• Title/Summary/Keyword: 이용흠

Search Result 476, Processing Time 0.032 seconds

Comparison between Single and Co-culture of Adipocyte and Muscle Cell Lines in Cell Morphology and Cytosolic Substances (지방과 근육 세포주의 단독 및 공동배양을 통한 세포형태학 및 세포물질 비교 연구)

  • Choi, Chang-Weon;Cho, Won-Mo;Yeon, Seong-Heum;HwangBo, Soon;Song, Man-Kang;Park, Sung-Kwon;Baek, Kyung-Hoon
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.103-109
    • /
    • 2012
  • Present study was performed to investigate the effect of single and co-culture of adipocyte and muscle cell lines on cell differentiation. 3T3-L1 (adipocyte) and L6 (muscle) cell lines were single-cultured on the condition of 10% fetal bovine serum (FBS)/Dulbeco's modified eagle's medium (DMEM) for 48 h followed by culture within 5% FBS/DMEM as a growth media. Then, the growth media was replaced by differentiation media composed of 2% FBS/DMEM without additives in single- or co-culture of the 3T3-L1 and the L6 cells to induce differentiation of both cell types. In co-culture system, the 3T3-L1 and the L6 cells were grown in separated places by being seeded on a $0.4{\mu}m$ insert membrane and on the bottom of 6 well plate, respectively. Cell differentiation was measured using morphological investigation and cytosolic analysis of glycerol-3-phosphate dehydrogenase (GPDH; for 3T3-L1) and creatine kinase (CK; for L6). Based on the GPDH results, the presence of L6 cells did not stimulate 3T3-L1 differentiation showing more differentiation of 3T3-L1 cells in the single-culture compared to the co-culture condition. In contrast, 3T3-L1 cells in the co-culture promoted differentiation of L6 cells. Enzymatic analysis supported this result showing that 3T3-L1 cells showed statistically (P<0.05) higher GPDH activity in the single-culture than the co-culture, whereas CK results of L6 cells were vice versa (P<0.05). Overall, present results may indicate that co-culture system is more reliable and precise technique compared to single-culture. Further studies on several co-culture trials including different media conditions, supplementation of differentiating substances, molecular biological analysis, etc. should be required to obtain practical and fundamental mass data.

Analysis of State-Trait Anxiety Inventory for Patients Diagnosed with Insomnia in an Outpatient Department (상태-특성 불안척도를 이용한 불면 장애 환자 군들에 대한 분석)

  • Lee, Sang Don;Ryu, Seung-Ho;Ha, Jee Hyun;Jeon, Hong Jun;Park, Doo-Heum
    • Sleep Medicine and Psychophysiology
    • /
    • v.26 no.2
    • /
    • pp.104-110
    • /
    • 2019
  • Objectives: Insomnia patients who visited the psychiatric outpatient of a university department, were divided into those patients with insomnia alone and those with depression or anxiety disorder, along with insomnia. The study analyzed their demographic characteristics and the differences in State-Trait Anxiety Inventory (STAI) results among the patient groups. Methods: Patients who visited the psychiatric department in Konkuk University hospital from 1 January 2006 to 31 December 2018. If they were diagnosed with insomnia disorder based on DSM IV-TR and had undergone STAI, their electronic records were retrospectively analyzed. Based on the records, the patients were classified into those with insomnia disorder only, those with insomnia and anxiety disorder, and those with insomnia and depressive disorder. This study analyzed the demographic characteristics and STAI results of each group, and compared the differences among those groups. Results: During the period, 99 of 329 insomnia disorder patients who had performed STAI were diagnosed with depressive concurrent disorder and 61 with concurrent anxiety disorder. There was no difference in demographic characteristics of age and sex ratio among the three patient groups, and all had greater than 70% proportions of patients aged from 50s to 70s (71.8%, 77.1%, and 73.8% respectively). The average scores of STAI-I were 51.85 ± 10.15 for the patients with anxiety disorders and 54.18 ± 10.32 for those with depressive disorders, both of which were higher than the score of the patients with insomnia alone (44.55 ± 8.89). However, the score difference was not statically significant between the anxiety and depression groups. Similarly, in the STAI-II comparison, the averages of patients with anxiety or depressive disorders along with insomnia were 49.98 ± 8.31 and 53.19 ± 10.13 respectively, which were higher than that of the insomnia only group (42.71 ± 8.84), but there was no significant difference between the anxiety and depressive disorder groups. Conclusion: Although there were no differences in demographic data between the patients with insomnia only and those with accompanying depressive or anxiety disorder, the STAI-I and II scores were lower in the insomnia only group. In the future, it is necessary to consider other demographic characteristics including comorbidities and to conduct similar analyses with a larger sample.

