• Title/Summary/Keyword: 인체신호

Search Result 394, Processing Time 0.021 seconds

Analysis of the Relationships according to the Frame (f/s) Change of Cine Imaging in Coronary Angiographic System: With Focus on FOV Enlargement and Live Zoom (심장 혈관 조영장치에서의 프레임 레이트(f/s) 변화에 따른 상관 관계 분석 : FOV 확대와 Live Zoom을 중점으로)

  • Kim, Won Hyo;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.845-852
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing absorbed dose according to changes in the number of frames in coronary angiography, also depending whether the zoom mode is FOV enlargement or Zoom Live. Moreover, for appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring the noise strength expressed by the standard deviation (SD), the signal to noise ratio (SNR) and contrast to noise ratio (CNR). The study was conducted with an anthropomorphic phantom on an angio-system. The linear relationship between the frame rate and the radiation dose was evident. On the contrary, the indices of image quality (SD, SNR, and CNR) were almost constant irrespective of the number of frames. The difference depending on the zoom mode was not statistically significant for DAP, air kerma, and SD (p > 0.05). However, SNR and CNR were statistically different between FOV enlargement and Zoom Live. In conclusion, since the image quality was not degraded significantly with the decreasing frame rate from 30, 15, to 7.5 f/s and the radiation dose evidently decreases in almost exactly linear proportion to the decreasing frame rate, the number of frames per second needs to be maintained as low as reasonably achievable. As for the dependence on the zooming mode, the Live Zoom mode showed statistically significant improvement in the image quality indices of SNR and CNR and it justifies active use of the Live Zoom mode which enables real-time image enlargment without additional radiation dose.

The Effects of Heated Radish Extract on the Prevention of Ulcerative Colitis Inflammation (열처리된 무 추출물의 궤양성 대장염증 예방 효과에 미치는 영향)

  • Kim, Hyun Kyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.317-326
    • /
    • 2019
  • The present study aimed to investigate the comparative evaluation of pharmacological efficacy between sulfasalazine alone and combination with herbal medicine on dextran sodium sulfate (DSS)-induced UC in mice. Balb/c mice received 5% DSS in drinking water for 7 days to induce colitis. Animals were divided into five groups (n = 9): group I-normal group, group II-DSS control group, group III-DSS + sulfasalazine (30 mg/kg), group IV-DSS + sulfasalazine (60 mg/kg), group V-DSS + sulfasalazine (30 mg/kg) + Radish Extract mixture (30 mg /kg) (SRE). DSS-treated mice developed symptoms similar to those of human UC, such as severe bloody diarrhea and weight loss. SRE supplementation, as well as sulfasalazine, suppressed colonic length and mucosal inflammatory infiltration. In addition, SRE treatment significantly reduced the expression of pro-inflammatory signaling molecules through suppression both MAPK) and nuclear factor-kappa B (NF-${\kappa}B$) signaling pathways, and prevented the apoptosis of colon. Moreover, SRE administration significantly led to the up-regulation of anti-oxidant enzyme including SOD and Catalase. This is the first report that Radish extract mixture combined with sulfasalazine protects against experimental UC via the inhibition of both inflammation and apoptosis, very similar to the standard-of-care sulfasalazin.

A Comparative Study of Patient Dose and Image Quality according to the Presence or Absence of Grid During Chest PA Radiography using an Auto Exposure Control System (자동 노출 조절장치를 사용한 흉부 후·전 방향 방사선 검사 시 격자 유·무에 따른 환자 선량과 영상품질 비교 연구)

  • So-min Lee;Han-yong Kim;Dong-hwan Kim;Young-Cheol Joo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.573-579
    • /
    • 2023
  • This study compares dose difference between the presence or absence of grid in Chest PA radiography using auto exposure control and compares image quality among presence, absence or virtual grid, and proposes a new clinically useful grid combination for chest radiography. The human body phantom was placed Chest PA position and the dosimeter was placed at T6. The same irradiation conditions and field size were applied. 30 images were obtained in the state in which grid was applied and in the state in which grid was not applied, and an additional 30 images in which the virtual grid was applied to the image without the grid were obtained. Radiation dose was presented to entrance surface dose. The image quality was analyzed by comparing the signal-to-noise and contrast-to-noise ratio. ESD decreased by 48% when the grid was not used, compared to when the grid was used. SNR and CNR increased by 32% and 30% compared to grid use when grid was not used, respectively. In the case of using the virtual grid, it increased by 18% and 16% respectively, compared to the case of using the grid. As a result of this study, it is believed that when using a virtual grid instead of a grid, the quality of the image can be maintained while reducing the patient dose.

