• Title/Summary/Keyword: 일정열유속

Search Result 72, Processing Time 0.028 seconds

Effects of Vertical Eddy Viscosity on the Velocity Profile - Cases of Given Vertical Eddy viscosity - (鉛直 過粘性係數가 流速의 鉛直構造에 미치는 影響 - 鉛直 過粘性係數가 주어진 境遇 -)

  • 이종찬;최병호
    • 한국해양학회지
    • /
    • v.29 no.2
    • /
    • pp.119-131
    • /
    • 1994
  • Vertical structures of wind-driven and tidal currents in a rectangular shaped uniform-depth basin of homogeneous water have been investigated using a mode-splitted, multi-level grid-box, hydrodynamic numerical model. The model was verified using analytical solutions for various vertical eddy viscosity profiles such as: a constant eddy viscosity, a linearly decreasing or increasing variation with depth, a quadratic variation with depth and an exponential variation with depth. Particular attention has been paid on the effects of "near-surface wall layer" on vertical shear of velocity. In numerical calculations, the whole water depth was divided into 13 levels with an unequal grid spacing. the model satisfactorily reproduces the velocity profile, but in case the eddy viscosity decreases rapidly with depth as in quadratical or exponential variation with depth, the vertical gradient of velocity near the bottom became very steep, and analytical solutions and numerical results showed some discrepancy. The vertical structures of horizontal velocity vary with both the depth-averaged value of eddy viscosity and its profiles. the velocity near the sea surface and near the bottom responded sensitively to the eddy viscosity of wall layer. For wind-driven current, the strong velocity shear was generated near the sea surface as eddy viscosity near the surface became small. For tidal current, the velocity above the sea bottom layer was almost constant regardless of the profiles of vertical eddy viscosity, but velocity in the sea bottom layer showed strong shear as eddy viscosity became small.

  • PDF

최대밀도점 부근의 순수물속에서 균일 열유속을 갖는 수직 원기둥에 의한 자연대류 -수치해석-

  • 추홍록
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 1997.11a
    • /
    • pp.223-228
    • /
    • 1997
  • 밀도가 온도의 변화에 따라 비선형적으로 변하는 경우, 예를 들어 공업적으로 많이 이용되고 있는 저온의 물인 경우에는 $4^{\circ}C$부근의 최대밀도점의 존재로 인해 매우 특이한 유동형태 및 열전달 특성이 나타난다. 또한 유체와 접하는 고체면이 평판의 경우와는 달리 어떤 일정의 곡률을 가지는 원기둥일 경우에는 곡률반경의 효과에 대한 특성이 고려되어야 한다. 이러한 현상은 공업적 측면뿐만 아니라 자연환경의 변화 등에서 매우 중요한 의미를 갖는다. (중략)

  • PDF

핵연료 봉다발에서의 국소열전달 특성 해석

  • 이중섭;정장환;오광석;김선철;유성연
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.391-396
    • /
    • 1996
  • 내부부수로, 벽면부수로, 모서리부수로를 포함하는 가압경수로형 원자로의 핵연료집합체를 모의하는 3$\times$3 봉다발을 모델로 수치해석을 통해 봉다발 주변의 유동특성을 알아보고 각 봉에서의 원주방향 위치에 따른 국소열전달 특성에 관해 고찰하였다. 봉다발에서 열전달계수의 분포는 벽면영향으로 인한 각 부수로에서의 유속분포와 밀접한 관계가 있으며 내부부수로에 인접한 봉에서 가장 높았고, 그 다음이 벽면부수로, 모서리부수로에 인접한 봉에서는 가장 작게 나타났다. 현재 핵연료의 열수력 설계시에 적용하고 있는 부수고 내의 모든 열수력학적 변수가 일정하다고 가정하는 부수로 해석방법은 봉다발내의 실제 열전달 현상과는 상당한 차이가 있음을 보여주었다.

