• Title/Summary/Keyword: 인상

Search Result 1,750, Processing Time 0.036 seconds

The Property Change of Silicone Impression Materials with Change of Storage Temperature (실리콘 인상재의 보관온도에 따른 특성변화)

  • Oh, Sang-Hwan;Moon, Seung-Kyun;Kim, Kyoung-Nam
    • Journal of dental hygiene science
    • /
    • v.10 no.6
    • /
    • pp.459-464
    • /
    • 2010
  • The purpose of this study was to evaluate the physical properties of hydrophilic polyvinyl siloxane impression materials as change of material's storage temperatures. Working time, strain-in-compression, elastic recovery and consistency were tested according to ISO Standard NO. 1563. The results are as followed. 1. Working time decreased in cold storage. 2. Strain-in-compression was different in storage temperatures. Material's strain-in compression in cold temperatures were higher than in room temperature and in incubator. 3. A coefficient of elastic recovery varied by storage temperatures. The rate in cold temperature was the lowest and in incubator was the highest. 4. Consistency of impression substance different in storage temperatures. The extent in cold temperature is the highest and in incubator was the lowest. Statistical analysis(SPSS 14.0k, p>0.05) showed that storage temperature affect to material's physical properties. We recognized that the physical properties of polyvinyl siloxane impression materials were changed according to storage temperature.

Functional impression technique using temporary denture for rehabilitation of severely atrophic maxillary and mandibular ridges (심한 치조제 흡수를 보이는 무치악 환자에서 임시 의치를 사용한 기능 인상에 의한 총의치 수복 증례)

  • Suh, Young-Kyo;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.238-244
    • /
    • 2019
  • Soft liner is used to functional impression technique when dental stone is immediately poured after taking impression because of viscoelasticity. In this case, a 78-year-old male visited for new dentures. Due to severe resorption of mandibular edentulous ridge, functional impression taking by closed mouth technique was planned. First of all, making maxillary and mandibular provisional dentures was done, and lined by soft liner to rehabilitate pressured maxillary and mandibular edentulous ridge. After this, Functional impression was taken by closed mouth technique using provisional dentures which are transformed to healed maxillary and mandibular edentulous ridge, and final denture were fabricated using maxillary provisional denture as a reference of artificial teeth arrangement. Consequently, restoring a complete edentulous patient with taking functional impression using provisional dentures resulted in recovering satisfying retention and function.

The effects of propensity of conspicuous consumption and impression management on consumer choice between hedonic and utilitarian goods: Focusing on Kakao Talk mobile gift-giving (소비자의 과시적 소비성향과 인상관리 수준에 따른 쾌락재와 실용재의 선택: 카카오톡 선물하기를 중심으로)

  • Kim, Hayea
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.117-125
    • /
    • 2022
  • This study presents product marketing strategy for mobile gift-giving by recognizing how consumers' propensity of conspicuous consumption and level of impression management affect the choice between hedonic goods and utilitarian goods. Data were collected through an online survey, and logistic regression analysis was performed using SPSS 23.0. The result of this study showed that people with high propensity of conspicuous consumption chose hedonic goods more than utilitarian goods in mobile gift-giving regardless of the level of impression management. On the other hand, those who with low propensity of conspicuous consumption chose utilitarian goods more than hedonic goods when the level of impression management was low, while these was no difference in choice between hedonic and utilitarian goods when the level of impression management was high. This study proposes to advertise in consideration of consumers' propensity of conspicuous consumption and impression management in marketing mobile gift products, especially for hedonic goods. Advertisements can appeal to consumers by using the desire to recognition or show off. Furthermore, further research can be conducted in consideration of other factors affecting gift behavior and expanding the age group.

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.

