• Title/Summary/Keyword: 인공물

Search Result 1,875, Processing Time 0.027 seconds

Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T. (강자성 인공물 발생에 대한 자기공명영상 질 평가: 1.5T와 3.0T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.193-199
    • /
    • 2018
  • In this research, 15 patients were diagnosed with 1.5T and 3.0T MRI instruments (Philips, Medical System, Achieva) to minize Ferromagnetic artifact and find the optimized Tesla. Based on the theory that the 3.0T, when compared to 1.5T, show relatively high signal-to-ratio(SNR), Scan time can be shortened or adjust the image resolution. However, when using the 3.0T MRI instruments, various artifact due to the magnetic field difference can degrade the diagnostic information. For the analysis condition, area of interest is set at the background of the T1, T2 sagittal image followed by evaluation of L3, L4, L5 SNR, length of 3 parts with Ferromagnetic artifact, and Histogram. The validity evaluation was performed by using the independent t test. As a result, for the SNR evaluation, mere difference in value was observed for L3 between 1.5T and 3.0T, while big differences were observed for both L4, and L5(p<0.05). Shorter length was observed for the 1.5T when observing 3 parts with Ferromagnetic artifact, thus we can conclude that 3.0T can provide more information on about peripheral tissue diagnostic information(p<0.05). Finally, 1.5T showed higher counts values for the Histogram evaluation(p<0.05). As a result, when we have compared the 1.5T and 3.0T with SNR, length of Ferromagnetic artifact, Histogram, we believe that using a Low Tesla for Spine MRI test can achieve the optimal image information for patients with disk operation like PLIF, etc. in the past.

Water Budget Analysis for the Target Area Assessment of Groundwater Artificial Recharge (지하수 인공함양 대상지역 평가를 위한 물수지적 접근 방안)

  • Kim, Gyoo-Bum;Hwang, Chan-Ik;Choi, Myoung-Rak
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.24-24
    • /
    • 2020
  • 전세계적으로 지하수 인공함양은 기후변화로 인한 극한가뭄 시대에 효율적인 물확보 방안으로 평가되고 있는 기술로서, 우리나라에서도 2015년 충청 및 강원 지역의 극한 가뭄이 발생한 이후 그 필요성이 증대되고 있다. 지하수 인공함양 대상지역의 평가를 위해서는 물의 수요에 대한 진단, 대상지역의 수리수문학적 특성, 지층의 인공함양 가능성, 원수의 확보 여부, 현행 공급 능력의 진단 등이 복합적으로 이루어져야 한다. 충청남도 홍성군 갈산면 신곡마을은 안정적인 농업용수 공급 시스템이 마련되어 있지 않아 상시 가뭄지역으로서 현행 지하수 관정에 의한 취수능력으로는 주기적인 물 부족이 발생하는 지역이며, 대용량의 암반 지하수 관정 개발도 대수층의 특성상 거의 불가능하다. 따라서, 인공함양의 원수로서 하천수 또는 함양영역 밖의 소용량의 암반 지하수를 고려할 수 있다. 월별 물수지 분석 결과, 농번기 초기인 4월에는 수요량 대비 기존 용수원(관정)에 의한 공급량이 충분하여 99 ㎥/d의 여유가 존재하나, 5월에는 215 ㎥/d의 물부족이 발생하게 된다. 반면에, 하천유출량은 3월 1,297 ㎥/d, 4월 2,899 ㎥/d 등으로서 함양원수로 사용하기에 충분한 수량이 존재할 뿐 아니라, 이 기간의 지하수위가 지표하 약 4~5 m 하부에 위치하고 있어 지하수 함양에 충분한 공간도 확보되는 것으로 평가되었다. 향후 추가적인 정밀한 수치모델링을 통하여 지하수 인공함양을 위한 적정 물량, 지하수위의 분포 변화 예측, 적정 취수량의 결정 등을 수행할 예정이다.

