• Title/Summary/Keyword: 이중선원

Search Result 23, Processing Time 0.028 seconds

Preliminary Study (1) for Development of Computed Radiography (CR) Image Analysis according to X-ray Non-destructive Test by Wood Species (Computed Radiograhpy (CR)를 통한 목재 수종별 X선 투과 이미지 해석을 위한 기초연구 (1))

  • Song, Jung Il;Kim, Han Seul
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.220-231
    • /
    • 2021
  • The use of digital copies of film-based analog images and the introduction of digital radiographic imaging systems using image plates gradually replace the non-destructive radiationirradiation method of Cultural Heritage. The quality of images obtained from this technique is affected by conditions such as tube voltage, tube current, and exposure time, type of image acquisition medium, distance of the artifacts from the image acquisition medium, and thickness of artifacts. In this study, we evaluated the grayscale image obtained using GE's Computed Radiograhpy (CR) imaging system, the transmission characteristics of the X-ray source for each tree type (pine, chestnut, sawtooth oak, ginkgo) used in wooden Cultural Heritage, and the signal-to-noise ratio (SNR) and contrast. The GE's CR imaging were analyzed using the Duplex wire image quality indicator, line-pair gauges.

Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT (간의 단일선원 Twin Beam과 이중선원 이중에너지 전산화단층촬영의 비조영증강 영상과 가상 비조영증강 영상의 비교 연구)

  • Jeong Sub Lee;Guk Myung Choi;Bong Soo Kim;Su Yeon Ko;Kyung Ryeol Lee;Jeong Jae Kim;Doo Ri Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.170-184
    • /
    • 2023
  • Purpose To assess the magnitude of differences between attenuation values of the true non-contrast image (TNC) and virtual non-contrast image (VNC) derived from twin-beam dual-energy CT (tbDECT) and dual-source DECT (dsDECT). Materials and Methods This retrospective study included 62 patients who underwent liver dynamic DECT with tbDECT (n = 32) or dsDECT (n = 30). Arterial VNC (AVNC), portal VNC (PVNC), and delayed VNC (DVNC) were reconstructed using multiphasic DECT. Attenuation values of multiple intra-abdominal organs (n = 11) on TNCs were subsequently compared to those on multiphasic VNCs. Further, we investigated the percentage of cases with an absolute difference between TNC and VNC of ≤ 10 Hounsfield units (HU). Results For the mean attenuation values of TNC and VNC, 33 items for each DECT were compared according to the multiphasic VNCs and organs. More than half of the comparison items for each DECT showed significant differences (tbDECT 17/33; dsDECT 19/33; Bonferroni correction p < 0.0167). The percentage of cases with an absolute difference ≤ 10 HU was 56.7%, 69.2%, and 78.6% in AVNC, PVNC, and DVNC in tbDECT, respectively, and 70.5%, 78%, and 78% in dsDECT, respectively. Conclusion VNCs derived from the two DECTs were insufficient to replace TNCs because of the considerable difference in attenuation values.

Preliminary Study on Performance Evaluation of a Stacking-structure Compton Camera by Using Compton Imaging Simulator (Compton Imaging Simulator를 이용한 다층 구조 컴프턴 카메라 성능평가 예비 연구)

  • Lee, Se-Hyung;Park, Sung-Ho;Seo, Hee;Park, Jin-Hyung;Kim, Chan-Hyeong;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.51-61
    • /
    • 2009
  • A Compton camera, which is based on the geometrical interpretation of Compton scattering, is a very promising gamma-ray imaging device considering its several advantages over the conventional gamma-ray imaging devices: high imaging sensitivity, 3-D imaging capability from a fixed position, multi-tracing functionality, and almost no limitation in photon energy. In the present study, a Monte Carlo-based, user-friendly Compton imaging simulator was developed in the form of a graphical user interface (GUI) based on Geant4 and $MATLAB^{TM}$. The simulator was tested against the experimental result of the double-scattering Compton camera, which is under development at Hanyang University in Korea. The imaging resolution of the simulated Compton image well agreed with that of the measured image. The imaging sensitivity of the measured data was 2~3 times higher than that of the simulated data, which is due to the fact that the measured data contains the random coincidence events. The performance of a stacking-structure type Compton camera was evaluated by using the simulator. The result shows that the Compton camera shows its highest performance when it uses 4 layers of scatterer detectors.

