• Title/Summary/Keyword: 인장강화

Search Result 343, Processing Time 0.032 seconds

A Study on Degradation in the Moisture Environment and Recovery of Carbon Fiber Reinforced Composites (탄소섬유 강화 복합재료의 수분에 의한 열화 및 회복에 관한 연구)

  • 서상하;이덕보;문창권
    • Composites Research
    • /
    • v.17 no.3
    • /
    • pp.8-14
    • /
    • 2004
  • The effect of moisture absorption on the mechanical properties in carbon fiber reinforced composites has been investigated with various moisture environment such as sea water, tap water and distilled water. It also has been studied about the influence of drying of the immersed specimen for a certain period of time on the mechanical properties. As a result, we found that the ratio of moisture absorption mainly depended on the immersion time in the moisture environment and that of the immersed specimen for a certain period of time decreased with the drying time. We also found that tensile strength decreased with the increasing of the ratio of moisture absorption and the tensile strength decreased by moisture absorption recovered up to some extent by drying the specimen.

An Experimental Study for Flexural Failure Behavior of Composite Beam with Cast-in-place High Strength Concrete and GFRP Plank Using As a Permanent Formwork and Tensile Reinforcement (유리섬유강화폴리머 판을 영구거푸집 및 인장 보강재로 활용한 현장타설 고강도콘크리트 합성보의 휨 파괴거동에 관한 실험적 연구)

  • Um, Chan Hee;Yoo, Seung Woon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1015-1024
    • /
    • 2015
  • An experiment of composite beam was performed which utilized glass fiber reinforced polymer (GFRP) plank as the permanent formwork with cast-in-place high strength concrete. This research analyzed the flexural failure behavior of composite beam by setting the sand coated at GFRP bottom surface, the perforation and interval of the GFRP plank web, and the width of the top flange as the experimental variables. As a result of the experiments for effectiveness of sand attachment in case of not perforated web, approximately 43% higher ultimate load value was obtained when the sand was coated than not coated case. For effectiveness of perforation and interval of gap, approximately 23% higher maximum load value was seen when interval of the perforation gap was 3 times and the fine aggregate was not coated, and approximately 11% higher value was observed when the perforation gap was 5 times on the coated specimen. For effectiveness of top flange breadth, the ultimate load value was approximately 12% higher in case of 20mm than 40mm width.

A Study on Mechanical Characteristics and Behaviors of FRP Composite with Three Different types of Matrices under High Temperature (온도 및 매트릭스 특성 변화에 따른 섬유강화 복합재료의 역학적 특성 및 구조적 거동 변화)

  • Jung, Woo-Young;Jang, Jun-Ho;Back, Min-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.1-9
    • /
    • 2008
  • Fiber Reinforced Polymer (FRP) composites are used extensively in aerospace, marine, automotive, infrastructure, chemical processing and sporting good applications. A concern with using FRP composites in some engineering structures is their high flammability and poor fire resistance In this research, material properties of FRP composites at increasingly high temperatures was measured and verified. The obtained mechanical properties of FRP composites were performed according to ASTM D3039/D3039M and tested to a wide range of heat conditions with temperatures from Room-temp. to 300 for times up to 30 min. It is found that the mechanical properties of FRP composites dropped with increasing heat or temperature. The reduction to the properties was due mainly to thermal degradation and combustion of the polymer matrix.

