• Title/Summary/Keyword: 이용흠

Search Result 476, Processing Time 0.028 seconds

Effects of Fusion Level for Scioliotic Spine Correction Simulation with Pedicle Screw and Rod Derotation Method (척추경 나사못 고정과 강봉 감염술을 이용한 척추 측만증 교정 해석시 유합 범위에 따른 교정 효과 분석)

  • 김영은;손창규;최형연;하정현;이춘기
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.1
    • /
    • pp.71-76
    • /
    • 2004
  • In order to investigate the Post-operative changes in scoliotic spine according to selection of fusion level a mathematical finite element model of King-Moe type II scoliotics spine system was developed. By utilizing this finite element scoliosis model surgical correction simulation procedures of pedicle fixation and derotation were simulated. In consequence of the calculation by changing the fusion Levels, postoperative changes like Cobb angle, apical vertebrae axial rotation (AVAR), thoracic kyphosis, and rib hump were Qualitatively analyzed. In the analysis of operative kinematics, the decrease or Cobb angle was most prominent in distraction than in deroation. Applying the rod derotation only was not effective in decrease of Cobb angle but just caused increase of At AR and rib hump. From the operative simulation, co-action or distraction and translation during rod insertion has major impact on Cobb angle decrease and maintenance of kyphosis. With rod rotation, Cobb angle decrease was obtained, but combined increase of AVAR and rib hump was simulation observed as well. The case of most extended instrumentation range with 60o rod rotation produced double decrease of Cobb angle, but the increase of rib hump and AYAR occurred corresponding1y. The optimum selection of fusion level was proved as one level less than inflection position of the thoracic spine curvature.

추적자를 이용한 오염물질 거동분석

  • Kim, Gi-Cheol;Lee, Jong-Seok;Lee, Jae-Cheol;Kim, Yun-Ho;Yeon, Gi-Heum
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.289-293
    • /
    • 2008
  • In this study, in order to find out the movement of polluted substance that is flown into the river and the characteristics of dispersion, the experiment that used the RI (Radio Isotope) tracer in the river was undertaken, and by using the experiment result, the figure modelling was undertaken to analyze the general type of pollutant dispersion. In addition, in order to calculate more accurate dispersion range and moving time, the experiment was done in about 2km from the measuring points of Namdaecheon around the Yongdam Dam of the upper Geum River to the lower stream, and modeling was undertaken for the 20km zone from the measuring points to the lower stream. In order to find out the flow of river and dispersion of polluted substance, RMA (Resource Modeling Associates)-2 and RMA-4 program are used in study. The site experiment using the RI was implemented for the experiment in the applied area and the same area, and the distance between each zone was set for 1㎞ with the slight difference for site situation and measured the density date of one second distance through the NaI apparatus to measure the density data of one second interval. On the basis of this measured data, it is compared and analyzed with the result of figure copy of RMA-2 and RMA-4 models to make the comparison and analysis of density distribution following the change in expansion coefficient that makes great influence on expansion range and dispersion in natural rivers. The influence of expansion coefficient on river can be researched and the measured density data, the maximum and minimum density time, and the basic data to calculate the expansion coefficient was prepared in this study.

  • PDF

Evaluation of Muscle Fatigue Recovery Effect and Meridian Potential Change using Magnetic Acupuncture System (자화침 시스템을 이용한 경락전위 유발효과 및 근피로 회복 평가)