  • PDF

Modeling of thermal fluidized desorption for diesel-oil contaminated soils (Diesel-oil에 오염된 토양의 유동상 열탈착 모델링)

  • 이상화;김병욱;이상득;박달근;이중기
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.137-147
    • /
    • 1999
  • Fluidized-bed thermal desorber coupled with a heat pipe was investigated for the remediation of soil contaminated with diesel oils. Thermal gravimetric analysis by Cahn-balance indicated that the desorption of diesel oils from the soil particles was mainly governed by the internal diffusion at low concentration of less than 0.5 wt. % of oils in the soil particles. In fluidized-bed experiments. increase of fluidizing gas velocity reduced the residual oils of the contaminated soils, the increase of soil feed rate decreased efficiency of fluidized-bed desorber. A mathematical model was developed by incorporating Fickian diffusion kinetics into the Kunii-Levenspiel model Simulation results showed reasonable agreement for the performance of fluidized-bed thermal desorber.

  • PDF

Experimental study of natural transition in natural convection boundary layer (자연대류 경계층의 천이특성에 대한 실험적 연구)

  • Huang, ShengZhong;Yousif, Mustafa Z.;Lim, Hee-Chang
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.1
    • /
    • pp.29-37
    • /
    • 2022
  • We carried out a laboratory experiment about the thermo-fluidic characteristics of natural convection boundary layer over a vertical heated plate under constant heat flux condition. Particle image velocimetry has been applied to observe the surface convection velocity close to the vertical plate submerged in the water chamber with the condition of Ra = 7 × 109 and Pr = 8.1. The velocity distributions indicate that the distinct stripe-like structures appears in the upstream (earlier transition region) and the distinct negative-positive and Λ(λ)-shaped flow structures in the downstream (mid-transition region). In addition, the temporal variation of spanwise and streamwise velocity is also presented.

PlV Measurement of Channel Cavity Flow with Bottom Heat surface of Constant Heat Flux (일정 열유속의 하부 가열면을 갖는 채널캐비티 내부유동의 PIV 계측)

  • 조대환;김진구
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.437-442
    • /
    • 1997
  • An experimental study was carried out in a channel cavity with square heat surface by visual¬ization equipment with Mach - Zehnder interferometer and laser apparatus. The image processing system consists of one commercial image board slit into a personal computer and 2-dimensional sheet light by Argon-Ion Laser with cylindrical lens and flow picture recording system. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system which adopted two¬frame grey-level cross correlation algorithm. Heat source was uniform heat flux(o.4W/cm$^2$, , O.8W/cm$^2$, 1.2W/cm$^2$). Obtained result showed various flow patterns such as kinetic energy distribution. Severe unsteady flow fluctuation within the cavity are remarkable and sheared mixing layer phenomena are also found at the region where inlet flow is collided with the counter-clockwise rotating main primary vortex. Photographs of Mach ~ Zehnder are also compared in terms of constant heat flux.

  • PDF

An Experimental Study on Convection Heat Transfer in an Oscillating Flow of a Heater Tube for Stirling Cycle Machines (스터링 사이클기기용 가열기 원관내부 왕복유동에서의 열전달에 관한 실험적 연구)

  • 강병하;이건태;이춘식;이재헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.6
    • /
    • pp.1547-1555
    • /
    • 1993
  • An experimental study on convection heat transfer characteristics from a heated tube to an oscillating flow has been carried out, . This problem is of particular interest in the design of heat exchangers in Stirling cycle machines. Experimental system has been developed to measure temporal variations of temperature inside a heater tube during oscillating modes in a Stirling cycle machine. The dependence of temperature distributions and heat transfer rates on the oscillating frequency as well as the swept volume ratio and the mean pressure of a Stirling cycle machine is investigated in detail. The experimental results indicate that the measured temporal variations of temperature become nearly sinusoidal. The amplitude of temperature variation in the core of the tube is much more substantial than that near the tube wall, whereas the reverse is true for pulsating flows. It is also found that the heat transfer rate is increased significantly as the oscillating frequency or oscillating amplitude or the mean pressure in a tube is increased.