  • PDF

Staged Damage Detection of a RC Mock-up Structure by Artificial Neural Network (인공신경망을 이용한 RC Mock-up 구조물의 단계별 손상탐지)

  • Kwon, Hung-Joo;Kim, Ji-Young;Yu, Eun-Jong
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.676-679
    • /
    • 2011
  • 인공신경망(Artificial Neural Network)을 이용하여 RC Mock-up 구조물의 손상위치 및 손상정도를 단계적으로 추정하였다. 대상 구조물은 가진실험을 통하여 구조물의 응답을 취득하고 구조물식별기법(Structural System Identification)을 통하여 구조물의 동특성을 찾았다. 유한요소해석프로그램을 사용하여 동특성이 계측치와 가장 유사한 기본해석모델을 만든 후 이 기본해석모델을 이용하여 학습데이터를 생성하였다. 기존 인공신경망을 이용한 손상탐지를 개선하고자 본 연구에서는 인공신경망 학습데이터를 분석하였고 효과적인 손상탐지를 위하여 학습데이터를 가공하였다. 가공된 학습데이터를 사용하여 단계별 손상탐지를 실시하였고 기존 손상탐지 방법보다 좋은 결과를 유도하였다.

  • PDF

장내 가수분해조건에 의한 Casein 가수분해물의 Angiotensin Converting Enzyme 저해 효과

  • Hwang, Yu-Jin;Yang, Hui-Jin;Do, Jeong-Ryong;Lee, Su-Won
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.290-293
    • /
    • 2005
  • 장내 단백질 가수분해효소에 의한 casein 분해산물들의 ACE 저해 활성을 비교하기 위하여 인공위액, 인공장액 및 인공위액과 장액 연속처리를 각각 반응조건으로 일정시간 casein을 가수분해한 후 각 효소 가수분해물이 혈압상승 peptide 생성효소인 Angiotensin converting enzyme(ACE)에 대한 저해활성을 측정하였다. 각 소화액에 따른 가수분해물은 모두 ACE 저해활성을 나타내었으며, 2시간 효소처리를 하였을 때, 인공위액, 인공장액, 인공위액과 장액 가수분해물은 각각 69%, 80% 및 88%로 최대 ACE 저해활성을 보였다. 그리고 casein의 가수분해 정도를 확인하기 위한 SDS-PAGE에서는 인공위액으로 처리한 군보다 인공장액으로 처리한 군이 더 작은 분자량으로 분해되는 것을 확인할 수 있었고, 인공위액과 장액을 함께 처리한 군에서는 1시간 안에 대부분의 분해가 이루지는 것을 관찰할 수 있었다.

  • PDF

Study of crystal structure of La-modified $SrTiO_3$ artificial oxide Suprerlattice (La-modified $SrTiO_3$ 산화물 인공격자의 결정구조 분석)

  • 윤경선;이재찬;이광렬
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2003.11a
    • /
    • pp.162-162
    • /
    • 2003
  • 최근에 산화물 인공격자의 우수한 특성으로 인하여 활발한 연구가 진행되고 있다. 본 연구에서는 펄스레이저 증착방법을 이용하여 산소분압 100mTorr, $650^{\circ}C$에서 LSCO/MgO 기판위에 La-50mol% 첨가된 SrTiO$_3$ (SLTO)와 SrTiO$_3$ 를 적층시켜 산화물 인공격자를 만들어 결정구조에 대하여 연구하였다. SrTiO$_3$ (STO)는 상온에서 3.904$\AA$인 cubic perovskite 구조를 가지고 있다. 일반적으로 La$^{3+}$ (1.14$\AA$)은 Sr$^{2+}$(1.12$\AA$)과 이온반경이 거의 유사하기 때문에 ABO 페로브스카이트 구조의 A자리에 치환될 것으로 기대되며 또한 Sr$^{2+}$ 자리에 La$^{3+}$ 가 치환되므로써 발생하는 charge compensation은 Sr 자리에 Vacancy 생성으로 판단된다. 인공격자의 성장확인을 위하여 SLTO와 STO를 10층씩 증착하여 XRD분석을 통하여 평가하여 보았다. 확인된 결과를 바탕으로 산화물 인공격자의 적층 주기를 SLTO layer를 한층으로 고정시키고 STO를 한 층에서 다섯 층까지 다양하게 변화시켰다. 본 연구의 목적은 산화물 인공격자에서 결정결함을 제어하여 소자에 응용할 수 있는 전기적 물성을 평가하기 위함이다. X-ray diffraction 결과 SLTO/STO 인공격자는 (001) 방향으로 우선배향하였으며 적층주기에 따라 격자상수의 변화를 보였다. AES의 depth profile 분석을 통하여 La의 분포를 확인하였으며, HRTEM 분석을 통하여 미세구조분석을 실시하였다.

