛ for rounded shoulder margin and the difference between them was significant (P = .0004). Conclusion. Within the limitation of this study, the following conclusions were drawn. 1. The variation of finish line design influences the marginal adaptation of laser sintered metal coping and casted metal coping. 2. Laser sintered copings with rounded shoulder margin had better marginal fit than deep chamfer margin. 3. Casted copings with deep chamfer margin had better marginal fit than rounded shoulder margin. 4. According to the manufacturing method, SLS system showed the best marginal fit among three different methods. Casting and milling method followed that in order.

Manufacture and Characteristics of Peel-off Pack for Natural Cosmetics Using Pullulan and Polysaccharides (Pullulan과 Polysaccharides를 이용한 천연화장품용 필 오프 팩의 제조 및 특성)

  • Jun Soo Kwak;So Young Jung;So Min Lee;Seok-Ju Lee;Sofia Brito;Byungsun Cha;Hyojin Heo;Lei Lei;Sang Hun Lee;Ha-Hyeon Jo;You-Yeon Chun;Ye Ji Kim;Hyung Mook Kim;Mi-Gi Lee;Byeong-Mun Kwak;Bum-Ho Bin
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.1
    • /
    • pp.67-74
    • /
    • 2023
  • In this study, for a natural cosmetics market, we sought to explore alternatives that can replace polyvinyl alcohol (PVA) of peel-off packs. A peel-off type pack was prepared by combining pullulan, a water-soluble polysaccharide, and other polysaccharides (sodium hyaluronate, cellulose gum, hydroxyethyl cellulose, sodium alginate, corn starch), and the pH, viscosity, and stability against temperature of each peel-off type pack were confirmed. The thickness and tensile strength of the manufactured film were measured for comparison with the PVA peel-off type pack, and applicability, drying speed, and removal degree were measured. Among them, the pullulan-sodium hyaluronate peel-off type pack showed excellent film formation ability to replace the peel-off type pack containing PVA with 5.12% thin film thickness and 4.23% high film tensile strength. When applied to actual skin, the degree of spread of the pack, the usability that can be uniformly applied, and the formation and removal strength of the film when removed after drying were also similar to the peel-off type pack containing PVA. Therefore, it was confirmed that the film formed of pullulan-sodium hyaluronate showed enough physical properties to replace the PVA of the peel-off type pack as a natural peel-off type pack.

Evaluation of HbA1c Levels Via the Latex Immunoturbidimetric Method by Using Chemistry Autoanalyzer (자동화학분석기에서의 라텍스 면역비탁법의 Autolab HbA1c 평가)

  • Jo, Yongjun;Lee, So-young;Park, Hae-il;Kim, YeongSic;Lee, Jehoon;Kim, Yonggoo;Han, Kyungja
    • Laboratory Medicine Online
    • /
    • v.2 no.1
    • /
    • pp.10-14
    • /
    • 2012
  • Background: Measurement of HbA1c levels is widely used to diagnose diabetes mellitus and to evaluate and monitor plasma-glucose concentrations over 6-8 weeks. In this study, we evaluated the diagnostic performance of the newly developed latex immunoturbidimetric method by using Autolab HbA1c. Methods: We analyzed and compared the diagnostic performance of Autolab HbA1c with that of Toshiba 200FR between April 2009 and July 2009. According to guidelines (EP5-A2, EP6-P, EP9-A2) of the clinical and laboratory standards institute (CLSI), we compared linearity, precision and correlation of Autolab HbA1c with those of G7 (Tosoh Corp., Kyoto, Japan) by using high-performance liquid chromatography (HPLC) method. Results: Data obtained using Autolab HbA1c showed good linearity in mixtures of samples with low (3.1%) and high (15.1%) levels of HbA1c (r2=0.9997). In the analysis of within-run precision of the samples with HbA1c levels of 5.1% and 12.1%, the SDs were 0.04 and 0.06 and covariances of these samples were 0.8% and 0.5%, respectively. In the Deming regression model, the regression equation was as follows: Autolab HbA1c=1.0859×Tosoh HPLC-0.6957. Conclusions: In this study, Autolab HbA1c method showed better performance characteristics than Tosoh G7 did. In reference review, there was no interference of variant hemoglobin. The data acquisition time of Autolab HbA1c was lower than that of Tosoh G7. The advantages of Autolab HbA1c are that it can be used as an autoanlyzer in routine chemical analysis, it does not require pre-analytical treatment, and the samples are automatically treated with distilled water for hemolysis.

