• Title/Summary/Keyword: 일반촬영

Search Result 606, Processing Time 0.027 seconds

Accuracy of Parcel Boundary Demarcation in Agricultural Area Using UAV-Photogrammetry (무인 항공사진측량에 의한 농경지 필지 경계설정 정확도)

  • Sung, Sang Min;Lee, Jae One
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.34 no.1
    • /
    • pp.53-62
    • /
    • 2016
  • In recent years, UAV Photogrammetry based on an ultra-light UAS(Unmanned Aerial System) installed with a low-cost compact navigation device and a camera has attracted great attention through fast and accurate acquirement of geo-spatial data. In particular, UAV Photogrammetry do gradually replace the traditional aerial photogrammetry because it is able to produce DEMs(Digital Elevation Models) and Orthophotos rapidly owing to large amounts of high resolution image collection by a low-cost camera and image processing software combined with computer vision technique. With these advantages, UAV-Photogrammetry has therefore been applying to a large scale mapping and cadastral surveying that require accurate position information. This paper presents experimental results of an accuracy performance test with images of 4cm GSD from a fixed wing UAS to demarcate parcel boundaries in agricultural area. Consequently, the accuracy of boundary point extracted from UAS orthoimage has shown less than 8cm compared with that of terrestrial cadastral surveying. This means that UAV images satisfy the tolerance limit of distance error in cadastral surveying for the scale of 1: 500. And also, the area deviation is negligible small, about 0.2%(3.3m2), against true area of 1,969m2 by cadastral surveying. UAV-Photogrammetry is therefore as a promising technology to demarcate parcel boundaries.

LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS (대구치에서 회전식 NiTi file의 수명과 파절양상)

  • Kim, Jin-Woo;Ahn, Byung-Doo;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.184-192
    • /
    • 2005
  • Intracanal separation of the rotary files is a serious concern in modern endodontic practice. The objective of this study was to compare the life span and fracture patterns of three NiTi rotary files in molar teeth Mesiobuccal roots of upper molar (n = 150) and mesial roots of lower molar (n = 150) were divided into three groups and each group was prepared with Profile, ProTaper, and K3 respectively. Every file was used until separation and/or deterioration of the cutting blade was happened, and then the number of canals to separation and/or unwinding were recorded. Radiographs and Scanning electon microscope (SEM) photographs were taken to evaluate the patterns of separation. The results were as follows: 1. There were no significant differences in numbers of canals to separation and/or unwinding among the groups. 2. Comparing between flaring files, K3 showed significant lower numbers of canals to separation and/or unwinding (p < 0.05), and there was no significant difference between shaping files 3. Separations of instruments were occurred at the midpoint of curvatures within the canals 4. In SEM observations, ductile fractures were seen in most of cases, characterized by shallow dimples. Additional researches is needed to provide a new guideline that informs the appropriate number of times to use NiTi files.

The Affecting Factor to Magnification Ratio from Alveolar Crest To Inferior Mandibular Canal in Diagnosis of Implant Site of Mandibular Molar Region with Panoramic Radiography (파노라마방사선사진에서 하악 구치부의 임플란트 매식부위 평가시 치조정-하악관간 거리의 확대율에 영향을 미치는 요소에 관한 연구)

