• Title/Summary/Keyword: 이종부품

Search Result 177, Processing Time 0.025 seconds

Experimental Study on Auto-Transmission Fluid Heat Exchanger for Improving Vehicle Fuel Efficiency (차량 연비개선을 위한 자동변속기유 열교환기에 대한 실험적 연구)

  • Jang, Chung-Man;Lee, Yong-Kyu;Kang, Byeong-Dong;Yoo, Jai-Suk;Lee, Jong-Hwa;Kim, Hyun-Jung;Kim, Dong-Kwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.947-954
    • /
    • 2011
  • Drive-train friction loss in a vehicle may account for 4% of its total fuel consumption loss. An ATF W/C (auto-transmission fluid warmer/cooler) plate-fin heat exchanger is a type of heat exchanger that uses metal plates to transfer heat between the auto-transmission fluid and coolant. The use of an ATF W/C heat exchanger can result in a fuel economy improvement of about 1% in vehicles. An experimental setup for testing the thermal performance of an ATF W/C plate-fin heat exchanger is developed. In this study, the influence of the ATF and coolant, flow rates, and temperature on the efficiency of an ATF W/C heat exchanger are investigated experimentally. From the experimental data, a simple correlation for predicting the efficiency of an ATF W/C heat exchanger is proposed. On the basis of this correlation, the fuel economy of a vehicle with and without an ATF W/C heat exchanger is compared by using Simulink. Finally, it is shown that the fuel economy is improved by 0.992% when an ATF W/C heat exchanger is installed in the vehicle.

A Design Solution for a Railway Switch Monitoring System (분기기 진단 시스템 설계에 관한 연구)

  • Choo, Eun-Sang;Kim, Min-Seong;Yoo, Heung-Yeol;Mo, Choong-Seon;Son, Eui-Sik;Park, Seongguen;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.5
    • /
    • pp.439-446
    • /
    • 2015
  • The turnout system, which determines the direction of the train, is not only a key system but also a vulnerable system. Failure of this system may lead to a delay of the train or even casualties. In this light, it is necessary to precisely the conditions of the turnout system. Currently, ROADMASTER of Germany is used as a diagnostic system in Korea. However, a new diagnostic system should be developed for optimized operation of the turnout system with maintenance that is suitable for the Korean railway environment. In this paper, a Fault Tree Analysis for the representative faults of the turnout system is conducted and physical quantities, which can be the cause of the fault, are classified according to the component and function. Also, the measuring factors for the monitoring are derived and a decision making theory is suggested. On the basis of the results, we propose a new turnout diagnostic system that can provide more driverse and precise information than the conventional system.

Development of Novel Joint Device for a Disposal Canister in Deep Borehole Disposal (고준위폐기물 심부시추공 처분을 위한 처분용기 접속장치의 개발)

  • LEE, Minsoo;LEE, Jongyoul;JI, Sung-Hoon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.2
    • /
    • pp.261-270
    • /
    • 2018
  • In this study, to replace the 'J-slot joint', a joint device between a disposal canister and an emplacement jig in Deep Borehole Disposal process, a novel joint device was designed and tested. The novel joint device was composed of a wedge on top of a disposal canister and a hook box at the end of a winch system. The designed joint device had merits in that it can recombine an emplaced canister freely without the replacement of the joint component. Moreover, it can be applied to various emplacement jigs such as drill pipes, wire-lines, and coiled tubing. To demonstrate the designed joint device, the joint device (${\Phi}110mm$, H 148 mm), a twin canister string (${\Phi}140mm$, H 1,105 mm), and a water tube (${\Phi}150mm$, H 1,500 mm) as a borehole model were manufactured at 1/3 scale. As deployment muds, Na-type bentonite (MX-80) and Ca-type (GJ II) bentonite muds were prepared at solid contents of 7wt% and 28wt%, respectively. The manufactured joint device showed good performance in pure water and viscous muds, with an operation speed of $10m{\cdot}min^{-1}$. It was concluded that the newly developed joint device can be used for the emplacement and retrieval of a deep disposal canister, below 3~5 km, in the future.

