• Title/Summary/Keyword: 이중에너지

Search Result 998, Processing Time 0.021 seconds

Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy (이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구)

  • Myung-Jin Jung;Sung-Gil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.835-841
    • /
    • 2023
  • The aim of this study is to evaluate the diagnostic ability of dual-energy computed tomography (DECT) for Composition determination of urinary stones in phantom model. Seventeen cases with urinary stones who underwent DECT were enrolled in the study. The composition of the urinary stones was extracted from the seventeen patients were analyzed with DECT in phantom model with fresh pork. The volume scan method using Dual-energy software was used and the scanned image sets were assessed. All 17 urinary stones of the phantom model were analyzed according to the stone composition using DE stone Analysis were divided into uric acid stones (n=6, 35.29%) and non-uric acid stones (n=11, 64.71%). These urinary stones were pathologically confirmed. The mean attenuation values of uric acid stones at 135 kV, 100 kV and 80 kV was 348.87 ± 166.37 HU, 345.33 ± 151.18 HU and 337.94 ± 172.77 HU, respectively. The mean attenuation values of non-uric acid stones at 135 kV, 100 kV and 80 kV was 551.93 ± 297.09 HU, 747.04 ± 351.31 HU and 958.19 ± 424.72 HU, respectively. At 80 kV, uric acid stones and non-uric acid stones showed significant difference in the attenuation values(P<0.05). The attenuation values of DECT could differentiate the compositions of urinary stones between uric acid and non-uric acid stones at 80 kV in phantom model.

Study of Optimum Contrast Medium Quantity during Abdominal CT using Dual Energy Technique (복부 CT 검사 시 이중에너지 기법을 통한 적정한 조영제 양에 관한 연구)

  • Kang, Min;Choi, Nam-Gil;Han, Jae-Bok;Song, Jong-Nam
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.211-212
    • /
    • 2014
  • 단일에너지 복부 검사에서 사용했던 조영제 양 대비 30%, 40%, 50%, 60%, 70%로 각각 설정하여 영상을 획득한 후 대동맥, 하대정맥, 간문맥, 간실질에 관심영역을 설정하여 조영증강정도(houns -field unit; HU)를 구하여 단일에너지에서 측정된 부위와의 값을 비교 분석하였다. 그 결과 기존대비 60%로 조영제를 설정한 군에서는 대동맥 HU : $210.80{\pm}13.609$, 하대정맥 HU : $190.40{\pm}25.215$, 간문맥 $198.40{\pm}21.232$, 간실질 HU : $119.20{\pm}7.98$로 각각 측정되었으며. 단일에너지 복부 CT 검사는 대동맥 HU : $205.40{\pm}16.426$, 하대정맥 HU : $188.20{\pm}21.476$, 간문맥 HU : $195.40{\pm}22.744$, 간실질 HU : $121.00{\pm}6.595$ 이었다. 따라서 이중에너지를 이용하여 복부 조영 CT검사를 시행할 때 조영제의 양을 60%로 설정한 후 검사하는 것이 각 장기에서의 단일에너지 조영검사시와 비슷한 조영증강정도를 획득할 수 있다.

  • PDF

Stopping Power Ratio Estimation Method Based on Dual-energy Computed Tomography Denoising Images for Proton Radiotherapy Planning (양성자치료계획을 위한 이중에너지 전산화단층촬영 잡음 제거 영상 기반 저지능비 추정 방법)