  • PDF

Study on the Free Volume in Polymer by Positron Annihilation Lifetime Spectroscopy (PALS) (양전자소멸 수명시간 측정을 통한 폴리머소재의 자유부피에 관한 연구)

  • Kim, Yongmin;Shin, Jungki;Kwon, Junhyun
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.489-493
    • /
    • 2012
  • Positron Annihilation Lifetime Spectroscopy is a non-destructive technique to study voids and defects in solids by the measurement of gammas from electron-positron annihilation. In this study, we measured the lifetime of CR, EPDM, NBR, all of which are widely used polymer in various fields. A conventional fast-fast coincidence system in KAERI(Korea Atomic Energy Research Institute) has been used to measure the lifetime spectra, Three lifetime components were analyzed from each lifetime spectra. According to Tao-Eldrup model equation, the size and fraction of free-volume were calculated. Mean radius and free volume fraction of CR, EPDM NBR are $0.1217nm^3$(1.9103%), $0.14780nm^3$(5.3147%), $0.1216nm^3$(2.6381%), respectively. Through these measurements, we identified the feasibility of the PAL system for polymer analysis.

Development of Tomographic Scan Method for Industrial Plants (산업공정반응기의 감마선 전산 단층촬영기술 개발)

  • Kim, Jong-Bum;Jung, Sung-Hee;Moon, Jin-Ho;Kwon, Taek-Yong;Cho, Gyu-Seong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.20-30
    • /
    • 2010
  • In this paper, a new tomographic scan method with fixed installed detectors and rotating source from gamma projector was presented to diagnose the industrial plants which were impossible to be examined by conventional tomographic systems. Weight matrix calculation method which was suitable for volumetric detector and statistical iterative reconstruction method were applied for reconstructing the simulation and experimental data. Monte Carlo simulations had been performed for two kinds of phantoms. Lab scale experiment with a same condition as one of phantoms, had been carried out. Simulation results showed that reconstruction from photopeak counting measurement gave the better results than from the gross counting measurement although photopeak counting measurement had large statistical errors. Experimental data showed the similar result as Monte Carlo simulation. Those results appeared to be promising for industrial tomographic applications, especially for petrochemical industries.

Protocol Optimization of Coronary CT Angiography (심혈관 CT 조영술의 프로토콜 최적화)

  • Lee, Hae-Kag;Yoo, Heung-Joon;Lee, Sun-Yeob;Goo, Eun-Hoe;Seok, Jong-Min;Han, Man-Seok;Lee, Kwang-Sung;Cho, Jae-Hwan;Kim, Bo-Hui;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.51-58
    • /
    • 2011
  • This research compared and analyzed the heart rate of the patient in which the LVEF value is 40% less than and normal patient. When as for LVEF 40% or less becomes to each heart rate and LVEF in a relation, we can know that the time to reach 100HU hangs long. Therefore, in patients, that is 40% less than, when setting up the Premonitoring delay, we could know to could give 5 primary solid phrases. It is seen that subsequently an addition injected 40cc as to Saline, to all patients by 4cc/sec speeds after injecting the capacity of Scan time ${\times}$ 4cc + 30cc with 4cc/sec speeds. And HR excludes 80 or greater in 40% less than, the contrast agent shows the large-scale difference. In addition, in 40% less than, it could predict that the time difference was big and the contrast agent was already out in the Left ventricle Wash- when the contrast agent reached 100HU and Scan was started There is a wide difference between under 40% LVEF and normal. when starting scan from low LVEF patients. So, Injection contrast media protocol Should be determined to CCTA. And then In case of low LVEF is recommended to more low Pitch than routine Pitch because we should reduce scan failed in accordance with low LVEF.

Lifejcket-Integrated Antenna for Search and Rescue System (탐색 및 구조 시스템용 구명조끼 내장형 안테나)

  • Lim, Ji-Hun;Yang, Gyu-Sik;Jung, Sung-Hun;Park, Dong-Kook
    • Journal of Navigation and Port Research
    • /
    • v.38 no.4
    • /
    • pp.367-371
    • /
    • 2014
  • When the crew or passengers fall into the water due to marine accident of vessel, it is very important to rescue them quickly. In the case of marine accidents, most people in distress have been wearing a lifejacket, so if the GPS and Cospas-Sarsat communication module will be integrated within the lifejacket, it is easy to rescue them. In this paper, development of the dual band lifejacket-integrated antenna for GPS and Cospas-Sarsat communication is discussed. The antenna with the FR-4 substrate of 0.2mm thickness for flexibility was designed that it can be fitted close to the shoulder of the life jacket and operate at 1.575GHz and 406MHz. The GPS communication antenna was implemented with a ring-slot antenna having a circular polarized characteristic and a meander type linear polarized antenna is used as Cospas-Sarsat communication. The two antennas are fed by a single microstrip line and an open stub is used to minimize the mutual interference between the two antennas. The performance of the fabricated antenna attached to the life vest is confirmed by the measurement of the return loss at GPS and Cospas-Sarsat frequency bands.

