A Study on the Emphasis of Human Tolerance in the Crash Event (추락과정에서의 인체 허용한도 중요성 연구)

  • Hwang, Jungsun;Lee, Sangmok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.740-746
    • /
    • 2013
  • Design with crashworthiness concept has been emphasized for almost aircraft and motor vehicles. However, crashes accompanied serious injury and death have been continuously occurred, and will be occurred subsequently. What was worse, it is a well-known fact that there were a good many crashes classified as survivable accidents in which fatal injuries were reported. But we cannot say that fatal injuries were inevitable consequences of those crashes. If crashworthy design for seat, restraint systems, and cabin strength were adequate or right, survivability in a crash event could be maximized greatly. To substantiate the right crashworthiness, we must thoroughly understand the characteristics of human tolerance under abrupt acceleration change, and the cabin design should be combined with proper use of energy absorbing technologies that reduce accelerations experienced by the occupants. In this paper, the emphasis on the human tolerance under abrupt accelerations as well as the necessity of change in design requirements for crash environment will be stressed to widen the belt of consensus for the right crashworthy design.

Research on emission test procedures and permissible standards of automobile exhaust gases (자동차배출가스 허용한도 및 검사방법)

  • 이문득;김준용;김응서
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.2 no.2
    • /
    • pp.31-39
    • /
    • 1980
  • 복지사회적 목표에서의 도시계획 및 교통문제는 환경보전의 측면에서 상충되는 관계가 이루어 지고 있다. 특히 대도시에서 자동차의 배출가스에 의한 대기오염은 매우 심각한 관계에 이르고 있다. 우리나라에서도 앞으로 급증할 것으로 예상되는 자동차 증가율과 상대적으로 협조한 도 로의 점유율 및 이에 따른 자동차 주행 pattern의 불규칙성을 감안하면 외국과 같은 규제기준의 설정이 필요하다. 자동차 배출가스에 의한 대기오염의 심각성은 배출가스중에 들어있는, 일산 화탄소(CO), 탄화수소(HC), 질소산화물(NOx), 알데히드, 연화합물 및 발암성 방향족화합물 등 으로, 이것은 인체에 유해한 영향을 주고 있다. 이와 같은 실정에서 인간의 건강을 공해로부터 보호하기 위한 기준으로 세계보건기구 WHO 는 1972년 "WHO Technical Report Series, No.506" 에서 SO$_{2}$ 분진 일산화탄소 및 photochemical 에 대하여 기준 목표를 설치하였다.목표를 설치하였다.

  • PDF

Review on U.S. Army Helicopter Mishap Analysis for Revision of Crashworthiness Requirements (내추락성 요구도 개정을 위한 미 육군 헬기 사고사례 분석 고찰)

  • Hwang, Jungsun;Lee, Sangmok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.9
    • /
    • pp.734-739
    • /
    • 2013
  • Representative crashworthiness requirement documents for military helicopter are MIL-STD-1290 and the Aircraft Crash Survival Design Guide(ACSDG) which were lastly revised in the 1980's. Taking analysis results of diverse U.S. Army helicopter mishaps into account, we can say that adequate guidelines do not exist to ensure crashworthiness of new generation aircraft. In this paper, U.S. Army helicopter mishap analysis conducted by U.S. Army Research, Development and Engineering Command(RDECOM) is readjusted to review the basis of new crashworthiness design criteria for military helicopter, in other words, Full Spectrum Crashworthiness Criteria(FSCC). This analysis effort is a part of FSC development. This effort was to research and quantify the dynamics of military aircraft crashes to be used as the quantitative basis for new design criteria.

Establishment for analytical method of methanol in wet wipes by headspace gas chromatography (가스크로마토그래프-헤드스페이스를 이용한 물휴지 중 메탄올 정량법 확립 연구)

  • Choi, Yongkyu;Baek, Eunji;Min, Chungsik;Lee, Rheeda;Park, Soonyoung;Ahn, Jaehyung;Kim, Sangseop;Hong, Seonghwa;Kim, Younglim
    • Analytical Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.242-247
    • /
    • 2016
  • This research aims to set up and validate methods of analyzing the methanol in wet wipes and verifies the analysis methods that applied to the wet wipes. We used Headspace (HS) Gas Chromatography (GC) - Flame Ionization Detector (FID) to the establish analysis method of methanol in wet wipes and optimized heating temperature, heating time, GC conditions with column. The result indicated that 3 mL of sample in 20 mL headspace vial can be equilibrated efficiently in headspace sampler at 70 ℃ for 10 min and sample was measured by GC with spli injection mode(10:1). The results show that linearity from 1 to 100 ppm was over R2 0.9995, precision was RSD 1.83 % and accuracy(recovery rate) was 105.44 (±1.05 %) on water matrix and wet wipes matrix removed non-woven fabric. Also, monitoring results of total 20 cosmetics on the market, from 0.00017 to 0.00156 % of methanol was detected from wet wipes.

The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy (인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가)

  • Kim, Jong Wook;Woo, Heon;Jeong, Hyeon Hak;Kim, Kyeong Ah;Kim, Chan Yong;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.329-336
    • /
    • 2014
  • Purpose : To evaluate the dose on a contralateral breast and the usefulness of shielding according to the distance between the contralateral breast and the side of the beam by breast size when patients who got breast implant receive radiation therapy. Materials and Methods : We equipped 200 cc, 300 cc, 400 cc, and 500 cc breast model on the human phantom (Rando-phantom), acquired CT images (philips 16channel, Netherlands) and established the radiation treatment plan, 180 cGy per day on the left breast (EclipseTM ver10.0.42, Varian Medical Systems, USA) by size. We set up each points, A, B, C, and D on the right(contralateral) breast model for measurement by size and by the distance from the beam and attached MOSFET at each points. The 6 MV, 10 MV and 15 MV X-ray were irradiated to the left(target) breast model and we measured exposure dose of contralateral breast model using MOSFET. Also, at the same condition, we acquired the dose value after shielding using only Pb 2 mm and bolus 3 mm under the Pb 2 mm together. Results : As the breast model is bigger from 200 cc to 500 cc, The surface of the contralateral breast is closer to the beam. As a result, from 200 cc to 500 cc, on 180 cGy basis, the measurement value of the scattered ray inclined by 3.22 ~ 4.17% at A point, 4.06 ~ 6.22% at B point, 0.4~0.5% at C point, and was under 0.4% at D point. As the X-ray energy is higher, from 6 MV to 15 MV, on 180 cGy basis, the measurement value of the scattered ray inclined by 4.06~5% at A point, 2.85~4.94% at B point, 0.74~1.65% at C point, and was under 0.4% at D point. As using Pb 2 mm for shield, scattered ray declined by average 9.74% at A and B point, 2.8% at C point, and is under 1% at D point. As using Pb 2 mm and bolus together for shield, scattered ray declined by average 9.76% at A and B point, 2.2% at C point, and is under 1% at D point. Conclusion : Commonly, in case of patients who got breast implant, there is a distance difference by breast size between the contralateral breast and the side of beam. As the distance is closer to the beam, the scattered ray inclined. At the same size of the breast, as the X-ray energy is higher, the exposure dose by scattered ray tends to incline. As a result, as low as possible energy wihtin the plan dose is good for reducing the exposure dose.