• Title/Summary/Keyword: 이형도

Search Result 7,136, Processing Time 0.05 seconds

Chronic Dialysis in Infants and Children Under 2 Years of Age (2세 미만 만성 신부전 환아에서의 만성 투석)

  • Sohn, Young-Bae;Nam, Sook-Hyun;Kwak, Min-Jung;Kim, Su-Jin;Jin, Dong-Kyu;Paik, Kyung-Hoon
    • Childhood Kidney Diseases
    • /
    • v.11 no.1
    • /
    • pp.41-50
    • /
    • 2007
  • Purpose : Dialysis in children with chronic renal failure presents with many difficulies. The purpose of this study is to find an improved method in chronic dialysis in infants and children less than 2 years of age by analyzing the experience with 10 cases. Methods : A retrospective review of the medical records of 10 patients(6 boys and 4 girls) was conducted. The patients had chronic renal failure and underwent chronic dialysis at Samsung medical center from March 1999 to February 2007. Results : At Initiation of dialysis, the median age was 3 months old(22 days-20 months), the median body weight was 3.75 kg(2.2-10.3 kg), and the median serum creatinine level was 4.3 mg/dL(2.0-11.4 mg/dL). The median duration of dialysis was 29.5 months(3-62 months). Dysplastic kidney disease was the most common underlying renal disease. Two patients were treated with hemodialysis, 4 patients with peritoneal dialysis, and 4 patients eventually switched dialysis modality. Nine of the 10 patients took erythropoietin and anti-hypertensive drugs. At the end of the follow up period, 1 patient received kidney transplantation, 2 patients died due to sepsis, and 5 patients were treated with peritoneal dialysis. Two patients were lost to follow up. The most common complication of dialysis was infection. Achieving vascular access and maintaining proper catheter function were the most important factors in treating patients with hemodialysis. The growth status of patients was aggravated after 6 month of dialysis but improved after 1 year of dialysis. Patients showed better growth on peritoneal dialysis than hemodialysis. Conclusion : Chronic dialysis can be performed successfully in infants and children under 2 years of age. Vascular access was the main limitation of hemodialysis, and infection was the common problem in both hemodialysis and peritoneal dialysis. To improve the patients survival rate and quality of life, major efforts should be directed toward the prevention of infection and preservation of catheter function. (J Korean Soc Pediatr Nephrol 2007;11:41-50)

  • PDF

Effects of Gamma-Irradiation on the Sterilization of Primordial Germ Cells in Quail (메추리 원시생식세포 감소를 위한 감마선 조사의 효과)

  • Park, Kyung-Je;Kim, Tae-Min;Lee, Hyung-Chul;Jang, Hyun-Jun;Song, Gwon-Hwa;Han, Jae-Yong
    • Korean Journal of Poultry Science
    • /
    • v.37 no.2
    • /
    • pp.139-143
    • /
    • 2010
  • Quail is a very useful animal model for studying vertebrate development because of its small body size and unique reproductive traits. This species is also ideal model for producing germline chimeras via transferring exogenous primordial germ cells (PGCs) into the recipient embryo. To increase the contribution efficiency of donor PGCs into recipients' tissues, decreasing the population of endogenous PGCs has been rate-limiting factor. We therefore conducted this study to investigate if gamma ($\gamma$)-irradiation depletes endogenous PGCs in developing quail embryo. Firstly, freshly laid stage X quail embryos were irradiated with various output of $\gamma$-irradiation and its teratogenic effect on the embryo was evaluated. Although a dose-dependent increase in the number of embryo showing malformation was found as the output increased (0, 250, 500, 750, and 1,000 rads), only a maximum of 10.1% of embryos were abnormal in 1,000 rads. Immunocytochemical analysis using the QCR1 antibody, which is specific marker for quail PGCs, was conducted to analyze the effect of sterilization. As results, $\gamma$-rays at a dose-rate of 500 rads/73 sec onto undeveloped stage X embryo significantly reduced the number of germ cells to an average of 75.55 % and 82.03 % in male and female embryos, respectively. We conclude that $\gamma$-ray selectively targets PGCs while affects minimally to the somatic development in quail embryo. Our results will not only provide important data for germline chimera production but can be used for analyzing the effect of ionized rays on the differentiating germ cells in various stages during animal development.

