• Title/Summary/Keyword: 이온 검출

Search Result 638, Processing Time 0.025 seconds

Fabrication of Potentiometric Sodium-ion Sensor Based on Carbon and Silver Inks and its Electrochemical Characteristics (탄소 및 은 잉크 기반의 전위차 나트륨 이온 센서 제조 및 이의 전기화학적 특성)

  • Kim, Seo Jin;Son, Seon Gyu;Yoon, Jo Hee;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.456-460
    • /
    • 2021
  • A potentiometric sodium-ion (Na+) sensor was prepared using a screen-printing process with carbon and silver inks. The two-electrode configuration of the sensor resulted in potential differences in Na+ solutions according to Nernstian equation. The obtained Na+-sensor exhibited an ideal Nernstian sensitivity, fast response time, and low limit of detection. The Nernstian response was stable when the sensor was tested for repeatability and long-term durability. The Na+-selective membrane coated onto the carbon electrode selectively passed sodium ions against interfering ions, indicating an excellent selectivity. The portable Na+-sensor was finally fabricated using a printed circuit system, demonstrating the successful measurements of Na+ concentrations in various real samples.

Heavy Metal Ion Detection in Living Cell Using Fluorescent Chemosensor (형광화학센서를 이용한 살아있는 세포 내에서의 중금속이온검출)

  • Kwon, Pil-Seung;Kim, Jin-Kyung;Kim, Jong-Wan
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.4
    • /
    • pp.451-459
    • /
    • 2010
  • The fluorescence detection of intracellular metal ions are high interest in the fields of organic molecular chemistry and cellular biology. This study was purposed to detection for mercury and zinc in the cell using fluorescent chemosensor (FS). FS exhibits a weak fluorescence, but emits strong fluorescence upon Zn$^{2+}$ complexation. The increased fluorescence of the 2FS/Zn$^{2+}$ can be quenched completely by addition of only 1 equiv of Hg$^{2+}$ with the formation of complex FS-Hg$^{2+}$. Four cell lines (LLC-MK2, Hela, HT29 and AMC-HN3) were used for fluorescence imaging by confocal microscope. The cell viability MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay was evaluated after cell treatment of FS, Zn$^{2+}$, FS-Zn$^{2+}$, Hg$^{2+}$ on LLC-MK2 cell line. The cytotoxicity of FS was showed to viability over 80%. This study has shown that FS can be detected for selective imaging of Zn$^{2+}$ and Hg$^{2+}$ in living cells.

Determination of Some Inorganic Anions in Saline Water by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 소금물중의 무기음이온들의 분리정량)

  • Han, Sun Ho;Park, Yang Soon;Park, Soon Dal;Joe, Kih Soo;Eom, Tae Yoon
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.99-104
    • /
    • 1999
  • A stepwise gradient elution with two wavelengths detection was performed for the separation and determination of some anions in saline water. The eight anions such as iodate, bromate, nitrite, bromide, nitrate, chromate, iodide and thiocyanate were successfully separated using AS-7 column and sodium chloride/sodium phosphate buffer solution as an eluant within 40 min. The separation behaviors of anions were studied at various sodium chloride concentrations. The peak shapes of anions of bromate, nitrite, bromide and nitrate gradually broadened as the concentration of sodium chloride increased until 1.0 M in the sample solutions. However, no effect was observed in the peak shapes of chromate, iodide and thiocynate. A good linearity was obtained at the range of ppm(mg/L). The detection limit was proved to be $10-720{\mu}g/L$ for the eight anions with $50{\mu}L$ injection volume. This method was applied to the determination of $Br^-$, ${NO_3}^-$ and $I^-$ in sea water.