A High Viscosity of Curdlan at Alkaline pH Increases Segregational Resistance of Concrete (염기성 pH에서의 고점도 커들란에 의한 콘크리트의 재료분리 억제 효과 증진)

  • 이인영;김선원;이중헌;김미경;조인성;박영훈
    • KSBB Journal
    • /
    • v.14 no.1
    • /
    • pp.114-118
    • /
    • 1999
  • In order to use a polysaccharide, curdlan, as a concrete admixture, we first developed a pilot-scale fermentation process for the mass production of curdlan. We also examined the rheological properties of curdlan, and tested how well the curdlan obtained in this work increased the segregational resistance of the cement slurry. Fermentation was performed in a 300-liter fermenter equipped with 3 disk-turbine impellers. Since curdlan production is stimulated under nitrogen-limiting conditions, the culture pH was shifted from the optimal pH for cell growth (pH 7.0) to the optimal pH for curdlan production (pH 5.5) at the onset of ammonium exhaustion. We obtained a curdlan production of 65 g/L in 120 hr batch cultivation of Agrobacterium species. The insoluble curdlan at the final stage of fermentation was readily harvested by centrifugation together with the cells. The freeze-dried sample contained 78% (w/w) of curdlan. The solubility and viscosity of the curdlan increased with the increase of the solution pH, which enhances the viscosity of concrete since the pH of concrete is extremely high (pH 13.0). Test results of the curdlan as a concrete admixture with cement slurry demonstrated that it prohibits the leakage of water. In conclusion, this work certifies and enlarges curdlan's industrial potential as a concrete admixture.

  • PDF

Development of a Spectrum Analysis Software for Multipurpose Gamma-ray Detectors (감마선 검출기를 위한 스펙트럼 분석 소프트웨어 개발)

  • Lee, Jong-Myung;Kim, Young-Kwon;Park, Kil-Soon;Kim, Jung-Min;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2010
  • We developed an analysis software that automatically detects incoming isotopes for multi-purpose gamma-ray detectors. The software is divided into three major parts; Network Interface Module (NIM), Spectrum Analysis Module (SAM), and Graphic User Interface Module (GUIM). The main part is SAM that extracts peak information of energy spectrum from the collected data through network and identifies the isotopes by comparing the peaks with pre-calibrated libraries. The proposed peak detection algorithm was utilized to construct libraries of standard isotopes with two peaks and to identify the unknown isotope with the constructed libraries. We tested the software by using GammaPro1410 detector developed by NuCare Medical Systems. The results showed that NIM performed 200K counts per seconds and the most isotopes tested were correctly recognized within 1% error range when only a single unknown isotope was used for detection test. The software is expected to be used for radiation monitoring in various applications such as hospitals, power plants, and research facilities etc.

Analysis of Grounding Accidents in Small Fishing Vessels and Suggestions to Reduce Them (소형어선의 좌초사고 분석과 사고 저감을 위한 제언)

  • Chong, Dae-Yul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.4
    • /
    • pp.533-541
    • /
    • 2022
  • An analysis of marine accidents that occurred in the last five years, revealed that 77.0 % of all grounding accidents and 66.1% of all marine casualties involved small vessels, which was a very high level relatively. The Mokpo Regional Maritime Safety Tribunal (Mokpo-KMST) inquired on 72 cases of marine accidents in 2021, of which 10 cases were grounding accidents. Furthermore, eight cases of grounding accidents occurred in small fishing vessels. This study analyzed eight cases of grounding accidents on small fishing vessels that inquired in the jurisdictional area of Mokpo-KMST in 2021. I found out that this grounding occurred in clear weather with good visibility (2-4 miles) and good sea conditions with a wave height of less than 1 meter. Furthermore, I found that the main causes of grounding were drowsy navigation due to fatigue, neglect of vigilance, neglect of checking ship's position, overconfidence in GPS plotter, and lack of understanding of chart symbols and tidal differences. To reduce grounding accidents of small fishing vessels, I suggested the following measures. First, crew members who have completed the able seafarer training course on bridge watchkeeping should assist to the master. Second, alarm systems to prevent drowsiness should be installed in the bridge. Third, the regulation should be prepared for the performance standards and updating GPS plotter. Finally, the skipper of small vessels should be trained periodically to be familiar with chart symbols and basic terrestrial navigation.