• Title/Summary/Keyword: 이음부의 두께

Search Result 70, Processing Time 0.047 seconds

The Experiment for Performance Evaluation of Column-rafter-purlin Connections of an Arch-type Plastic Multi-span Greenhouse (플라스틱 연동온실 기둥-서까래-도리 접합부의 성능 평가 실험)

  • Choi, Man-kwon;Ryu, Hee-ryong;Cho, Myeong-whan;Yu, In-ho;Kim, Seung-yu
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.473-479
    • /
    • 2020
  • In this study, the structural experiment was conducted with two types of specimens to investigate the mechanical behavior of the column-rafter-purlin connection of an arch-type greenhouse under monotonic loading. Based on the experimental results, the flexural performance was analyzed for two types of connections, and connection classification was attempted. Type B showed 77% of flexural performance compared to Type A, and both types showed that the rigidity and flexural strength did not reach the level of the full rigid. The behavior of the column-rafter-purlin connection was dominated by local buckling due to deformation of the weld and fasteners. As a result of connection classification by AISC standard, both Type A and B connections showed a result that did not meet the rigid connection performance assumed during design, and were classified as simple connection. Therefore, the connection performance evaluation and classification results show that the greenhouse design should be made in consideration of connection performance and in order to design a reliable greenhouse structure, a study on establishing clear design standards for the greenhouse connection is necessary.

The Technology of Laser Welding System Controller (고출력 레이저 용접 시스템 제어기술)

  • 김도열;최흥근;유석준;이승태
    • Journal of Welding and Joining
    • /
    • v.14 no.3
    • /
    • pp.20-28
    • /
    • 1996
  • 고밀도 에너지를 열원으로 이용하는 고출력 레이저로는 CO$_{2}$레이저와 Nd;YAG 레이저가 있다. 레이저는 열가공임에도 불구하고 빔의 스폿경을 작게하여 높은 에너지 밀도($10^{6}$ W/cm$_{2}$ 이상)을 얻을 수 있으므로 열영향이 작고 작은 변형범위내에서 용접을 할 수 있고 입력 에너지의 제어성이 좋아서 미세한 용접이 가능하게 하고, 빔폭 대비 용입깊이가 커서 깊은 용접 비드가 형성되며, 자동화가 용이하다는 장점이 있다. 특히 Nd;YAG 레이저의 경우는 광 섬유를 이용하므로서 에너 지의 시간 분할 및 에너지 분할을 할 수 있는 등 분기 및 배치가 용이하며 펄스의 활 용을 극대화 할 수 있는 장점이 있다. 그러나, 결점으로도 맞대기 용접의 경우 갭의 여유가 판두께, 초점위치, 빔모드에 따라 변화하는데 이는 빔 스폿이 작음에 따른 장점이 단점으로 작용하는 경우이다. 레이저 용접부의 비드 폭이 좁기 때문에 인장 강도가 모재의 인장강도보다 밑도는 것도 겹쳐서 용접된 이음 부분의 인장강도에 있 어서 단점이 되고 있다.

  • PDF

A Study on the Residual Stress in the Welded Joints with Different Details (용접상세의 변화에 따른 용접이음부의 잔류응력에 관한 연구)

  • Lim, Cheong Kweon;Park, Moon Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.4 s.37
    • /
    • pp.709-720
    • /
    • 1998
  • In order to study the distribution of welding residual stress through the plate thickness. experiment and analysis of fillet welding details were carried out. Especially, a residual stress in the weld root part of T-joint fillet weld whose measurement was difficult up to now was measured. By using the heat input and the number of the weld layers as parameters, the distribution of the 3-dimensional residual stress was investigated. As a result, we can say that with increasing the heat input, the residual stress in the weld toe and weld root barely changes. But, the area of the tensile residual stress became wide. Then, comparing a single pass with multi-pass weld method, it was found that the residual stress decreased more in multi-pass than in single pass. Moreover, it was found the thing that the area of tensile residual stress by multi-pass is lower than that by single-pass in the near weld part.

