• Title/Summary/Keyword: 인조 팔

Search Result 6, Processing Time 0.018 seconds

Development of Indentation Training System for Pulse Diagnosis (맥진 가압 트레이닝 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Woo, Young-Jae;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.117-122
    • /
    • 2008
  • Although the pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors, there is no proper communication tool between experts and trainees. In this paper, we have developed a indentation training system which consists of a hardware measuring indent pressure on artificial arm quantitatively and a software providing a indentation training program. The hardware for measurement of indent pressure profile includes 3 load cells embedded in the artificial arm, signal amplification part and digitization part, NI-USB 6009 with 200Hz sampling rate. For setting up a relationship table between weights and output voltages, 8 standard weights were used. To evaluate this hardware, 3 oriental medical specialists were involved and their indent pressure profile were recorded three times respectively. From these, it was found that pulse diagnosis process could be divided into 3 periods and the maximum load were $500g{\cdot}f$ approximately while doctors perform a pulse diagnosis. The indentation training program was implemented with LabView and designed to monitor the differences between the pressure profile of a expert and that of a trainee so to offer some visual feedback to the trainee. Also, this program could provide the trends of training performances. With this developed system, the education of pulse diagnosis is expected to be more quantitative and effective.

Reverse Engineering (역설계)

  • Nobles, Herbert D.
    • Journal of the KSME
    • /
    • v.33 no.4
    • /
    • pp.311-314
    • /
    • 1993
  • 역설계란 제품에서부터 역으로 그것의 수학적인 형상을 얻는 기법이다. 생산현장과 설계분야에서 역설계의 응용사례는 많다. 예를 들면 자동차 외형설계자는 자유곡면(free form)을 만들고, 이것 에서 역으로 스템핑 다이(stamping die)를 가공한다. 물론 외형 설계자는 자유곡면을 생성하기 위해 스틸이나 커크사이트(kirtsite)보다는 원하는 형상을 만들기 쉬운 진흙을 사용한다. 생산부 서에서는 가공물의 설계도가 분실되거나 훼손되어 완성된 제품에서 도면이 복사되어야 할 경우가 생기게 된다. 역설계는 복제가 요구되는 어떤 형상도 적용이 가능하다. 응용대상은 특히 완구, 인조팔, 스템핑다이, 폼 블록(from block), 욕조기, 가구, 일상용품 등이며 적용대상은 광범위하다. 역설계는 설계자가 습득해야 할 필요기술이고, 현재의 CAD/CAM 적용영역을 새로운 세계로 확대시킬 것이다.

  • PDF

Central Vein Occlusion Secondary to Hemodialysis Catheterization in Chronic Renal Failure Patient -One Case Report- (만성 신부전 환자에서 혈액투석 도관에 의한 중심정맥 폐쇄증의 수술치험 -1례 보고-)

  • Lee, Seock-Yeol;Lee, Jun-Bock;Lee, Man-Bok;Youm, Wook;Lee, Kihl-Rho
    • Journal of Chest Surgery
    • /
    • v.31 no.6
    • /
    • pp.619-623
    • /
    • 1998
  • A 51-year-old male with chronic renal failure had marked swelling and tenderness of the right arm. Venography revealed central vein occlusion involving stenosis of right proximal subclavian vein, right internal jugular vein, and left distal innominate vein, and obstruction of right brachiocephalic vein. Multiple obstruction of these veins was thought to have resulted from repeated subclavian catheterization. Right subclavian-superior vena cava was bypassed with 10 mm Gore-tex vascular graft and then left subclavian vein with 8 mm Gore-tex vascular graft was bypassed to the 10 mm Gore-tex vascular graft. The results were excellent.

  • PDF

Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location (혈액투석 접근로 기능부전에서의 비피복형 스텐트: 접근로 종류와 스텐트 위치에 따른 개통률 평가)

  • Kyungmin Lee;Je Hwan Won;Yohan Kwon;Su Hyung Lee;Jun Bae Bang;Jinoo Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.197-211
    • /
    • 2023
  • Purpose To evaluate the circuit patency after nitinol bare-metal stent (BMS) placement according to the type of access and location of the stent in dysfunctional hemodialysis access. Materials and Methods Between January 2017 and December 2019, 159 patients (mean age, 64.1 ± 13.2 years) underwent nitinol BMS placement for dysfunctional access. The location of stents was as follows: 18 brachiocephalic vein, 51 cephalic arch, 40 upper arm vein, 10 juxta-anastomotic vein, 7 arteriovenous (AV) anastomosis, and 33 graft-vein (GV) anastomosis. Circuit patency was evaluated by the Kaplan-Meier method, and cox regression model. Results A total of 159 stents were successfully deployed in 103 AV fistula (AVF) and 56 AV graft (AVG). AVG showed lower primary and secondary patency at 12-months compared with AVF (primary patency; 25.0% vs. 44.7%; p = 0.005, secondary patency; 76.8% vs. 92.2%; p = 0.014). Cox regression model demonstrated poorer primary patency at 12 months after stenting in the cephalic arch and GV anastomosis compared with the other sites. Conclusion AVF showed better primary and secondary circuit patency at 12 months following the placement of BMS compared with AVG. Stents in the cephalic arch and GV anastomosis were associated with poorer primary patency at 12 months compared to those in other locations.

