• Title/Summary/Keyword: 인성 구인

Search Result 136, Processing Time 0.027 seconds

Influence of Aggregate Factor on the Estimation of Water Content in Fresh Concrete (굳지않은 콘크리트의 단위수량 추정에 미치는 골재요인의 영향)

  • 김영득;황인성;전충근;한천구;김광서
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.223-226
    • /
    • 2002
  • This study is performed to investigate the influence of aggregate factor on the estimation of water content in fresh concrete. According to the results, water content is estimated higher in the case of basalt and granite aggregate than in the case of limestone because absorption water ratio of basalt and granite is large. As the replacement ratio of recycled aggregate increases, water content is estimated higher. But, after correcting absorption water ratio of aggregate, estimated water content is similar to mixture water content. Therefore, it is important to know the absorption water ratio of aggregates accurately, to estimate water content.

  • PDF

Influence of Mixing and Construction Factor on the Bleeding of Concrete (콘크리트의 블리딩에 미치는 배합 및 시공요인의 영향)

  • 황인성;김경민;전충근;신병철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.265-268
    • /
    • 2002
  • This study is focused on the influence of mixture and construction factor on bleeding amount of concrete According to the results, Amount of bleeding with mixture factor increases with increase of water contents and W/C. Amount of bleeding with construction factors is larger in the case of placing height of 1m than in the case of placing height of 0 and 0.5m. Amount of bleeding is larger at the temperature of 20℃ than at the temperature of 35℃ and 5℃, and increases in order of vibration compacting, standard lamping and non tamping. Therefore, to reduce bleeding, it is thought that it is profitable to reduce water content within the range that fluidity and workability don't go bad, to lower the placing height and not to do compacting too much.

  • PDF

A Review on the Determination of the Protecting Duration of Frost Damage at Early Ages in Cold Weater Concreting Based on the Analysis of Strength Development (강도증진해석에 의한 한중콘크리트의 초기동해 방지기간 설정에 관한 검토)

  • 한민철;김효구;황인성;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.179-182
    • /
    • 1999
  • A protections from the frost damage at early ages is one of the serious problems to be considered in cold weather concreting. Frost damage at early ages brings about the harmful influences on the concrete structures such surface cracks and the loss of strength. Therefore, in this paper, the protecting durations of frost damage at early ages according to the standard specifications provided in KCI(Korean Concrete Institute) are suggested by appling logistic curve, which evaluates the strength development of concrete with maturity. According to the results, as W/C and compressive strength for protecting from frost damages at early ages increased, longer protecting duration is required. It shows that the protecting durations of FAC(Fly Ash Cement) are longer than those of OPC(Ordinary Portland Cement).

  • PDF

A Fundamental Study on the Development of Precast Exposed Concrete Pannel (제치장 콘크리트용 PC패널 개발에 관한 기초 실험 연구)

  • 표대수;황인성;홍상희;전충근;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.391-396
    • /
    • 2001
  • Exposed concrete execution is utilized insufficiently due to surface honecomb and undesirable appearance by entrapped air when existing placing method is applied. Therefore, surface glossing and impact properties of cement mortar incorporating fiber glass net blast furnace slag, expansive admixture and Polypropylene fiber are investigated in order to develop precast exposed concrete pannel by dry construction method. The kinds of the forms, placing method and admixture contents are varied. According to test results, surface glossing decrease with elapse of age. Considering the form kinds, surface glossing with acryle + astage shows the best performance. Placing horizontally shows positive results in reducing surface defects such as honecomb. Impacting resistance shows the best performance when glass fiber net applied, due to the enhance in toughness and absorption of impact.

  • PDF

Properties of Fire Resistance of Concrete with Contents of Polypropylene Fiber and Specimens Size (폴리프로필렌 섬유의 혼입률 및 부재크기 변화에 따른 콘크리트의 내화 특성)

  • 전선천;황인성;이병열;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.463-468
    • /
    • 2001
  • A lot of considerations on the spatting by fire of high performance concrete should be taken into for fire resistance of the concrete structures. In this paper, fire resistance of high performance concrete is described using polypropylene fiber, which is known to be contributed to fire resistance. Strength level and member size are varied with. According to test results, spatting by fire takes place more easily, as W/C increases and member size decreases. It shows that concrete containing polypropylene fiber has good effects on preventing spatting by fire. In case high performance concrete does not contain polypropylene fiber, residual strength shows to be decreased remarkably compared :o that of normal concrete. Whereas, in case 0.1% of polypropylene fiber contents, high performance concrete shows higher residual strength than that of normal concrete. As member size is smaller, residual strength shows to be decreased.