  • PDF

Permeability Characteristics of Geosynthetics Vertical Barrier Connections for the Prevention of Contaminants Diffusion (오염물질 확산방지를 위한 토목섬유 연직차수벽 연결부의 투수성능 평가)

  • Park, Jeong Jun
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.1-9
    • /
    • 2022
  • Purpose: In this study, we used hydrophilic waterstop used in geosynthetics vertical barrier system to evaluate the performance of impermeability under sealing conditions. Method: ASTM D5887 and ASTM D6766 were applied to determine the capability of the connection during the geosynthetics vertical barrier system. Hydrophilic waterstop was saturated in each solution and the weight, thickness, and volume changes were analyzed over elapsed time. Hydrophilic waterstop was installed at the geosynthetics vertical barrier system connection to evaluate the permeability characteristics. Results: As the expansion reaction time of hydrophilic waterstop increased relatively under saline conditions, the decrease in permeability also showed a smaller decrease in fresh water. Furthermore, the method of engagement of the geosynthetics vertical barrier system showed somewhat better performance of the impermeability due to the large pressure resistance caused by the roll joint type than interlock type. Conclusion: In urban pollutants, which can estimate the outflow of pollutants such as oil storage facilities and industrial complexes, proactive response technologies that can prevent the contaminant diffusion can significantly reduce the damage.

Strength and Deformation Capacities of Short Concrete Columns with Circular Section Confined by GFRP (GFRP로 구속된 원형단면 콘크리트 단주의 강도 및 변형 능력)

  • Cho, Soon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.1
    • /
    • pp.121-130
    • /
    • 2007
  • To investigate the enhancement in strength and deformation capacities of concrete confined by FRP composites, tests under axial loads were carried out on three groups of thirty six short columns in circular section with diverse GFRP confining reinforcement. The major test variables considered include fiber content or orientation, wrap or tube type by varying the end loading condition, and continuous or discontinuous confinement depending on the presence of vortical spices between its two halves. The circumferential FRP strains at failure for different types of confinements were also investigated with emphasis. Various analytical models capable of predicting the ultimate strength and strain of the confined concrete were examined by comparing to observed results. Tests results showed that FRP wraps or tubes provide the substantial increase in strength and deformation, while partial wraps comprising the vertical discontinuities fail in an explosive manner with less increase in strength, particularly in deformation. A bilinear stress-strain response was observed throughout all tests with some variations of strain hardening. The failure hoop strains measured on the FRP surface were less than those obtained from the tensile coupons in all tests with a high degree of variation. In overall, existing predictive equations overestimated ultimate strengths and strains observed in present tests, with a much larger scatter related to the latter. For more accuracy, two simple design- oriented equations correlated with present tests are proposed. The strength equation was derived using the Mohr-Coulomb failure criterion, whereas the strain equation was based on entirely fitting of test data including the unconfined concrete strength as one of governing factors.

A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection (철근 콘크리트와 강판 콘크리트 간 이질접합부로 구성된 구조물의 휨 및 전단거동 특성 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Lee, Jong Bo;Won, Deok Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.267-275
    • /
    • 2012
  • This paper describes the experimental study on the structural behavior of the joint plane between a RC(Reinforced Concrete) wall and a SC(Steel Plate Concrete) wall under out-of plane flexural loads and in-plane shear loads. The test specimens were produced with L and I shape to assess efficiently flexural and shear behavior of the structures. In order to consider dynamic loads such as earthquake, cyclic loading tests were carried out. As results of the out-of plane flexural tests, ductile failure mode of vertical bars was shown under a push load and the failure load was more than nominal strength of the specimen. And the latter test was performed to verify the variation which was composition presence of horizontal bars in the SC member. The test results showed that capacity of the specimens was more than their nominal strength regardless of composition presence of horizontal bars.