  • Jung, Jae-Jin;Choi, Sang-Mook;Lee, Yong-Moo;Ku, Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.31 no.4
    • /
    • pp.811-822
    • /
    • 2001
  • 최근 임플란트를 원하고, 필요로 하는 환자가 증가하면서 술전의 정확한 진단이 보다 중요해졌고 다양한 진단방법이 소개되고 이용되어져 왔다. 그 중 보편적으로 가장 널리 사용되어지는 방법이 방사선 촬영법이고 그 중에서도 파노라마방사선사진이다. 하지만 파노라마방사선사진의 용이함과 간편성에도 불구하고 그 방법 자체가 가지고 있는 한계점 때문에 CT/MPR(Computer Tomography/Multiplanar Reformatting)이 일부 환자에서는 반드시 필요하다는 주장이 대다수이다. 본 연구의 목적은 하악 구치부에 임플란트 시술을 받은 환자를 대상으로 파노라마방사선사진의 확대율을 알아보고 파노라마방사선사진과 CT/MPR에서 치조정-하악관간 거리가 실제 어느 정도 차이를 보이는지, 그리고 CT/MPR에 대한 파노라마방사선사진의 확대율에 환자의 하악골의 경사도와 하악관의 해부학적 위치가 어떤 영향을 미치는지를 알아보는 것이다. 본 연구는 서울대학 치과병원 치주과를 내원하여 하악구치부에 Dental Implant 시술을 받은 15명의 환자, 32개 부위를 대상으로, 임플란트 시술을 위한 술전 파노라마방사선사진과 CT/MPR, 술후의 파노라마방사선사진, CT/MPR상을 자료로, 임플란트가 식립될 위치에서 치조정에서 하악관의 길이, 하악골의 협설폭경, 하악골의 설측면에서 하악관의 수평길이, 임플란트 매식체의 설측에서 하악관까지의 수평거리를 계측하였고 이 해부학적 계측치들이 CT/MPR에 대한 파노라마방사선사진의 확대율과 어떤 상관관계에 있는지 Pearson's correlation coefficient test를 이용해 살펴보았다. 1. CT/MPR에 대한 파노라마방사선사진의 확대율은 CT/MPR상에서 하악골 단면의 협설폭경(Pearson test에서의 상관관계 분석시, 상관계수 r=-0.604), 임플란트 매식체의 설측에서 하악관까지의 수평거리(r=-0.515), 하악골의 설측면에서 하악관까지의 수평거리(r=-0.640)와 뚜렷한 음적 선형관계가 있었다. 2. CT/MPR에 대한 파노라마방사선사진의 확대율은 CT/MPR상에서 하악골의 장축의 각도와는 뚜렷한 양적 선형관계(Pearson test에서의 상관관계 분석시, 상관계수 r=-0.446)가 있었다. 3. 여러 요소중 CT/MPR에 대한 파노라마방사선사진의 확대율과 가장 유의성있는 연관성을 보이는 것은 CT/MPR상에서 하악골의 설측면에서 하악관까지의 수평거리였다(r=-0.640) 4. CT/MPR에 대한 파노라마방사선사진의 확대율은 일반적으로 생각되어지는 파노라마방사선사진의 확대율 125%보다 큰, 약 135%로 나왔다. 이상의 결과로 볼 때, 하악골의 설측면에서 하악관까지의 수평거리가 CT/MPR에 대한 파노라마방사선사진의 확대율에 가장 영향을 미치는 요소로 추정되며 확대율은 125%보다 높은 것으로 나타났다.

  • PDF

Breast cancer screening rates-related factors Korea women ever considering area environmental characteristics: The fourth Korea National Health and Nutrition Examination Survey(KNHANES IV) (지역 환경적 요인이 한국 여성의 유방암 조기검진 수검률에 미치는 영향 : 국민건강영양조사 제 4기를 중심으로)

  • Lee, Mi-Hwa;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.437-449
    • /
    • 2014
  • In this study, we analyzed an effect of area-environmental factor on breast cancer screening rates using multi-level analysis. It was intended for the KNHANES-IV. Total subjects were 14338. Among them, 4143 subjects met the inclusion criteria. When we applied only empty Model, a variance of breast cancer screening rates was 0.061 in each region. When we applied Model with individual level variables, the variance was 0.034. However, when we applied both Model with individual level variables and Model with area level variables, the variance was 0.023. We drew applied only individual level variables parallel applied 3 regional variances which could explain variance of inspection of breast cancer up to 18.04% compared with applied only individual level variables. Area level variables could reduce a variance of region. This means besides individual level variables. The group can share a same thing and can effect to breast cancer screening rates. We need to discover factors which area level variables and suggest that make a standard for inspection of breast cancer.