Evaluation on the Additional CO2 by Mobile Air Conditioning Systems of Korean Light-duty Vehicles (국내 소형자동차의 에어컨 가동에 따른 CO2 배출량 평가)

  • Park, Junhong;Lee, Jongtae;Kim, Sunmoon;Kim, Jeongsoo;Kang, Gunwoo
    • Journal of Climate Change Research
    • /
    • v.3 no.4
    • /
    • pp.259-270
    • /
    • 2012
  • Mobile air conditioning(MAC) systems of light-duty vehicles consume the most energy among auxiliary parts. Vehicle $CO_2$ reduction policies in Korea, US EPA and EU include the strategies to reduce additional $CO_2$ by MAC operation with providing incentive for the high-efficient MAC technologies. It is under development how to estimate MAC $CO_2$ and to differentiate advanced or high-efficient MAC system in US EPA and EU. The additional energy by MAC operation would beaffected by not only driving patterns but also environmental conditions such as temperature and humidity. In this study, we estimated MAC $CO_2$ of Korean light-duty vehicles with various driving cycles and environmental conditions. Test results were corrected to reference conditions for varied temperature and humidity during tests to get the comparable data for test vehicles. The test results showed that high-efficient MAC technologies have potential to reduce MAC $CO_2$ approximately by 50%. Considering the rate of MAC $CO_2$ to vehicle $CO_2$, it is expected that the introduction of high-efficient MAC technologies would considerably reduce vehicle $CO_2$ emission in MAC operation.

Survey of nitroso-compounds level derived from additives in metal-working fluids (유통 수용성 금속가공유 중 니트로 화합물 함유 실태)

  • Yang, Jeong Sun;Choi, Jin Hee;Choi, Seong Bong;Lee, Jong Han
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.268-278
    • /
    • 2007
  • Nitrite which can be derived from water for dilution of metal working fluid can induce nitroso compounds which can be classified as carcinogen, if it co-exists with ethanolamines added for pH control in metal working fluid. The survey of nitrite, nitrate and nitroso-compounds level in 42 metal-working fluids collected from 17 factories was done by ion chromatography and gas chromatography with mass detector. Diluted metal working fluid showed higher level of nitrite and nitrate compared with raw fluid. Nitrite was detected in 11 (52%) samples among 21 diluted solution. Three (14%) samples showed over German recommendation level ($20{\mu}g/mL$).N-nitrosodiethanolamine(NDELA) was detected in 18 samples among 21 diluted solution. Seven (33%) samples showed over German recommendation level ($5{\mu}g/mL$). The concentration of NDELA was correlated with nitrite ion ($R^2=0.453$, n=19).

Dynamic Characteristic Analysis Procedure of Helicopter-mounted Electronic Equipment (헬기 탑재용 전자장비의 동특성 분석 절차)

  • Lee, Jong-Hak;Kwon, Byunghyun;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.8
    • /
    • pp.759-769
    • /
    • 2013
  • Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.

Development of a High Heat Load Test Facility KoHLT-1 for a Testing of Nuclear Fusion Reactor Components (핵융합로부품 시험을 위한 고열부하 시험시설 KoHLT-1 구축)

  • Bae, Young-Dug;Kim, Suk-Kwon;Lee, Dong-Won;Shin, Hee-Yun;Hong, Bong-Guen
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.318-330
    • /
    • 2009
  • A high heat flux test facility using a graphite heating panel was constructed and is presently in operation at Korea Atomic Energy Research Institute, which is called KoHLT-1. Its major purpose is to carry out a thermal cycle test to verify the integrity of a HIP (hot isostatic pressing) bonded Be mockups which were fabricated for developing HIP joining technology to bond different metals, i.e., Be-to-CuCrZr and CuCrZr-to-SS316L, for the ITER (International Thermonuclear Experimental Reactor) first wall. The KoHLT-1 consists of a graphite heating panel, a box-type test chamber with water-cooling jackets, an electrical DC power supply, a water-cooling system, an evacuation system, an He gas system, and some diagnostics, which are equipped in an authorized laboratory with a special ventilation system for the Be treatment. The graphite heater is placed between two mockups, and the gap distance between the heater and the mockup is adjusted to $2{\sim}3\;mm$. We designed and fabricated several graphite heating panels to have various heating areas depending on the tested mockups, and to have the electrical resistances of $0.2{\sim}0.5$ ohms during high temperature operation. The heater is connected to an electrical DC power supply of 100 V/400 A. The heat flux is easily controlled by the pre-programmed control system which consists of a personal computer and a multi function module. The heat fluxes on the two mockups are deduced from the flow rate and the coolant inlet/out temperatures by a calorimetric method. We have carried out the thermal cycle tests of various Be mockups, and the reliability of the KoHLT-1 for long time operation at a high heat flux was verified, and its broad applicability is promising.