• Title/Summary/Keyword: 이중동심관

Search Result 21, Processing Time 0.021 seconds

A Study on the Turbulent Flow in Concentric Annuli with Both Rough Walls (양벽면에 거칠기가 있는 이중동심관내의 난류유동에 관한 연구)

  • 안수환;정양범
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.17-25
    • /
    • 1994
  • Fully developed turbulent flow through three concentric annuli with both the rough inner and outer walls was experimentally investigated for a Reynolds number range Re = 15, 000 - 85, 000. Measurements were carried out for the pressure drop, the positions of zero shear stress and maximum velocity, and the velocity distributions in annuli of radius ratios, ${\alpha}$=0.26, 0.4 and 0.56, respectively. The experimental results showed that the positions of zero shear stress and maximum velocity were only weakly dependent on the Reynolds number.

  • PDF

Fullly Developed Turbulent Flow and Heat Transfer in Concentric Annuli with Square - Ribbed Roughness (사각형 거칠기가 있는 동심이중관 내의 완전히 발달된 난류유동과 열전달)

  • 안수환;오세경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.41-50
    • /
    • 1994
  • 동심 이중관내에서 외관내벽의 사각돌출형 조도요소에 의한 비대칭 난류유동과 열전달 특성을, 열전달과 마찰계수에 미치는 조도의 합성효과를 조사하기 위해, 연구하였다. 이론해석에서는 수정 플란틀 혼합길이(mixing length)이론의 난류모델을 속도분포와 마찰계수를 구하는데 사용하였다. 최대 속도지점에서 안쪽과 바깥쪽의 두 속도 형상들은 힘의 평형에 의해 일치시켰다. 그리고나서, 온도분포와 열전달 계수를 계산하였다. 속도형상과 마찰계수들의 해석결과는 반경비 (${\alpha}$)= 0.13, 0.26, 0.4, 그리고 0.56 경우의 실험과 매우 잘 일치하였다. 마찰계수와 Nusselt number에 미치는 반경비, 조도비, 그리고 조도에 대한 피치비 등과 같은 여러 변수들의 효과들을 조사하였다. 본 연구는 일정 조도 요소들이 전체적 효율 측면에서 볼 때 열전달을 우리하게 향상시킨다는 것을 증명하였다.

  • PDF

Turbulent flow in annuli depending on the position of roughness (거칠기 위치에 따른 이중관 내의 난류유동)

  • An, Su-Hwan;Kim, Gyeong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.7
    • /
    • pp.891-899
    • /
    • 1997
  • This paper presents the results of a detailed experimental examination of fully developed asymmetric flows between annular tubes with square-ribbed surface roughness. The main emphasis of the research has been on establishing the turbulence structure, particularly in the central region of the channel where the two dissimilar wall flows interact. Measurements have included profiles of time mean velocities, turbulence intensities, turbulent shear stresses, triple velocity correlations, skewness, and flatness. The region of greatest interaction is characterized by strong diffusional transport of turbulent shear stress and kinetic energy from rough toward the smooth wall region, giving rise to an appreciable separation between the planes of zero shear stresses depending on positions of roughness on the walls.

NUMERICAL STUDY ON NATURAL CONVECTION HEAT TRANSFER IN A NANOFLUID FILLED CONCENTRIC ANNULUS (동심이중관내 나노유체의 자연대류열전달에 관한 수치적 연구)

  • Choi, H.K.;Park, J.H.;Yoo, G.J.
    • Journal of computational fluids engineering
    • /
    • v.21 no.3
    • /
    • pp.1-7
    • /
    • 2016
  • In the present study, the homogeneous model is used to simulate the natural convection heat transfer of the CuO-water nanofluid in a concentric annular enclosure. Simulations have been carried while the Rayleigh number ranges from $10^3$ to $10^6$, solid volume fraction ranges from 0.01 to 0.04 and the radius ratio varies between 0.1 and 0.7. Results are presented in the form of streamlines, isotherm patterns and averaged Nusselt numbers for different values of solid volume fraction, radius ratio of the annulus and Rayleigh numbers. The results show that by decreasing the radius ratio and/or increasing the Rayleigh number, the averaged Nusselt number increases. Also the heat transfer rate increases as increased solid volume fractions.

An experimental study on the effect of parameters for onset of nucleate boiling in concentric annuli flows (이중 동심관 유동에서 핵비등 시발점의 영향인자에 대한 실험적 연구)

  • Song, J.H.;Kim, K.C.;Lee, S.H.;Park, J.H.;Suk, H.C.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.373-378
    • /
    • 2000
  • An experimental investigation on the incipience of nucleate boiling in forced flow of water is performed as a verification and extension of previous analysis. The effects of the subcooling, Reynolds number and surface curvature on the onset of nucleate boiling(ONB) in a concentric annulus flow channel with smooth inner heating surface is investigated experimentaly. Through flow visualization, the boiling phenomenon was observed directly and the experimental results were examined to find ONB heat flux. The results show that the variation of heat flux at ONB is increased linearly as the Reynolds number and subcooling are increased. The effect of surface curvature is very great specially for a small radius when radius of the inner heating tube is increased, the heat flux at ONB is almost inversely increased for the range of this investigation. It is found that the effect of convex surface curvature on ONB heat flux is very significant for a small radius.