  • Byungdu Jo
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.2
    • /
    • pp.207-213
    • /
    • 2023
  • Computed tomography (CT) images are used as the basis for proton Bragg peak position estimation and treatment plan simulation. During the Hounsfield Unit (HU) based proton stopping power ratio (SPR) estimation, small differences in the patient's density and elemental composition lead to uncertainty in the Bragg peak positions along the path of the proton beam. In this study, we investigated the potential of dual-energy computed tomography image-based proton SPRs prediction accuracy to reduce the uncertainty of Bragg peak position prediction. Single- and dual-energy images of an electron density phantom (CIRS Model 062M electron density phantom, CIRS Inc., Norfolk, VA, USA) were acquired using a computed tomography system (Somatom Definition AS, Siemens Health Care, Forchheim, Germany) to estimate the SPRs of the proton beam. To validate the method, it was compared to the SPRs estimated from standard data provided by the National Institute of Standards and Technology (NIST). The results show that the dual-energy image-based method has the potential to improve accuracy in predicting the SPRs of proton beams, and it is expected that further improvements in predicting the position of the proton's Bragg peak will be possible if a wider variety of substitutes with different densities and elemental compositions of the human body are used to predict the SPRs.

Energy-efficient Set-associative Cache Using Bi-mode Way-selector (에너지 효율이 높은 이중웨이선택형 연관사상캐시)

  • Lee, Sungjae;Kang, Jinku;Lee, Juho;Youn, Jiyong;Lee, Inhwan
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.1 no.1
    • /
    • pp.1-10
    • /
    • 2012
  • The way-lookup cache and the way-tracking cache are considered to be the most energy-efficient when used for level 1 and level 2 caches, respectively. This paper proposes an energy-efficient set-associative cache using the bi-mode way-selector that combines the way selecting techniques of the way-tracking cache and the way-lookup cache. The simulation results using an Alpha 21264-based system show that the bi-mode way-selecting L1 instruction cache consumes 27.57% of the energy consumed by the conventional set-associative cache and that it is as energy-efficient as the way-lookup cache when used for L1 instruction cache. The bi-mode way-selecting L1 data cache consumes 28.42% of the energy consumed by the conventional set-associative cache, which means that it is more energy-efficient than the way-lookup cache by 15.54% when used for L1 data cache. The bi-mode way-selecting L2 cache consumes 15.41% of the energy consumed by the conventional set-associative cache, which means that it is more energy-efficient than the way-tracking cache by 16.16% when used for unified L2 cache. These results show that the proposed cache can provide the best level of energy-efficiency regardless of the cache level.

Comparison of Bone Volume Measurements Using Conventional Single and Dual Energy Computed Tomography (전산화단층영상검사에서 단일에너지와 이중에너지를 이용한 뼈 부피측정의 비교)

  • Kim, Yung-kyoon;Park, Sang-Hoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.253-259
    • /
    • 2017
  • The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection(keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting(MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed $35.8{\pm}12.2$ for rib, femur ($16.1{\pm}24.1$), pelvis($13.7{\pm}18.8$), and spine($179.0{\pm}61.8$). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

Structure and Experimental Results of Automatic Insulation Greenhouse (자동단열온실의 구조 및 운전특성)

  • 이종원;이석건;이현우
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1994.05a
    • /
    • pp.88-91
    • /
    • 1994
  • 최근 국내에서도 시설원예가 급격하게 보급되고 있는 실정이다. 하지만, 시설원예가 에너지 소비형의 농경방식이라 지적되고 있는바 에너지절약형 온실의 개발이 필요할 것으로 판단되어, 본 실험실에서는 본 연구와 관련하여 비닐하우스의 벽체를 이중으로 하여 이중벽사이에 단열입자를 송풍기의 케이싱내로 직접 통하게하는 직송방식으로 충전ㆍ회수하는 실험을 실시한 바가 있으며, 그 결과 외기온의 평균이 -4.9$^{\circ}C$인 겨울철 야간에 입자를 충전한 이중비닐 하우스의 내부온도는 평균 9.8$^{\circ}C$로 단열성이 우수함을 알 수 있었다.(중략)

  • PDF

A Simulation Study on Image Quality of Virtual Monochromatic Image using Dual-energy Method (이중에너지 방법을 이용한 가상 단색 영상의 화질 시뮬레이션 연구)

