• Title/Summary/Keyword: 인접 조사면

Search Result 103, Processing Time 0.039 seconds

Dose distribution at junctional area abutting X-ray and electron fields (X-선과 전자선의 인접조사에서 접합 조사면에서의 선량분포)

  • Yang, Kwang-Mo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.91-99
    • /
    • 2004
  • Purpose : For the head and neck radiotherapy, abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Materials and methods : Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom according to depths(0 cm, 1.5 cm, 3 cm, 5 cm). 6 MV X-ray and 9 MeV electron(1Gy) were exposes to 8cm depth and surface(SSD 100cm) of phantom. The dose distribution to the junction line between photon($10cm{\times}10cm$ field with block) and electron($15cm{\times}15cm$ field with block) fields was also measured according to depths(0 cm, 0.5 1.5 cm, 3 cm, 5 cm). Results : At the junction line between photon and electron fields, the hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to $6\%$ of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was $4.5-30\%$ of reference dose in the electron field. Conclusion : When we make use of abutting photon field with electron field for the treatment of head and neck cancer we should consider the hot and cold dose area in the junction of photon and electron field according to location of tumor.

  • PDF

INDEPENDENT JAW를 이용한 인접한 HALF BEAM 조사야 경계에서 조작방법과 조작자에 따른 선량오차의 경향

  • 서정민;박용철;주상규
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.13 no.1
    • /
    • pp.126-129
    • /
    • 2001
  • I. 목적 : Half beam을 이용하여 인접한 조사면 치료시, 경계부위에서 발생할 수 있는 Jaw Position에 의한 기하학적 오차는 정확한 선량전달에 문제를 일으킨다. 이에 본 저자는 QA용 필름을 이용하여 조사면 setting 방법과 조작자간의 오차를 분석하고 이를 최소화할 수 있는 방법을 찾고자 한다. II. 대상 및 방법 : 본 실험은 6MV선(CL2100C, Varian, USA)을 대상으로 하였으며, 폴리스틸렌팬톰($25{\times}25cm2$)을 SSD 100 cm으로 고정한 후, 측정용 필름(X-omat V2, Kodak, USA)을 5 cm 깊이에 위치 시켜 조사면의 중심에서 경계를 이루는 비대칭 조사면 ($0/7.5{\times}15,7.5/0{\times}15 cm$)을 쌍으로 조사하였다. 조사된 필름은 자동현상기를 이용하여 현상한 후 농도계(Densitometer, Multidata, USA)를 이용하여 중심축상에서의 농도분포를 측정하여 인접한 조사면에서의 오차를 분석하였다. 조작방법과 조작자간의 오차를 분석하기 위하여 5명의 방사선사를 대상으로 auto및 manual set-up을 실시하였고 각 방법의 평균 오차를 분석하기 위해 5회 반복하였다. III. 결과 : 필름 농도곡선을 이용하여 두 조사면이 만나는 경계에서의 오차를 분석한 결과, remote console set-up의 경우 주변 조사면에 비해 $-0.16{\pm}3.44\%$, pendant방식에서는 $+5.04{\pm}4.37\%$로 나타났고, 조작자간의 유의성이 관찰되었다. IV. 결론 : 비대칭 조사면을 이용한 근접 조사면의 치료시 pendant 방식보다 remote console 방식에서 오차가 적 게 나타나므로 Auto set-up 기능의 이용은 치료시에 조사면 경계에서의 선량 오차를 최소한으로 줄이는데 도움이 될 것으로 생각된다. 또한 manual 방식으로 set-up 시 오차의 편차가 크게 나타나므로 치료시에 세심한 주의가 필요할 것으로 사료된다.

