• Title/Summary/Keyword: 일반촬영장비

Search Result 57, Processing Time 0.039 seconds

Analysis of Bacterial Contamination on Surface of General Radiography Equipment and CT Equipment in Emergency Room of Radiology (영상의학과 응급실내의 일반촬영장비와 전산화단층촬영장비 표면에서의 세균 오염에 관한 분석)

  • Hong, Dong-Hee;Kim, Hyeong-Gyun
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.421-427
    • /
    • 2016
  • We aim to offer basic materials about infection management through conducting bacterial contamination test about general radiography equipment and CT equipment installed in ER of three general hospitals with 100 sickbeds or more located in Gyeongsangbuk-do Province, and suggest management plan. It had been conducted from 1st December 2015 to 31st December, and objects were general radiography equipment and CT equipment of emergency room located in Gyeongsangbuk-do Province. For general radiography equipment, sources were collected from 4 places such as upper side of control box which employees use most, upper side of exposure button, whole upper side of table which is touching part of patient's skin, upper side of stand bucky's grid, and where patients put their jaws on. For CT equipment, sources were collected from 3 places such as upper side of control box which radiography room employees use most, X-ray exposure button, whole upper side of table which is touching part of patient's skin, and gantry inner. Surface contamination strain found at general radiography equipment in emergency room of radiology are Providencia stuartii(25%), Stenotrophomonas maltophilia(18%), Enterobacter cloacae(8%), Pseudomonas species(8%), Staphylococcus epidermidis(8%), Gram negative bacilli(8%), and ungrown bacteria at incubator after 48 hours of incubation (67%) which is the biggest. Most bacteria were found at upper side of stand bucky-grid and stand bucky of radiology's general radiography equipment, and most sources of CT equipment were focused at patient table, which means it is contaminated by patients who have various diseases, and patients who have strains with decreased immunity may get severe diseases. Thus infection prevention should be made through 70% alcohol disinfection at both before test and after test.

Analysis of Healthcare Convergence on Bacterial Contamination of Radiological Equipment in Emergency Rooms of General Hospitals (종합병원 응급실내의 영상의학과 장비에서의 세균 오염에 관한 보건학적 융합 분석)

  • Hong, Dong-Hee;Park, Mi-Soon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.1
    • /
    • pp.51-59
    • /
    • 2017
  • It is to establish preliminary data about healthcare convergencr of infection control by performing a bacterial contamination test for CT scanner as well as general radiographic systems in the emergency rooms of general hospitals. The period was December 1 ~ December 31, 2015. It is detect in the emergency rooms of 7 medical facilities including 2 in Seoul, and 1 in Gyeonggi-do Province, and 2 in Jeonla-do Province, and 2 in Chungcheong-do Province. The surface contamination strains detected from CT scanner in the radiology department emergency rooms were Micrococcus species(4,5%), Stenotrophomonas maltophilia(9%), Enterococcus faecium(4.5%), Providencia stuartii(4.5), and Gram negative bacilli(4.5%). Also, the surface contamination strains detected from general radiographic system in the radiology department emergency rooms were Providencia stuartii(11%), Klebsiella pneumonia(3.5%), Stenotrophomonas maltophilia(11%), Pantoea species(11%), Acinetobacter baumannii(3.5%), Micrococcus species(3.5%), Escherichia coli(3.5%), Enterobacter species(3.5%), and Gram negative bacilli(11%). Considering that the regions of most detection were all the places closely related to patients, radiologists would have to thoroughly clean with alcohol before and after a test.

National Data Analysis of General Radiography Projection Method in Medical Imaging (영상의학검사 일반촬영 분야의 촬영기법에 대한 분석)

  • Kim, Jung-Su;Kim, Jung-Min;Lee, Young-Han;Seo, Deok-Nam;Choi, In-Seok;Nam, So-Ra;Yoon, Yong-Su;Kim, Hyun-Ji;Min, Hye-Lim;Her, Jea;Han, Seong-Gyu
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.169-175
    • /
    • 2014
  • According to database of medical institutions of health insurance review & assessment service in 2013, 1118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

A Study of the gimbal system control unsing the Intelligent PID (지적 PID를 이용한 짐벌시스템 제어 연구)