Effects of The Sub ROI Changes on Exposure Index (Sub ROI 변화가 노출지수에 미치는 영향)

  • Young-Cheol Joo;Dong-Hee Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1149-1155
    • /
    • 2023
  • This study aims to investigate the effect of changes in the Sub ROI on exposure index(EI) and to present indicators of changes in EI values that may occur when changing Sub ROI in clinical practice. This study was conducted on a subject of 20 cm of acrylic for a setting similar to abdominal radiography, and the specifications of one acrylic sheet is 20 × 20 × 5 cm. The survey conditions were the same as 80 kVp , 320 mA, 25 ms, SID 110 cm and the Sub ROI obtained 30 images for each type using five types provided by the equipment company. The EI value provided by the equipment and entrance skin exposure(ESE) were compared and analyzed. The mean value of EI according to the change in Sub ROI was 101.18±0.27 for LS, 106.57±0.31 for AEC, 107.74±0.39 for VR, 107.90±0.38 for HR, and 109.72±0.32 for SS (p<0.01). The average value of ESE by sub ROI type (LS, AEC, VR, HR, SS) was measured to be 476.45±1.71 μGy, 476.92±1.48 μGy, 476.14±2.30 μGy, 475.61±1.96 μGy, and 477.14±1.46 μGy, with statistically significant differences (p<0.01). As a result of this study, the EI according to the sub ROI type is based on LS(109.72), which represents the minimum value. AEC increased 5.3%, VR increased 6.4%, HR increased 6.6%, SS increased 8.4%, and overall, increased by about 5.3%. As for the average value of ESE, HR(475.61 μGy)type showed the minimum value, and based on this, AEC increased 0.27%, VR increased 0.11%, LS increased 0.17%, SS increased 0.32%, and overall, increased by about 0.17%.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Risk Factors for Binge-eating and Food Addiction : Analysis with Propensity-Score Matching and Logistic Regression (폭식행동 및 음식중독의 위험요인 분석: 성향점수매칭과 로지스틱 회귀모델을 이용한 분석)

  • Jake Jeong;Whanhee Lee;Jung In Choi;Young Hye Cho;Kwangyeol Baek
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.685-698
    • /
    • 2023
  • This study aimed to identify binge-eating behavior and food addiction in Korean population and to determine their associations with obesity, eating behaviors, mental health and cognitive characteristics. We collected clinical questionnaire scores related to eating problems (e.g. binge eating, food addiction, food cravings), mental health (e.g. depression), and cognitive functions (e.g. impulsivity, emotion regulation) in 257 Korean adults in the normal and the obese weight ranges. Binge-eating and food addiction were most frequent in obese women (binge-eating: 46.6%, food addiction: 29.3%) when we divided the participants into 4 groups depending on gender and obesity status. The independence test using the data with propensity score matching confirmed that binge-eating and food addiction were more prevalent in obese individuals. Finally, we constructed the logistic regression models using forward selection method to evaluate the influence of various clinical questionnaire scores on binge-eating and food addiction respectively. Binge-eating was significantly associated with the clinical scales of eating disorders, food craving, state anxiety, and emotion regulation (cognitive reappraisal) as well as food addiction. Food addiction demonstrated the significant effect of food craving, binge-eating, the interaction of obesity and age, and years of education. In conclusion, we found that binge-eating and food addiction are much more frequent in females and obese individuals. Both binge-eating and food addiction commonly involved eating problems (e.g. food craving), but there was difference in mental health and cognitive risk factors. Therefore, it is required to distinguish food addiction from binge-eating and investigate intrinsic and environmental risk factors for each pathology.