Evaluation of waterproof and durability of hydrophilic waterstop (수팽창 지수재의 방수 성능 및 내구성 평가)

  • Choi, Woo-Yong;Lee, Hyeun-Pil;Jun, Gy-Chan;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.2
    • /
    • pp.117-124
    • /
    • 2014
  • The interest in the use of shield TBM (Tunnel Boring Machine) on the tunnel excavation has been increased rapidly in Korea. The shield TBM tunnel is generally designed as non-drainage tunnel. Consequently, if water leakage through the segment joints happens, big problems on the usage and stability of tunnel can be occurred. In this study, the variation of waterproof capacity of hydrophilic waterstop by the construction error and excessive displacement of segment was studied firstly. Secondly, the decrease of durability of hydrophilic waterstop by the sulphate and chloride contained in the groundwater and seawater was investigated. The results showed that if the angle discordance at the segment joints is beyond the 2 degree, the proper waterproof capacity of hydrophilic waterstop can not be guaranteed. In addition, if the hydrophilic rubber waterstop is exposed to the sulphate for a while, the proper durability of hydrophilic waterstop can not be expected.

An Experimental Study on the Fatigue Behavior of T-Type Tension Joints with High Tension Bolt (고장력볼트 T-인장이음의 피로거동에 관한 실험적 연구)

  • Lee, Seung Yong;Choi, Jun Hyeok
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.459-465
    • /
    • 2016
  • In this paper, it was performed the fatigue test to examine the effect of cyclic loading for the simple T-joint. Axial force of bolt by clamping and the change of the force by applied load were measured in the joint. And the bolt force, the failure mode and the fatigue strength under cyclic loading were investigated. The parameters of the tension joint were set to be the flange thickness and the diameter of bolt to a different stiffness of the joint in response to the combination. From the fatigue test, failure mode of tensile joints under cyclic loading could be evaluated using a static ultimate load of the specific failure mode in EC3. The fatigue strength of the tension joints was considerably higher than the fatigue strength of the EC3(36) that does not consider a lever action. However, the additional axial force by lever action occurs to an increase in the axial force of the bolt it requires a careful evaluation of the fatigue strength.

An Experimental Study on the Prediction of Yield Load Using Ring Analysis Method in Circular Tubular X-Type Cross Sections (링해석법에 의한 X형 강관 격점부의 항복하중 예측에 관한 실험적 연구)

  • Park, Il Min;Na, Seon Hong
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.1 s.38
    • /
    • pp.43-54
    • /
    • 1999
  • The divergence connection between steel circular tubes is widely used in such structures as factory facilities, steel circular hollow section truss, and off-shore tower. Steel circular hollow section (SCHS) have close section, and it makes their per-unit production expense higher than open sectioned products like L-shape, H-shape steels, but the sectional resistance of SCHS against vertical compression and torsion is very high. Despite the structural merits of SCHS, however, many engineers dislike to use them in their design because of uncertainty regarding the stress distribution and deformation behavior at their connections. Therefore, this thesis dealt with X-type connections, the most common forms of connection, and studied their load-deformation relationship. It observed how to show the load-deformation relationship at steel circular tube connections according to the diameter-thickness ratio (D/T) of the chord and diameter of branch-diameter of chord ratio (d/D) and suggested prediction yield load using by ring analysis method.

  • PDF

State-of-the-art Node of Freeform Structure (프리폼 구조의 노드 기술 현황 분석)

