• Title/Summary/Keyword: 일체형

Search Result 1,154, Processing Time 0.028 seconds

Static Cyclic Loading Test of the Seismic and Energy Simultaneous Retrofit Panel for Existing Unreinforced Masonry Buildings (기존 비보강 조적조 건축물의 내진 및 에너지 동시보강패널 정적반복가력실험)

  • Choi, Hyoung-Wook;Lee, Sang-Ho;Choi, Hyoung-Suk;Kim, Tae-Hyeong;Baek, Eun-Rim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.81-90
    • /
    • 2020
  • A textile and capillary tube composite panel(TCP) was developed to simultaneously retrofit the seismic performance and the energy efficiency (e.g. heating or insulation performance) of existing unreinforced masonry (URM) buildings. TCP is a light-weight mortar panel in which carbon textile reinforcements and capillary tubes are embedded. Textile reinforcements plays a role of seismic retrofit and capillary tubes that hot water circulates contribute to the energy retrofit. In this paper, the static cyclic loading tests were performed on the masonry walls with/without TCP to understand the seismic retrofit effect of TCP retrofit and the results were summarized. The results of the test showed that the TCP contributed to increase the capacity of the Shear strength and ductility of the URM walls. In addition, the deformation of the wall after cracking was substantially controlled by the carbon textile.

Shear Capacity of Composite Basement Walls (합성 지하벽의 전단성능)

  • 김성만;이성호;서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.3
    • /
    • pp.321-330
    • /
    • 2002
  • This paper presents the experimental results of composite basement wall in which H-pile and reinforced concrete wall are combined using shear connector Twelve specimens are tested to evaluate the shear capacity of the wall. Main variables in the test are composite ratio, distribution of shear connector, thickness of wall, shear-span ratio, and shear reinforcement. Test results indicate that the shear capacity of test specimens varies with the foregoing variables except the composite ratio. The results are compared with strengths predicted using the equations of ACI 318-99, Zsutty, and Bazant. Based on this investigation, a method for predicting the shear strength of composite basement walls is proposed.

Evaluation of Shear Strength for Reinforced Flat Plates Embedded with GFRP Plates (매립형 GFRP 판으로 보강된 플랫 플레이트의 전단강도 평가)

  • Hwang, Seung Yeon;Kim, Min Sook;Lee, Young Hak;Kim, Heecheul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.2
    • /
    • pp.121-128
    • /
    • 2014
  • In this study, The purpose of this study is to experimentally investigate the shear behavior of reinforced flat plate embedded with GFRP(glass fiber reinforced polymer) plate with openings. The GFRP shear reinforcement is manufactured into a plate shape with several openings to ensure perfect integration with concrete. The test was performed on 7 specimens. the parameters include the type of reinforcement and amount of the shear reinforcement., From the test, we analysed the crack, failure mode, Strain, load-displacement graph. a calculation of the shear strength of reinforced flat plate with GFRP plate based on the ACI 318-11 was compared with the test results. The results of the experiment indicate that GFRP plate is successfully applied as a shear reinforcement in the flat plate under punching shear.

Study on the Numerical Simulation of Debris Flow due to Heavy Rainfall (집중 강우에 따른 토석류 유출의 수치계산)

  • Kim, Jung-Han;Min, Sun-Hong;Kang, Sang-Hyeok
    • Spatial Information Research
    • /
    • v.17 no.3
    • /
    • pp.389-395
    • /
    • 2009
  • In spite of many numerical analysis of debris flow, a little information has been found out. In this paper the watershed is divided to apply rainfall runoff and to estimate debris flow integrating flow and soil article. We use the contour data to extract spatially distributed topographical information like stream channels and networks of sub-basins. A Quasi Digital Elevation Model (Q-DEM) is developed, integrated, and adopted to estimate runoff based on marked one. As a results, it has been found out that the debris flow was close to observed flow hydrograph. Because debris flow is finished in 30 second, it is important that we have to prepare its prior countermeasure to minimize the damage of debris flow. The GIS-linked model will provide effective information to plan river works for debris flow.