Fabrication of pyroelectric IR sensors with PLT thin plates compensating for piezoelectric effect (PLT 박편을 이용한 압전특성이 보상된 초전형 적외선 센서의 제작)

  • Kim, Young-Eil;Roh, Yong-Rae;Choi, Sie-Young
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-5
    • /
    • 1997
  • Highly sensitive pyroelectric IR sensors were fabricated with La-modified $PbTiO_{3}(PLT)$ thin plates compensating for piezoelectric effect. The device was fabricated in a dual form by placing two PLT cells, each of $1{\times}2\;mm^{2}$, side by side with appropriate electrode configuration. The dual element sensor had a signal to noise ratio of about 350 that was much larger than that of single element sensors. Further the dual element sensors exhibited excellent pyroelectric properties such as a large voltage responsivity of 2400 V/W, a pyro-coefficient of $4.6{\times}10^{-8}\;C/cm^{2}K$, a voltage figure of merit of $4.2{\times}10^{-11}\;Ccm/J$, and a small thermal time constant of 8.7 msec. It was confirmed through experiments that the dual element sensor was applicable to detect the two-dimensional moving direction of human beings.

  • PDF

Evaluation of Image Quality according to the Use of Attachable X-ray Table Equipped with Heating Device (가열장치를 구비한 부착형 X선 촬영대의 사용에 따른 화질 평가)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.219-225
    • /
    • 2015
  • This study aims to evaluates the image quality of CR and DR that are scanned with the use of the attachable carbon heater X-ray scanner table equipped with heating device by measuring SNR and CNR before and after the attachment of the said table. In the aluminum staircase testing, CR increased SNR and CNR when attached with the table, while DR decreased SNR and CNR. In the human-body model phantom testing, CR increased SNR and CNR only in the low-energy low-dose radiation and the high-energy high-dose radiation, but decreased SNR and CNR under all other conditions. In conclusion, the use of such table can make the patient feel comfortable by removing his or her anxiety, thus helping the testing, but in the actual clinical application thereof, if the thickness and material of the bottom film and the protective film, including the carbon heater, are not considered, it affects the picture quality, thereby requiring continuous research on the use of such table.

Development of Body-Weight-Support System for Walking Rehabilitation (보행 재활을 위한 신체 자중 보상용 모바일 로봇에 관한 연구)

  • Suh, Seung-Whan;Yu, Seung-Nam;Lee, Sang-Ho;Han, Chang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3658-3665
    • /
    • 2010
  • As the population of elderly people and disabled people are increased, various demands for human welfare using robot system are raised. Especially autonomous rehabilitation system using robot could reduce the human effort while maintaining the its intrinsic efficacy. This study deals with mobile gait rehabilitation system which combined with BWS (Body Weight Support) for training of elderly and handicapped people who suffer the muscle force weakness of lower extremity. BWS which is designed by kinematic analysis of body lifting characteristics and walking guide system are integrated with main control system and wheeled platform. This mobile platform is operated by UCS (User Command System) and autonomous trajectory planning algorithm. Finally, through the EMG (Electromyography) signal measuring and its analysis for subject, performance and feasibility of developed system is verified.

