• Title/Summary/Keyword: 이중 산란형

Search Result 21, Processing Time 0.018 seconds

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4 (Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가)

  • Park, Jin Hyung;Seo, Hee;Kim, Seoung Hoon;Kim, Young Soo;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.191-196
    • /
    • 2012
  • A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

Performance Evaluation of Component Detectors of Double-scattering Compton Camera (이중 산란형 컴프턴 카메라 구성 검출기 성능 평가)

  • Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.2
    • /
    • pp.69-76
    • /
    • 2010
  • Prototype double-scattering Compton camera, which consists of three gamma-ray detectors, that is, two double-sided silicon strip detectors (DSSDs) as scatterer detectors and a NaI(Tl) scintillation detector as an absorber detector, could provide high imaging resolution with a compact system. In the present study, the energy resolution and the timing resolution of component detectors were measured, and the parameters affecting the energy resolution of the DSSD were examined in terms of equivalent noise charge (ENC). The energy resolutions of the DSSD-1 and DSSD-2 were, in average, $25.2keV{\pm}0.8keV$ FWHM and $31.8keV{\pm}4.6keV$ FWHM at the 59.5 keV peak of $^{241}Am$, respectively. The timing resolutions of the DSSD and NaI(Tl) scintillation detector were 57.25 ns FWHM and 7.98 ns FWHM, respectively. In addition, the Compton image was obtained for a point-like $^{137}Cs$ gamma source with double-scattering Compton camera. From the present experiment, the imaging resolution of 8.4 mm FWHM (angular resolution of $8.1^{\circ}$ FWHM), and the imaging sensitivity of $1.5{\times}10^{-7}$ (intrinsic efficiency of $1.9{\times}10^{-6}$) were obtained.

Scattering of a Normally Incident Monochromatic Light by Optically Active Concentric Double Cylinders: I. Analytic Theory (광학활성 동축 이중 원통을 수직하게 비추는 단색 빛의 산란 : I. 해석적 이론)

  • Kim, Hyun-Woo;Kim, Jin-Seung
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.366-374
    • /
    • 2009
  • An analytic solution is obtained for the problem of monochromatic light scattering by optically active, concentric double cylinders. The validity of the obtained solution is indirectly checked by comparing it with solutions already reported for some special cases. The solution can be used in the optical analysis of rod-shaped biological cells which possibly have optically active nuclei containing helically wound chromosomes.

Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator (Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구)

  • Lee, Se-Hyung;Park, Sung-Ho;Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.51-61
    • /
    • 2009
  • A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

  • PDF

Double-Layer 3D Rear Projection Display System using Scattering Polarizer Film (후면투사 방식의 이중스크린 3D 프로젝션 디스플레이)

  • Kim, Tae-Ho;Seo, Jong-Wook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.421-425
    • /
    • 2007
  • A new 3D rear projection display system using double-layer polarization-selective screen systems, one stacked in front of the other, has been developed. The front and rear screens are made of scattering polarizer films, and they either diffuse-scatter or transmit the incident light depending on the polarization state of the light. The near and for images are projected onto the front and rear screens, respectively, using light waves with mutually orthogonal polarization states. The new display system produces clear high-resolution images, which are visible over a wide range of viewing angle. It was found that the impression of depth is pronounced and eyestrain is only comparable to that by 2D display systems.

Improvement of Polarization Maintenance Property of Scattering Polarizer Film for Double-Screen 3D Projection Display Screen Applications Via Surface Oxide Deposition (산화막 증착을 통한 이중스크린 3D 프로젝션 디스플레이 스크린용 산란형 편광필름의 편광유지도 개선)

  • Kim, Dae-Yeon;Seo, Jong-Wook
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2012
  • Keeping the polarization direction of the projection light unchanged is of crucial importance for high quality of images on a double-screen 3D projection display system. It has been found that the deposition of oxide layers on the surfaces of scattering polarizer film results in an improvement of polarization maintenance property of the film. The secondary image formed on the front screen by the light scattered from the rear screen decreases by 30% through the application of oxide layers on both surfaces of the screen. Since the oxide layer can also be used as an anti-reflection (AR) coating of the film, this method is very effective for the projection display applications.