  • Kim, Min;Byun, Gi-Sig;Kim, Gwan-Hyung;Choi, Myoung-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.99-100
    • /
    • 2016
  • 드론이나 이동형 촬영장비에 장착된 카메라로부터 깨끗하고 안정된 영상을 획득하기 위해서는 짐벌시스템의 안정화기 설계가 필요하다. 짐벌시스템은 카메라 모듈을 지지하는 구조와 외부로 부터의 진동을 차단하면서 정확한 각도를 추종하는 안정화기로 구성된다. 이동형 촬영장비나, 비행중인 드론에는 매우 다양한 주파수 성분의 진동이 발생되는데, 이러한 진동을 제어하기 위하여 6자유도 운동방정식을 유도하고, 이 중에서 본 논문에서는 일반적으로 rolling, pitching, yawing 운동에 대해서는 PID 제어기를 사용하여 안정화를 제어하기만, 카메라종류나 짐벌시스템 구조가 바뀔 때 마다 PID 파라미터를 변경해야 되는 경우가 빈번하다. 본 논문에서는 이런 문제점을 개선하기 새로이 제기된 제어 기법인 지적 PID(intelligent PID) 제어를 통하여 진동제어를 수행하여 짐벌시스템의 안정화를 위한 제어기법을 제안하고자 한다.

  • PDF

Peer Review of Teleradiology at a Teleradiology Clinic: Comparison of Unacceptable Diagnosis and Clinically Significant Discrepancy between Radiology Sections and Imaging Modalities (원격판독 의료기관에서 시행한 원격판독의 동료평가: 세부전공분야와 촬영장비에 따른 판독 불일치 정도와 불일치 판독의 임상적 의의 비교)

  • Hyung Suk Seo;Jai Soung Park;Yu-Whan Oh;Dongwook Sung;A Leum Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1545-1555
    • /
    • 2021
  • Purpose The purpose of this study was to evaluate the rates of unacceptable diagnosis and clinically significant diagnostic discrepancy in radiology sections and imaging modalities through a peer review of teleradiology. Materials and Methods Teleradiology peer reviews in a Korean teleradiology clinic in 2018 and 2019 were included. The peer review scores were classified as acceptable and unacceptable diagnoses and clinically insignificant and significant diagnostic discrepancy. The diagnostic discrepancy rates and clinical significance were compared among radiology sections and imaging modalities using the chi-square test. Results Of 1312 peer reviews, 117 (8.9%) cases had unacceptable diagnoses. Of 462 diagnostic discrepancies, the clinically significant discrepancy was observed in 104 (21.6%) cases. In radiology sections, the unacceptable diagnosis was highest in the musculoskeletal section (21.4%) (p < 0.05), followed by the abdominal section (7.3%) and neuro section (1.3%) (p < 0.05). The proportion of significant discrepancy was higher in the chest section (32.7%) than in the musculoskeletal (19.5%) and abdominal sections (17.1%) (p < 0.05). Regarding modalities, the number of unacceptable diagnoses was higher with MRI (16.2%) than plain radiology (7.8%) (p < 0.05). There was no significant difference in significant discrepancy. Conclusion Peer review provides the rates of unacceptable diagnosis and clinically significant discrepancy in teleradiology. These rates also differ with subspecialty and modality.

A Method to reduce time of path planning optimization for AOI machines (AOI 검사기의 경로 계획 최척화 처리 시간 단축 방안)

  • Baek, Sunwoo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.518-519
    • /
    • 2016
  • AOI 검사기는 SMT 공정 상에서 PCB (printed Circuit Board) 상의 부품들을 카메라로 촬영하고 촬영된 영상을 2D 혹은 3D 형태의 이미지로 재구성하고 분석하여 이상 여무를 판단하는 장비다. 검사를 하고자 하는 PCB의 크기가 카메라가 촬영할 수 있는 영역 보다 큰 경우가 대부분이기 때문에 PCB 상에 마운트 되어 있는 부품들을 모두 촬영하기 위해서는 여러 차례 나누어 촬영해야 할 필요가 있으며 이 때문에 PCB 상에 촬영해야 하는 부품들을 가능한 FOV에 많이 포함될 수 있도록 여러 FOV 영역으로 나누고 이렇게 나누어진 FOV 영역들을 최적의 경로로 이동하며 촬영할 수 있도록 하기 위한 알고리즘이 필요하다. 기존 논문들은 대부분 이 문제를 해결하기 위한 알고리즘에 대해 다루어 왔다. 일반적으로 생산이 진행되는 시점에서는 검사해야 할 PCB에 대한 정보 (PCB의 크기, 부품의 위치, 크기, 종류 등)는 이미 정해져 있기 때문에 경로 계획 최적화 수행은 PCB 정보에 변동이 없다면 한차례만 하면 된다. 하지만 검사를 할 수 있도록 Teaching 하는 단계에서는 PCB 정보가 지속적으로 변경될 수 있으며 이에 따라 최적화를 여러 차례 수행해야 할 필요성이 있다. 최적화를 위한 처리 시간은 부품의 개수, PCB 상에서의 분포정도등에 따라 증가하기 때문에 PCB 정보가 변경될 때 마다 최적화를 수행하게 되면 비효율적으로 처리 시간이 증가하게 된다. 본 논문에서는 이 문제에 대해 연구하고 해결책을 제시하였다.