  • Kim, Soo-Byeong;Park, Sun-Woo;Ahn, Soon-Jae;Lee, Na-Ra;Lee, Seung-Wook;Min, Se-Eun;Kim, Young-Ho;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.29 no.1
    • /
    • pp.83-92
    • /
    • 2012
  • Objectives : The purpose of this research was to develop the magnetic acupuncture system which used solenoid coil for magnetizing acupuncture needle. The system could generate the meridian electric potential (MEP) similar to the potential by manual acupuncture. Thus, we tried to confirm the therapeutic effect that is caused by the MEP generation. Methods : To confirm the MEP, we stimulated the magnetic acupuncture with at 2Hz, $92.7{\pm}2mT$, PEMFs (Pulsed Electro-Magnetic Fields) at ST37 and measured the evoked potential between ST36 and ST41. Also, we conducted a fatigue recovery test using isokinetic exercise in order to identify the therapeutic effect on musculoskeletal disorders. We chose LR9 as a stimulation point. To observe the state of fatigue, we measured the EMG and analyzed median frequency and peak torque for 20minutes. Results : We observed that MEP which incurred from magnetic acupuncture was higher than he reported MEP induced by manual acupuncture. Moreover, its modes were divided into two types by the direction of magnetic flux. When generating magnetic flux in the direction of acupoint, the positive peak voltage of the MEP was generated. In contrast, negative peak voltage of the MEP was generated whenever meganetic flux generated in the outward direction. As a result of fatigue recovery, the median frequency (MF) of the magnetic acupuncture group were recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Conclusions : We confirmed that the magnetic acupuncture system can lead to the MEP similar to manual acupuncture. Moreover, the MEP had a therapeutic effect on the musculoskeletal disorders.

Effect of Diffuser Locations on the Room Acoustical Parameters in 1:25 Scale Model Hall (1:25 축소모형 홀에서 확산체의 설치부위에 따른 실내 음향지표의 변화)

  • Kim, Yong-Hee;Seo, Choon-Ki;Lee, Hye-Mi;Jeon, Jin-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.115-128
    • /
    • 2012
  • This paper investigates the effects of diffuser on the acoustical parameters in music hall with consideration of the result of scattering coefficient measurement. A scale model hall of 600 seats with orchestra shell was used for experiments. The materials of 1:50 scale model was chosen through absorption coefficient measurement based on ISO 354. The model was matched to the computer simulation model in terms of reverberation time. In order to evaluate the effect of diffuser location, the measurements were accomplished with and without diffusers according to 7 configurations by diffuser-installed region; sidewall, balcony front, ceiling and so on. The following acoustical parameters were extracted from each measurement case; Reverberation time (RT), Early decay time (EDT), Clarity (C80), Center time (Ts), Sound strength (G) and Temporal diffusion (TD) from the auto-correlation function (ACF) of impulse responses. As a result, the absorption power and diffusion power were increased with number of diffusers. Accordingly RT, EDT and G were decreased by diffuser and the redirection of reflections was occurred briskly. Averaged TD was 6.05 to 6.30 by measurement cases. RT was found to be the most related factor to diffusion power (R = 0.94). The correlation between TD and EDT was high (R = 0.73). In addition, the effects of diffuser-installed location were discussed in terms of acoustical parameter variation.

Design of Gastrointestinal Diagnosis System based on Ultrasonic Response Characteristics (초음파 응답특성 분석에 의한 위장 경화 진단시스템의 설계)