Synthesis of New Black Pigment; Carbon Black Pigment Capsulated into the Meso-pore of Silica as Black Pigment in Cosmetic (새로운 Black Color의 합성;화장품에서 블랙 색소로서 Meso-pore Silca에 캡슐레이션된 Carbon-black Silica)

  • Hye-in, Jang;Kyung-chul, Lee;Hee-chang , Ryoo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.189-195
    • /
    • 2004
  • Carbon black have not been used as pigment material in cosmetic because of very low density and dispersity, but carbon black have applicable character as black pigment because of non-toxic, stable physico-chemical property, and black colority. In this study, mesoporous silica samples were synthesized by sol-gel reaction using surfactants-template method; TEOS (tetraethoxysilane) - a) PEO/lecithin, b) PEO/polyethylene glycol, c) lecithin/polyethylene glycol in ethanol/water solution. Synthesized organic-inorganic hybrid - silica were heat-treated in N2 condition at 500$^{\circ}C$. Mesoporous silica with black carbon in pore have the effective density and show the good dispersity in both hydrophilic and hydrophobic solvent. Properties of the samples were measured; specific surface area (750㎡/g) and pore size (4-6nm) using BET, pore structure (cylindrical type) using XRD, morphology (spherical powder with 0.1-0.5$\mu\textrm{m}$ partical size) of the samples using SEM. Carbon-silica black color applied to mascara, it shows a dark black colority and good dispersity as compared with the general black color titania pigment. Moreover, it is possible to control the density of black color pigment because it is possible to control pore volume and particle size of mesoporous silica properly. It show the good volume effects in mascara. That is why possible to apply all kinds of cosmetic products.

A study on measurement of the pollution levels and disinfection of medical radiation shielding for lead apron (의료방사선 차폐용 납 가운의 오염도 측정 및 소독에 관한 연구)

  • Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.490-497
    • /
    • 2016
  • This study compared and analyzed the pollution levels of radiation shielding aprons and ways to sterilize them using 30 lead aprons. After collecting samples from the center of the lead apron, where contact is most frequent, experiments were conducted employing Coagula and Latex methods. Using the culture medium where bacteria grew, measurements of the pathogen count and identification were performed. The greatest number of pathogens were $7.16{\pm}10$, which were detected on the lead apron from general X-ray room #2, but there was no significant difference according to the facilities (p > 0.05). Compared to how many pathogens remained between using the disinfectant ethanol and tissue, the pathogens decreased by $0.01{\pm}0.4$ (p < 0.05) after using disinfectant ethanol and by $0.87{\pm}1.7$(p < 0.05) after using disinfectant tissue. The Pearson correlation test revealed a significant correlation (-0.296, p < 0.05) between them. According to this research, there were pathogens on the lead aprons and the number of pathogens was determined by statistical analysis. It is expected that the rate of radiology technologists, patients, and medical equipment infected by pathogens will be reduced by the proper use of sterilization with a disinfectant ethanol.

Effects on Patient Exposure Dose and Image Quality by Increasing Focal Film Distance in Abdominal Radiography (복부 일반촬영시 초점-필름간거리 변화가 피폭선량 및 화질에 미치는 영향)

  • Kim, You-Hyun;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • We can and must improve the diagnostic images using available knowledge and technology. At the same time we must strive to reduce the patient's integral and entrance radiation dose. Reducing the integral dose to the patient during the radiologic procedure is a primary concern of the patient, especially the pediatric patient, the radiologist and the technologist. A 100cm focal film distance generally is used for most over-table radiography. The early x-ray tubes and screen film combinations required long exposures, which often resulted in motion artifacts. But nowaday, we have the generators and x-ray tubes that can deliver the energy necessary in a very short time and the receptors that can record the information just as rapidly. And, we performed this studies to evaluate the patient exposure dose and the image quality by increasing focal film distance in diagnostic radiography. There are many factors which affected to exposure factor, but we studied to verify of FFD increase, only. Effect of increasing the focal film distance to a 140 cm distance was tested as follows; 1. The focal film distances were set at 100, 120, and 140cm. 2. A 18cm acryl(tissue equivalent) phantom was placed on the table top. 3. An Capintec 192 electrometer with PM 05 ion chamber was placed at the entrance surface of the phantom, and exposure were made at each focal film distances. 4. The procedure was repeated in the same manner as above except the ion chamber was placed beneath the phantom at the film plane. 5. Exit exposure were normalize to 8mR for each portions of the experiment. Based on the success of the empirical measurements, a detailed mathematical analysis of the dose reduction was performed using the percent depth dose data. The results of this study can be summerized as followings ; 1) Increasing FFD from 100 cm to 140 cm, we would create a situation that would have a significant effect on the overall quality of radiograph and achive the 17.42% reduction of entrance dose and the 18.95% reduction of integral dose that the patient receives. 2) Thickness of Al step wedge for equal film density increased with the long distance. 3) Increasing FFD, Magnification of image was lowered. 4) Resolution of image also increased with the FFD. As the results described above, we strongly recommend using the long FFD to provide better information for our patients and profession in abdomen radiographic studies.