High-resolution Spiral-scan Imaging at 3 Tesla MRI (3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상)

  • Kim, P.K.;Lim, J.W.;Kang, S.W.;Cho, S.H.;Jeon, S.Y.;Lim, H.J.;Park, H.C.;Oh, S.J.;Lee, H.K.;Ahn, C.B.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.108-116
    • /
    • 2006
  • Purpose : High-resolution spiral-scan imaging is performed at 3 Tesla MRI system. Since the gradient waveforms for the spiral-scan imaging have lower slopes than those for the Echo Planar Imaging (EPI), they can be implemented with the gradient systems having lower slew rates. The spiral-scan imaging also involves less eddy currents due to the smooth gradient waveforms. The spiral-scan imaging method does not suffer from high specific absorption rate (SAR), which is one of the main obstacles in high field imaging for rf echo-based fast imaging methods such as fast spin echo techniques. Thus, the spiral-scan imaging has a great potential for the high-speed imaging in high magnetic fields. In this paper, we presented various high-resolution images obtained by the spiral-scan methods at 3T MRI system for various applications. Materials and Methods : High-resolution spiral-scan imaging technique is implemented at 3T whole body MRI system. An efficient and fast higher-order shimming technique is developed to reduce the inhomogeneity, and the single-shot and interleaved spiral-scan imaging methods are developed. Spin-echo and gradient-echo based spiral-scan imaging methods are implemented, and image contrast and signal-tonoise ratio are controlled by the echo time, repetition time, and the rf flip angles. Results : Spiral-scan images having various resolutions are obtained at 3T MRI system. Since the absolute magnitude of the inhomogeneity is increasing in higher magnetic fields, higher order shimming to reduce the inhomogeneity becomes more important. A fast shimming technique in which axial, sagittal, and coronal sectional inhomogeneity maps are obtained in one scan is developed, and the shimming method based on the analysis of spherical harmonics of the inhomogeneity map is applied. For phantom and invivo head imaging, image matrix size of about $100{\times}100$ is obtained by a single-shot spiral-scan imaging, and a matrix size of $256{\times}256$ is obtained by the interleaved spiral-scan imaging with the number of interleaves of from 6 to 12. Conclusion : High field imaging becomes increasingly important due to the improved signal-to-noise ratio, larger spectral separation, and the higher BOLD-based contrast. The increasing SAR is, however, a limiting factor in high field imaging. Since the spiral-scan imaging has a very low SAR, and lower hardware requirements for the implementation of the technique compared to EPI, it is suitable for a rapid imaging in high fields. In this paper, the spiral-scan imaging with various resolutions from $100{\times}100$ to $256{\times}256$ by controlling the number of interleaves are developed for the high-speed imaging in high magnetic fields.

  • PDF

A Study on Formulation of Surfactant-free Aqueous Cleaning agents and Evaluation of Their Physical Properties and Cleaning Ability (계면활성제 무첨가 세정제의 배합 및 물성/세정성 평가 연구)

  • Lee, Jae Ryoung;Yoon, Hee Keun;Lee, Min Jae;Bae, Jae Heum;Bae, Soo Jeong;Lee, Ho Yeoul;Kim, Jong Hee
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.219-225
    • /
    • 2013
  • Environment-friendly and surfactant-free aqueous cleaning agents have been developed in order to solve various problems generated by surfactants in the aqueous cleaning agents. Aqueous surfactant-free cleaning agents, S-1 and S-2 have been formulated with water-soluble solvents such as propylene glycol and propylene glycol ether on their main components and with some additives. These solvents were chosen because of their good solubility in water and excellent solubility of fluxes which are major contaminants of printed circuit board in the electronic industry. Physical properties of the formulated and the imported cleaning agents were measured to predict their cleaning performance, and their cleaning abilities of flux and solder contaminants were evaluated under the various ultrasonic frequencies by a gravimetric method. The measurement results show that the physical properties of cleaning agent V are generally similar with those of formulated cleaning agents S-1 and S-2. Both the cleaning agent V and the formulated cleaning agents S-1 and S-2 showed similar trends that their pH decrease in the beginning and then increases later on with the increase of their dilution in water. It is considered that the wetting indices of the cleaning agents calculated with experimental values do not not have any influence on their cleaning ability. In ultrasonic cleaning tests under three ultrasonic frequencies of 28, 45, and 100 kHz, their best performances of cleaning solder and flux were obtained at 45 kHz and 28 kHz, respectively, and the cleaning performance of the formulated cleaning agents S-1 and S-2 was better than that of the cleaning agent V. However, in the case of the recommended diluted concentration of 25 wt% cleaning solution, the cleaning performance of the cleaner V for solder and flux was better in the initial stage of cleaning compared to the formulated cleaners. And it may be concluded that the formulated cleaning agents S-1 and S-2 can be applied to cleaning of solder and flux in the industry, based on the experimental results in this study.