  • Son, Ki-Hong;Lee, Soo-Yeul;Kim, Dae-Hong;Chung, Myung-Ae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.553-558
    • /
    • 2022
  • The purpose of this work was a simulation study to evaluate the virtual monochromatic (VM) image quality of blood vessels compared to the monochromatic image. Dual-energy images were obtained based on the linear attenuation coefficients of five materials at 50 keV and 80 keV at low- and high-energies, respectively. A weighting factor is required to synthesize the VM image, and the liver and bone were used as basis materials to obtain the weighting factor. VM images were synthesized at energies ranging from 30 keV to 100 keV. Image quality was evaluated by Contrast to noise ratio (CNR) and noise by setting calcium and contrast medium as signals and blood as background. According to the results, the energies with the maximum CNR were 50 keV and 60 keV for calcium and contrast medium, respectively. The energies showing the minimum noise were 70 keV, 70 keV, and 60 keV in calcium, iodine contrast medium, and blood, respectively. The VM image can contribute to the improvement of diagnostic performance in CT examination because it can implement an image at the optimal energy that minimize noise and maximize CNR.

A Study on the Possibility of Pancreas Detection through Extraction of Effective Atomic Number using a Simulation such as Dual-energy CT (이중에너지 CT와 같은 시뮬레이션을 이용한 유효원자번호 추출을 통한 췌장 검출 가능성 연구)

  • Son, Ki-Hong;Lee, Soo-Yeul;Chung, Myung-Ae;Kim, Dae-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.537-543
    • /
    • 2022
  • The purpose of this simulation study was to evaluate the possibility of pancreas detection through effective atomic number information using dual-energy computed tomography(CT). The effective atomic number of 10 tissue-equivalent materials were estimated through stoichiometric calibration. For stoichiometric calibration, HU values at low-energy (80 kV) and high-energy (140 kV) for 10 tissue-equivalent materials were used. Based on this method, the effective atomic number image of the tissue-equivalent material was extracted through an iterative algorithm. According to the results, the attenuation ratio in accordance with the effective atomic number was estimated to have an R2 value of 0.9999, and the effective atomic number of Pancreas, Water, Liver, Blood, Spongiosa, and Cortical bone was overall within 1% accuracy compared to the theoretical value. Conventional pancreatic cancer examination uses a contrast medium, so there is a possibility of potential side effects of the contrast medium. In order to solve this problem, it is thought that it will be possible to contribute to an accurate and safe examination by extracting the effective atomic number using dual-energy CT without contrast enhancement. Based on this study, future research will be conducted on the detection of pancreatic cancer using the HU value of pancreatic cancer based on clinical images.

Electrical and structural properties of back reflecting layer with AZO-Ag bilayer structure on a stainless steel substrate for thin film Si based solar cell applications (Flexible 박막 Si태양전지 응용을 위한 SUS기판 위의 AZO-Ag 이중구조 배면전극의 전기/구조적 특성)

  • Hong, ChangWoo;Choi, YoungSung;Park, Jaecheol;Lee, JongHo;Kim, TaeWon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.125.1-125.1
    • /
    • 2011
  • 빛 에너지를 전기에너지로 변환하는 발전소자인 태양전지는 청정 재생 에너지원으로 최근 Si 박막 태양전지의 고 효율화를 위해 여러 기술적인 면에서 개발되어지고 있다. 현재 박막형 태양전지는 실리콘계가 주류를 이루고 있으며, 유리 혹은 유연성기판(금속 or 고분자)에 비정질 실리콘 박막을 형성시킨 태양전지와 실리콘웨이퍼의 양면에 태양전지를 형성함으로써 효율을 극대화시킨 이종접합태양전지 등이 연구되고 있다. 특히 flexible 태양전지는 hard 기판에 비해 비교적 저가인 플라스틱 필름과 금속 foil을 기판으로 이용함으로서 저가화가 용이하며, 가볍고 유연성을 갖추고 있어 휴대와 시공에 있어 매우 우수한 장점을 가지고 있다. 본 연구에서는 flexible 기판(stainless steel)을 이용하여 태양전지 내 반사막 층이 미치는 영향을 알아보기 위하여 AZO/Ag 이중구조 박막의 특성을 연구하였다. RF magnetron sputtering system을 이용하였으며, 상온에서 Ag/AZO 이중구조 박막을 제조하였다. stainless steel 기판 위에 Ag층을 25nm 두께로 증착하였으며 연속공정으로 AZO 박막을 100~500nm의 두께경사를 가지도록 성장시켰다. 이 때의 AZO/Ag 이중구조 박막의 표면 morphology는 AFM 분석결과 7nm~3nm의 값을 나타내었으며, AZO 박막의 두께가 증가할수록 rms 값이 감소하는 경향을 보여주었다. 본 발표에서는 flexible 기판 상에 성장된 AZO/Ag 이중구조 박막의 전기적, 광학적 특성 등에 관하여 추가적으로 토론한 후 태양전지 효율 중 흡수층 내 반사막 층이 미치는 역할을 알아보겠다.