  • PDF

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

Characteristics of Dose Distribution at Junctional Area Using the Divergency Cutout Block in the Abutted Field of Photon and Electron Beams (광자선과 전자선의 인접조사에서 선속 퍼짐현상이 고려된 전자선 차폐물을 이용한 접합 조사면의 선량분포 특성)

  • Im, In-Chul;Lee, Jae-Seung
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.3
    • /
    • pp.168-173
    • /
    • 2011
  • This study investigated characteristics of dose distribution at junction field of X-ray and electron beams according to the method for fabricating the insert block on the electron cone. Insert block were fabricated to the divergency cutout block and the straight cutout block. For the 6 MV X-ray and 10 MeV nominal energy of electron beam, we was adjacent to the light field of X-ray and electron beam at a surface of matrix chamber and measured to beam profile of abutted field in the 0, 1, 2, 3 cm measurement depth. As a result, characteristics of dose distribution at junction field, straight block was existent that over dose area exceed the give dose more than 5% and under dose area with a rapid change in dose distribution. However, divergency block had remarkably decreased the over dose area caused by the lateral scattering effects of decrease, and being existed uniformity dose distribution in the junction field. Therefore, divergency block were the benefits of radiation dose delivery, in order to applied the clinical, measurement of electron beams according to the fabrication method of the block should be considered carefully.

ROC Analysis of Acid Demineralized Artificial Caries (인공치아 우식병소 진단의 ROC 분석)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.7-13
    • /
    • 1997
  • 조직학적으로 유용성이 입증된 산탈회법을 이용한 인접면 비교적 초기 치아 우식의 병소를 형성하여 진단율을 조사하였다. 산 용액을 이용하여 20개 인접면 치아우식을 20개 소구치에 형성하였고, 37개 인접면 치아우식을 30개 대구치에 형성하였다. 건전한 소구치 20개, 대구치 30개를 포함하여 총 96개 치아를 4개씩 나누어 24개의 블록을 형성하였고, 각각 2개 블록의 교합면을 교합시켜서, 교익촬영을 하였다. 촬영 결과를 36명의 치과의사들이인접면 치아우식의 유무를 기록하고, 동시에 및 ROC 분석을 위한 5 개 범주의 판독 기준으로 판독하여 기록하였다. 인접면 치아우식증 유, 무만으로 판독한 결과 진단의 sensitivity는 0.71, specificity는 0.78 이였다. ROC 분석 한 결과의 곡선도표 아래부분의 평균 면적은 약 0.806 이였다. 치아우식증 유무만으로 진단한 결과는 특정한 sensitivity와 specificity 만을 나타내지만, ROC 분석 결과는 주관적 진단 기준과 구별되는 고유의 진단 능력을 표시하는 1-specificity(False Positive)의 변화에 따른 sensitivity(True Positive)의 변화를 연속적으로 나타내어 주었다.

  • PDF

Association between Regular Interdental Cleaning and Periodontal Condition among Pregnant Women (임부의 정기적인 인접면 세균막 관리와 치주건강상태간의 연관성)

  • Ha, Jung-Eun;Kim, Hyun-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.8
    • /
    • pp.144-151
    • /
    • 2017
  • The aim of this cross-sectional study was to investigate the relationship between regular interdental cleaning and periodontal condition. A total of 319 pregnant women were recruited at 21 to 24 weeks of gestation. Information on demographics, health status and health behaviors including regulary use of interdental cleaning aids, that can influence periodontal condition was collected. Full mouth periodontal probing was performed. Periodontitis was defined as CAL of 4.0 mm or greater on 2 or more sites not on the same tooth. Gingivitis was defined as 15 percent and more sites showed bleeding on probing. Gingival crevice fluid sample was collected for bacterial analysis. We studied a total of 319 subjects, comprised of 116 subjects who use interdental cleaning device regularly and 203 subjects who didn't. Subjects who do not use interdental cleaning regularly had 2.3 times higher risk of gingivitis and 2.7 times of periodontitis, 2.3 times more amount of P. gingivalis. There was a significant relationship between regular interdental cleaning and periodontal condition in Korea.