  • Lim, Do-Hyung;Kim, Eun-Geun;Lee, Gyoun-Jung;Park, Won-Pil;Kim, Han-Sung;Shin, Tae-Min;Choi, Seo-Hyung;Lee, Yong-Heum
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.250-257
    • /
    • 2007
  • Functional gastrointestinal disorders affect millions of people of all age regardless of race and sex. There are, however, rare diagnostic methods for the functional gastrointestinal disorders because functional disorders show no evidence of organic and physical causes. Our research group identified recently that the gastrointestinal tract well in the patients with the functional gastrointestinal disorders becomes more rigid than healthy people when palpating the abdominal regions overlaying the gastrointestinal tract. The aim is, therefore, to develop a diagnostic method for the functional gastrointestinal disorders based on quantitative measurement of the rigidity of the gastrointestinal tract well using ultrasound technique. For this purpose, a preliminary ultrasound diagnostic system was developed and verified through phantom tests. The system consisted of transmitter, ultrasonic transducer, receiver, TGC, and CPLD, and verified via a phantom test. For the phantom test, ten soft-tissue specimens were harvested from porcine. Five of them were then treated chemically to mimic a rigid condition of gastrointestinal tract well, which was induced by functional gastrointestinal disorders. Additionally, the specimens were tested mechanically to identify if the mimic was reasonable. The customized ultrasound system was finally verified through application to human subjects with/without functional gastrointestinal disorders(Normal and Patient Groups). It was identified from the mechanical test that the chemically treated specimens were more rigid than normalspecimen. This finding was favorably compared with the result obtained from the phantom test. The phantom test also showed that ultrasound system well described the specimen geometric characteristics and detected an alteration in the specimens. The maximum amplitude of the ultrasonic reflective signal in the rigid specimens $(0.2{\pm}0.1Vp-p)$ at the interface between the fat and muscle layers was explicitly higher than that in the normal specimens $(0.1{\pm}0.0Vp-p)$ (p<0.05). Clinical tests using our customized ultrasound system for human subject showed that the maximum amplitudes of the ultrasonic reflective signals nea. to the gastrointestinal tract well for the patient group$(2.6{\pm}0.3Vp-p)$ were generally higher than those in normal group$(0.1{\pm}0.2Vp-p)$ (p<0.05). These results suggest that newly designed diagnostic system based on ultrasound technique may diagnose enough the functional gastrointestinal disorders.

Development of a Moving Body Type Wave Power Generator using Wave Horizontal Motions and Hydraulic Experiment for Electric Power Production (파의 수평운동을 이용한 가동물체형 파력발전장치의 개발과 전력생산에 관한 수리실험)

  • Hwang, Seong Su;Lee, Dong Soo;Yang, Kyong Uk;Byun, Jung Hwan;Park, Il Heum
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.28 no.2
    • /
    • pp.73-80
    • /
    • 2016
  • To reduce the mechanical energy loss and to get the high energy efficiency, an apparatus of wave power generation inducing a consistent one way rotating motion from the wave reciprocation motions was developed and the hydraulic experiments for the real electric power production were conducted and the results were discussed. In the experiments for the shape of the buoyant tank, the efficiency of the fixed 9 cm diameter type enduring the wave plate weight was 14.6% and this was the best result for all shapes. But although the free sliding type was expected to represent a high efficiency, the experiments did not show a good result as 8.5% efficiency. Therefore, the shape of buoyant tank was decided as the fixed 9 cm diameter type in the next all tests. In the experiments for the various incident waves, when the water depth was 90 cm, the average efficiencies were measured as 3.9% in the 2nd gear, 4.9% in the 3rd gear, 4.9% in the 4th gear, 12.0% in the 5th gear, 10.0% in the 6th gear, 3.1% in the 7th gear, and 3.0% in the 8th gear. Also, when the water depth was 80 cm, the average efficiency was shown as 15.0% with 5th gear condition. Therefore the high average efficiency as 13.5% was given with 80~90 cm water depth and the 5th gear in the model.

Remaining Useful Life Prediction of Li-Ion Battery Based on Charge Voltage Characteristics (충전 전압 특성을 이용한 리튬 이온 배터리의 잔존 수명 예측)

  • Sim, Seong Heum;Gang, Jin Hyuk;An, Dawn;Kim, Sun Il;Kim, Jin Young;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.313-322
    • /
    • 2013
  • Batteries, which are being used as energy sources in various applications, tend to degrade, and their capacity declines with repeated charging and discharging cycles. A battery is considered to fail when it reaches 80% of its initial capacity. To predict this, prognosis techniques are attracting attention in recent years in the battery community. In this study, a method is proposed for estimating the battery health and predicting its remaining useful life (RUL) based on the slope of the charge voltage curve. During this process, a Bayesian framework is employed to manage various uncertainties, and a Particle Filter (PF) algorithm is applied to estimate the degradation of the model parameters and to predict the RUL in the form of a probability distribution. Two sets of test data-one from the NASA Ames Research Center and another from our own experiment-for an Li-ion battery are used for illustrating this technique. As a result of the study, it is concluded that the slope can be a good indicator of the battery health and PF is a useful tool for the reliable prediction of RUL.