Implementation the residential CCTV system with internet router (무선 공유기를 이용한 가정용 CCTV 시스템 구현)

  • Ko, Joong-Sik;Chung, Se-Hoon;Kwak, Hu-Keun;Chung, Kyu-Sik
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2007.10d
    • /
    • pp.195-200
    • /
    • 2007
  • CCTV(Close Circuit Television)는 화상정보를 특정 목적으로 특정 사용자에게 전달해주는 시스템이다. 회사, 쇼핑몰 등 큰 규모의 건물부터 아파트, 개인 상점에 이르기까지 많은 분야에서 CCTV를 설치하여 건물 내외의 영상을 촬영하여 보안을 위해 사용한다. 하지만 기존의 CCTV 시스템을 설치하기 위해 필요한 장비가 고가이기 때문에 일반 가정에서 CCTV를 설치하여 사용하기에는 경제적 부담이 있다. 그리고 CCTV를 제어하고 영상을 저장하기 위한 장비의 전원을 계속 켜두어야 하기 때문에 CCTV 시스템의 유지 및 사용하는데 드는 비용도 비싸다는 단점이 있다. 이 문제점들을 해결하기 위해 본 논문에서는 일반 가정에서 많이 사용하는 무선 공유기와 웹 카메라를 사용해서 가정용 CCTV 시스템을 설치하는 방법을 제안하고 구현한다. 제안된 방법은 무선 공유기에 웹 카메라를 연결하여 CCTV 시스템을 구현하고, 움직임이 감지될 경우 SMS 서비스를 사용하여 사용자에게 경고 메시지를 전송함으로써 저렴한 비용으로 침입에 대한 즉각적인 대응을 할 수 있는 서비스를 제공하는데 목적이 있다.

  • PDF

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Color Image Compensation Method using Advanced Image Formation Model and Adaptive Filter (개선된 영상생성 모델과 적응적 필터를 이용한 칼라 영상 보정방법)

  • Choi, Ho-Hyung;Yun, Byoung-Ju
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.10-18
    • /
    • 2009
  • Color rendition method is necessary for improving the low contrast images which are achieved by PDA, mobile phone camera or PC camera. There are some methods for color rendition. However, after correcting the color, image quality degradations, such as graying-out, halo-artifact and color noise, may occur. In order to overcome these problems, this paper proposes a retinex-based color rendition method. The proposed method uses the HSV color coordinate system to avoid the graying-out, and the advanced image formation model to reduce the halo-artifact in which the image is divided into three components as the global illumination, the local illumination, and reflectance. The experiment results show that the proposed method yields better performance of color correction over the conveniently method.

Real-Time Vision-Based Virtual Advertisement System (영상기반 실시간 가상광고 시스템)

  • 박혁래;박종일
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.205-208
    • /
    • 2001
  • 최근 스포츠 중계를 중심으로 가상광고가 큰 주목을 받고 있다. 가상광고는 현실에 존재하지 않는 광고를 실영상 내에 삽입하여 마치 실제로 존재하는 물체처럼 보여주는 기술이다. 본 논문에서는 한 대의 카메라로 촬영한 영상으로부터 실시간으로 특징점 추출 및 추적을 행하여, 카메라 Projection 행렬을 복원하고, 이를 이용하여 범용적인 크로마키(chroma-key) 기법으로 영상합성 함으로써 센서와 같은 부가장비가 필요없는 영상기반의 가상광고 시스템을 구현하였다. 일반 PC상에서 알고리즘의 유효성과 실시간 동작성을 확인하였다.

  • PDF