세기조절방사선치료 조사면의 최소 조각 크기에 대한 치료중 표적 움직임의 효과

  • 서예린;이병용;안승도;이상욱;김종훈;신성수;신승애;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.37-37
    • /
    • 2003
  • 목적 : 일반적으로 세기조절방사선치료 조사면의 작은 조각 크기에 대해, 이상적인 플루언스 지도 혹은 치료계획장치로부터의 최적화된 결과에 가까운 선량분포에서 더 좋은 leaf sequence를 얻을 수 있다. 한편, 치료중 장기의 움직임이 가장 작은 조각 크기의 선택을 방해하는 문제는 항상 존재한다. 게다가, 전통적인 정지 조사면과 달리 표적이 움직이는 동안 조사면 자체도 움직이므로 움직이는 표적에 대한 세기조절방사선치료의 경우에서 적절한 표적 마진에 관한 질문이 제기되어왔다. 따라서, 이 연구에서는 조각 크기에 대한 치료중 표적 움직임의 효과를 연구하였다. 대상 및 방법 : 세기조절방사선치료 플루언스 지도에 대해, 다양한 크기 - 0.5$\times$0.5, 1.0$\times$1.0, $1.5\times$1.5, 2.0$\times$2.0, 3.0$\times$3.0, 4.0$\times$4.0, 5.0$\times$5.0 $ extrm{cm}^2$ - 의 정사각형 패턴들을 설계하였고, Leaf sequence 는 step-and-shoot 빔 전달 방법을 이용하였다. 인접 조각들 사이의 세기 비율은 0.2, 0.4, 0.6, 0.8, 1.0로 하였고, 표적 움직임은 범위가 0.5-2.0 cm인 사인곡선 형태로 가정하였다. 움직임 묘사를 위해 동적 leaf 의 움직임이 표적의 움직임 을 반영하도록 계산되었고 움직임의 효과를 분석하기 위해 필름선량측정을 수행하였다. 결과 : 인접 조각의 세기 비율은 모든 경우에서 저하되었고, 호흡 진폭의 반보다 작은 조각 크기에 대한 선량분포는 임상적으로 유의할만큼 저하된 세기 지도를 보였다. 조각에 대해 방사선 조사시간의 두 호흡주기이상에 대해서는, 표적 마진 주위의 선량분포가 통상적인 정지 조사면에서와 같았다. 결론 : 플루언스 지도에서 세기조절방사선치료 조각의 최소 크기는 치료중 장기 움직임을 고려한 후 선택되어야 한다. 조각에 대한 방사선 조사시간의 두 호흡주기이상에 대해서는, 표적 마진을 기존의 정지 조사면과 같게 정의할 수 있었다.

  • PDF

TOOTH SURFACE CARIES PATTERNS IN THE PRIMARY DENTITION ACCORDING TO BREAST OR BOTTLE FEEDING (수유 요인에 따른 유치열의 치면별 우식패턴)

  • Im, Kyeong-Wook;Lee, Kwang-Hee;Ra, Ji-Young;An, So-Youn;Kim, Yun-Hee
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.2
    • /
    • pp.151-158
    • /
    • 2010
  • The purpose of this study was to investigate the tooth surface caries patterns in the primary dentition according to breast or bottle feeding. The subjects of study were 815 children, 36 to 71 months old, in Iksan, Cheongju and Ulsan cities. The caregivers of the children were asked which they fed between the breast milk and the infant formula during the 1st year after birth and the duration of feeding. There was no significant difference in dmfs between the breast milk group and the infant formula group(significance level 0.05, same below). Tooth groups, tooth surface groups, teeth, and tooth surfaces which had significantly higher dmfs in the breast milk group than in the infant formula group were upper anterior teeth(tooth groups), upper incisors' buccal and proximal surfaces(tooth surface groups), upper incisors and upper second molars(teeth), upper central incisors' buccal and distal surfaces, upper lateral incisors' buccolingual and proximal surfaces, upper 2nd molars'lingual, proximal, and occlusal surfaces, and lower 2nd molars' buccal and distal surfaces. In the breast milk group, tooth groups, tooth surface groups, teeth, and tooth surfaces which dmfs significantly increased as the duration of the feeding increased were upper anterior teeth and upper molars(tooth groups), upper anterior teeth's proximal surfaces, upper molars' buccolingual, proximal, and occlusal surfaces, lower molars' proximal surfaces(tooth surface groups), upper anterior teeth, upper molars, lower 2nd molars(teeth), upper anterior teeth's proximal surfaces, upper 1st molars'buccolingual, proximal, and occlusal surfaces, upper 2nd molars' buccal surfaces, and lower 2nd molars'mesial surfaces(tooth surfaces). In the infant formula group, dmfs increased after 3 years of feeding, but the difference was not significant. Caries prevention is necessary in case of breastfeeding more than two years.