The Study of Mechanical Properties of Degraded Compacted Graphite Iron(CGI) Under 873~1273 K (873~1273 K에서 열화된 강화흑연강의 기계적 특성 연구)

  • Nam, Ki Woo;Lee, Soo Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.173-180
    • /
    • 2013
  • Compacted graphite iron(CGI), also known as vermicular graphite iron, is a metal which is gaining popularity in applications that require either greater strength, or lower weight than cast iron. Recently compacted graphite iron has been used for diesel engine blocks. Considering that using in exhaust manifold of the diesel engine, CGI340 was conducted the heat treatment during 1 hour to 96 hours from 873 to 1273 K. Mechanical characteristics were evaluated. The obtained results are as follows; The tensile strength of the heat treated specimens showed overall lower tensile strength than that of the base metal. Tensile strength decreases with increasing of heat treatment time, and the higher heat treatment temperature and the longer time, were more reduced. The fatigue limit by the ultrasonic fatigue test was approximately 130 MPa of base metal, 100 MPa of 1173 K (96 hrs) specimen, respectively. The hardness decreases with increasing heat treatment time, and the higher the heat treatment temperature was lowered hardness distribution. In CGI340, average hardness of nodular graphite was 120 Hv, average hardness of vermicular graphite was 114 Hv. This showed lower hardness than the base structure ferrite. The nodular graphite and vermicular graphite according to the heat treatment temperature and time didn't have a consistent change. However, the grain size of base structure grew with increasing of heat treatment time.

A Study on Tensile Property due to Stacking Structure by Fiber Design of CT Specimen Composed of CFRP (CFRP로 구성된 CT시험편의 섬유설계에 의한 적층구조에 따른 인장 특성 연구)

  • Hwang, Gue-Wan;Cho, Jae-Ung
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.11
    • /
    • pp.447-455
    • /
    • 2017
  • At the modern industry, the composite material has been widely used. Particularly, the material of carbon fiber reinforced plastic hardened with resin on the basis of fiber is excellent. As the specific strength and rigidity are also superior, it receives attention as the light material. Among these materials, the carbon fiber reinforced plastic using carbon fiber has the superior mechanical property different from another fiber. So, it is utilized in vehicle and airplane at which high strength and light weight are needed at the same time. In this paper, the tensile property due to the fiber design is investigated through the analysis study with CT specimen composed of carbon plastic reinforced plastic. At the stress analysis of CFRP composite material with hole, the fracture trend at the tensile environment is examined. Also, it is shown that the lowest stress value happens and the deformation energy of the pre-crack becomes lowest at the analysis model composed of the stacking angle of 60° through the result due to the stacking angle. On the basis of this study result, it is thought to apply the foundation data to anticipate the fracture configuration at the structure applied with the practical experiment.

Analysis of Composite Response Based on Microstructure Details (복합재료의 미시특성에 따른 기계적 특성해석)

  • 김태우
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.8
    • /
    • pp.784-790
    • /
    • 2003
  • Present investigation shows the analysis results for ceramic reinforced metal matrix composite under uniaxial transverse tensile loading. The resulting deformation, the projected damage type, and stress-strain behavior were computed depending on microstructure details such as the type of periodic reinforcement array, and the type of interface bonding. A two-dimensional finite element analysis was conducted based on the unit-cell of square, hexagonal, or diagonal periodic away For composite with strong interface bonding, the transverse stress vs. strain curve was generally increased with the increase of the ceramic volume fraction. For the composite with weakly bonded interface, however, the transverse stress vs. strain curve was reduced against the ceramic volume fraction. The decrease was caused by the interface debonding-induced stiffness reduction of the composite. For the composite of weakly bonded interface, the relative reduction rate in the final limit stress for hexagonal array was larger than that for square array. Outcome of the present study was compared favorably with the published literature data.

Effect of Slag Particle Size and Volume Fraction on Mechanical Properties of Slag Reinforced Composite (슬래그 입자의 크기 및 체적비에 따른 슬래그 입자강화 복합재료의 기계적 특성 연구)