  • PDF

Comparison of Shear Strength Equation for Flat Plates with GFRP Plate (GFRP 판으로 보강된 플랫 플레이트의 전단강도식에 관한 규준의 비교 분석)

  • Kim, Min Sook;Hwang, Seung Yeon;Kim, Heecheul;Lee, Young Hak
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.4
    • /
    • pp.247-254
    • /
    • 2014
  • In this study, shear test performed to investigate the shear behavior of flat plate that reinforced by embedded GFRP(glass fiber reinforced polymer) plate with openings. Shape of the GFRP shear reinforcement is a plate with several openings to ensure perfect integration with concrete. The test parameters include the distance between the column face and the first line of GFRP plate and number of GFRP plate vertical strip. The result of test showed that when number of GFRP plate vertical strip was increased, shear strength improved. The shear strength for flat plate reinforced GFRP plate in various codes including ACI 318, BS 8110, EUROCODE 2, and KCI were compared to provide more rational approach for reinforced concrete flat plates with GFRP plate.

A Study on the Standard Drawings of Seoul Elementary School Architecture in 1960~70s (1960~70년대 서울시 국민학교 건축 표준설계도에 관한 연구)

  • Lee, Jung-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1718-1725
    • /
    • 2008
  • Until 1980s, Korean elementary school architecture has been stereotyped by standard drawings. But there have been very few researches focused on this subject, especially regional one. As an attempt to improve these conditions, this study reviewed standard drawings of elementary school architecture by Education Board of Seoul in 1964 and 1975. Both standard drawings were reviewed through items such as components making a set of standard drawings, floor plan, elevation design and subsidiary facilities. They have rectangular unit classrooms, single-corridor block plan and plain exterior having no symbolic images, which are the characteristics of typical Korean school architecture until 1980s. On the other hand, they reveal the unknown characteristics such as double-corridor block plan, classrooms in basement, toilets of conventional type placed on every floor and changes in details of openings and exterior wall.

For Sustainable Future with Sustainable Architecture - BiWP, New Wave of Building integrated Wind Power System (지속가능미래를 위한 신재생에너지 응용 친환경건축 방향 - 7. BiWP, 건물일체형 풍력 발전 시스템의 새바람)

  • Yoon, Jong-Ho
    • Korean Architects
    • /
    • s.475
    • /
    • pp.65-74
    • /
    • 2008
  • 1970년 초에 배럴당 1불하던 원유가가 지금은 120불을 상회하고 있다. 더욱 놀라운 것은 3년 전만 하더라도 40불 이하 수준이던 것이 불과 몇 년 사이에 3배 이상 급등해 버린 것이다. 우리는 아직 유가 100불 이상의 고유가 시대에 대한 고통을 실감하지 못하고 있지만, 빠른 시일 안에 대항한 형태로 우리를 불편하게 하고, 더가서는 사회 경제 문화 등 모든 우리의 활동패턴에 근본적 변화를 일으킬 것이라는데는 어느 누구도 이의를 달지 못할 것이다. 한편 90년대만 하더라도 친환경 건축기술은 선택적 사양으로 인식되어 왔으며, 일부 고급건물 또는 데모성격의 건물에만 반영되던 미래의 기술 분야로 간주되어왔다. 하지만 10년 남짓 지난 지금 우리 주변에서 가장 흔하게 접할 수 있는 용어 중의 하나가 친환경, 지속가능, 그린, 에코 등 이며, 최근 많은 건설사가 고민하고 있는 가장 중요한 이슈가 친환경 건축 관련 기술이 되어버렸다. 최근 유가의 급등세 보다는 더디다 할 지라도 몇 년 사이에 벌어지고 있는 제도적, 사회 경제적 변화 동향을 돌이켜 볼 때 건축계 또한 매우 빠른 속도로 변해가고 있으며, 부지불시간에 유가등급과 같이 변화된 환경에 놀라는 시기가 곧 도래할 것이다. 오랜 기간 에너지 및 친환경 관련 요소기술의 개발, 정부의 지원제도 확대, 보급 강화 등 각종 노력을 통해 이제는 건축 설계분야에서도 친환경건축물에 대한 저변이 크게 확대되었다고 볼 수 있다. 하지만 실상 우리주변에서 제대로된 친환경 건축물을 실제로 보고자 한다면 두손으로 꼽기도 힘들 정도인 사실에 놀라게 될 것이다. 이러한 배경하에 이번 연재에서는 그동안 오랜기간 떠들고 노력했음에도 불구하고 실제 제대로된 친환경 건축물을 우리 주변에서 찾기 힘든 이유를 건축실무자 측면에서 재고해 보고, 이에 대한 새로운 해결방안을 모색해 보는 계기를 갖고자 한다. 특히 많은 친환경 건축기술 중 최근 선진국을 중심으로 가장 큰 이슈가 되어 있고, 또한 건축사 입장에서 쉽게 접근하기 어려운 기술분야인 신재생에너지 건축응용 측면에서 다양한 최신 기술 및 실질적 접근방법과 사례를 주제별로 제시하고자 한다.

