• Title/Summary/Keyword: 이음관

Search Result 65, Processing Time 0.027 seconds

An Analysis of Engine Failures Using Multivariate Data Analysis Method (다변량해석법을 이용한 기관고장분석)

  • 윤석훈
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.4
    • /
    • pp.198-203
    • /
    • 1987
  • The basis of all approaches to improve reliability of marine engines exists in analyzing the field data of troubles and failures on marine engines. This paper analyses the data of troubles and failures on marine engines by Principal Component Analysis Method, one of Multivariate Data Analysis Method. The total number of data investigated is 211 and the observation period is 9 years. The analyzed factors are categorized among five groups respectively; electric.automatic control equipments, auxiliary machinery, pipings, refrigerators.air conditioners, and main engine. The failures in main engine are discovered by a definite fact of disorder, on the contrary, the failures in auxiliary machinery, refrigerators and air conditioners are discovered by sensible judgement of the operators.

  • PDF

Seismic Stability Evaluation of Bellows Type Expansion Joints Piping System(350A) (350A 벨로우즈형 신축관이음의 내진특성 평가)

  • Son, In-Soo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.4_2
    • /
    • pp.653-659
    • /
    • 2020
  • In this study, seismic verification of the bellows used in the plant field was conducted. The pressure used in the analysis was analyzed by applying the design pressure of 15.7bar. For the seismic analysis, the natural frequency of the bellows system was obtained and the stability of the system was evaluated by static seismic analysis comparing the lowest order natural frequency with the dominant frequency of 33 Hz. The material of the bellows system is STS304, and the safety factor is obtained in comparison with the allowable stress. For the seismic analysis, the design response spectrum was prepared and the maximum acceleration was applied to the static seismic analysis and the stability of the entire system was confirmed. Compared to the structural analysis results, the maximum stress of the bellows system increased by about 16.4% and the maximum strain increased by about 3 times when seismic analysis was performed.

Study of Structural Reliability of Pipe-Fitting Collet Tool (배관용 관 이음쇠 내외경 동시 교정툴의 신뢰성 평가)

  • Kim, Chang-Uk;Park, Jin-Chul;Song, Jung-Il
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.4
    • /
    • pp.140-145
    • /
    • 2015
  • In the present study, the structural safety of the bolt portion and collet tool structure of the pipe-fitting tool is analyzed by using the finite element technique. Two forces as piston forces with the magnitude of 187.5 Tons are applied to the inner and outer portions of the collet tool, respectively. A structural load of 750 Tons is applied to the bolt portion. In the analysis results, it is found that the structure becomes safe under the current loading conditions. The reliability rating of the pipe is calculated in this study. The material properties of the actual material are evaluated by using mechanical testing. Therefore, the material properties are used to carry out static structural and optimization analysis.

The Methods of Rail Joint Detection and Gap Signal Compensation for Levitation Control of Urban Maglev (도시형 자기부상열차 부상제어를 위한 궤도 이음매 검출 및 공극 신호의 보상 방법)

  • Kim, Haeng-Koo;Lee, Jong-Min;Kang, Byung-Kwan;Kim, Kuk-Jin;Kim, Chun-Kyung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.922-927
    • /
    • 2007
  • The present urban maglev which has been developed in Korea is controlled by 4-edge control method over each bogie. The control output which is derived from two gap sensors and one vertical acceleration sensor controls magnet to maintain a nominal gap. But, the gap signal acts as a big disturbance in rail joint though two gap sensors are used and finally result in unstable response and poor ride comfort. This paper treats of a method to compensate the gap signal in rail joint for the levitation control of urban maglev. The physically abnormal change of gap is detected when one gap sensor passes a rail joint, the disturbance of gap in rail joint is estimated. Finally the disturbance in gap signal is eliminated by processing the information of vehicle speed and estimated disturbance in when the other gap sensor passes a rail joint.

  • PDF

A Study on the Fatigue Strength of a Welded Joint with Misalignment of a U-type Trough Rib in a Steel Deck Plate (강상판(鋼床版) U형(形) 트라프리브 단차용접(段差熔接)이음부(部)의 피로강도(疲勞强度)에 관(關)한 연구(硏究))

  • Lee, Dong Uk;Seo, Won Chan
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.13-20
    • /
    • 1996
  • With the adoption of welded joints rather than bolted joints, we investigate the fatigue strength and the fatigue crack initiation of U-type trough rib and welded specimen with misalignment in a steel deck plate. The stress concentration factor of welded specimens with a misalignment is also verified by a finite element method. The main conclusions obtained from this study are as follows Experimental results of full-scaled U-type trough rib models have indicated that fatigue life depends on misalignments of welded joints in steel deck plate ; The more misalignments are, the less the fatigue life is. It has also shown that fatigue crack propagates from the welded root to the bead surface. We have also obtained the same results from both the fatigue test of welded specimens with a misalignment and the stress analysis of a finite element method.

  • PDF

Effects of Mandrel and Die Shape in Seamless Tube Drawing (이음매 없는 관 인발에서 맨드렐과 금형 형상의 영향)

  • Lee, Y.S.;Yoon, S.H.;Yoon, D.J.
    • Transactions of Materials Processing
    • /
    • v.20 no.8
    • /
    • pp.562-567
    • /
    • 2011
  • This paper deals with effects of certain important factors in a tube drawing operation, such as the use of a mandrel, die radius and tangential angle at die outlet, on the deformation behavior of a small-diameter seamless tube. Both experimental and finite element simulation studies are carried out to assess the effects of the above parameters. Experiments and finite element predictions are compared. The use of a mandrel simplifies the design of tube drawing, but also induces some difficulties from increased process complexity. The effects of die outlet tangential angle and radius are discussed in detail.