Latest Supreme Court Decision on Proof of Causation in Medical Malpractice Cases - Focusing on Supreme Court decision 2022da219427 on August 31, 2023 and the Supreme Court decision 2021Do1833 on August 31, 2023 - (의료과오 사건에서 인과관계 증명에 관한 최신 대법원 판결 - 대법원 2023. 8. 31. 선고 2022다219427 판결 및 대법원 2023. 8. 31. 선고 2021도1833 판결을 중심으로 -)

  • HYEONHO MOON
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.4
    • /
    • pp.3-36
    • /
    • 2023
  • The main issue in medical malpractice civil litigation is medical negligence and the causal relationship between medical negligence and damages. Regarding the presumption of causality in cases where medical negligence is proven, there is a previous Supreme Court decision 93da52402 on February 10, 1995, but it is difficult to find a case that satisfies the textual requirements of the above decision, and yet, in practice, the above decision is cited. In many cases, causal relationships were assumed, and criticism was consistently raised that it was inconsistent with the text of the above judgment. In its ruling, the Supreme Court reorganized and presented a new legal principle regarding the presumption of causality when medical negligence is proven in a civil lawsuit. According to this, If the patient proves ① the existence of an act that is assessed as a medical negligence, that is, a violation of the duty of care required of an ordinary medical professional at the level of medical care practiced in the field of clinical medicine at the time of medical practice, and ② that the negligence is likely to cause damages to the patient, the burden of proving the causal relationship is alleviated by presuming a causal relationship between medical negligence and damage. Here, the probability of occurrence of damage does not need to be proven beyond doubt from a natural scientific or medical perspective, but if recognizing the causal relationship between the negligence and the damage does not comply with medical principles or if there is a vague possibility that the negligence will cause damage, causality cannot be considered proven. Meanwhile, even if a causal relationship between medical negligence and damage is presumed, the party that performed the medical treatment can overturn the presumption by proving that the patient's damage was not caused by medical negligence. Meanwhile, unlike civil cases, the standard is 'proof beyond reasonable doubt' in criminal cases, and the legal principle of presuming causality does not apply. Accordingly, in a criminal case of professional negligence manslaughter that was decided on the same day regarding the same medical accident, the case was overturned and remanded for not guilty due to lack of proof of a causal relationship between medical negligence and death. The above criminal ruling is a ruling that states that even if 'professional negligence' is recognized in a criminal case related to medical malpractice, the person should not be judged guilty if there is a lack of clear proof of 'causal relationship'.

The effect of dental hygiene students' knowledge and attitude toward the elderly on the discrimination of the elderly (치위생학과 학생들의 노인에 대한 지식 및 태도가 노인차별주의에 미치는 영향)

