• 제목/요약/키워드: 인버터 에어컨

검색결과 42건 처리시간 0.023초

분리형 인버터 에어컨의 운전조건에 따른 성능 연구 (A study on the performance of a split system inverter air-conditioner at different operation conditions)

  • 김만회
    • 대한기계학회논문집B
    • /
    • 제22권1호
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

백색가전용 모터 드라이브 기술

  • 이욱진
    • 전력전자학회지
    • /
    • 제27권3호
    • /
    • pp.49-53
    • /
    • 2022
  • 우리나라의 백색가전 산업은 1960년대 말 시작된 이후 현재에 이르러는 국내는 물론 전 세계 시장에서도 높은 점유율을 기록하고 있다. 3대 백색가전 제품인 세탁기, 냉장고, 에어컨 기준 연간 수천만 대에 이르는 국내 가전 업체들의 생산량을 고려하면, 백색가전 산업에서의 모터 및 인버터 생산량은 타 산업 대비 압도적인 수량이다. 세탁기, 냉장고, 에어컨뿐만 아니라 건조기, 청소기, 식기세척기 등 거의 모든 가전제품에서 1개 혹은 그 이상의 모터들의 구동으로 제품의 주요기능들이 작동되고 있으므로 모터 및 모터 드라이브 기술은 제품의 성능과 가격 경쟁력을 결정하는 중요한 부분이라고 할 수 있다. 본 글에서는 백색가전 제품의 주요 제품군들 내에서 사용되고 있는 모터 드라이브 기술의 특징을 소개하고자 한다.

다중 퍼지 제어기의 최적 설계와 에어컨 시스템으로의 적용 (Optimal Design of Multi-Fuzzy Controller and Its application to Air Conditioning System)

  • 장한종;최정내;오성권
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국지능시스템학회 2008년도 춘계학술대회 학술발표회 논문집
    • /
    • pp.313-316
    • /
    • 2008
  • 에어컨 시스템은 압축기(Compressor), 응축기(Condenser), 증발기(Evaporator)와 확장밸브(Expansion Valve)로 구성되며, 에어컨 시스템에서 과열도와 저압(증발기의 압력)은 시스템의 효율 증대 및 성능 개선과 안정성에 대하여 결정적인 영향을 미친다. 따라서, 과열도와 저압을 조절하기 위해, 각각의 압축기내의 인버터 주파수와 확장밸브의 개도 제어가 중요하며 선형과 비선형 시스템 모두에 대하여 견실한 성능을 나타내고, 외란에 대하여 강인한 성능을 보이는 퍼지 제어기를 설계한다. 본 논문에서는 과열도와 저압을 제어하기 위하여, 3대의 확장밸브와 1대의 압축기를 가진 에어컨 시스템에 대하여 다중 퍼지 제어기를 설계한다. 또한, 각 제어 플랜트에 대하여 최적의 퍼지 제어기를 설계하기 위하여 3가지 최적화 알고리즘을 사용한다. 즉, 직렬 유전자 알고리즘(Serial Genetic Algorithm; SGA)과 병렬 유전자 알고리즘인 계층적 공정 경쟁 유전자 알고리즘(Hierarchical Fair Competition Genetic Algorithm; HFCGA), 그리고 Particle Swarm Optimization(PSO)을 사용하여 다중 퍼지 제어기를 최적화하고 시뮬레이션의 결과를 비교한다.

  • PDF

대용량 상업용 에어컨의 고조파 저감을 위한 Active Power Filter 시스템 개발 (Active Power Filter System for Harmonics Reduction of Large Capacity Commercial Air-Conditioner)

  • 이동근;채승우;이용화;오정언;정달호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 전력전자학술대회 논문집
    • /
    • pp.511-512
    • /
    • 2016
  • 최근 대다수의 상업용 에에컨 분야에서는 제품의 효율 상승 및 운전 영역 확대]를 위해 대용량 고효율 인버터를 사용하고 있으며, 이로 인해 계통 입력 전류의 고조파 성분이 증가하여 역률 저하, 발열 뿐만 아니라 여러 가지 계통 사고의 원인이 되고 있다. 본 논문에서는 인버터가 적용된 대용량 상업용 에어컨의 입력 전류 고조파 성분을 저감하기 위한 3상용 Active Power Filter 시스템 기술을 제안한다. 또한 제안된 시스템을 설제 제품에 적용함으로써 계통 압력 전류의 고조파 저감 성능을 확인 하였다.

  • PDF

가전기기용 교류 전동기 구동 시스템의 EMI 특성 및 필터 설계 (EMI Characteristics and filter design of AC Drives for Home Appliances)

  • 정세교;신휘범
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.81-87
    • /
    • 2004
  • 본 논문에서는 세탁기, 에어컨과 같은 가전기기에 사용되는 인버터 구동 교류 전동기 구동 시스템의 EMI 특성해석 및 필터 설계 방법에 대하여 기술하였다. 먼저, 인버터 구동 교류 전동기 구동 시스템의 전도성 EMI 발생 및 전달 메커니즘에 대하여 분석하였고, 공통 및 차동모드 노이즈 분리 기법을 이용한 EMI 필터의 설계 방법을 제시하였다. 제시된 방법의 타당성을 검증하기 위해 PWM 인버터로 구동되는 유도 전동기 구동 시스템에 대한 실험을 수행하였고 EN55014 EMI 기준을 만족하는 결과를 얻을 수 있었다.