Correlation between Heart Rate Variability and Sleep Structure in Primary Insomnia (일차성 불면증에서 심박동률변이도와 수면구조 간의 상관관계)

  • Lee, Sang-Jin;Park, Doo-Heum;Yu, Jae-Hak;Ryu, Seung-Ho;Ha, Ji-Hyeon;Song, Man-Kyoo
    • Sleep Medicine and Psychophysiology
    • /
    • v.17 no.1
    • /
    • pp.21-27
    • /
    • 2010
  • Objectives: It is well established that primary insomnia affects the activity of autonomic nervous system. We tried to know how the activity of autonomic nervous system during night sleep changes by analyzing correlation between heart rate variability (HRV) index and the variables related with sleep structure in primary insomnia. Methods: Thirty three subjects (mean age: $36.2{\pm}14.2$ years, male:female=15:18) who were diagnosed with primary insomnia were selected for the study. Nocturnal polysomnography (NPSG) was carried out on each subject and correlation was analyzed between high frequency/low frequency ratio (LF/HF ratio), one of HRV indices and the variables related with sleep structure which were calculated from NPSG. Results: When age and sex were controlled, LF/HF ratio showed negative correlations with slow wave sleep and stage 2 sleep, respectively ($r_p$=-0.43, p=0.01; $r_p$=-0.37, p=0.04). On the other hands LF/HF ratio showed a positive correlation with arousal index ($r_p$=0.65, p<0.001). The activity of autonomic nervous system responded differentially depending on the change of sleep structure in primary insomnia. Especially the increase of arousal index and the decrease of slow wave sleep and stage 2 sleep which are the components of non-REM sleep provoked hyperactivity of sympathetic nervous system. Conclusion: This study suggests that the typical change of sleep structure in primary insomnia can negatively impact on cardiovascular system.

  • PDF

OPERATIONAL MODEL OF TIME-KEEPING SYSTEMS OF HEUMGYEONGGAK-NU (흠경각루 시보시스템의 작동모델)

  • KIM, SANG HYUK;YUN, YONG-HYUN;MIHN, BYEONG-HEE;LEEM, BYONG GUEN;YOON, MYUNG KYOON;LEEM, BYONG SI
    • Publications of The Korean Astronomical Society
    • /
    • v.34 no.3
    • /
    • pp.31-40
    • /
    • 2019
  • We study the internal structure under the artificial mountain of Heumkyeonggak-nu, a Korean water-powered clock in the early Joseon dynasty. All the puppets on the artificial mountain are driven by the rotational force generated by the water wheel at their designated time. We design a model that work with three parts of the artificial mountain. At the upper part of the artificial mountain to the east, west, north and south, there are four puppets called the Four Mystical Animal Divinity and four ladies called the Jade Lady respectively. The former rotates a quarter every double hour and the latter rings the bell every hour. In the middle part of this mountain is the timekeeping platform with four puppets; the Timekeeping Official (Hour Jack), the Bell-, Drum-, and Gong-Warriors. The Hour Jack controls time with three warriors each hitting his own bell, drum, and gong, respectively. In the plain there are 12 Jade Lady puppets (the lower ladies) combined with 12 Oriental Animal Deity puppets. In his own time a lady doll pops out of the hole and her animal doll gets up. Two hours later, the animal deity lies down and his lady hides in the artificial plain. These puppets are regularly moved by the signal such as iron balls, bumps, levers, and so on. We can use balls and bumps to explain the concept of the Jujeon system. Iron balls were used to manipulate puppets of the timekeeping mechanism in Borugak-nu, another Korean water-powered clock in Joseon dynasty, which was developed earlier than Heumgyeonggak-nu. According to the North Korea's previous study (Choi, 1974), it is obvious that bumps were used in the internal structure of Heumgyeonggak-nu. In 1669, The armillary clock made by Song, I-young was also utilized bumps. Finally we presented mock-ups of three timekeeping systems.