A Case Study of Collapse at Tunnel Portal adjacent to the Large Cut Slope (대절토사면과 인접한 터널갱구부의 붕괴사례연구)

  • Koo, Ho-Bon;Kim, Seung-Hee;Rhee, Jong-Hyun;Kim, Jin-Hwan
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.573-576
    • /
    • 2008
  • 절토사면 및 천심도 터널의 경우 불연속면을 따른 블록의 미끄러짐 및 회전 등이 안정성에 큰 영향을 미친다. 국도나 지방도 등을 확장 공사함에 따라 산악이 많은 우리나라 지형의 특성상 절토사면이 많이 발생하게 되고, 경우에 따라서는 이러한 절토사면에 터널이 위치하게 된다. 이런 상황의 터널갱구부 및 인접한 절토사면부에서 붕괴 및 균열이 빈번하게 발생되고 있다. 본 연구에서는 대절토사면과 인접한 터널갱구부에 대하여 편토압이 균열의 주원인인지를 결정하기 위하여 변위 및 응력 패턴을 분석한 사례연구를 제시하였다. 조사대상지역은 울진군에 위치한 터널굴진 현장이고, 붕괴는 터널갱구부와 인접한 절토사면부에서 발생하였으며 터널갱구부 상단의 숏크리트 타설지역에서 다수의 균열이 관찰되었다. 언급한 터널갱구부의 변위 및 응력패턴을 모사하기 위하여 유한차분법에 근거한 플랙을 사용하였으며, 세밀한 수치해석을 위해 편재절리모델을 도입하였다. 마지막으로, 터널갱구부의 균열에 영향을 미친 주원인에 대한 고찰을 다루었다.

  • PDF

Comparison between QraypenTM Imaging and the Conventional Methods of Visual Inspection and Periapical Radiography for Proximal Caries Detection in Primary Molars: An In Vivo Study (유구치 인접면 우식 병소 진단에 있어 QraypenTM과 시진 및 구내 치근단 방사선의 비교)

  • An, So-Youn;Park, So-Young;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.16 no.5
    • /
    • pp.349-354
    • /
    • 2016
  • The purpose of this study was to evaluate the efficacy of the newly-developed $Qraypen^{TM}$ (All In One Bio, Korea) system for the diagnosis of early proximal caries by comparing it with the conventional methods of visual inspection and periapical radiography. This study was carried out from July 2015 to April 2016 targeting 32 children aged 7~12 years who visited Y-Dental Clinic for school oral health examinations. Two investigators selected and examined a total of 153 primary molars that had not undergone restorative treatment. Comparisons were carried out between visual inspections, readings of posterior periapical radiography images, and readings of $Qraypen^{TM}$ images. This study revealed that the percentage of interproximal surfaces of primary molar teeth without caries incidence was 83.7% using $Qraypen^{TM}$ imaging and 84.9% using visual inspection and periapical radiography. The differences between the two methods were not statistically significant. Thus, $Qraypen^{TM}$ is expected to be a useful and convenient auxiliary diagnostic device that can facilitate the detection of hidden proximal caries in primary molars.