• Title/Summary/Keyword: 이용희

Search Result 8,880, Processing Time 0.039 seconds

Correlation of Unmet Healthcare Needs and Employment Status for a Population over 65 Years of Age (65세 이상 인구의 고용형태와 의료요구 미충족 경험률의 관련성)

  • Kang, Jeong-Hee;Kim, Chul-Woung;Seo, Nam-Kyu
    • 한국노년학
    • /
    • v.37 no.2
    • /
    • pp.281-291
    • /
    • 2017
  • The present study aimed to investigate the rate of unmet healthcare needs for elderly over the age of 65 years, as well as analyze the relevance between employment status and unmet healthcare needs due to financial reasons. With regard to the study method, a logistic regression analysis was performed to investigate the correlation between employment status and unmet healthcare needs due to financial reasons, targeting 5,528 subjects over the age of 65 years. The results showed that the rate of unmet healthcare needs was 18.9%, in which the rate of unmet healthcare needs due to financial reason was 8.1%. The rate of unmet health needs was higher for temporary workers(ORs=1.75) than for retirement workers. However, the rate of unmet healthcare needs caused by financial reasons was higher among day workers(ORs=1.92). In conclusion, in order to prevent unmet healthcare needs for senior Korean patients, it is necessary to not only improve the income security system for the elderly, but also improve the occupational form and level of income of these economically active citizens, considering the increase in average life expectancy. Moreover, it is also necessary to reinforce health insurance coverage systems for settling medical expenses.

Data issue and Improvement Direction for Marine Spatial Planning (해양공간계획 지원을 위한 정보 현안 및 개선 방향 연구)

  • CHANG, Min-Chol;PARK, Byung-Moon;CHOI, Yun-Soo;CHOI, Hee-Jung;KIM, Tae-Hoon;LEE, Bang-Hee
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.4
    • /
    • pp.175-190
    • /
    • 2018
  • Recently, policy of the marine advanced countries were switched from the preemption using ocean to post-project development. In this study, we suggest improvement and the pending issues when are deducted to the database of the marine spatial information is constructed over the GIS system for the Korean Marine Spatial Planning (KMSP). More than 250 spatial information in the seas of Korea were processed in order of data collection, GIS transformation, data analysis and processing, data grouping, and space mapping. It's process had some problem occurred to error of coordinate system, digitizing process for lack of the spatial information, performed by overlapping for the original marine spatial information, and so on. Moreover, solution is needed to data processing methods excluding personal information which is necessary when produce the spatial data for analysis of the used marine status and minimized method for different between the spatial information based GIS system and the based real information. Therefore, collection and securing system of lacking marine spatial information is enhanced for marine spatial planning. it is necessary to link and expand marine fisheries survey system. It is needed to the marine spatial planning. The marine spatial planning is required to the evaluation index of marine spatial and detailed marine spatial map. In addition, Marine spatial planning is needed to standard guideline and system of quality management. This standard guideline generate to phase for production, processing, analysis, and utilization. Also, the quality management system improve for the information quality of marine spatial information. Finally, we suggest necessity need for the depths study which is considered as opening extension of the marine spatial information and deduction on application model.

Analysis of Light Transmittance according to the Array Structure of Collagen Fibers Constituting the Corneal Stroma (각막실질 콜라겐섬유의 배열구조에 따른 광투과율 분석)

  • Lee, Myoung-Hee;Kim, Young-Chul
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.561-568
    • /
    • 2018
  • Purpose : The size and regular array of the collagen fibers in the corneal stroma have very close correlation with transparency. Simulation was carried out to investigate the change of light transmittance according to the array structure and collagen fiber layer thickness. Methods : The collagen fibers in corneal stroma were arranged in regular hexagonal, hexagonal, square and random shapes with OptiFDTD simulation software, and the light transmittance was analyzed. In square array, the light transmittance according to the density change was confirmed by when the number of collagen fibers in the simulation space was the same and the light transmittance was examined when the number and density of collagen fibers were changed. Results : When the number of collagen fibers is the same, the density becomes smaller and the thickness of the fibrous layer becomes thicker in order of arrangement of square, regular hexagonal, random and hexagonal. As a result of measuring the light transmittance by changing the array structure, the light transmittance measured at the detector at the same position was almost similar regardless of the array structure. In the detectors D0, D1, D2 and D3, the maximum transmittance is shown in square, hexagonal and square, regular hexagonal and regular hexagonal array structure, and the minimum transmittance is hexagonal, random, hexagonal and square, and square array structure. However, the difference between the maximum transmittance and the minimum transmittance was almost the same within 1%. When the number of collagen fibers was the same, the light transmittance of the rectangular array structure decreased with increasing fiber layer thickness. And as the thickness increased, the light transmittance decreased more when the number of collagen fibers decreased. Conclusion : Even though the collagen array structure changed, the light transmittance is almost similar regardless of the arrangement structure. However, as the array structure was changed, the thickness of the collagen fiber layer changed, and as the thickness increased, the light transmittance decreased. In other words, the transparency of the corneal stroma is more closely related to the thickness of the fibrous layer than the array of collagen fibers.