Blood Lead and ZPP Concentrations of Underground Parking Lot Workers (지하주차장 근무자의 혈중 연 및 Zinc Protoporphyrin 농도)

  • Jung, Tae-Heum;Jeon, Man-Joong;Hwang, Tae-Yoon;Kim, Chang-Yoon;Chung, Jong-Hak
    • Journal of Yeungnam Medical Science
    • /
    • v.15 no.2
    • /
    • pp.224-236
    • /
    • 1998
  • A study was conducted to investigate the blood lead and zinc protoporphyrin(ZPP) concentrations of the underground parking lot workers who exposed to vehicular exhaust aerosols which contained lead. The blood samples were collected from 25 study subjects of underground parking lot and from 33 controls in Taegu, from July to October, 1997. And also the related factors to the blood lead and ZPP concentrations were investigated. Blood lead concentration and ZPP concentration were measured by flameless furnace atomic absorption spectrophotometer (1L.551) and hemetofluorometer, respectively. The mean blood lead concentrations of study subjects and controls were $23.10{\pm}20.77{\mu}g/dl$ and $12.99{\pm}12.71{\mu}g/dl$, respectively(p<0.05), and the mean blood ZPP concentrations of study subjects and controls were $40.72{\pm}9.46{\mu}g/dl$ and $38.21{\pm}10.97{\mu}g/dl$, respectively. No significant correlations were observed between the blood lead concentration of the study subjects and their job duration and between blood ZPP concentration of the study subjects and their job duration. There were no statistically significant differences in the blood lead concentration and the blood ZPP concentration of smokers and nonsmokers. In multiple regression analysis on blood lead concentration of the study subjects and controls, occupation was a only significant dependent variable. In case of bood ZPP concentration, age was a only significant dependent variable in the study subjects and controls.

  • PDF

Evaluation of Cleanness and Physical Properties of W/O Microemulsion (W/O Microemulsion 세정제의 물성 및 세정성 평가)

  • Lee, Myung Jin;Han, Ji Won;Lee, Ho Yeol;Han, Sang Won;Bae, Jae Heum;Park, Byeong Deog
    • Korean Chemical Engineering Research
    • /
    • v.40 no.6
    • /
    • pp.769-777
    • /
    • 2002
  • Using four components - nonionic surfactants, water, hydrocarbon oil and an alcohol as cosurfactant, 12 types of cleaning agents were prepared, and their physical properties such as surface tension, viscosity, electroconductivity and phase stability were measured. As the formulated cleaning agents have low surface tensions(30.5-31.1 dyne/cm) and low viscosities (1.6-7.2 c.p.), they are satisfied with the general physical properties of water-in-oil(W/O) microemulsions for their industrial use. They showed a tendency that their temperature range for stable one-phase microemulsion decreased in accordance with the increase of alcohol/surfactant(A/S) ratio in the formulations. However, the temperature range of one-phase microemulsion was much more affected by hydrophilic lipophillic balance(HLB) value of the nonionic surfactant which increased its temperature range and it increased in accordance with the higher HLB value in the formulations. And the maximum content of water which can keep stable one-phase W/O microemulsion was measured at each sample. In addition, their temperature range for stable one-phase microemulsion was also measured. It was confirmed that the selection of surfactant type was very important for formulating a cleaning agent, since the W/O microemulsion system with the nonionic surfactant of the lower HLB value showed better cleaning efficacy that of the higher HLB value for abietic acid as a soil, which was used for preparing a rosin-type flux. In the formulated cleaning agents with the increase of A/S ratio in the formulations, however, there was no significant difference in cleaning efficacy. It was investigated that the differences of their cleaning efficacy was affected by the change of the condition of temperature and sonicating frequency as important factors in the industrial cleaning. That is, the higher, their cleaning temperature and the lower, their sonicating frequency, the more increased, their cleaning efficacy. Furthermore, using optical instruments like UV/Visable Spectrophotometer and FT-IR Spectrometer, their cleaning efficacy for abietic acid was measured. The removal of soil from the contaminated rinse water was measured by gravity separation method in the rinse bath. As a result, the cleaning agent system having the nonionic surfactant of HLB value 6.4 showed over 85% water-oil separation efficacy at over $25^{\circ}C$. Therefore, it was demonstrated in this work that the formulating cleaning agents were very effective for cleaning and economical in the possible introduction of water recycling system.