  • Young-Sun Kim;Jung-Hwa Lee
    • Journal of Korean Dental Hygiene Science
    • /
    • v.6 no.2
    • /
    • pp.129-139
    • /
    • 2023
  • Background: The elderly population aged 65 or older in Korea is expected to continue to increase to 18.4% in 2023, and to enter a super-aged society at 20.6% in 2025. In clinical practice, the elderly discrimination of dental hygienists may experience difficulties during dental hygiene treatment due to an increase in the number of elderly patients due to aging, which can lead to maladjustment to work and turnover, so education on the understanding of the elderly is essential for students in the Department of Dentistry, who are prospective dental hygienists. Accordingly, a study was conducted to prepare for a super-aged society by studying the relationship between elderly discrimination and the knowledge and attitudes of the elderly, and to change the curriculum of universities and develop programs related to the elderly. Method: 204 students enrolled in the Department of Dentistry in D area were analyzed using the SPSS/WIN 25.0 program. The subject's geriatric discrimination, knowledge about the elderly, and attitude toward the elderly were calculated as the mean and standard deviation. T-test and one-way ANOVA were performed to verify the difference in geriatric discrimination according to the general characteristics of the subject, with a Scheffe' test applied for post-hoc analysis. Correlation analysis was conducted on the subject's geriatric discrimination, knowledge about the elderly, and attitudes toward the elderly. Results: Geriatrics scored 2.03±0.36 out of 4. Knowledge about the elderly was categorized as follows: physical domain 0.57±0.15; social domain 0.36±0.17; and psychological domain 0.35±0.20. The attitude toward the elderly was 3.86±0.27. Knowledge of the elderly averaged 11.27±3.30 points out of 25. The question with the highest percentage of correct answers to knowledge about the elderly was 'physical strength tends to decrease with age', which was 93.1%. The attitude toward the elderly according to the general characteristics of the study subjects showed significant differences in gender (p=0.040), age (p=0.026), and life experience with grandparents (p=0.001). The elderly discrimination of the study subjects showed a negative correlation in both attitude and knowledge toward the elderly, and among the elderly discrimination, there was a high positive correlation with regard to emotional avoidance (r=.892, p<0.001). Conclusion: College students are the leading players in caring for the elderly and are directly affected by aging social problems. Therefore, it is considered necessary to apply various programs in the state, society, and educational institutions to avoid negative prejudices that lead to positive thinking and discrimination against the elderly.

A Study of the New Positioning Guide Based on the Correlation between the Orbit Meatus Line and Mandibular Body Angle in Paranasal Sinus Parietoacanthial Projection(Water's Method) (코곁굴 두정비극방향 검사 시 안와이공선과 아래턱뼈 몸통각도의 상관관계를 이용한 새로운 자세잡이 기준에 관한 연구)

  • Yong-Min Son;Han-Yong Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.335-344
    • /
    • 2024
  • In this study, we aim to investigate the correlation between the lateral images of Korean skulls and the angle between the OML and the Body of the Mandible. Additionally, we seek to provide criteria for the ease of positioning in clinical settings and establish standardized imaging procedures for the PNS Water's view examination. This study was conducted on a total of 202 patients who visited the radiology department of a general hospital and examined the skull lateral radiography. In addition to the patient images, skull phantoms were also utilized, and images were obtained using GC85A and EOS equipment. In this research, abbreviations related to the angle of the Body of Mandible were defined using PACS on lateral images. Measurements were taken for various angles, including ramus of mandible angle(RIA), accurate OML angle(TIA), OML and IR Angle(OIA), total mandibular length(TML), ramus height(RH), the angle between the pogonion, gonion, and condylion(MA). The validity of these measurements was confirmed using the skull phantom in the study. The age-specific average range for RIA was 22.67° to 26.04°, with measurements of 23.14° for males and 24.78° for females. The age-related mean ranges for TIA and OIA were 35.98° to 38.31° and 72.27° to 75.25°, respectively. For males, TIA was 36.74° and OIA was 72.73°, while for females, TIA was 36.43° and OIA was 73.38°. The age-dependent measurements for TML and RH ranged from 85.73 mm to 89.60 mm and 62.60 mm to 70.87 mm, respectively. Male values were 90.54 mm and 70.78 mm, while female values were 85.13 mm and 61.54 mm for TML and RH, respectively. The age-specific average range for MA was 55.95° to 58.63°, with measurements of 57.96° for males and 57.76° for females. Correlation analysis revealed a positive correlation between RIA and OIA, as well as between RIA and TIA. Based on the results of this study, which indicate a positive correlation between the angle of the Body of Mandible and the OML, it can be inferred that adjusting the mandible vertically to align with the imaging receptor may contribute to more accurate image acquisition during PNS Water's view examination. Therefore, it is believed that there is value in utilizing this relationship as a criterion for establishing new positioning standards, which could enhance the utility of a new positioning guide.