The Study of Reducing Radiation Exposure Dose and Comparing SUV According to Applied IRIS (Iterative Reconstruction in Image Space) for PET/CT (PET/CT 검사 시 IRIS (Iterative Reconstruction in Image Space) 적용에 따른 CT 피폭선량 감소와 PET SUV 비교 연구)

  • Do, Yong Ho;Song, Ho Jun;Lee, Hyung Jin;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.29-34
    • /
    • 2012
  • Purpose : Presently, hardwares and softwares for reducing radiation exposure are continually developed for PET/CT examination. Purpose of this study is to evaluate effectiveness of reducing radiation exposure dose of CT and SUV changes of PET when applied each kernel to ACCT (Attenuation Correction Computed Tomography) according to adopted IRIS (Iterative Reconstruction in Image Space) software. Materials and Methods : Biograph mCT (Siemens, Germany) was used as a PET/CT scanner. Using AAPM CT performance phantom, from standard (120 kVp, 100 mAs), 7 scans were conducted by reducing 15 mAs each. After image reconstruction by FBP (Filtered Back Projection) and IRIS, noise and spatial resolution were evaluated. The same method was applied to anthropomorphic chest phantom and acquired images were compared. NEMA IEC body phantom was used for SUV evaluation. Injected dose rate for hot sphere (hot) and background cylinder (BKG) were 1:8. CT dose condition (120 kVp, 50 mAs) was the same for each scan and PET scan durations were 1, 2, 3 and 4min. After scanning, each kernel of IRIS was applied to ACCT. And PET images were reconstructed by ACCT adopted IRIS for comparing SUV changes. Results : AAPM phantom test for noise evaluation, SD for FBP 100 mAs, IRIS 55 mAs were 8.8 and 8.9. FBP 85 mAs, IRIS 40 mAs were 9.5 and 9.7. FBP 70 mAs, IRIS 25 mAs were 11.9 and 11.1. Above mAs condition for FBP and IRIS, SD showed similar values. And for spatial resolution test, there was no significant difference. For chest phantom test, when applied the same mAs and kernel to both of FBP and IRIS, every applied kernels showed reduced noise. Lower mAs and higher kernel value showed higher noise reduction. There was no considerable difference only except for I70 very sharp kernel for SUV comparison using NEMA IEC body phantom. Conclusion : In this study, low mAs (55 mAs) applied IRIS and standard mAs (100 mAs) applied FBP showed similar noise. And only except for I70 kernel, there was no significant SUV changes. It is possible to reduce needless radiation exposure and acquire better image quality than FBP's through applying appropriate kernel of IRIS to PET/CT.

  • PDF

The Understanding and Application of Noise Reduction Software in Static Images (정적 영상에서 Noise Reduction Software의 이해와 적용)

  • Lee, Hyung-Jin;Song, Ho-Jun;Seung, Jong-Min;Choi, Jin-Wook;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.54-60
    • /
    • 2010
  • Purpose: Nuclear medicine manufacturers provide various softwares which shorten imaging time using their own image processing techniques such as UlatraSPECT, ASTONISH, Flash3D, Evolution, and nSPEED. Seoul National University Hospital has introduced softwares from Siemens and Philips, but it was still hard to understand algorithm difference between those two softwares. Thus, the purpose of this study was to figure out the difference of two softwares in planar images and research the possibility of application to images produced with high energy isotopes. Materials and Methods: First, a phantom study was performed to understand the difference of softwares in static studies. Various amounts of count were acquired and the images were analyzed quantitatively after application of PIXON, Siemens and ASTONISH, Philips, respectively. Then, we applied them to some applicable static studies and searched for merits and demerits. And also, they have been applied to images produced with high energy isotopes. Finally, A blind test was conducted by nuclear medicine doctors except phantom images. Results: There was nearly no difference between pre and post processing image with PIXON for FWHM test using capillary source whereas ASTONISH was improved. But, both of standard deviation(SD) and variance were decreased for PIXON while ASTONISH was highly increased. And in background variability comparison test using IEC phantom, PIXON has been decreased over all while ASTONISH has shown to be somewhat increased. Contrast ratio in each spheres has also been increased for both methods. For image scale, window width has been increased for 4~5 times after processing with PIXON while ASTONISH showed nearly no difference. After phantom test analysis, ASTONISH seemed to be applicable for some studies which needs quantitative analysis or high contrast, and PIXON seemed to be applicable for insufficient counts studies or long time studies. Conclusion: Quantitative values used for usual analysis were generally improved after application of the two softwares, however it seems that it's hard to maintain the consistency for all of nuclear medicine studies because result images can not be the same due to the difference of algorithm characteristic rather than the difference of gamma cameras. And also, it's hard to expect high image quality with the time shortening method such as whole body scan. But it will be possible to apply to static studies considering the algorithm characteristic or we can expect a change of image quality through application to high energy isotope images.

