• Title/Summary/Keyword: 인입온도

Search Result 18, Processing Time 0.022 seconds

A Study on Entering Water Temperature in Vertical Closed Ground Loop System Considering the Economical Feasibility in Load of the Office Building (사무시설에 수직형 지열원 냉 난방시스템의 경제성을 고려한 인입온도(EWT)에 관한 연구)

  • Lee, Byung-Doo;Lee, Dae-Woo;Lee, Se-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.579-585
    • /
    • 2009
  • Recently, Vertical-Closed Loop system using geothermal which is the most efficient among the building cooling and heating systems is coming into wide spread due to assistance of domestic policies. However, there is a limitation that a design of ground heat exchanger taking 60% of construction cost is done by GLD and GLHEPRO programs without specific guidelines and consideration on Entering Water Temperature(EWT). For getting an optimal EWT, we analyzed the costs for construction of ground heat exchanger and cooling and heating for 15 years. In the results, reduction of construction costs as the length of ground heat exchanger shortens was much greater than increase of the electrical power consumption as COP gets low. EWT that COP of heat pump can be 3.76 or above was below $31^{\circ}C$ in cooling and was over $5^{\circ}C$ in heating.

  • PDF

An Experimental Study on the Cooling Operation Characteristics for Different Entering Water Temperatures In Geothermal Heat Pump System (지열히트펌프 시스템의 EWT의 변화에 따른 냉방운전 특성에 관한 실험적 연구)

  • Ahn, Byung-Chun;Kim, Jae-Wan
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • In this paper, an experimental study on the cooling operation characteristics for different entering water temperatures in geothermal heat pump system are carried out by using Lab VIEW system program Set-point temperature controls for cooling water and supply air temperatures is applied to analyze the energy consumption and control performances. As a result, the system responses show that different entering water temperatures(EWT) effect greatly on the energy consumption and system COP.

플라즈마 동시처리 장치를 이용한 조건별 탈황$\cdot$탈질 특성

  • 심재구;박태성;장경룡;엄희문;석동찬;한영욱
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2001.05a
    • /
    • pp.98-99
    • /
    • 2001
  • B화력발전소 3호기의 배가스를 플라즈마를 이용한 탈황/탈질 동시처리기술에 적용하기 위하여 pilot-plant를 설치하고 실 배가스를 이용한 동시처리 실험을 시행하여 배가스 인입온도 $90^{\circ}C$에서 $NH_3$$SO_2$와 NOx에 대하여 0.65당량, $C_2$$H_4$를 NOx에 대하여 0.6 당량 주입하고 비전력량을 3~4 Whr/N㎥로 배가스에 인가하면, 탈황율 90%, 탈질율 70% 이상이 얻어지는 것을 확인하였다.

  • PDF

Refriferator Temperature Control Using Fuzzy Adaptive Temperature Model (퍼지적응온도모델을 이용한 냉기집중제어)

  • 김지관;이정용;이홍원
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.11a
    • /
    • pp.93-97
    • /
    • 1997
  • 본 연구는 새로운 부하(고온의 저장물)가 냉장실 내부에 인입됨에 따라 발생하는 온도불균형을 해소하기 위해 채택된 집중냉각 방식에 있어서의 회전날개의 정지각도 결정 알고리즘 관한 것으로, 특히 냉장실내의 온도에 직접적인 영향을 미치는 압축기 (Compressor) 및 냉기팬(냉기를 냉장실내에 불어넣기 위한 팬)의 운전상황을 입력으로 냉장실내 여러 영역에서의 온도를 추정하는 퍼지적응모델을 이용하여 온도불균형 영역을 검지하고, 이에 따라 회전날개의 각도를 제어함으로서 냉장실 내부의 온도평형을 신속히 이루게하는 특징을 가지고 있다.

  • PDF

On-Site Measurement of the Inlet Air Evaporative Cooling Performance for a Centrifugal Turbo Compressor (CDA 인입공기 증발냉각을 통한 압축기 성능 개선장치 개발 연구)

  • Kim, Gyu Wan;Park, Jin Ouk;Kim, Heuy Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.873-879
    • /
    • 2014
  • In the present study, water vapor is injected at various positions in a Clean Dry Air (CDA) system such as a system inlet duct, compressor inlet, and compressor outlet by humidified air turbines. The application of evaporative cooling reduces the compression work and enhances the Energy Consumption Index (ECI) per unit volume. The main purpose of this study is to investigate the compressor power performance with different inlet air temperatures and humidity conditions. It is found that the actual power consumption and discharge flow are significantly influenced by the inlet air temperature as well as relative humidity. The results obtained during this study are compared both numerically and experimentally and are found to be in very good agreement.

Optimization of Spray Drying Process for Manufacturing Dried Vinegar using Response surface methodology (분말식초제조를 위한 분무건조공정의 최적화)

  • 황성희;정용진;윤광섭
    • Food Science and Preservation
    • /
    • v.9 no.2
    • /
    • pp.194-199
    • /
    • 2002
  • This study was conducted to develop processing method for vinegar powder from natural vinegar for encapsulation applications. To optimize the spray drying process, experiment was designed by central composition method to find optimal conditions for manufacturing vinegar powder. The acidity, water absorption, solid content and heat stability of vinegar powder were selected as response variables. The optimal concentration of inclusion complex which was made with vinegar and ${\beta}$-cyclodextrin was determined on 30。bx. On increasing the concentration of ${\beta}$-cyclodextrin as a wall material, the quality of the vinegar was decreased. The optimum conditions of spray drying process for manufacturing vinegar powder were 188∼192$^{\circ}C$ and 500∼600 Lh$\^$ -1/ as inlet temperature and flow rate, respectively.