  • Nam, Ji-Hoon;Chun, Heoung-Jae;Hong, Ik-Pyo
    • Composites Research
    • /
    • v.26 no.4
    • /
    • pp.218-222
    • /
    • 2013
  • This study demonstrated that a slag, an industrial solid waste, can be used as a structural reinforcement. The mechanical properties(tensile strength and Elastic modulus) of slag reinforced composite(SRC) was investigated as functions of slag particle size (8~12 ${\mu}m$ and 12~16 ${\mu}m$) and volume fraction (0-40 vol.%). In order to investigate the interface and a degree of particle dispersion which have an effect on mechanical properties, optical microscopic images were taken. The results of tensile tests showed that the tensile strength decreased with an increase in slag volume fraction and particle size. The elastic modulus increased with an increase in slag volume fraction and particle size except for 30 vol.% SRC. The tensile strength decreased with an increase in slag particle size. The microscopic picture showed SRC has fine degree of particle dispersion at low slag volume fraction. SRC has a good interface at every volume fraction. However particle cluster was incorporated with an increase in slag volume fraction.

AE Characteristics on the Damage Behavior of TiNi/A16061 Shape Memory Alloy Composites at High Temperature (TiNi/A16061 형상기억복합재료의 고온에서의 손상거동에 대한 AE 특성)

  • Lee, Jin-Kyung;Park, Young-Chul;Ku, Hoo-Taek
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.1
    • /
    • pp.45-52
    • /
    • 2002
  • It has been known that tensile residual stresses occurring by the thermal expansion coefficient mismatch between fiber and matrix is a cause of the weak strength of metal matrix composites(MMCs). In order to solve this problem, TiNi alloy fiber was used as a reinforced material in TiNi/A16001 shape memory alloy composite in this study. TiNi alloy fiber improves the tensile strength of the composite by causing compressive residual stress in matrix on the basis of its shape memory effect. Pre-strain was imposed to generate the compressive residual stresses inside the TiNi/A16001 shape memory alloy composites. AE technique was used to quantify the microscopic damage behavior of the composite at high temperature. The effect of applied pre-strains on the AE behavior was also evaluated.

AE을 이용한 Woven 구조 CFRP 적층 복합재의 손상특성 평가

  • 윤유성;권오헌
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.101-104
    • /
    • 2002
  • 직물구조 복합재료는 일방향 섬유강화복합재료에 비해 변형능력이나 인장강도가 우수하므로, 항공우주, 첨단 산업 기기에 적용될 뿐만 아니라 다른 광범위한 분야에서 사용되고 있으나 복잡한 강화구조를 가지기 때문에 그 역학적 손상거동은 파악하기가 쉽지 않다. Uetsugi 등은 직물구조 CFRP 복합재에 대하여 미세구조를 고려한 유한요소모델을 제안하여 손상진전 해석하였고, 지금까지 많은 연구자에 의해 여러 가지 수법이 제안되어져 왔으나, 아직까지 명확한 파괴거동 해석수법이 확립되어 있지 않다.(중략)

  • PDF

The Suggestion of Testing Method for Analysis of Tensile Strength of Multi-Directional GFRP Plate (다방향 GFRP 플레이트의 인장강도 분석을 위한 시험 방법 제안에 관한 연구)

  • Sim, Jong-Sung;Kwon, Hyuck-Woo;Lee, Hyoung-Ho;Kim, Hyun-Joong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.799-808
    • /
    • 2011
  • In this study, a standardized test method to analyze tensile properties of multi-directional GFRP plate was proposed. Presently, tensile strength test of FRP composite reinforced with isotropic and orthotropic fiber is standardized according to ISO standard. Also, even though many studies were performed on test method to analyze the dynamic properties, the properties of tensile strength for multi-directional GFRP plate were not clearly identified. Currently, the domestic test method in accordance with ASTM, which is applicable to unidirectional FRP plate, gave tensile test results greater than actual properties. Thus, in this study, GFRP tensile test was conducted using the method found to be commonly applicable to all standards based on literature review of domestic and international references. Then, anchorage length experiments were performed using the proposed tension test method to evaluate validity of the method. Finally, optimal anchorage length was estimated from the numerical analysis to propose the standardized tensile strength method for GFRP multi-directional composite evaluation.