Variation Analysis of Sea Surface Temperature in the East China Sea during Summer (동중국해에서 하계 표층수온의 변화 분석)

  • Park, GwangSeob;Lee, Taehee;Son, Young Baek
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_1
    • /
    • pp.953-968
    • /
    • 2018
  • In order to understand the change of surface water temperature in the East China Sea (ECS), this study analyzed the relationship between sea surface temperature (SST), air temperature (AT) and heat flux using satellite and model reanalysis data from 2003 to 2017. SST in the ECS showed the lowest (average : $13.72^{\circ}C$) in March and the highest (average : $28.12^{\circ}C$) in August. AT is highly correlated with SST and shows a similar seasonal change. In August, SST is higher than AT and then continuously higher than AT until winter. To analyze the change of the summer SST in the ECS, we used the SST anomaly value in August to classify the periods with positive (04', 06', 07', 13', 16', 17') and negative (03', 05', 08', 09', 10', 11', 12', 14', 15') values. Spatial similarity between the two periods indicates that SSTs are relatively larger variations in the northern part than in the southern part, and in the western part than in the eastern part in the study area. AT and net heat flux values also show similar changes with SST. However, the periods of the positive SST anomaly have the relatively increasing SST, AT and heat flux values compared to the periods of the negative SST anomaly in the summer season of the ECS. Although the change of SST in the summer season generally well correlates with AT, there were the periods when it was different from general trends between SST and AT (10', 12', 15', 16'). SST in August 2010 and 2012 decreased by $0.5^{\circ}C$ from AT. It suggests that the decreasing SST was considered to be caused by the effects of the typhoon passing through the study area. In August 2015, AT was relatively lower than SST (> $0.5^{\circ}C$), which is might be weakening of the East Asian Summer Monsoon. In August 2016, SST and AT show the highest values during the whole study periods, but SST is higher than AT (> $1^{\circ}C$). From satellite and heat flux data, the variations of SST have been shown to be relatively higher in the area of the expansion Changjiang Diluted Water (CDW) originated from the China coast. More research is needed to analyze this phenomenon, it is believed as not only the effect of rising AT but also the expansion of the low-salinity water.

A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers (핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구)

  • Lee, Wanghui;Ahn, Sungmin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.271-281
    • /
    • 2019
  • This study investigated the shielding efficiency of various types of shielding materials and measured the dose by organ using the phantom. Results of Shielding Efficiency Measurement Using Personal Radiation Meter. Among the various shielding materials, 1.1 mm RNS-TX composed of nano tungsten showed the highest shielding efficiency and 0.2 mm lead shielding showed the lowest shielding efficiency. 99mTc 30 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 20.53 mSv without radiation protective clothing, 8.75 mSv when wearing 0.25 mm Pb protective clothing, 6.03 mSv when wearing 0.5 mm Pb protective clothing. 131I 2 mCi mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 7.71 mSv without radiation protective clothing, 4.88 mSv when wearing 0.25 mm Pb protective clothing, 2.79 mSv when wearing 0.5 mm Pb protective clothing. 18F 5 mCi was exposed to the phantom for 120 minutes and the result of the measurement of the organs. 16.39 mSv without radiation protective clothing, 15.84 mSv when wearing 0.25 mm Pb protective clothing, 12.52 mSv when wearing 0.5 mm Pb protective clothing. None of the radiation workers working in the nuclear medicine department exceeded the dose limit. However, when compared with other workers in the hospital, they showed a relatively high dose. Therefore, it is necessary to prepare measures to reduce and manage the dose of radiation workers in the nuclear medicine department through the wearing of radiation protective clothing made of lightweight, shielding material with good shielding efficiency, circulation task, task sharing, and substitution equipment such as auto dispenser.

An investigation Of IntraFraction Motion Correction For Lung Stereotactic Body Radiation Therapy By Using IntraFraction Cone Beam Computed Tomography (폐암 환자의 정위적 체부 방사선 치료 시 IntraFraction CBCT를 이용한 치료 중 자세 오차 교정에 대한 고찰)