  • PDF

Flow Characteristics of the Artificial Upwelling Structure by Porosity Change (공극률 변화에 따른 인공용승류 특성)

  • Lee, Hwang Ki;Kim, Young Min;Kim, Jong Kyu
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.20 no.2
    • /
    • pp.100-106
    • /
    • 2017
  • Artificial upwelling structure has been set up in sea mount. Bottom water can upwelling euphotic zone. Plentiful nutrient included in bottom water could not only enhance primary production but also expect food chain reaction and gathering fish. This study explain flowing features subject to porosity changes according to the material and shape of artificial upwelling structure. As a result, the upward flux is getting decreased while the porosity is increasing. And it figured out when the upward flux was decreased, the downward flux was also decreased. Futhermore, it was confirmed that the best efficiency of upwelling flux was shown up when the porosity was 10% according to the volume of artificial upwelling structure in case of 20% of porosity, it also has a good efficiency in comparison with impermeable artificial upwelling structure. Therefore, to build the artificial upwelling structure, It is encouraged to design it less than 20% of porosity for the best performance.

인공용승구조물의 수리학적 특성에 관한 기초적 연구

  • 김홍진;류청로
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2002.10a
    • /
    • pp.170-172
    • /
    • 2002
  • 해양의 수산자원개발을 위한 새로운 기술의 하나로 용승어장효과를 인공적으로 재현하여 어업생산성을 도모하기 위해 설치되는 인공용승구조물의 수리학적 특성을 검토하고 용승유량에 관한 기본적인 특성에 대해 연구하였다. 대상 인공용승구조물의 구조형식은 블록을 이용한 잠제 형식이며, 블록의 모양은 정육면체이다. 본 연구를 통해서 용승구조물의 용승유량 특성을 검토하고자 한다. (중략)

  • PDF

The Evaluation of Imaging Quality Depending the Shift of the Central Axis in FOCUS DWI Investigation (Focus DWI 검사에서 중심축 이동에 따른 화질 평가)

  • Kim, Younghwa;Jeong, Moontaeg;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.631-636
    • /
    • 2018
  • The problem that the existing the magnetic resonance image (MRI) was prone to have not only long readout duration and low bandwidth in the phase-encode direction, but also geometric distortion was pointed out. The purpose of this study is to identify the usefulness of FOCUS-DWI through comparing FOCUS-DWI with the Conventional-DWI on a degree of uniformity and artifacts caused by the distance change in the central axis within the magnetic field. In terms of artifacts, there happened irregular striped artifacts in the Conventional-DWI technique, which in particular, more often arose in the central axis. Also, the overlap of imaging drastically increased. By contrast, there were no irregular striped artifacts in the FOCUS-DWI technique. In conclusion, it was found that the FOCUS-DWI technique was superior to the Conventional-DWI technique in terms of artifacts, the overlap of imaging, and a degree of uniformity. In addition, there was no difference of the change in distance from the central axis between the FOCUS-DWI technique and the Conventional-DWI technique. Thus, it is considered the FOCUS-DWI technique having less imaging distortion and high image quality will be highly clinically used.

Assesment Of Image Quality in the Abdominal Magnetic Resonance Imaging: Comparison with 1.5 T and 3.0 T (복부 자기공명영상에서 영상의 질 평가: 1.5 T 와 3.0 T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.367-373
    • /
    • 2016
  • This study conducted an analysis to compare the differences in the properties of the magnetic field and the generation of artifacts because of the difference in the magnetic field between 1.5 T equipment and 3.0 T equipment, centering around four types of pulse sequences, mainly applied to the abdominal Magnetic Resonance Imaging (MRI). With data on 500 persons transmitted to the PACS, this study analyzed the SNR value, quantitatively and carried out a qualitative evaluation, dividing MSA, CSA, and DA into three steps. As a result of the quantitative evaluation, the SNR value was significantly higher in the 1.5 T equipment; however, there was a factor deteriorating the image quality, too, as artifacts were generated in the images. The 1.5 T equipment generated fewer artifacts than the 3.0 T equipment did, so it could compensate the image quality for 3.0 T. In conclusion, based on these findings, this study could understand the differences in the properties of the magnetic field and the generation of artifacts occurring because of the difference in the magnetic field and could provide a measure for them. This study would be guidelines for MRI users who directly examine the patients in abdominal MRI using the two types of equipment in the clinical setting in the future.

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.