Guided Wave Tomographic Imaging Using Boundary Element Method (경계요소법을 이용한 유도초음파 토모그래피 영상화 기법)

  • Piao, Yunri;Cho, Youn-Ho;Jin, Lianji;Ahn, Bong-Young;Kim, Noh-Yu;Cho, Seung-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.338-343
    • /
    • 2009
  • Tomography is the imaging method of cross sectional area using multi beam signals and is mainly applied to the medical diagnosis to acquire the image of the inside human body. This method is pretty meaningful in nondestructive evaluation field since the imaging of the inspection region can enhance the comprehension of the inspector. Recently, much attention has been paid to the guided wave for the diagnosis of platelike structures. So, in this work, a study on the imaging of the damage location in a plate was carried out on the basis of computer aided analysis of guided waves and tomographic imaging. To this end, boundary element method was employed to analyze the effect of the damage in plate on the propagation of the guided waves and the analytic results were applied to the tomographic imaging method to identify the damage location. Consequently, it was shown that the number of sensors heavily affect the inspection performance of the damage location.

Effect of Vibroacoustic Stimulation to Electroencephalogram (음향진동자극이 뇌파에 미치는 영향)

  • Moon, D.H.;Choi, M.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.4
    • /
    • pp.29-36
    • /
    • 2010
  • This study was performed with 5 subjects and used three kinds of music and vibroacoustic stimuli wave based upon each kinds of music. Executing music stimulation, vibro tactile and acoustic wave stimulation to human body were performed. Then measured brain waves were analyzed under each condition including before stimulation, stimulation 1, and stimulation 2. Effects by stimulation results could be studied with experiments and summarized results are followings. 1. It may be concluded that effects on brain waves by music and vibroacoustic stimulation might differ under different situations such as stimulation types with vibroacoustic equipment, human body and mental conditions when measuring, etc.. 2. During stimuli by using music A, B, and C, the effect of $\alpha$ wave, $\beta$ wave, and SMR wave power values show same tendency to the subject c but music C had very different tendency during vibroacoustic stimuli. 3. During vibroacoustic stimuli by applying the signals of music C, because SMR wave power value was continually increased with consistency comparing to Bst, this can be estimated that an application of inducing mind concentration condition would be possible under relaxed body and mind conditions. 4. To secure data significance, all measured data need to be tested statistically whether data would be interrelated or not.

Pedestrian Walking Velocity Estimation based on Wearable Inertial Sensors and Lower-limb Kinematics (착용형 관성센서 및 인체 하지부 기구학 기반의 보행자 속도추정에 관한 연구)

  • Kim, Myeong Kyu;Kim, Jong Kyeong;Lee, Donghun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.799-807
    • /
    • 2017
  • In this paper, a new method is proposed for estimating pedestrians' walking velocity based on lower-limb kinematics and wearable inertial measurement unit (IMU) sensors. While the soles and ground are not in contact during the walking cycle, the walking velocity can be estimated by integrating the acceleration output of the inertial sensor mounted on the pelvis. To minimize the effects of acceleration measurement errors caused by the tilt of the pelvis while walking, the estimated walking velocity based on lower-limb kinematics is imposed as the initial value in the acceleration signal integration process of the pelvis inertial sensor. In the experiment involving outdoor walking for six minutes, sensor drift due to error accumulation was not observed, and the RMS error in the walking velocity estimation was less than 0.08 m/s.

The role of myokine(interleukin) and exercise for the prevention of scarcopenia and anti-inflammation (근감소 및 염증 예방을 위한 운동과 인터루킨(IL-interleukin)의 역할)

  • Byun, Yong-Hyun;Park, Woo-Young
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.509-518
    • /
    • 2018
  • The purpose of this study was myokine product and role with physical activity and literature review. There is accumulating epidemiological evidence that a physically active life plays an independent role in the protection against type 2 diabetes, cardiovascular disease, colon cancer, dementia and even depression. And myokine has been regarded an important factor of exercise training and brain growth factor for the prevention of Alzheimier's disease. During exercise the release of anti-inflammatory myokine from contracting muscle controled the metabolic response, and IL-4, IL-6, IL-7, IL-10, and IL-15 controled muscle hypertrophy, myogenesis and angiogenenesis. IL-6 promoted the lipid metabolism through AMPK activation. IL-1Ra, IL-10 and sTNF-R inhibited $TNF-{\alpha}$ as the pro-inflammatory cytokine. IL-15 increased the releasing volume from contracting muscle, and promoted the anabolic factor of muscle growth. IL-7 and IL-8 activated the angiogenesis through the more activation of C-X-C receptor signal transmission.