Surgical Treatment of Occluded Aberrant Left Subclavian Artery with Right-sided Aortic Arch -A case report- (우측 대동맥궁을 가진 환자에서 이상 기시된 좌쇄골하 동맥 폐색의 수술적 치료 - 1예 보고)

  • Cho Yang Hyun;Ryu Se Min;Kim Hyun Koo;Cho Jong Ho;Sohn Young-sang;Choi Young Ho;Kim Hark Jei
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.241-244
    • /
    • 2005
  • A 57-year-old man with numbness and paresthesia of left arm is presented. There was no pulse in the left arm was absent and his chest radiograph suggested right-sided aortic arch. The aortogram showed right-sided aortic arch with Kommerell's diverticulum. The proximal portion of left subclavian artery was totally occluded and blood was being supplied through vertebral arteries to distal subclavian artery. He underwent bypass grafting between both subclavian arteries by an expanded polytetrafluoroethylene graft. Because the size of Kommerell's diverticulum was small, it need to be observed closely.

Surface Characteristics of Dental Casting Palladium Alloy for Replacement of Gold Alloy (금대체를 위한 치과주조용 파라듐 합금의 표면특성)

  • Park, Seon-Yeong;Hwang, In-Jo;Yu, Ji-Min;Park, Min-Gyu;Im, Sang-Gyu;Bae, Ho-Seong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.196-196
    • /
    • 2016
  • 치과나 기공소로부터 높은 원가로 인한 재료선택에 어려움을 겪고 있어 귀금속 금합금의 물성을 가질 수 있도록 하면서 가격급등으로 인한 문제 해결하기 위한 비귀금속 합금으로 대체가 필요하기에 이에 따른 연구가 이루어져 국산 제품의 상품화를 위해 파라듐을 이용하여 적합한 새로운 합금을 개발하는 것이 필요하다. 치과용 골드합금은 미국치과의사 협회의 구정에 의하면 1형부터 4형까지 분류하고 있으며 3형에 해당하는 강도와 기계적인 특성을 갖도록 파라듐으로 대체하는 연구가 진행중이거나 시판되고 있다. 따라서 본 연구에서는 2형, 3형 및 4형을 대체가능하도록 팔라듐을 기반으로 한 새로운 합금을 설계하고 합금의 성분원 소인 Au(1~5), Pd(20~25), Ag(70~75), In(1.5) 및 Zn(2)등으로 조성을 변화시켜 측량 후 합금을 제조하기 위하여 아르곤 분위기하의 진공아크용해로를 이용하여 용해하였다. 정량된 금속을 진공아크 용해로에 장입하고 용해는 균질한 합금이 되도록 최소한 6회 이상 용융을 실시하며 합금성분의 손실이 발행하지 않도록 보정을 하였다. 합금의 미세조직 관찰을 위하여 샘플을 고속 다이아몬드 정밀 절단기(Acculom-5, STRUERS, Denmark)를 이용하여 절단한 후 2000 grit의 Sic 연마지에서 단계적으로 $0.3{\mu}m$ 알루미나 분말까지 연마한 후 초음파 세척을 하였다. 준비한 시편은 KCN과 $(NH_4)_2S_2O_8$을 1:1로 혼합한 부식액으로 에칭한 후 OM과 SEM을 이용하여 조직을 관찰하였으며 각 샘플의 성분변화는 EDS 분석을 통해 확인하고 결정구조는 XRD를 사용하여 분석하였다. 경도시험은 비커스경도시험기를 이용하여 5kg의 하중을 30초간 작동시켜 압흔을 연결된 micron으로 평균값을 측정하였다. 각 시편의 부식거동은 POTENTIOSTAT(Model PARSTAT 2273, EG&G, USA)을 이용하여 구강 내환경화 유사한 $36.5{\pm}1^{\circ}C$의 0.9% NaCl에서 실시하였다. 인가전위는 -1500mV에서 1000mV까지 1.67 mV/min의 주사속도로 인가하여 시험을 수행하였으며 분극곡선으로부터 부식전위와 부식전류밀도 및 부동태영역의 전류밀도로 금속의 용출거동을 조사하였으며 부식이 끝난 시편은 FE-SEM과 EDS를 사용하여 조사하였다. 기계적인 특성은 Pd-Ag에 3wt%의 Au를 첨가한 합금이 Pd-Ag에 1.5wt%합금을 첨가한 경우에 비하여 기계적인 특성이 증가하고 내식성이 크게 증가하였다. 이들 합금에 Cu를 11wt%를 첨가한 경우는 비커스경도가 200이상으로 높게 나타났지만 내식성이 크게 감소하였다.

  • PDF