  • PDF

Investigation on the Validities of Removal Time of the Forms Considering Rebound Number of P Type Shumidt Hammer (P형 슈미트 햄머의 반발도를 이용한 거푸집 탈형시기의 결정에 관한 타당성 검토)

  • 전충근;김상우;신병호;황인성;신병철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.909-912
    • /
    • 2001
  • This paper presents the validities of the removal time of side forms considering the relationship between rebound number of P type schmidt hammer and compressive strength. According to test results, compressive strength of 40% of W/C at 12 hours shows 16kgf/$cm^{2}$ and 50% of W/C at 15 hours, 13kgf/$cm^{2}$. Rebound number at 9 hours after casting shows 13 and 9 (W/C 40% and W/C 50%). According to the regression analysis, rebound number of P type schmidt hammer to gain 50kgf/$cm^{2}$ of is estimated 20.1. It is thought that desirable rebound number of P type schmidt hammer to gain 50kgf/$cm^{2}$ is determined 25 considering safety factor.

  • PDF

A Study on the Properties of High Fluidity Concrete Incorporating Lime Stone Powder and Fly Ash (석회석 미분말 및 플라이애쉬 치환율 변화에 따른 고유동 콘크리트의 특성에 관한 연구)

  • 조병영;윤길봉;황인성;한민철;윤기원;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.287-292
    • /
    • 2001
  • This paper investigates the properties of high fluidity concrete incorporating lime stone powder and fly ash. Lime stone powder(LSP) and fly ash(FA) contents are varied with. According to test results, as LSP and FA contents increase, fluidity, air content and placeability shows a declining tendency. For the temperature history, both LSP and FA have favorable effects on reducing hydration heat, moreover, LSP reduces hydration heat more than FA. LSP shows undesirable strength loss as its content increases. FA also decreases the strength at early age, but it enhances later age strength. Accordingly LSP is expected to improve the quality at fresh concrete and reduce hydration heat, while it causes strength loss.

  • PDF

Influence of Fine Aggregate on the Bleeding of Concrete (잔골재가 콘크리트의 블리딩에 미치는 영향)

  • 황인성;배정렬;심보길;전충근;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.317-322
    • /
    • 2001
  • This paper investigates the influence of fine aggregates on bleeding of concrete. According to test results, as water content decreases, crushed sand content increases, fluidity shows decline tendency. As for aggregates kinds, concrete using sea sand shows most fluidity loss among the tested results. Compressive strength gains highly when crushed sand is used. As for bleeding of concrete, bleeding shows decline tendency because of increasing in powder content and filling effect of voids. Bleeding amount is in a decreasing order of magnitude for concretes made with the following aggregates: sea sand, river sand, and crushed sand. Accordingly, crushed sand mixed with river sand and sea sand with certain proportion enable to reduce bleeding and enhance strength.

  • PDF

A Fundamental Study on the Estimation of Water Content in Fresh Concrete by the Heat-Drying Method (가열건조법에 의한 굳지않은 콘크리트의 단위수량 추정에 관한 기초적 연구)

  • 김영득;황인성;전충근;한천구;김광서
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.341-346
    • /
    • 2002
  • This study is intended to check the possibility to estimate water content by heat-drying method with variation of W/C and slump. According to the results, in case of electric range method, when water content is less than 165kg/m$^3$ in mixture, it is estimated more and in more than 165kg/m$^3$, it is estimated less. It shows that water content in gas burner method is estimated less by about 2kg/m$^3$. Also, estimated water content shows difference by less than 12kg/m$^3$ in electric range method and by less than 12kg/m$^3$ in gas burner method. Therefore, it is thinked that if tested without error from preparing a sample to calculating amount of water, water content will be estimated exactly in the construction field.

  • PDF

An Experimental Study on the Spatting Resistance of High Performance Concrete with PP Fiber Contents and Lateral Confinement by Metal-Lath (PP섬유 혼입 및 메탈라스 횡구속에 의한 고성능 콘크리트의 폭열방지에 관한 실험적 연구)

  • 황인성;이백수;이병열;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.557-562
    • /
    • 2002
  • This paper describes the results of spalling by fire prevention of high performance concrete confining with metal-lath and containing PP fiber. According to test results, all the specimens without PP fiber shows entire failure after exposed to fire, while the other specimens confined with metal-lath has somewhat better spatting prevention performance than plain concrete specimens, which only show surface scale spatting combination of PP fiber with confinement of metal-lath leads to favorable spatting resistance. As PP fiber contents and thickness of metal-lath which is confined at concrete specimens increase, residual strength after exposed to fire shows to be increased.

  • PDF