  • Lee, Kyoung Ju;Oh, Jin Tak;Kim, Sang Dae;Ju, Young Kyu
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.153-153
    • /
    • 2011
  • 현대 건축은 기능적이고 합리적이었지만 획일적이었던 박스형 건축에서 탈피해 형태와 공간에 있어서 다양한 변화를 시도하고 있다. 특별한 건축물의 실현을 위해 각 나라의 기술력은 급속한 발전을 이루었고, 보다 더 독특한 건축물에 대한 관심은 비정형 건축물에 대한 관심의 증대로 이어지고 있다. 이러한 비정형 건축물에 적합한 구조로써 프리폼(Free-Form) 구조가 있다. 프리폼 구조로 입체골조(Double Layered Structure)를 많이 사용하였으나, 최근 유리로 되어 투명하고 기하학적 모양의 건축물을 추구함에 따라 평면골조(Single Layered Structure)가 증가하고 있는 추세이다. 평면골조는 축력 지배형과 모멘트 지배형으로 분류할 수 있고 프리폼 구조의 구성 요소 중 가장 취약하고 중요한 부분은 노드이다. 본 연구에서는 프리폼 구조 중 가장 큰 관심이 고조되고 있는 평면골조 모멘트 지배형의 노드에 대한 국내외 기술 분석을 통해 향후 연구 방향성을 제시하고자 한다. 입체골조는 하나의 노드에 여러개의 부재가 3차원으로 결합되어야 하기 때문에 다른 골조 시스템에 비해 노드부가 복잡하지만, 건축물의 외관을 유리로 하여 투명하게 하고 비틀리고 구부러진 구조물에 대한 건축적 요구가 많아짐에 따라 평면골조의 인기가 높아지고 있다. 이러한 시대의 흐름에 발맞추어 건물의 구조적, 기하학적 요구를 충족시키기 위해 다양한 노드 시스템이 개발 중이며, 가해지는 하중의 특성에 따라 축력 지배형과 모멘트 지배형으로 구분하여 노드의 양상을 분류할 수 있다. 축력 지배형의 대표적인 시스템은 다이아그리드(Diagrid)이다. 축력 지배형 프리폼 구조의 노드는 전체 구조물의 하중을 축력으로 받아 모두 전달해야 하기 때문에 크기가 크고 가새가 2~4개층에 걸쳐서 설치되기 때문에 중량이다. 모멘트 지배형 노드를 갖는 프리폼 구조의 형태는 대부분 지붕 구조로써 지붕 자체의 하중만을 견디도록 설계된다. 따라서 노드부와 노드에 붙는 부재들이 가볍기 때문에 사람이 들 수 있고 노드의 크기가 작아 시공성이 좋으며 대량 생산이 가능하다는 장점이 있다. 노드의 형태는 힘의 흐름과 쓰임에 따라 다양하다. 평면골조 모멘트 지배형의 노드는 접합방식에 따라 Splice node connection과 End-Face node connection 두 가지로 분류할 수 있다. Splice node connection은 각 부재의 종축으로 노드와 구조부재 사이에 이음재를 두어 연결하고, 연결 형태에 따라 전단력을 전달할 수 있는 1~2개의 접촉면이 생긴다. 전단응력을 받는 볼트로 이음재를 이어 조립하거나 용접으로 접합할 수 있다. 대표 노드로, SBP-1, SBP-2와 POLO-1 등이 있다. End-Face node connection은 각 연결된 부재의 단부와 노드 사이의 연결면은 종축방향의 수직이고, 인장응력을 받는 볼트를 사용하거나 용접에 의해 접합할 수 있다. 대표 노드로 SBP-4, WABI-1, MERO-1(Cylinder), MERO-2(Block), MERO-4(Double Dish) 등이 있다. 본 기술 현황 분석을 통해 현재 개발된 노드를 분류하고 가장 관심이 높은 Single Layer 모멘트 지배형 노드를 비교, 분석하였다. 최근 건물의 경향을 반영한 프리폼 구조를 실현하기 위해서 필수적인 노드의 개발은 국외에서 활발히 연구되고 있지만 그 기술이 개방되어 있지 않다. 국내에서는 동대문 디자인 플라자에 새로운 노드를 적용하고 고려대학교에서 모멘트 지배형 노드를 개발하는 등 발전 가능성을 보이고 있지만 국외 사례들에 비하면 아직 초기 단계라 할 수 있다. 따라서 현장 용접을 지양하고 공장 제작하여 현장에서 조립하며, 프로젝트 별로 상이한 노드를 사용하는 것이 아닌 다양한 요구를 효과적으로 수용하는 구조 효율성을 향상시킨 노드 상세의 개발이 이루어져야 할 것이다.

  • PDF