  • Song, Hyeong Seok;Cho, Kang Chul;Park, Hyo Kuk;Yoon, Jong Won;Cho, Jung Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Purpose: The purpose is to correct for position errors caused by long treatment times. By correcting the target motion that can occur during lung SBRT using IntraFraction CBCT. Methods and materials: We analyzed retrospectively the IFM data of 14 patients with two treatment arc in the treatment plan for lung cancer with stereotactic radiotherapy. An IntraFraction Motion was applied to the Arccheck phantom to acquire the Gamma index data. Results : IntraFraction Motion during the first treatment arc is in the left-right(LR), superiorinferior(SI), anterior-posterior(AP) directions were $0.16{\pm}0.05cm$, 0.72 cm(max error), $0.2{\pm}0.14cm$, 1.26 cm, $0.24{\pm}0.08cm$, 0.82 cm and rotational directions was $0.84{\pm}0.23^{\circ}$, $2.8^{\circ}$(pitch), $0.72{\pm}0.23^{\circ}$, $2.5^{\circ}$(yaw), $0.7{\pm}0.19^{\circ}$, $2^{\circ}$(roll). IntraFraction Motion during the second treatment arc is in the LR, SI, AP directions were $0.1{\pm}0.04cm$, 0.37 cm, $0.14{\pm}0.17cm$, 2 cm, $0.12{\pm}0.04cm$, 0.5 cm and rotational directions was $0.45{\pm}0.12^{\circ}$, $1.3^{\circ}$, $0.37{\pm}0.1^{\circ}$, $1^{\circ}$, $0.35{\pm}0.1^{\circ}$, $1.2^{\circ}$. Gamma index pass rates were $82.64{\pm}10.51%$, 48.4 %. Conclusions : In this study, we examined the validity of IntraFraction Motion correction in lung SBRT and the efficiency of IntraFraction CBCT. Due to the nature of SBRT treatment, IFM may increase due to the increased treatment time. It is believed that the increase in IFM with the increase in treatment time can be improved with the use of FFF Beam and additional position correction using CBCT during treatment.

Complete genome sequence of Lachnospiraceae bacterium KGMB03038 (=KCTC 15821) isolated from healthy Korean feces (건강한 한국인 분변으로부터 분리된 Lachnospiraceae bacterium KGMB03038 (=KCTC 15821) 균주의 유전체 염기서열 초안)

  • Kim, Ji-Sun;Kang, Se Won;Han, Kook-Il;Lee, Keun Chul;Eom, Mi Kyung;Suh, Min Kuk;Kim, Han Sol;Lee, Ju Huck;Park, Seung-Hwan;Park, Jam-Eon;Oh, Byeong Seob;Yu, Seung Yeob;Choi, Seung-Hyeon;Ryu, Seoung Woo;Lee, Dong Ho;Yoon, Hyuk;Kim, Byung-Yong;Lee, Je Hee;Lee, Jung-Sook
    • Korean Journal of Microbiology
    • /
    • v.55 no.3
    • /
    • pp.289-292
    • /
    • 2019
  • Lachnospiraceae bacterium KGMB03038 (=KCTC 15821) belonging to the class Clostridia in phylum Firmicutes, was isolated from a stool sample of a healthy Korean. Herein, we report the complete genome sequence of strain KGMB03038 analyzed using the PacBio Sequel platform. The genome comprises of 3,334,474 bp with G + C content of 47.8%, which includes 3,099 predicted protein-coding genes, 12 ribosomal RNAs, 54 transfer RNAs, and 4 ncRNAs. Genome analysis revealed that strain KGMB03038 possesses a number of genes involved in hydrolysis of carbohydrates, including mono-, di-, and oligo-saccharides, and biosynthesis of various amino acids.

Manufacturing Techniques of a Backje Gilt-Bronze Cap from Bujang-ri Site in Seosan (서산 부장리 백제 금동관모의 제작기법 연구)

  • Chung, Kwang Yong;Lee, Su Hee;Kim, Gyongtaek
    • Korean Journal of Heritage: History & Science
    • /
    • v.39
    • /
    • pp.243-280
    • /
    • 2006
  • At the Bujang-ri Site, Seosan, South Chungcheong Province, around 220 archaeological features, including semi-subterranean houses and pits of Bronze Age and semi-subterranean houses, pits, and burials of Baekje period had been identified and investigated. In Particular, mound burials No. 5 of 13 of Baekje mound burials yielding a gilt-bronze cap along with other valuable artifacts drew international scholarly attention. The gilt-bronze cap from the mound burial No. 5 is a significant archaeological data not only in the study of Baekje archaeology but also in the study of international affairs and exchange at that time. At the time of exposure, the gilt-bronze cap was already broken into a number of pieces and seriously damaged by corrosion, and hardening and urethane foam were necessary in the process of collecting its pieces. Ahead of main conservational treatments on cap, X-ray photograph and CT(computerizes tomography) were taken in order to examine interior structure of the cap and to decide appropriate treatments. In the five layers identified in the profile of cap, a textile layer was set between a metal and a layerof bark of paper birch for avoiding direct contact of the metal and the bark of paper birch. Analyses were executed for examining textile layer and a layer of fibroid material. According to microscopic analysis, while the textile layer consisted of the simplest plain fabric with one fold among three kinds of textile structures, the layer of fibroid material was mixed with two or three kinds of fibers. A comparative analysis with standard sample using FT-IR (Fourier Transform Infrared Spectroscopy) announced that both textiles and fabrics were hemp. Analysis of kind of the paper birch resulted in barks of paper birch with 15 fold. A metallographic microscope, SEM, and WDS were used for the analysis of microscopic structures of plated metal pieces. While amalgam plating was treated as a plating method, the thickness of the plated layer, a barometer of plating technique, was ranged from $1.72{\mu}m$ to $8.67{\mu}m$. The degree of purity of gold (Au) used in plating was 98% in average, and less than 1% of silver (Ag) was included.