  • PDF

Determination of Trace Iodide in Sodium Bisulfite Aqueous Solution by Ion Chromatography with UV Detection (이온크로마토그래피를 이용한 Sodium bisulfite 수용액 중의 미량 요오드 정량)

  • Park, Yang-Soon;Kim, Do-Yang;Choi, Kwang-Soon;Park, Soon-Dal;Han, Sun-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.304-308
    • /
    • 2000
  • The iodide was recovered from a simulated spent fuel to the sodium bisulfite aqueous solution. It was discussed that the trace iodide (below 1 ppm) was determined without the matrix effect of 0.1 M sodium bisulfite and 1 mM $HNO_3$ in aqueous solution by ion chromatography with UV detection. AS4A-SC (DIONEX) column and UV-absorption spectrophotometer were used. The UV-absorption spectra of sodium bisulfite, nitric acid and iodide were obtained, and then 230 nm was selected as an absorption wavelength for iodide determination. 0.1 M NaCl eluent was optimum condition. In this condition the calibration curve of iodide was obtained on the range of about 0-1,000 ppb. The linear coefficient was 0.99993 and the detection limit was 5 ppb. The relative standard deviation was 1.26%.

  • PDF

Characteristics and Origin of Salts in the Black Surface Layer of Stone Monuments (석조기념물 흑색표면층에 있는 염의 특성과 기원)

  • Do, Jinyoung
    • Journal of Conservation Science
    • /
    • v.12 no.1 s.15
    • /
    • pp.15-25
    • /
    • 2003
  • It is well known that the salt in stoneworks impact on damage of stone by various methods. Various kind of salt is detected in high content in the black surface layer of stone monuments and it is required about origin and roles of salts on blackening to considerate. In this study have been investigated the characteristics of salt in the black crust of sandstone and limestone which used in historical monuments in Berlin, Germany. Salt was analyzed for cation by Atomic Absorption and Atomic Emission Spectroscopy and for anion by ion Chromatograph. The representative ions are $Ca^{2+}\;and\;SO_4^{-2}$ in all samples and the most obvious combinations was proved in calcium sulfate by statistical methods. Because gypsum was detected by X-ray diffraction analyses in the black crusts, this calcium sulfate was confirmed by 2 hydrate type. The probable origin of Ca is air particle in atmosphere around sandstone and calcite in mother rock in limestone, and that of S is polluted air and mortar which used as conservation works.

  • PDF

CsX+ SNMS의 Matrix Effect 감소연구

  • 문환구;김동원;한철현;김영남;심태언
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1992.02a
    • /
    • pp.17-18
    • /
    • 1992
  • SIMS is an indispensable surface analysis instrument in trace element depth p profiling because of high detection sensitivity and excellent depth r resolution, however, it requires standard sample to do quantitative analysis d due to matrix effect depending on the species of impurities and sample m matricies and on the sputtering rates. A Among the SNMS technology developed to supply the deficiency, we researched i into CsX+ SNMS which improved the resul t quanti tati vely wi thout any extra epuipments. So basic SNMS functions were confirmed through matrix element composition rate a analysis using Si02 layer etc. and adaptability to trace element c concentration analysis was tried. For that purpose we compared SIMS depth profile data for Boron which presented s strong matrix effect on account of Fluorin existence after BF2 ion implantation on silicon substrate with SNMS data. d dynamic range were investigated. A After these experements we concluded that CsX+ SNMS reduced matrix effect and we could apply it to profile impurity elements.

  • PDF

A Study on the Composition for Improving the Performance of Inorganic Binders for Conservation Treatment of Stone Cultural Heritages (석조문화재 보존처리용 무기질바인더의 성능개선을 위한 조성물 연구)