A Study on Development of Alternative Non-aqueous Cleaning Agents to Ozone Depletion Substances and its Field Application (오존파괴물질 대체 비수계세정제 개발 및 현장 적용 연구)

  • Park, Yong-Bae;Bae, Jae-Heum;Lee, Min-Jae;Lee, Jong-Gi;Lee, Ho-Yeoul;Bae, Soo-Jung;Lee, Dong-Kee
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.306-313
    • /
    • 2011
  • Flux or solder is used in soldering process for manufacturing electronic parts such as printed circuit boards (PCB). After soldering process, residual flux and solder paste on the parts should be removed since their residuals could cause performance degradation or failure of parts due to their corrosion and electric leakage. Ozone depletion substances such as 1,1,1- trichloroethane (TCE) and HCFC-141b have widely been using for removal of residual flux and solder paste after soldering process In manufacturing of electronic parts until now. In this study, non-aqueous cleaning agents without flash point were developed and applied to industrial field for replacement of cleaning agents with ozone depletion. In order to develop non-aqueous cleaning agents without ethers, esters, fluoride- type solvents. And their physical properties and cleaning abilities were evaluated, and they were applied to industrial fields for cleaning of flux and solder on the PCB. And vacuum distillation apparatus were operated to determine their operating conditions and recycling yields for recycling of used cleaning agents formulated in this study. As a result of physical properties measurement of our formulated cleaning agents, they were expected to have good wetting and penetrating power since their surface tensions were relatively low as 18.0~20.4 dyne/$cm^2$ and their wetting indices are relatively large. And some cleaning agents holding fluoride-type solvents as their components did not have any flash point and they seemed to be safe in their handling and storage. The cleaning experimental results showed that some cleaning agents were better in their cleaning of flux and solder paste than 1,1,1-TCE and HCFC-141b. And industrial application results of the formulated cleaning agents for cleaning PCB indicated that they can be applicable to industry due to their good cleaning capability in comparison with HCFC-141b. The recycling experiments of the used formulated cleaning agents through a vacuum distillation apparatus also showed that their 91.9~97.5% could be recycled with its proper operating conditions.

Development of Environmental-friendly Cleaning Agents Utilizing Organic Acids for Removal of Scale on the Wall of Cleaning Beds and Distribution Reservoirs in the Waterworks (유기산을 이용한 상수도 정수장 및 배수지 벽면 스케일 세척용 친환경 세정제 개발)

  • Lee, Jae-Ryoung;Yoon, Hee-Keun;Bae, Jae-Heum;Shin, Hyun-Duk
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.272-279
    • /
    • 2012
  • In this study, an environmental-friendly cleaning agent utilizing organic acids and various additives has been developed and applied to the field for removal of scale deposited on the cleaning beds or distribution reservoirs of the waterworks. As an analytical result of scale on the cleaning beds, we found that it consists of mainly metallic oxides such as $SiO_2$, $Al_2O_3$, $Fe_2O_3$, and MnO. Malic acid, malonic acid, and citric acid showed relatively better solvency on $Al_2O_3$, $Fe_2O_3$, and MnO except $SiO_2$ among various organic acids. Mixed organic acid solutions of malic acid, malonic acid, and citric acid were prepared with certain weight ratios and their solvencies on mixed metal oxides of $Al_2O_3$, $Fe_2O_3$, and MnO were investigated. The experimental results showed that an 10% mixed organic acid solution prepared with weight ratio of malic acid : malonic acid : citric acid = 6 : 2 : 2 were found to have best scale solvency power of about 29%. The formulated cleaning agents with a small amount of nonionic surfactant showed much better solvency on mixed oxides than mixed organic solution alone. Especially, the formulated cleaning agent with 0.2 wt% LA-7 surfactant appeared to have best scale removal efficiency of about 35%. However, the formulated cleaning agent with disinfectants such as NaClO, $H_2O_2$ and $Ca(ClO)_2$ showed poor solvency on mixed oxides. It is inferred that surfactants are able to improve scale removal efficiency due to their capability of emulsification, and disinfectants cause to degrade scale solvency in water because of their oxidation. Based on these basic experimental results, formulated cleaning agents have been prepared with mixed organic acid solution, nonionic surfactants, and disinfectants and successfully applied to removal of scales on the cleaning beds and distribution reservoir at city D waterworks.