A study on the required energy of a thermal type desalination plant (증발식 해수담수화설비의 에너지 소모량에 관한 연구)

  • Song, Chi-Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1094-1100
    • /
    • 2014
  • TEvaporator is key component in food, seawater distillation and waste water treatment system, which is basically to concentrate the raw liquid by evaporating the pure water under vacuum condition. The liquid concentration is performed through the membrane, electro-dialysis and evaporation. In this study, only the evaporating type was treated for evaluating the economic analysis with the various operating conditions. The results of this study showed that the performance of the OT-MSF desalination system is increased with decreasing the temperature difference between the neighboring evaporators, which means that the number of evaporators is increased, under the determined design conditions.

Thermodynamic Analysis on the Feasibility of Turbo Expander Power Generation Using Natural Gas Waste Pressure (천연가스 폐압발전 활성화의 당위성에 대한 열역학적 분석)

  • Ha, Jong Man;Hong, Seongho;Kim, Kyung Chun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.136-142
    • /
    • 2012
  • Thermodynamic equations for the electric power and temperature in a turbo expander generator (TEG) using pressure energy in a natural gas line are derived. From the equations, it was shown that dominant factor is not the pressure difference but the pressure ratio. The high energy level in the inlet of TEG can be made from nearly no expense of electric energy input, which means TEG can be treated as one of newly available clean energy source. If a post heating method is chosen to heat up expanded natural gas, the usage of cold energy is possible without a refrigeration cycle. The combined TEG and refrigeration system enhances economic benefit much more.

A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor (적외선 센서를 이용한 열화상태 무선감시 시스템 개발)

  • Kim, Jihee;Kim, Sinwoo;Kang, Yongsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.239-245
    • /
    • 2013
  • The temperature monitoring of power cable and cable junction point is the necessary link of the safe and reliable operation of the power system. Many kinds of cables and high voltage junction points are easy to exposed continuous vibrations and momentary impulse in industry field especially power plant industries. This system can predict the overheating of the electric cable interface and the possibility of all kinds of accident, and it helps for eliminating the hazards of electric cable interface and provides the effective guarantee for the safety operation. In order to avoid the faults of the inconvenience of installation and maintenance and the high cost of application, this system used small and contactless IR sensor module. The low power consumption is used in the system. The goal of this study is the low cost and on-line reliable monitoring of power cable and junction point temperature.

Annealing behavior of the Pt films sputtered with $Ar/N_2$ gas mixture by real-time, in situ ellipsometry

  • 이동수;박동연;우현정;김승현;주한용;안응진;윤의준
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.125-125
    • /
    • 2000
  • 백금 스퍼터 증착시 아르곤에 산소와 같은 첨가 가스를 사용할 경우 산화막에 대한 접착력이 좋아지며 백금 박막의 우선배향성을 조절할 수 있음이 알려져 있다. 이러한 첨가 가스는 백금 박막에 상당량 포함되며 스퍼터링 후 열처리 과정에서 탈착되는 것으로 알려져 있다. 후열처리 도중 첨가 가스의 탈착 거동이 백금 박막의 미세구조, 조성 및 전기 전도도 등과 같은 제반 물성에 영향을 미칠 것이라 추정된다. 본 연구에서는 백금의 스퍼터링 시 질소를 첨가하여 질소가 포함된 백금 박막을 증착한 후 질소 탈착 거동을 연구하기 위해 실시간 타원해석기(in situ ellipsometer)를 이용하여 진공열처리(15mTorr)하면서 온도변화에 따른 유효굴절율(n)과 소광계수(k) 값을 구하였다. 또한 산소를 첨가하여 얻은 백금 박막의 결과와 비교하여 백금 박막내에 포함된 산소와 질소의 탈착 거동의 차이를 조사하였다. 산소를 이용하여 우선배향성이 (200)으로 조절된 박막의 경우 n과 k의 급격한 변화가 관찰되었으며 이로부터 55$0^{\circ}C$ 온도에서 산소가 급격히 빠져나감을 추측할 수 있었으며 열처리 후에는 백금 bulk 값에 가까운 값을 가짐을 알 수 있었다. 한편, 질소를 사용하여 (200)으로 우선배향성이 조절된 박막의 경우 n,k 값의 후열처리 도중의 변화 양상은 스퍼터링 압력에 크게 의존하는 것으로 나타났다. 22mTorr에서 스퍼터링한 박막의 경우 23$0^{\circ}C$ 부근에서 굴절률과 미세구조의 변화가 있음을 관찰할 수 있었으나, 10mTorr에서 스퍼터링한 시편의 경우 굴절률의 변화양상은 산소를 상요한 경우와 매우 유사한 거동을 나타내지만 열처리 후에는 상대적으로 낮은 n,k 값을 나타내고 있었다. 또한 열처리 시편의 미세구조 변화에 대한 분석 결과 산소 사용의 경우는 측정온도 범위내에서는 후 열처리 후에도 박막내에 hole이나 hillock 등이 관찰되지 않아 bulk 값에 가까운 n, k 값을 가지지만, 질소 사용의 경우는 hole, 표면 거칠기, 혹은 스퍼터링 중에 인입된 질소의 탈착이 완전히 이루어지지 못해 bulk 값과 다르게 나온 것으로 생각된다.

  • PDF