  • PDF

Turbulent Flow and heat Transfer in the Annular Passage with Repeated-Ribbed Roughness on Both Walls (양측벽면에 반복돌출형 거칠기가 있는 이중관통로내의 난류유동과 열전달)

  • 안수환;김덕현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-12
    • /
    • 1996
  • The fully developed tubulent momentum and heat transfer induced by the square- ribbed roughness elements on both the inner and outer wall surfaces in the concentric annuli are studied analytically based on a modified turbulence model. Heat transfer coefficients for two conditions, i.e, a) inner wall heated as constant heat flux and outer wall insulated b) inner wall insulated and outer wall heated as constant heat flux, are investigated. The analytical results of the fluid flow are verified by experiment. The experiment is done with a pitot tube and a X-type hot wire anemometer to measure the time mean velocity profiles, zero shear stress positions, maximum velocity profiles and friction factors, and etc. The resulting momentum and heat transfer are discussed in terms of various parameters, such as the radius ratio, the relative roughness, the roughness density, Nusselt number and Prandtl number.

  • PDF

Turbulent Flow and Heat Transfer in an Annular Passage with Repeated-Ribbed Roughness on Both Walls (양측벽면에 반복돌출형 거칠기가 있는 이중관통로내의 난류운동과 열전달)

  • 안수환;이윤표
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.5
    • /
    • pp.26-36
    • /
    • 1996
  • The fully developed turbulent momentum and heat transfer induced by the square-ribbed roughness elements on both the inner and outer wall surfaces in concentric annuli are studied analytically based on a modified turbulence model. The analytical results of the fuid flow are verified by experiment. The experiment is done with a pitot tube and a X-type hot wire anemometer to measure the time mean velocity profiles, zero shear stress positions, maximum velocity positions and friction factors, and etc. shown in Fig.1. The resulting momentum and heat transfer are discussed in terms of various parameters, such as the radius ratio, the relative roughness, the roughness density, Reynolds number, Nusselt bumber and Prand시 number. The study demonstrates that certain artificial roughness elements may be used to enhance heat transfer rates with advantage from the overall efficiency point of view by investigating turbulent flows and heat transfer in Fig.1.

  • PDF

The Inprovement of the Heat Exchanger Performance by Shape Modification(I)-Experimental Analysis of the Heat Transfer Enhancement by Attached Wires in a Double Pipe Heat Exchanger- (형상변화 에 의한 열교환기 의 열전달 성능 향상 (I) -이중 동심원관내에 와이어 부착시의 열전달 촉진에 대한 실험적 해석-)

  • 노승탁;이택식;강신형;김진오
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.71-80
    • /
    • 1985
  • The various sizes of wires are attached to the outside of the inner tube in a double pipe heat exchanger to enhance the thermal performance. The diameters of the wires range from 0.5mm to 1.6mm while the pitches are chosen between 5mm and 50mm. Experiments have been performed with the range of Reynolds numbers from 15000 to 30000 in annular space where air flows. The friction factors are increased by 1.5 to 4.5 times depending on the sizes and the pitches of the wires. However, the Nusselt numbers are increased by the factors of 1.8 to 2.8 within this experimental range. It is suggested that there should be an optimum configuration rendered when the weighting values of the heat transfer promotion and the pumping power are given.

Investigation of FIV Characteristics on a Coaxial Double-tube Structure (동심축 이중관 구조에서 유동기인진동 특성 고찰)

  • Song, Kee-Nam;Kim, Yong-Wan;Park, Sang-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.10
    • /
    • pp.1108-1118
    • /
    • 2009
  • A Very High Temperature Gas Cooled Reactor (VHTR) has been selected as a high energy heat source of the order of $950^{\circ}C$ for nuclear hydrogen generation, which can produce hydrogen from water or natural gas. A primary hot gas duct (HGD) as a coaxial double-tube type cross vessel is a key component connecting a reactor pressure vessel and an intermediate heat exchanger in the VHTR. In this study, a structural sizing methodology for the primary HGD of the VHTR is suggested in order to modulate a flow-induced vibration (FIV). And as an example, a structural sizing of the horizontal HGD with a coaxial double-tube structure was carried out using the suggested method. These activities include a decision of the geometric dimensions, a selection of the material, and an evaluation of the strength of the coaxial double-tube type cross vessel components. Also in order to compare the FIV characteristics of the proposed design cases, a fluid-structure interaction (FSI) analysis was carried out using the ADINA code.

An analysis of acoustic pressure in the center of double pipe inside of a cylindrical vibrator (원통형 진동자 내부의 이중관 중심에서의 음압해석)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.165-171
    • /
    • 2017
  • The effect of the concentric solid tube inserted inside the vibrator on the sound field distribution was analyzed for the sound waves focused on the center axis in the fluid - filled cylindrical piezoelectric transducer. The sound waves radiated from the inside of the cylindrical piezoelectric vibrator are transmitted through the fluid medium and are reflected or transmitted on the wall surface of the solid tube, and are focused on the central axis. At this time, the sound field distribution centered on the acoustic tube varies depending on the acoustic impedance and the thickness of the solid tube. In order to theoretically analyze this, the transfer matrix for each medium is derived, and the sound pressure level at the center axis is theoretically analyzed. For the acrylic tube with various thicknesses, the changing trend in the sound pressure level measured on the central axis agrees well with the result of the theoretical analysis, and it confirmed that the sound pressure formed at the center changes very sensitively with the thickness of the solid tube.