A Study on the Fitness of Adjustable Dental Impression Trays on the Chinese and Japanese (중국인과 일본인에 대한 가변형 치과 인상용 트레이의 적합성에 관한 연구)

  • Kang, Han-Joong;Lee, Jin-Han;Choi, Jong-In;Lee, In-Seop;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.175-184
    • /
    • 2008
  • Purpose: This study was designed to investigate the fitness of adjustable dental impression trays on the Chinese and the Japanese. Material and methods: Initial design of the adjustable dental trays was developed from the results of the dental arch size of Korean adults. This design was applied to the CAD-CAM process in order to create tray model samples. Simple silicon-base molds were then replicated based on these sample models. Polyurethane injection into the silicon- base molds completed the process of creating a large number of test products. 60 Chinese dental students (male:30, female:30) from the Shanghai Second Medical University and 60 Japanese alumni from the Kumamoto high school (male:30, female:30) were selected for taking irreversible hydrocolloid impression with these trays. The width and length of the impression body were measured on several measuring points by Vernier caliper. The results were analyzed statistically to evaluate the fitness of the trays. Results: 1. Uniform impression material thickness was achieved on the Chinese and Japanese by controlling the width of the tray using stops and beveled guides. The material thickness was generally within the range of 3 mm to 6 mm. 2. In the maxillary tray of the Chinese, average thickness of the impression material of the labial vestibule of the incisal teeth was 6.2 mm, the canine was 5.9 mm and the midpalatal part 10.5 mm and the posterior palatal part 9.7 mm. These were relatively large values. 3. In the mandibular tray of the Chinese, average length of the impression material of the lingual vestibule of first, second premolar contact point was 8.9 mm, the incisal teeth was 7.8 mm and thickness of the labial part of canine was 6.8 mm and premolars 7.0 mm. These were relatively large values. 4. In the maxillary tray of the Japanese, average thickness of the impression material of the labial vestibule of the incisal teeth was 7.4 mm, the canine was 7.7 mm and the midpalatal part 9.1 mm. These were relatively large values. 5. In the mandibular tray of the Japanese, average thickness of the impression material of the labial vestibule of first, second premolar contact point was 8.4 mm, and thickness of the labial part of canine was 7.4 mm. These were relatively large values. Conclusion: This adjustable dental tray shows good accuracy to Korean because it was designed by the analysis of the dental arch size of Korean adult model. With this result, it can be applied to Chinese and Japanese, we can take more easy and accurate dental impressions.

고유가정책과 석유산업

  • Sin, Ui-Sun
    • Korea Petroleum Association Journal
    • /
    • no.5 s.195
    • /
    • pp.4-7
    • /
    • 1997
  • 교통세 인상은 정유업계의 수익성 개선이나 경쟁력 강화와는 관계없고 오히려 정유사들이 유가인상의 주도자로 인식되어 국민 불만의 대상이 되기도 하였다.

  • PDF

가축분뇨 해양배출 비용 '인상' 압박

  • Korea Swine Association
    • The Korea Swine Journal
    • /
    • v.28 no.12 s.328
    • /
    • pp.141-143
    • /
    • 2006
  • 양돈농가 가축분뇨 해양배출량 감축 필요 해양 배출업체 비용인상, 분뇨 해양배출 더 어려울 듯

  • PDF

Three dimensional accuracy analysis of dental stone casts fabricated using irreversible hydrocolloid impressions (알지네이트 인상체에서 제작된 치과용 석고 모형의 정확도에 대한 삼차원 디지털 분석)

  • Joo, Young-Hun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.4
    • /
    • pp.316-328
    • /
    • 2015
  • Purpose: The objects of this study was to evaluate the accuracy of the dental stone casts made from alginate impressions according to storage condition and stone pouring time. Materials and Methods: Each of upper and lower impressions of dental model was taken. The dental stone models were made immediately, 10, 30, 60, 180, 360 minutes after the impressions were taken at each storage condition. 3D models were constructed by scanning the stone model using 3D laser scanner. With Reference points, positioned on digital models, linear measurements of the dimensional change were compared by 3D metrology software, 3D average models were made and superimposition to identify the specific site of dimensional change and to measure surface deviation (mm). Results: Dental stone models which were made immediately after taking the impression showed the smallest linear dimensional change. As the stone pouring time was prolonged, the linear dimensional change was increased. More than 180 minutes after impression taking, linear dimensional change and surface distortion increased in the posterior molar region, regardless of the storage condition. Conclusion: For the optimum accuracy of the dental stone casts, alginate impression should be poured as soon as possible. If there were a need for storing, a humidor with 100% relative humidity must be used and be stored less than 180 minutes to fabricate the accurate dental model.