  • PDF

The Study of New Reconstruction Method for Brain SPECT on Dual Detector System (Dual detector system에서 Brain SPECT의 new reconstruction method의 연구)

  • Lee, Hyung-Jin;Kim, Su-Mi;Lee, Hong-Jae;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of $^{99m}Tc$-HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.

  • PDF

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

Recombination and Expression of VP1 Gene of Infectious Pancreatic Necrosis Virus DRT Strain in a Baculovirus, Hyphantria cunea Nuclear Polyhedrosis Virus (전염성 췌장괴저바이러스 DRT Strain VP1유전자의 Baculovirus Hyphantria cunea Nuclear Polyhedrosis Virus에 재조합과 발현)

  • Lee, Hyung-Hoan;Chang, Jae-Hyeok;Chung, Hye-Kyung;Cha, Sung-Chul
    • The Journal of Korean Society of Virology
    • /
    • v.27 no.2
    • /
    • pp.239-255
    • /
    • 1997
  • Expression of the cDNA of the VP1 gene on the genome RNA B segment of infectious pancreatic necrosis virus (IPNV) DRT strain in E. coli and a recombinant baculovirus were carried out. The VP1 gene in the pMal-pol clone (Lee et al. 1995) was cleaved with XbaI and transferred into baculovirus transfer vector, pBacPAK9 and it was named pBacVP1 clone. The VP1 gene in the pBacVP1 clone was double-digested with SacI and PstI and then inserted just behind T5 phage promoter and the $6{\times}His$ region of the pQE-3D expression vector, and it was called pQEVPl. Again, the $6{\times}$His-tagged VP1 DNA fragment in the pQEVP1 was cleaved with EcoRI and transferred into the VP1 site of the pBacVP1, resulting pBacHis-VP1 recombinant. The pBacHis-VP1 DNA was cotransfected with LacZ-Hyphantria cunea nuclear polyhedrosis virus (LacZ-HcNPV) DNA digested with Bsu361 onto S. frugiperda cells to make a recombinant virus. One VP1-gene inserted recombinant virus was selected by plaque assay. The recombinant virus was named VP1-HcNPV-1. The $6{\times}$His-tagged VP1 protein produced by the pQEVP1 was purified with Ni-NTA resin chromatography and analyzed by SDS-PAGE and Western blot analysis. The molecular weight of the VP1 protein was 94 kDa. The recombinant virus, VP1-HcNPV-1 did not form polyhedral inclusion bodies and expressed VP1 protein with 95 kDa in the infected S. frugiperda cells, which was detected by Western blot. The titer of the VP1-HcNPV-1 in the first infected cells was $2.0{\times}10^5\;pfu/ml$ at 7 days postinfection.

  • PDF

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Isolation and Characterization of the IAA Producing Methylotrophic Bacteria from Phyllosphere of Rice Cultivars(Oryza sativa L.) (벼(Oryza sativa L.)의 잎 면으로부터의 IAA를 생성하는 Methylotrophic Bacteria의 분리 선별 및 특성 비교)