  • PDF

Growth and characterization of Zn layered-double hydroxide (LDH) based two-dimensional nanostructure

  • Nam, Gwang-Hui;Baek, Seong-Ho;Im, Ji-Su;Lee, Sang-Seok;Park, Il-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.371.1-371.1
    • /
    • 2016
  • 다양한 물질계의 2차원 나노구조는 그래핀과 함께 그 고유특성으로 최근 광전소자, 전자소자, 센서, 에너지 생성 및 저장과 수소에너지 생성 등의 응용으로 매우 많은 관심을 받고 있다. 특히 층상이중수산화물 (layered-double hydroxide; LDH) 2차원 나노구조는 생성의 용이성과 층상 내 금속 이온의 교환을 통한 특성의 자유로운 제어가 가능하므로 많은 관심을 받고 있다. 층상이중수산화물 화합물은 [Zn(1-x) MIII(x)(OH)2][$An-x/n{\cdot}mH2O$] (MIII = Al, Cr, Ga; An- = CO32-, Cl-, NO3-, CH3COO-) 구조로써, Brucite-type 구조 내에서 3가 양이온의 상태에 따라서 다양한 특성을 제어할 수 있는 장점이 있다. 이러한 장점으로 인해 층상이중수산화물 화합물은 촉매나, 에너지 저장, 음이온 교환 및 흡착, 화학적 촉매, 바이오 소자 등에 응용이 연구되고 있으며, 다양한 금속 산화물을 제조하기 위한 중간자 precursor로써도 연구되고 있다. 하지만, 이러한 대부분의 연구들을 통한 결과물들이 분말 및 수용액 상태로 남게 되며, 이러한 화합물의 특성을 제어하기 어려운 문제점이 있다. 더욱이 이러한 나노구조물들을 다양한 소자로 응용하기 위해서는 상용의 실리콘이나 glass 등의 기판형태의 물질상에 성장시킬 수 있어야 하며, 그러한 기판 위에서의 형상 및 특성 제어가 용이해야 한다. 따라서 본 연구에서는 실리콘 기판을 적용한 Zn기반의 층상이중 수산화물 화합물을 성장하고, 하부물질의 조성제어를 통한 층상이중수산화물 화합물의 형상제어가 가능한 기술에 관한 연구를 보고하고자 한다. 이를 위한 하부물질의 조성은 Zn와 Al을 통해 이루어지며, 기형성된 Al2O3박막을 핵형성층으로 활용한다. 이러한 방법으로 형성된 층상이중수산화물 화합물에 대해 이차전자주사현미경, 투과전자현미경 및 X-ray회절기법을 통해 구조분석을 하고, Raman 및 광발광스펙트럼 분석을 통해 광학적 분석을 시행함으로써, 층상이중수산화물이 기판상에서 형성되는 메커니즘에 관한 규명을 시행하였다. 이러한 분석연구를 통해 핵형성층의 에칭 따라 실리콘 기판상에서 성장하는 층상이 중수산화물 화합물의 형상 및 조성이 제어되는 메커니즘을 구명하였다.

  • PDF