  • PDF

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

Study on Companion Dog Practice and Management System on Animal Hospital in Seoul City (서울시내 동물병원의 애완견 진료와 관리시스템에 관한 연구)

  • Kang, Dong-Joon;Chung, Byung-Hyun;Heo, Jung;Kang, Chung-Boo
    • Journal of agriculture & life science
    • /
    • v.43 no.2
    • /
    • pp.39-46
    • /
    • 2009
  • Ten animal hospitals in Seoul were selected, and of which 41,305 practice in total for recent 1 year were analyzed based on international classification of disease(ICD) of WHO. Of the entire practice, prophylaxis cases accounted for 42.2%. Of the 9,376 cases of internal diseases, digestive system diseases accounted for 4,957 cases(52.9%), respiratory system diseases 1,776 cases(18.9%), circulatory system diseases 1,239 cases(13.2%), and neoplasms diseases 413 cases(4.4%), respectively. In the estate investment expenses, to be specific, rental guarantee deposit accounted for about 50% of the entire estate cost, foregift(48%), and monthly rent(2%). Dividing the income of animal hospitals into medical service, articles selling, and pet-dog beauty, medical service accounted for 71.6% of the entire sales, selling of articles 16.7%, and pet-dog beauty 11.6%. Publicity work for the animal hospital was done mostly through web sites on internet(47%), then through local advertising papers(23.5%), and through bulletins and telemarketing(11.8%). Manpower of the animal hospitals in this study was mostly composed of veterinarians(45.5%) up to about half of the entire staffs, while there was no veterinary technician who had specialized education in that area.

A Photovoice Study of Social Relationships among Adolescents with Intellectual Disabilities (지적장애 청소년의 사회적 관계에 관한 포토보이스 연구)

  • Kim, Min Ah;Heo, Il Kwon;Jung, Sang Mi;Seo, Jung A
    • Korean Journal of Social Welfare Studies
    • /
    • v.48 no.2
    • /
    • pp.5-33
    • /
    • 2017
  • This study explored challenges and desires related to social relationships among adolescents with intellectual disabilities, using the photovoice method. Six adolescents with intellectual disabilities (M = 18.33 years) who are attending a general high school participated in 7 sessions of a photovoice program. They selected themes related to social relationships through group discussions and shared their photos related to the themes with other participants. Our study yielded 15 subthemes within 5 social relationships (peers, teachers, boyfriends/girlfriends, parents, persons whom I need) from adolescents with intellectual disabilities as follows: relationships with peers (feeling lonely and left out, being teased and bullied by peers, making efforts to fix damaged relationships with friends), relationships with teachers (feeling appreciated by teachers who understand me, lacking interactions with teachers, wanting teachers to show they care about my school life), relationships with boyfriends/girlfriends (wanting to have a boyfriend/girlfriend, feeling worried and fearful about having a boyfriend/girlfriend, trying to attract a boyfriend/girlfriend), relationships with parents (being thankful to parents for their unconditioned love, enjoying time with parents, feeling bad because of not being close to father), persons whom I need (persons who enjoy spending time with me, persons who help me, persons who never give up on me). This study provides implications for social work practice, such as training for improving peer relationships and coping with peer conflict, education for fostering healthy romantic relationships, training for promoting social skills of adolescents with intellectual disabilities, and education for increasing awareness of the social needs of students with intellectual disabilities among peers without disabilities, teachers, and social workers.