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

PWM 방식과 인버터 방식의 압축기를 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(냉난방 특성) (Experimental Study on Performance Evaluation of System Air-Conditioner using Compressor of PWM or Inverter Method (Cooling and Heating Characteristics))

  • 전용호;김대훈;허삼행;권영철;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권9호
    • /
    • pp.738-743
    • /
    • 2003
  • In the present study, the heating and cooling characteristics of system air-conditioner using a PWM compressor or a BLDC inverter compressor are investigated by the psychometric calorimeter using air enthalpy method. Cooling and heating capacities, power inputs and COPs are measured at the low, moderate, high loads under the cooling and heating standard conditions. At cooling conditions, the capacity of the PWM system is larger than that of the inverter case. Due to large power input, however, low COPs are measured under total load ranges. At heating conditions, the capacity of the PWM method is a little larger than that of the inverter case, except high load range. Since power input is low, large COPs are measured at moderate and high load ranges, which are different from cooling data. This shows that the PW system compared with the inverter case has good energy consumption efficiency at moderate and high load ranges except low load range. And when the system A/C is operated under the cooling and heating standard conditions, COPs are nearly uniform at total load ranges.

PWM 방식과 인버터 방식을 사용한 시스템 에어컨의 성능평가에 대한 실험적 연구(난방저온 특성) (Experimental Study on Performance Evaluation of System A/C using PWM or Inverter Method (Heating Characteristics at Low Temperature Conditions))

  • 김대훈;전용호;권영철;이윤수;문제명;홍주태
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.551-556
    • /
    • 2003
  • The present study concerns an experiment on the heating characteristics of a system air-conditioner (A/C) using PWM method or inverter method at low temperature con-ditions. The compressors used are digital scroll type and BLDC inverter type. Under the low outside temperature condition, -5$^{\circ}C$, -1$0^{\circ}C$, -15$^{\circ}C$, heating capacities and COPs are mea-sured by the psychometric calorimeter using air enthalpy method. Also, outlet air temperatures at heating operation mode are measured at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$. Experimental results show that COPs of the system A/C using a PWM method are more effective than those of the inverter method at heating operation mode. Although the heater is on, COPs of PWM method are similar to those of BLDC inverter method. Moreover, the heating capacities of PWM method at -5$^{\circ}C$, -1$0^{\circ}C$ and -15$^{\circ}C$ are larger about 10~20% and outlet air tempe-rature at -15$^{\circ}C$ is larger about 10%, compared to the inverter method.

ARM Cortex-M4 마이크로컨트롤러를 사용한 유도전동기의 저가형 벡터제어 인버터 설계 (The Design of Low-Cost Vector-Controlled Inverter for Induction Motor Using ARM Cortex-M4 Microcontroller)

  • 김동기;윤덕용
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.816-821
    • /
    • 2013
  • 본 논문은 ARM Cortex-M4 마이크로컨트롤러를 사용하여 3상 유도전동기용의 저가형 벡터제어 인버터를 설계하는 방법을 제안한다. 이 MCU는 냉장고, 에어컨, 세탁기와 같은 가전제품을 제어하기 위하여 기존의 값비싼 DSP 소자를 대신할 수 있다. 본 논문에서는 전동기 제어에 필요한 Cortex-M4의 주요 기능들을 정리하고, 이를 사용하여 벡터제어 인버터를 설계하는 방법을 기술한다. 실험용 벡터제어 인버터를 설계 제작하여 200[W]의 3상 유도전동기에 적용하였고, 이를 사용한 실험 결과는 기존의 TMS320F28335 DSP와 유사한 수준의 제어 성능을 보였다.

랜덤 PWM을 이용한 왕복동식 압축기의 전자기소음 저감 (Electromagnetic Noise Reduction of Reciprocating Compressor using Random PWM)

  • 조관열;양순배;김학원
    • 전력전자학회논문지
    • /
    • 제5권2호
    • /
    • pp.200-207
    • /
    • 2000
  • 근래 에어컨, 냉장고 및 세탁기와 같은 가전 전기제품에도 전력소비의 저감, 저속운전에 의한 소음저감 및 인간에게 보다 안락한 기능을 제공하기 위하여 인버터 시스템의 적용이 증가되고 있다. 그러나 인버터 시스템은 PWM에 의해 불필요하게 발생되는 전자기소음의 저감과 소음의 질에 대한 감성소음의 개선이 요구된다. 본 논문에서는 브러쉬없는 직류전동기로 구동되는 왕복동식 압축기에 대하여 고정 PWM과 랜덤 PWM의 전자기소음 분석을 통하여 인버터 냉장고에 랜덤 PWM을 적용함으로써 전자기소음의 저감 및 감성소음의 개선효과가 있음을 실험을 통하여 검증하였다.

  • PDF