Egg Laying Capacity of Fibricola seonlensis in Mice and Rats (마우스 및 흰쥐에 있어서 Fibricola seoulensis의 산란력)

  • Hong, Sung-Tae;Kim, Chang-Hyun;Huh, Sun;Lee, Soon-Hyung
    • Parasites, Hosts and Diseases
    • /
    • v.26 no.2
    • /
    • pp.117-120
    • /
    • 1988
  • The egg laying capacity of Fibritola seoulensis was observed in mice and rats. In mice, the mean number of eggs produced by an adult worm a day was 116 at the 1st week after infection, 123 at the 2nd week and 42 at the 3rd week. Thereafter, the capacity of about 20 eggs/worm/day was maintained up to one year period. In rats, it generally produced more eggs; 49 at 1 week, 250 at 2 weeks, 216 at 4 weeks, 327 at 6 months and 11 at one year after infection. It survived longer than a year in mice and rats.

  • PDF

Compact Tri-Band Bandpass Filter Using Dual-Mode Stepped-Impedance Resonators and Parallel Coupled-Lines (이중 모드 SIR과 평행 결합선로를 이용한 소형 3중-대역 대역통과 필터 설계)

  • Gyuje Sung;Young Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.1
    • /
    • pp.57-62
    • /
    • 2023
  • This paper proposes a tri-band bandpass filter using dual-mode stepped-impedance resonators (SIRs) with parallel coupled structures. The proposed filter adopts U-shaped SIRs with open stubs and parallel coupled lines (PCLs) that have inter-digital and comb-line shorted ends. Two U-shaped SIRs with open stubs build the first and third passband, and the central PCL resonators build the second passband. Five resonators and coupling structures are theoretically analyzed to derive the scattering parameters of the proposed filter. A novel tri-band bandpass filter is designed and fabricated using the induced scattering parameters. The measured result of the fabricated tri-band bandpass filter shows a good agreement with the simulated one.

HPAI 고병원성조류인플루엔자 - 철새로 뒤덮인 대한민국 안전지대는 없다

  • 한국오리협회
    • Monthly Duck's Village
    • /
    • s.212
    • /
    • pp.10-28
    • /
    • 2021
  • 충남 천안시 풍세면을 지나는 봉강천 야생조류에서 H5형 항원이 10월 23일 검출됨에 따라 철새 정보 알리시스템 발령기준에 의거 조류인플루엔자 발생 주의단계가 발령됐다. 주의단계 발생 한달 후인 11월 26일 전북 정읍에서 3년 만에 육용오리 농장에서 고병원성조류 인플루엔자 발생했다. 이 때부터 시작된 고병원성조류인플루엔자는 2월 15일 현재까지 100여 농장에서 발생했으며 예방적 살처분을 포함해 473농가에서 2천800여만수의 가금류가 살처분됐다. 이중 오리는 육용오리 92농가 177만1천수, 종오리 22농가 18만수가 살처분조치가 취해졌다. 닭에 비해 상대적으로 피해가 적어 보이지만 실상 오리산업의 기반이 크게 위축될 정도의 피해를 가져다 줬다. 2020년도 9월말 가축통계를 기준으로 육용오리는 20%, 종오리는 24%에 해당하는 것이다. 특히 이번 고병원성조류인플루엔자는 산란계에 특히 큰 피해를 줌으로써 계란 수급에 비상이 걸렸으며 급기야 계란을 긴급 수입하는 사태에 이르렀다. 상황이 이렇다보니 방역당국도 살처분 범위를 조정하는 등 피해 최소화를 위해 나서고 있다.

  • PDF