  • Lee, Tae Jong;Cho, Ha Jin;Chae, Seung A;Park, Hee Jeong;Kang, San Ha
    • Journal of Conservation Science
    • /
    • v.36 no.5
    • /
    • pp.339-350
    • /
    • 2020
  • This study attempted to apply a hybrid technology that integrated mineral-based fillers and water-repellent agents to control the efflorescence that results from the use of inorganic binders, for the conservation treatment (surface finishing) of cultural heritage materials made up of stone. Herein, different types of mixing ratios of a filler (silica fume 3.4%) and a water repellent (silane-siloxane 1%) were selected for fabricating the inorganic binder, and it was determined that the ratio selected by weight is effective in controlling efflorescence substances. In addition, it was identified that the inorganic binder with the mixing ratio resulted in a higher compressive strength than the standard (20MPa), and the water permeability resistance was high with low water absorption. The result of ion elution from the bilder showed that a smaller number of ions was observed to affect the efflorescence (directly and indirectly) as compared to that of the control group, which was considered to be relatively stable.

Highly Sensitive and Selective Fluorescent Chemosensors Specific for Pd2+ Detection (Pd2+ 검출용 고감도 형광화학센서)

  • Wang, Jing;Ha, Chang-Sik
    • Journal of Adhesion and Interface
    • /
    • v.14 no.1
    • /
    • pp.13-20
    • /
    • 2013
  • Palladium plays a pivotal role in the production of dental and medicinal devices, medicinal substances, jewellery, automobile and high-performance adhesives. Despite the frequent and fruitful use of such reactions, one major setback is the high level of palladium in the resultant compounds which can harm the human body. Among the palladium species, $PdCl_2$ is the most toxic. As a consequence it is desirable to detect the $Pd^{2+}$ cations by fluorescence spectra because it can provide an operationally simple and cost-effective detection method together with high sensitivity and selectivity. Herein, an ${\alpha}$-carbonyl substituted pyrene derivative, ${\gamma}$-oxo-1-pyrenebutyric acid (OPBA), was demonstrated to be a highly sensitive and selective fluorescent probe for $Pd^{2+}$ among the metal cations examined in aqueous solutions.

Treated Water Quality Characteristic of Small Scale Water Works in West Gyeong-Nam (서부경남지역 소규모 급수시설의 정수 수질특성 조사에 관한 연구)

  • Park, Hyungeoun;Kim, Kyungmi
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.7
    • /
    • pp.454-458
    • /
    • 2012
  • The Characteristics of small scale water works at west Gyeong-nam was analyzed by investigationg the 6,569 cases which were carried out from Jan. 2005 to Dec. 2010. The result of the research about treated water quality the highest mean concentration of fluorine was 0.19 mg/L at Hamyang the highest mean concentration of Nitrite nitrogen was 3.7 mg/L at Namhae each the highest mean concentration of Hardness, Total solids, Sulfate was 177 mg/L, 271 mg/L, 80 mg/L at Uiryeong. In the case of waterworks originated from valleys, the total bacterial count and turbidity were higher than ones originated from groundwater. On the other hand, nitrate nitrogen, total solids, hardness, sulfate, fluorine and iron were detected more than ones originated from valleys.

Determination of Polybrominated Diphenyl Ethers(PBDEs) in Soil using Gas Chromatography/Isotope Dilution Mass Spectrometry (기체크로마토그래피/동위원소 희석 질량분석법을 이용한 토양 중 폴리브롬화 디페닐에테르의 분석법)

  • Na, Yuncheol;Chang, Yoon-Seok;Kim, Hai-Dong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • An analytical method of polybrominated diphenyl ethers in soil samples by isotope dilution method using gas chromatography/mass spectrometry (GC/MS)-selected ion monitoring (SIM) was described. PBDEs in soil were extracted with soxhlet extractor and then silica and florisil solid phase extraction (SPE) methods as purification of extract were compared. After clean-up, the extractions were analyzed by GC/MS with SIM mode. Quantitation was performed isotope dilution method using four $^{13}C$ isotopically labeled PBDEs as internal standards. This developed method was validated for eight congeners of PBDEs in the concentration range 0.04~4 ng/g in soil and the average recovery of the analytes ranged 30.8~110.8% for florisil and 44.4~110.7% for silica, respectively. The method detection limits of PBDEs were 0.04~0.3 ng/g.