  • PDF

Effect of Hydrophilic Polymer on Early Stages of Plant Growth of Euonymus fortunei 'Emerald and Gold' and Hedera japonica in a Vertical Greenery System for Low Maintenance (저관리 용기일체형 벽면녹화에서 황금줄사철과 송악의 초기활착에 미치는 친수성 중합체의 효용성)

  • Ju, Jin-Hee;Kim, Hea-Ran;Xu, Hui;Kim, Won-Tae;Choi, Eun-Young;Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.3
    • /
    • pp.1-9
    • /
    • 2016
  • The objective of this study was to exam early stages of plant growth of Euonymus fortunei 'Emerald and Gold' and Hedera japonica grown in fabric felt bag attached on vertical greenery system with the ratio of hydrophilic polymer to substrate, 0(referred as Control), 0.1, 0.2, or 0.4% (v/v), in order to effectively utilize rainfall for low maintenance. After rainfall, the increase in volumetric water content of substrate amended with the hydrophilic polymer was between 13% and 87%, compared to that in Control. During drought period, higher ratio of hydrophilic polymer to substrate slowly decreased the volumetric water content, and increased plant height, leaf length, leaf width, number of leaves, branch number, and stem diameter of both Euonymus fortunei 'Emerald and Gold' and Hedera japonica with the highest fresh and dry weights of shoots or roots under the 0.1% ratio of hydrophilic polymer.

Generation characteristics of transparent BIPV module according to temperature change (건물일체형 투명 모듈의 온도 변화에 따른 발전 특성)

  • Park, Kyung-Eun;Kang, Gi-Hwan;Kim, Hyun-Il;Yu, Gwon-Jong;Jang, Dae-Ho;Lee, Moon-Hee;Kim, Jun-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.210-211
    • /
    • 2007
  • Amid booming PV(photovoltaic) industry, BIPV(Building Integrated PV) is one of the best fascinating PV application technologies. To apply PV in building, variable factors should be reflected such as installation position, shading, temperature effect and so on. Especially a temperature should be considered, for it affects both electrical efficiency of PV module and heating and cooling load in building. Transparent PV modules were designed as finished material for spandrels are presented in this paper. The temperature variation of the modules with and without air gap and insulation were compared and analyzed. The results showed that the module with air gap and insulation has a much larger temperature variation than another transparent module. The temperature of the module reached by 55degree C under vertical irradiance of lower 500$W/m^2$. And the temperature difference between these modules was about 15degree C. To analyze the output performance of module according to temperature variation, separate module was manufactured and measured by sun-simulator. The results showed that 1 degree temperature rise reduced about 0.45% of output power.

  • PDF

Operational Characteristics in integrated Three-Phase a Flux-Lock type SFCL according to Fault Conditions (3상 일체화된 자속구속형 전류제한기의 동작특성)

  • Lee, Na-Young;Choi, Hyo-Sang;Jeong, Soo-Bok;Lee, Sang-Il;Nam, Gueng-Hyun;Lim, Sung-Hun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.467-470
    • /
    • 2006
  • Superconducting fault current(SFCLs) are expected to improve not only reliability but also stability of real power systems. The analysis on the single line-to-ground fault current of the integrated three phase flux-lock type SFCL, which consists of three flux-lock reactor wound on an iron core in each single phase and three YBCO thin films, was investigated in current limiting operating characteristics. We compared additive polarity winding with the subtractive one in the flux lock reactor. Its turns ratio each phase between the primary and the secondary coils is 63:42. When a single line-to-ground fault occurred in any phase, the peak value of line current in the fault phase of the additive polarity winding increased up to 31.44[A] during first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to 81.77[A] under the same conditions. This is because the current flow between the primary and the secondary windings becomes to be additive or subtractive in each winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to ground fault.

  • PDF