  • Lee, Kyu-Hoi;Munusamy , Madhaiyan;Kim, Chung-Woo;Lee, Hyoung-Seok;Selvaraj, Poonguzhali;Sa, TongMin
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.37 no.4
    • /
    • pp.235-244
    • /
    • 2004
  • In this study, we compared the levels of methylotrophic bacterial community diversity in the leaf samples of 19 rice cultivars collected from three regions of Korea. Nineteen pink pigmented isolates showing characteristic growth on methanol were obtained. Physiological and biochemical characters of each isolate were examined according to methods described in Bergey's Manual of Systematic Bacteriology. When phylotypes were defined by performing numerical analysis of 37 characteristics, four distinct clusters were formed. The two reference strains, Methylobacterium extorquens AM1 and Methylobacterium fujisawaense KACC10744 were found to group under cluster IV and cluster III respectively. Cluster I diverged on the basis of nitrate reduction and four isolates showed tolerance upto 0.5 M NaCl concentrations. Two strains in cluster I and III were found to possess methane utilizing properties. Most of the isolates in all the four clusters utilized monosaccharides, disaccharide and polyols as carbon source. When the isolates were subjected for indole-3-acetic acid (IAA) analysis in the presence of L-tryptophan, only 8 isolates exhibited IAA production. In addition, the nitrogen source in the medium was found to influence the IAA production. Addition of $(NH_4)_2SO_4$ in the medium led to a 2 to 30 fold increase in the indole synthesis. However, $KNO_3$, $NH_4NO_3$ and $NH_4Cl$ substitution did not significantly stimulate the synthesis of IAA in the growth medium. Result of gnotobiotic root elongation assay significantly increased roots and shoots lengths, and number of lateral roots, which is mediated by IAA production in the culture medium. The rice seedlings primary roots from seeds treated with methylotrophic isolates were on average 27 to 56% longer than the roots from seeds treated with the uninoculated seeds. In addition, application of different high concentrations of authentic IAA ($400g\;mL^{-1}$) to roots of rice seedlings inhibited root growth. However, the IAA concentration from 10 to $200g\;mL^{-1}$, IAA promoted root growth of rice seedlings. These results suggest that bacterial IAA plays a major role in the development of the host plant root system.

Can Peritoneal Dialysis Remove Endothelin-1 after Cardiopulmonary Bypass for Repair of Congenital Heart Disease? (체외순환을 이용한 선천성 심장수술 후에 시행한 복막투석이 내피의존성 혈관 활성 물질인 Endothelin-1을 제거할 수 있는가?)

  • Chang, Yun-Hee;Ban, Ji-Eun;Lee, Hyoung-Doo;Lee, Sun-Hee;Rhym, Byuong-Yong;Sung, Si-Chan
    • Journal of Chest Surgery
    • /
    • v.40 no.4 s.273
    • /
    • pp.247-255
    • /
    • 2007
  • Background: Lung injury that follows bypass has been well described. It is manifested as reduced oxygenation and lung compliance and, most importantly, increased pulmonary vascular resistance reactivity; this is a known cause of morbidity and mortality after repair of congenital heart disease. Injury to the pulmonary vascular endothelium, and its associated alterations of endothelin-1, is considered to be a major factor of bypass-induced lung injury. Removing endothelin-1 after bypass may attenuate this response. This study measured the concentration of serum and peritoneal effluent endothelin-1 after performing bypass to determine if endothelin-1 can be removed via peritoneal dialysis. Material and Method: From March 2005 to March 2006, 18 patients were enrolled in this study Peritoneal catheters were placed at the end of surgery. Serum samples were obtained before and after bypass, and peritoneal effluents were obtained after bypass. Endothelin-1 was measured by enzyme linked immunosorbent assay (ELISA). Result: In the patients with a severe increase of the pulmonary artery pressure or flow, the mean preoperative plasma endothelin-1 concentration was significantly higher than that in the patients who were without an increase of their pulmonary artery pressure or flow (4.2 vs 1.8 pg/mL, respectively, p<0.001). The mean concentration of plasma endothelin-1 increased from a preoperative value of $3.61{\pm}2.17\;to\;5.33{\pm}3.72 pg/ml$ immediately after bypass. After peritoneal dialysis, the mean plasma endothelin-1 concentration started to decrease. Its concentration at 18 hours after bypass was significantly lower than the value obtained immediately after bypass (p=0.036). Conclusion: Our data showed that the plasma endothelin-1 concentration became persistently decreased after starting peritoneal dialysis, and this suggests that peritoneal dialysis can remove the circulating plasma endothelin-1.