Characteristics of Meteorological and Marine Environments for the Red Tide Occurrence of Mid-South Sea in Korea (한국 남해중부해역의 적조발생에 관한 기상 및 해양환경 특성)

  • 윤홍주;김승철;박일흠
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.845-852
    • /
    • 2003
  • This study deals with the relationship between the red tide occurrence and the meteorological and marine factors, the prediction of areas where the red tide is likely to occur based on the information, and the satellite monitoring for the red tide in mid-South Sea of Korea. From 1990 to 2001, the red tide was observed every year and the number of occurrences increased as well. The red tide mostly occurred in July, August, and September. The most important meteorological factor governing the mechanisms of the increase in the number of red tide occurrences is found to be a heavy precipitation. It was found that the favorable marine environmental conditions for the red tide formation are some of marine factors such as the warm water temperature, the low salinity, the high suspended solid, the low phosphorus, and the low nitrogen. The necessary conditions for the red tide occurrence are found to be the heavy precipitation (23.4-54.5 mm) for 2∼4 days, the warm temperature $(24.6∼25.9^{\circ}C)$, proper sunshine (2∼10.3 h), and light winds (2∼4.6 m/s & SW) for the day in red tide occurrence. It was possible to monitor the spatial distributions and concentration of the red tide using the satellite images. It was found that the likely areas for red tide occurrence in August 2000 were Yosu - Dolsan coast, Gamak bay, Namhae coast, Marado coast, Goheung coast, and Deukryang bay.

Characteristics of Meteorological and Marine Environments for the Red Tide Occurrence in Mid-South Sea of Korea (한국 남해중부해역의 적조발생에 관한 기상 및 해양환경 특성)

  • 윤홍주;김승철;박일흠
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.323-328
    • /
    • 2003
  • This study deals with the relationship between the red tide occurrence and the meteorological and marine factors, the prediction of areas where the red tide is likely to occur based on the information, and the satellite monitoring for the red tide in mid-South Sea of Korea. From 1990 to 2001, the red tide was observed every year and the number of occurrences increased as well. The red tide mostly occurred in July, August, and September. The most important meteorological factor governing the mechanisms of the increase in the number of red tide occurrences is found to be a heavy precipitation. It was found that the favorable marine environmental conditions for the red tide formation are some of marine factors such as the warm water temperature, the low salinity, the high suspended solid, the low phosphorus, and the low nitrogen. The necessary conditions for the red tide occurrence are found to be the heavy precipitation (23.4∼54.5 mm) for 2∼4 days, the warm temperature (24.64-25.85 $^{\circ}C$), proper sunshine (2∼10.3 h), and light winds (2∼4.6 m/s & SW) for the day in red tide occurrence. It was possible to monitor the spatial distributions and concentration of the red tide using the satellite images. It was found from this study that the likely areas for red tide occurrence in August 2000 were Yosu ∼ Dolsan coast, Gamak bay, Namhae coast, Marado coast, Goheung coast, and Deukryang bay.

  • PDF

Extraction of Parameters for Acupoint Discrimination and Design of discrimination system (경혈식별을 위한 파라메터 추출 및 식별시스템의 설계)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.89-101
    • /
    • 2001
  • The conventional pattern-methods for discrimination of acupoint, meridian line which is the basic object of diagnosis and medical treatment in oriental medicine is discriminated the conduction point by the stimulation in body skin with DC. But, it is not sufficient to truth in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper is extracting the optimal parameter of frequency and waveform in order to improve the conventional pattern, and proposing the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, this algorithm proposes to be able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It is able to decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. It is compared the performance of system applying the extracted optimal parameter and algorithm, and it is confirmed that there is difference in discrimination parameter of acupoint reacted to the individual and the meridian. It is compared that discrimination, coincident ratio of the traditional acupoints as the acupoint stimulation pattern. It is confirmed truth of optimal parameter and discrimination algorithm. Keyword: Meridian, Discrimination, Coincident, Body effect, Reproductivity, SPAC, Optimal parameter.

  • PDF