A Combustion Characteristic Analysis of Quercus Variabilis and Pinus Densiflora Fallen Leaves Using Radiation Heat Flux (복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석)

  • Park, Hyung-Ju;Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • The combustion characteristics of surface forest fire fuels was analysed using variable external irradiation level. The characteristics such as ignition time, ignition temperature, critical heat flux and mass loss rate were measured. Fuel samples were exposed to incident heat fluxes from 8 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen holder was $100\;mm{\times}100\;mm{\times}12\;mm$ and the fuel samples grinded by electric mill were the fallen leaves of Quercus variabilis and Pinus densiflora. As results, the occurrence of ignition is possible to the heat flux more than $9\;kW/m^2$. The fuel of Pinus densiflora keeps its high temperature longer than that of Quercus variabilis during the combustion process. The results of measurement shows that the maximun and average mass loss rate of Quercus variabilis larger than that of Pinus densiflora.

Turbulent Heat Transfer in Rough Concentric Annuli With Heating Condition of Constant Wal Heat Flux (일정벽면열유속의 가열조건의 갖는 거친 동심환형관내의 난류열전달)

  • 손유식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.54-61
    • /
    • 1999
  • The fully developed turbulent momentum and heat transfer induced by the roughness elements on the outer wall surfaces in concentric annuli are analytically studied on the basis of a modified turbu-lence model. The resulting momentum and heat transfer are discussed in terms of various parame-ters such as the radius ratio the roughness density Reynolds number and Prandtl number accord-ing to the heating condition. The study shows that certain artificial roughness elements may be used to enhance heat transfer rates with advantage from the overall efficiency point of view.

  • PDF

유도 결합 플라즈마원의 외부 냉각에 관한 수치 모델링

  • Ju, Jeong-Hun;Jo, Jeong-Hui;Park, Sang-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.218-218
    • /
    • 2016
  • 실린더 형태의 유전체 관에 나선형으로 도전체 안테나를 설치하는 타입의 유도 결합 플라즈마원은 간단한 구조로 화학 조성 분석용부터 나노 분말 제조, 반도체용 식각/증착, 표면 처리, 자동차 및 일반 산업 부품용 증착 보조원등으로 널리 사용되고 있다. 고밀도 라디칼/이온의 공급을 위해서 투입 전력을 증가시키는 경우 높은 전력 밀도로 인해서 유전체 관에 인가되는 열응력이 대기압 및 관 고정용 구조물에 의한 구조 응력에 더해져서 파손에 이르는 경우가 발생될 수 있다. 실제 실린더 길이 전체를 안테나 코일로 감는 경우에도 플라즈마 발생 밀도가 높은 지역은 중심 일부 영역에 국한 되는 공정 영역도 있어서 이에 대한 분석이 필요하다. CFD-ACE+를 이용하여 플라즈마의 생성, 냉각수의 열전도, 외부 공냉식 팬의 역할등에 대해서 수치 모델을 작성하여 검토하였다. 나선형 냉각코일의 경우 냉각수량을 일정값 이상으로 증가시키는 경우 유속이 지나치게 빨라져서 열원이 있는 내경쪽 표면에서 열전도가 유속에 비례해서 증가하지 못하는 단점이 발생할 수 있으며 냉각팬의 경우 일반적으로 장치 내부에 대해서만 모델링을 하는 데 실제로 전체 시스템의 주변에서 공기의 흐름을 넓게 해석해야 실제 냉각 효과를 파악할 수 있다. 심한 경우 냉각용 공기 흡입구와 토출구의 간격이 좁아서 열원에 의해서 가열된 공기의 상당량이 다시 냉각용 공기 흡입구로 재순환 되는 경우도 발생하기 쉽다.

  • PDF