The Comparison Analysis of Welding Techniques in Water Distribution Steel Pipes (상수도강관 용접접합의 방법별 비교분석)

  • Kim, Eung-Seok;Jeong, Won-Sik;Kim, Sung-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2859-2865
    • /
    • 2011
  • The welded connection is known as an essential factor for establishing qualified construction and/or maintenance of wrapped steel pipe. In this study, welded connection conditions in the coated pipes with large diameter (over 700 mm) in Korea water distribution systems were estimated for suggesting technically and economically available welded connection method. For the study analysis, current steel pipe usage and accident cases were investigated. In addition, the characteristics of each welded connection method and automatic or manual connection techniques were also compared and estimated. As results, automatic welded connection method is superior than manual welded connection method in aspect of pure construction cost (average 9%) or pure welded connection cost (average 13.5%). When the poor welding-working situations in Korea are considered such as high tolerance of out-of-roundness in KS regulation, a number of lap joint welded connections, the real cost benefits of automatic welded connection should be much higher than those of manual welded connections.

Evaluation of Seismic Performance of Valve Chamber System by Shaking Table Tests (진동대 실험을 통한 밸브실 시스템의 내진성능 평가)

  • Young-Soo Jeong;Kyeong-Seok Lee;Jin-Seok Yu;Hyung-Chae Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • The structural safety of expansion joints for piping systems has been drawing attention owing to ruptures and leaks of water pipes caused by earthquakes and road subsidence at soft ground. In general, metal bellows are installed as expansion joints to prevent various damages in the piping system. In this study, the seismic performance of a valve chamber system was evaluated by performing earthquake shaking table tests. To validate the benefits to structural safety of metal bellows in connecting steel pipes to valve chambers, the seismic tests were conducted on expansion joints (bellows) and general pipping, and the results were compared for durability. Strain gauges were attached to measure the effects of the input motion. As a result of the shaking table test, it was confirmed that the strain of the valve chamber structure and inflow or outflow steel pipes were decreased in 1/100, 1/20 by applied to the expansion joints.

A study on the flow resistance in the various fittings for non-newtonian fluid (비뉴우튼유체의 관이음음 유동저항에 관한 연구)

  • ;;Kim, Chun Sik
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.4
    • /
    • pp.151-157
    • /
    • 1979
  • An experomental study on drg reduction in the rough tubes is presunted using the drrective drag reducing proymer solutions. The friction factors of the rough tubes follow the maximum drag reduction asymptote for the lower Reynolds numbers in the turbulent flow. However, as the Reynols number is increased the rougher tube results deviate from the maximum drag rduction asymptote sooner than the less rough tube results. There appears a systematic deviation from the maximum drag reduction asymptote depending on the relative roughness just as friction factors for the Newtonian hluid inthe rough tubes exhibit in the turbulent region. The minor loss results inthe various fittings such as elbows, tees, and gate valves are presunted The fittings show higher values of the loss coefficient in the drag reducing polymer solutions than in the Newtonian fluid, which is quite contrary to the drag reduction phenomenon in the straight tubes. The eqivalent length of the fittings for the drag reducing polymer solutions is many times longer than that for Newtonian fluids due to the increase of the loss coefficient and the decrease of the friction factor. It is speculated that the solid-like behavior of the polymer solutions in the abruptly changing folw passage plays a significant role in increasing the loss coefficient.

A Study on the Manufacturing, Mechanical Properties,Abrasion Resistance, and Slow Crack Growth Resistance of the Recycled Polyethylene/Fly Ash Composites (재생 폴리에틸렌/비산회 분말 충전 복합체 제조와 기계적 물성, 내마모성 및 저속균열성장 저항성에 관한 연구)

  • Kye, Hyoung-San;Shin, Kyung-Chul
    • Elastomers and Composites
    • /
    • v.46 no.4
    • /
    • pp.335-342
    • /
    • 2011
  • The virgin and recycled polyethylene composites with various ratio of fly ash were manufactured by using a fully intermeshing co-rotating twin screw extruder for the reuse of fly ash from power plant and post-consumed polyethylene. Fly ash were blended with virgin HDPE and recycled polyethylene at the weight fraction of 0 to 40 wt.%. Mechanical properties such as yield strength, abrasion resistance, and slow crack resistance were measured with ISO and ASTM standards. The experimental results for the various composites showed that the elongation at break and the yield stress of the composites decreased with increasing fly ash contents. Generally, the abrasion resistance of PEs decreased with increasing sandpaper grits but the abrasion resistance of the composites increased with fly ash content at finer abrasive surface. The slow crack growth resistance of virgin HDPE, recycled JRPE and the JRPE composite showed higher slow crack growth resistance up to 50% of load at notch depth of 20% and 30%, but KRPE and the KRPE composite showed much lower resistance than virgin HDPE, JRPE and the JRPE composite. Time to break, measured with NCLS test method, of all PEs and the composites satisfies the regulation of Korean Industrial Specification for sewer pipe and support application.