Studies on Antioxidant, Anti-inflammatory and Whitening Effects of Oriental Herbal Extracts (Mix) including Eucommiae cortex (두충을 포함하는 한방추출물(Mix)의 항노화, 항염, 미백 효능 활성에 관한 연구)

  • Choi, Da Hee;Kim, Mi Ran;Kim, Min Young;Kim, Ho Hyun;Park, Sun-Young;Hwang, Hyung Seo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.1
    • /
    • pp.37-47
    • /
    • 2019
  • Recently, due to the increase in skin diseases caused by particulate matter, endocrine disruptor and environmental changes, the trend of development of cosmetic materials has been shifting to the more safe and effective ingredients based on natural materials rather than existing synthetic compounds like steroids and antihistamines. This study aimed to develop a new natural cosmetic materials using oriental herbs such as Eucommiae cortex, Alpinia oxyphylla Miquel and Bombyx batryticatus. First, DPPH assay was performed to examine the antioxidative activity of the herbal extract (Mix) and 98.8% DPPH radical scavenging activity was confirmed at $400{\mu}g/mL$ concentration of it. In order to confirm the whitening efficacy of oriental herbal extracts(mix), the amount of melanin synthesized after stimulation of ${\alpha}-MSH$ with B16F10 cells was measured. Results showed that it was decreased to 27.1% comparing with the only ${\alpha}-MSH$ treated group, which confirmed the whitening efficacy. Also, both nitric oxide(NO) production and iNOS and COX-2 expression were significantly reduced in RAW264.7 macrophages activated by LPS in the presence of the extracts(Mix). The mRNA expression of the inflammatory cytokines such as $IL-1{\alpha}$, $IL-1{\beta}$, IL-6, and $TNF-{\alpha}$ was also analyzed to confirm the inhibition effect of the extracts on inflammation. Finally, to confirm the enhancement of skin barrier function, the expression of claudin 1 gene, a tight junction protein, was observed using human keratinocyte HaCaT cells and increased as concentration dependent manner. From these results, it is concluded that the oriental herbal extracts(Mix) containing Eucommiae cortex, Alpinia oxyphylla Miquel and Bombyx batryticatus is effective for antioxidant, anti-inflammation, skin whitening, and skin barrier and thus could be applied as a new natural cosmetic material.

Prediction of Propylene/Propane Separation Behavior of Na-type Faujasite Zeolite Membrane by Using Gravimetric Adsorption (중량식흡착 거동에 기초한 Na형 Faujasite 제올라이트 분리막의 프로필렌/프로페인 분리 거동 예측 연구)

  • Hwang, Juyeon;Min, Hae-Hyun;Park, You-In;Chang, Jong-San;Park, Yong-Ki;Cho, Churl-Hee;Han, Moon-Hee
    • Membrane Journal
    • /
    • v.28 no.6
    • /
    • pp.432-443
    • /
    • 2018
  • In this study, propylene/propane separation behavior of Na-type faujasite zeolite membranes is predicted by observing gravimetric adsorptions of propylene and propane on zeolite 13X. The gravimetric adsorptions were measured by using a magnetic suspension balance (MSB) at temperatures of 323, 343, 363 K and a pressure range of 0.02-1 bar. The pressure was increased at 0.1 bar intervals. As adsorption temperature increased, adsorptions of propylene and propane decreased and propylene/propane adsorption selectivity increased. Also, the diffusion coefficients of propylene and propane were increased as the adsorption temperature increased, following the Arrhenius equation. The maximum propylene/propane diffusion selectivity was 0.9753 at 323 K. The perm-selectivity was calculated from the adsorption data of zeolite 13X and compared with the perm-selectivity measured in the single gas permeation experiment for the Na-type faujasite zeolite membrane. The maximum values for the calculated and measured perm-selectivities were observed at a temperature of 323 K. It could be concluded that the prediction of propylene/propane separation of surface diffusion-based membrane by using gravimetric adsorption data is reasonable. Therefore, it is expected that this prediction method can be applied to the screening of adsorption-based microporous membrane for propylene/propane separation.